0% found this document useful (0 votes)
256 views10 pages

PVS

The document describes the PVS Series Portable Purification Systems from Parker Hannifin, which are used to draw contaminated fluid from a system, remove water and other contaminants, and return clean fluid to the reservoir. The systems are available in multiple models with maximum flows up to 170 l/min. They reduce issues caused by water contamination like corrosion and wear. The document provides details on how the systems operate, their applications, and key features.

Uploaded by

Antonio Díaz
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
256 views10 pages

PVS

The document describes the PVS Series Portable Purification Systems from Parker Hannifin, which are used to draw contaminated fluid from a system, remove water and other contaminants, and return clean fluid to the reservoir. The systems are available in multiple models with maximum flows up to 170 l/min. They reduce issues caused by water contamination like corrosion and wear. The document provides details on how the systems operate, their applications, and key features.

Uploaded by

Antonio Díaz
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

PVS Series - Models 185,

600, 1200, 1800 and 2700


Portable Purification Systems

Reduce the
catastrophic
results of water
contamination
Eliminate water from the
hydraulic system

The PVS Series Portable Purification


Systems, available in several models,
is used to draw water contaminated
fluid out of a system, remove the
water content and return the ‘clean’
fluid to the reservoir. Maximum
flow 170 l/min (PVS2700). Reduce
the catastrophic results of water
contamination.

Contact Information: Product Features:


Parker Hannifin • PVS draws water contaminated fluid out of a system.
Hydraulic Filter Division Europe • Removes water, air and particulate content and returns the
‘clean’ fluid to the reservoir.
European Product • Maximum flow 170 l/min (PSV2700).
Information Centre • Reduce the catastrophic results of water contamination.
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
[email protected]

www.parkerhfde.com

Parker Hannifin
Hydraulic Filter Division Europe
253 FDHB500UK.
PVS Series
Portable Purification Systems

Effects of Water Contamination Principles of Operation

Water is one of the most common and destructive Contaminated oil is drawn into the Parker portable
contaminants in a fluid system. When water purification system by a vacuum of 25 In/Hg. The
contaminates a system, it can cause serious oil passes through the in-line low watt density
problems such as: heater/s where the oil is heated to an optimum
temperature of 66°C (150°F).
Corrosion by etching metal
Fluid breakdown, reduction of lubricating The oil then enters the distillation column where it is
properties, additive precipitation, and oil exposed to the vacuum through the use of dedicated
oxidation dispersal elements. This increases the exposed
surface area of the oil and converts the water to
Reduced dielectric strength
a vapor form, which is then drawn through the
Abrasive wear in hydraulic components condenser by the vacuum pump. The vapour returns
to water and drops into the condensate holding tank
- this can then be drained off at a later stage.
Typical saturation points
Fluid type PPM % The water-free oil falls to the bottom of the vacuum
Hydraulic fluid 300 .03%
chamber and is passed through a final particulate
removal filter by a heavy duty lube oil pump.
Lubrication fluid 400 .04%
Transformer fluid 50 .005% Clean dry oil re-enters the reservoir/system via the
outlet port.
Free water occurs when oil becomes saturated
and cannot hold any more water. This water is
usually seen as cloudy oil or puddles of water
at the bottom of an oil reservoir. Water which is
absorbed into the oil is called dissolved water.
At higher temperatures, oil has the ability to hold
more water in the dissolved stage due to the
expansion of oil molecules. As the oil cools, this
ability reverses and free water will appear where
not visible before. In addition to temperature, fluid
type also determines the saturation point for your
system (see chart above).

250
% Bearing Life Remaining

200

150

100

50

0
% Water In Oil

Parker Hannifin
Hydraulic Filter Division Europe
254 FDHB500UK.
Applications for PVS Portable Purification Systems
Paper mills
- Dryer lubrication Low watt density
heater
- Hydraulic Air Cooled
Condenser
- Compressor lubrication Self diagnosing
controls include:
- Calenders Programmable
thermostat
Steel mills
Reverse pole switch/
- Bearing lubrication phase fail
% RH display
- Continuous casters
- Press roll lubrication
Condensate
Power generation holding tank

- Turbine oil
- Transformer oil Liquid level sight
glass
- EHC systems Vacuum pump
Industrial/aerospace
Caster wheels
- Test stands Forklift guides

- Machine tools

Features Advantages Benefits


Variable flow circuit Allows oil to heat to required Starts removing water quickly
temperature quickly
Moisture sensor Real-time water content indication Indicates when safe water content level
is obtained
Condensate holding tank Captures removed water/solvents Eliminate potential hazard of exhausting
Large enough to provide long service to atmosphere
interval Reduced maintenance costs
Compact size Smallest envelope in the industry Fits through doorways and down
Ease of portability narrow aisles
Increased use
Forklift guides Provides safe and secure method to Employee safety
Lifting eyes lift unit Easily transported
Programmable thermostat Maintains oil within 1°C Unattended operation
Prevents overheating oil Increases oil life
Automatic operation Unattended use Reduced labour costs
Increased running time
Reverse pole switch/phase fail Change motor rotation for different power Flexibility, less maintenance
source locations Prevents incorrect rotation
High temperature safety circuit Shuts down heater if primary Prevents system damage
contacters fail
Oil can never exceed 120°C (250°F) Worker safety
Circuit breakers utilised in No fuses to replace Fewer spare parts, increased uptime
electrical panel Simple diagnostics Reduced maintenance
Available with EPR seals and Phosphate ester compatible Specifically designed for application
stainless steel
Solid state heater contacter Longer more reliable service life Reduced downtime

Parker Hannifin
Hydraulic Filter Division Europe
255 FDHB500UK.
PVS Series
Portable Purification Systems

Typical Performance

Potential PVS Tank size 227 litres (50 gallons)


contaminant performance
Solid particulate ISO cleanliness code* Run time 62 minutes
14/13/10 attainable
Water Removes 100% of free water,
Parker model PVS 600 (37.9 l/min)
80-90% of dissolved water.
Air Removes 100% of free air,
Water content (ppm) Start: 10,000 PPM (1.0%)
90% of dissolved air.
Stop: 50 PPM(0.005%)
Gases Removes 100% of free gases,
90% of dissolved gases.
Contamination level Start: ISO 21/18/16
* When utilising 2Q media
Stop: ISO 16/14/11
PVS (Vacuum dehydration)
compared to other technologies
Centrifuge units – Removes free water only; has difficulty
breaking stable emulsions; larger envelope dimensions but
lower flows; higher initial and operating costs.
Desiccant units – Have limited water removal capability due
to absorbing material; only removes air ingressed particles;
expensive compared to the volume of water removed.
Coalescer units – Removes free water only; has difficulty
breaking stable emulsions; does not work well in viscous fluids Start Stop
(>23cSt); much larger in size compared to PVS.

Estimated Water Removal Time


5000 ppm (0.5%) to 150 ppm (0.015%)
Reservoir Size (Litres)
0 5000 10000 15000 20000 25000 30000 35000
120

100
PVS185
Total Hours

80
PVS600
60
PVS 1200
40
PVS 1800
20
PVS 2700
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Reservoir Size (Gallons)

Parker Hannifin
Hydraulic Filter Division Europe
256 FDHB500UK.
PVS 185
Portable Purification Systems

Specification

Flow rate: Viscosity (max):


19 lpm (4.2 gpm). 108 cSt (500sus) – disposable.
Height: 460 cSt (2150 sus) – packed
1651mm (65”). tower.
Width: Outlet pressure (max):
825.5mm (32.5”). 4.1 bar (60 psi).
Length: Ports:
3/4” JIC (male) inlet.
1206.5mm (47.5”).
3/4” JIC (male) outlet.
Weight:
294.8 kg (650 lbs). FLA (full load amps):
Seal material: 15-41 amps.
Fluorocarbon (EPR opt.). (Depending on voltage used).
Condensate tank:
15.5 ltrs (3.4 gals).
Dispersal elements:
1.
Minimum operating capacity:
18.9 ltrs (4.2 gals).
Vacuum (max):
25 In/Hg.

Replacement elements PVS 185 flow diagram


Standard Coreless
Particulate 80CN-2
2QE (2 micron) 936716Q
5QE (5 micron) 936717Q
10QE (10 micron) 936718Q
20QE (20 micron) 936719Q
Option Coreless
Particulate IL8-3
2QE (2 micron) 933734Q
5QE (5 micron) 933612Q
10QE (10 micron) 933735Q
20QE (20 micron) 933736Q
Heater
Coreless
Disposable 933180
(Coalescing)
Packed tower 933553
(Cleanable)

Parker Hannifin
Hydraulic Filter Division Europe
257 FDHB500UK.
PVS 600
Portable Purification Systems

Specification

Flow rate: Viscosity (max):


38 lpm (8.3 gpm). 108 cSt (500sus) – disposable.
Height: 460 cSt (2150 sus) – packed
1638.3mm (64.5”). tower.
Width: Outlet pressure (max):
1117.6mm (44”). 4.1 bar (60 psi).
Length: Ports:
1549.4mm (61”). 1” JIC (male) inlet.
1” JIC (male) outlet.
Weight:
408.2 kg (900 lbs). FLA (full load amps):
24-38 amps.
Seal material: (Depending on options
Fluorocarbon (EPR opt.). & voltages).
Condensate tank:
15.5 ltrs (3.4 gals).
Dispersal elements:
2.
Minimum operating capacity:
22.7 ltrs (5.0 gals).
Vacuum (max):
25 In/Hg.

Replacement elements PVS 600 flow diagram


Standard Coreless
Particulate 80CN-2
2QE (2 micron) 936716Q
5QE (5 micron) 936717Q
10QE (10 micron) 936718Q
20QE (20 micron) 936719Q
Option Coreless
Particulate IL8-3
2QE (2 micron) 933734Q
5QE (5 micron) 933612Q
10QE (10 micron) 933735Q
20QE (20 micron) 933736Q
Coreless
Disposable 933180
(Coalescing)
Packed tower 933553
(Cleanable)

Parker Hannifin
Hydraulic Filter Division Europe
258 FDHB500UK.
PVS 1200
Portable Purification Systems

Specification

Flow rate: Viscosity (max):


76 lpm (16.7 gpm). 108 cSt (500sus) – disposable.
Height: 460 cSt (2150 sus) – packed
1651mm (65”). tower.
Width: Outlet pressure (max):
1117.6mm (44”). 4.1 bar (60 psi).
Length: Ports:
1549.4mm (61”). 11/2” NPTF inlet.
1” JIC (male) outlet.
Weight:
703.1 kg (1550 lbs). FLA (full load amps):
30-48 amps.
Seal material: (Depending on options
Fluorocarbon (EPR opt.). & voltages).
Condensate tank:
31.4 ltrs (6.9 gals).
Dispersal elements:
4.
Minimum operating capacity:
41.6 ltrs (9.1 gals).
Vacuum (max):
25 In/Hg.

Replacement elements PVS 1200 flow diagram


Dispersal
Disposable 933180
(coalescing)
Packed tower 933553
(cleanable)
Coreless IL8-3
02QE 933734Q
05QE 933612Q
10QE 933735Q
20QE 933736Q

Parker Hannifin
Hydraulic Filter Division Europe
259 FDHB500UK.
PVS 1800
Portable Purification Systems

Specification

Flow rate: Minimum operating capacity:


114 lpm (25 gpm). 68.1 ltrs (14.98 gals).
Height: Vacuum (max):
1651mm (65”). 25 In/Hg.
Width: Viscosity (max):
1066.8mm (42”). 108 cSt (500sus) – disposable.
Length: 460 cSt (2150 sus) – packed
1943.1mm (76.5”). tower.
Weight: Outlet pressure (max):
1156.7 kg (2550 lbs). 4.1 bar (60 psi).
Seal material: Ports:
Fluorocarbon (EPR opt.). 2” NPTF inlet.
1.5” JIC (male) outlet.
Condensate tank:
31.4 ltrs (6.9 gals). FLA (full load amps):
40-65 amps @ 460 V/60hz.
Dispersal elements:
8.

Replacement elements
Dispersal
Disposable 933180
(coalescing) PVS Specification Worksheet - Section 1
Packed tower 933553
Note: The following information will be required before a PVS order can be processed.
(cleanable)
Coreless IL8-3 1. Application..................................................................................................

02QE 933734Q 2. Fluid type......................................... Brand...............................................


05QE 933612Q Grade .............................................. Specific Gravity ................................
10QE 933735Q 3. Viscosity Min ........................... SUS/cSt @........................... °F/°C
20QE 933736Q Max........................... SUS/cSt @........................... °F/°C
Normal ...................... SUS/cSt @........................... °F/°C

4. Contamination level Current ISO level ___ /___ /___


Desired PPM level ___ /___ /___

5. Water concentration Current ISO level........................


Desired PPM level......................

6. Suction Head Positive/Negative ......................... Ft./metres....................

7. Operating distance ....................................... Ft./metres .........................

8. System fluid operating temperature: ............................................. °F/°C


Is there a cooler?..........................................................................

9. Operating environment air temperature: (air cooled model)


Min ....................................°F/°C
Max ...................................°F/°C
Normal...............................°F/°C

Parker Hannifin
Hydraulic Filter Division Europe
260 FDHB500UK.
PVS 2700
Portable Purification Systems

Specification

Flow rate: Minimum operating capacity:


170 lpm (37.4 gpm). 68.1 ltrs (14.98 gals).
Height: Vacuum (max):
1651mm (65”). 25 In/Hg.
Width: Viscosity (max):
1066.8mm (42”). 108 cSt (500sus) – disposable.
Length: 460 cSt (2150 sus) – packed
1943.1mm (76.5”). tower.
Weight: Outlet pressure (max):
1156.7 kg (2550 lbs). 4.1 bar (60 psi).
Seal material: Ports:
Fluorocarbon (EPR opt.). 3” NPTF inlet.
2” NPTF outlet.
Condensate tank:
31.4 ltrs (6.9 gals). FLA (full load amps):
50-70 amps @ 460 V/60hz.
Dispersal elements:
8.

Replacement elements
Dispersal
Disposable 933180
(coalescing)
Packed tower 933553 PVS Specification Worksheet - Section 2
(cleanable)
10. Water supply temperature: (liquid ring model)
Coreless IL8-3 Min ....................................°F/°C
Max ...................................°F/°C
02QE 933734Q
Normal...............................°F/°C
05QE 933612Q
10QE 933735Q 11. Operating environment above/below sea level: ........................ Ft./metres
20QE 933736Q
12. Voltage Options: 230Vac, 3p, 60Hz (185,600)
380Vac, 3p, 50Hz (185,600,1200,1800,2700)
460Vac,3p,60Hz (185,600,1200,1800,2700)
575vac, 3p 60Hz (185,600,1200,1800,2700)

13. Available amperage:....................................................................................

14. System volume: ..........................................................................................

15. Special requirements: .................................................................................


...................................................................................................................
...................................................................................................................
16. Any previous filtration problems with application:........................................

17. PVS model selected: ..................................................................................

Specification sheet must be completed before order can be entered

Parker Hannifin
Hydraulic Filter Division Europe
261 FDHB500UK.
PVS Range
Portable Purification Systems

Ordering Information

Product configurator
Select the desired symbol (in the correct position) to construct a model code.
Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8 Box 9 Box 10 Box 11
- PVS 600 460 DS D 5Q - 12 AC DFL

Box 1 Box 2 Box 3 Box 4


Seals Basic assembly Flow rate Power supply
Description Code Description Code Description Code Model Description Code
Fluorocarbon None Portable Purification System PVS 19 lpm (4.2 gpm) 185 380VAC, 3P, 50HZ 380
EPR E8 38 lpm (8.3 gpm) 600 185 460VAC, 3P, 60HZ 460
575VAC, 3P, 60HZ 550
76 lpm (16.7 gpm) 1200
380VAC, 3P, 50HZ 380
1800
600 460VAC, 3P, 60HZ 460
2700 550VAC, 3P, 60HZ 550
380VAC, 3P, 50HZ 380
1200 460VAC, 3P, 60HZ 460
550VAC, 3P, 60HZ 550
380VAC, 3P, 50HZ 380
1800 460VAC, 3P, 60HZ 460
550VAC, 3P, 60HZ 550
380VAC, 3P, 50HZ 380
2700 460VAC, 3P, 60HZ 460
550VAC, 3P, 60HZ 550

Box 5 Box 6 Box 7


Vacuum pump Dispersal element Particulate element μm (c)
Pressure setting Code Description Code Description Code
Dry sealed DS Disposable (coalescing) D 4 micron Microglass III 2Q
Liquid ring LR Packed tower (cleanable – 6 micron Microglass III 5Q
for use with viscious or P
10 micron Microglass III 10Q
highly contaminated fluids)
20 micron Microglass III 20Q
Note: Above elements are rated for Beta 200+ (99.5% efficiency)

Box 8 Box 9 Box 10 Box 11


Filter housing Heater Condenser Options
Description Code Model Description Code Description Code Description Code
80CN-2 None 185 12 KW (3 phase) 12 Air cooled Pneumatic wheels PW
IL8 (39”) Ecoglass III upgrade E 12 KW 12 Liquid cooled Auto condensate drain ACD
600
24 KW 24
Note: IL8 option is available on 185 and 600 Dirty filter light DFL
1200 24 KW 24
models, and is standard on 1200 models and Resetable hour meter RHM
1800 36 KW 36
larger
2700 48 KW 48 Sight flow indicator SFI
Inlet control valve ICV
CE marked CE
CSA marked CSA
Explosion proof EXP
(Class I, Division II, Zone I and II)
Note: For the icountPD option consult Parker
Filtration

Note 1: Contact parker for part number profile availability

Parker Hannifin
Hydraulic Filter Division Europe
262 FDHB500UK.

You might also like