PVS
PVS
Reduce the
catastrophic
results of water
contamination
Eliminate water from the
hydraulic system
www.parkerhfde.com
Parker Hannifin
Hydraulic Filter Division Europe
253 FDHB500UK.
PVS Series
Portable Purification Systems
Water is one of the most common and destructive Contaminated oil is drawn into the Parker portable
contaminants in a fluid system. When water purification system by a vacuum of 25 In/Hg. The
contaminates a system, it can cause serious oil passes through the in-line low watt density
problems such as: heater/s where the oil is heated to an optimum
temperature of 66°C (150°F).
Corrosion by etching metal
Fluid breakdown, reduction of lubricating The oil then enters the distillation column where it is
properties, additive precipitation, and oil exposed to the vacuum through the use of dedicated
oxidation dispersal elements. This increases the exposed
surface area of the oil and converts the water to
Reduced dielectric strength
a vapor form, which is then drawn through the
Abrasive wear in hydraulic components condenser by the vacuum pump. The vapour returns
to water and drops into the condensate holding tank
- this can then be drained off at a later stage.
Typical saturation points
Fluid type PPM % The water-free oil falls to the bottom of the vacuum
Hydraulic fluid 300 .03%
chamber and is passed through a final particulate
removal filter by a heavy duty lube oil pump.
Lubrication fluid 400 .04%
Transformer fluid 50 .005% Clean dry oil re-enters the reservoir/system via the
outlet port.
Free water occurs when oil becomes saturated
and cannot hold any more water. This water is
usually seen as cloudy oil or puddles of water
at the bottom of an oil reservoir. Water which is
absorbed into the oil is called dissolved water.
At higher temperatures, oil has the ability to hold
more water in the dissolved stage due to the
expansion of oil molecules. As the oil cools, this
ability reverses and free water will appear where
not visible before. In addition to temperature, fluid
type also determines the saturation point for your
system (see chart above).
250
% Bearing Life Remaining
200
150
100
50
0
% Water In Oil
Parker Hannifin
Hydraulic Filter Division Europe
254 FDHB500UK.
Applications for PVS Portable Purification Systems
Paper mills
- Dryer lubrication Low watt density
heater
- Hydraulic Air Cooled
Condenser
- Compressor lubrication Self diagnosing
controls include:
- Calenders Programmable
thermostat
Steel mills
Reverse pole switch/
- Bearing lubrication phase fail
% RH display
- Continuous casters
- Press roll lubrication
Condensate
Power generation holding tank
- Turbine oil
- Transformer oil Liquid level sight
glass
- EHC systems Vacuum pump
Industrial/aerospace
Caster wheels
- Test stands Forklift guides
- Machine tools
Parker Hannifin
Hydraulic Filter Division Europe
255 FDHB500UK.
PVS Series
Portable Purification Systems
Typical Performance
100
PVS185
Total Hours
80
PVS600
60
PVS 1200
40
PVS 1800
20
PVS 2700
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Reservoir Size (Gallons)
Parker Hannifin
Hydraulic Filter Division Europe
256 FDHB500UK.
PVS 185
Portable Purification Systems
Specification
Parker Hannifin
Hydraulic Filter Division Europe
257 FDHB500UK.
PVS 600
Portable Purification Systems
Specification
Parker Hannifin
Hydraulic Filter Division Europe
258 FDHB500UK.
PVS 1200
Portable Purification Systems
Specification
Parker Hannifin
Hydraulic Filter Division Europe
259 FDHB500UK.
PVS 1800
Portable Purification Systems
Specification
Replacement elements
Dispersal
Disposable 933180
(coalescing) PVS Specification Worksheet - Section 1
Packed tower 933553
Note: The following information will be required before a PVS order can be processed.
(cleanable)
Coreless IL8-3 1. Application..................................................................................................
Parker Hannifin
Hydraulic Filter Division Europe
260 FDHB500UK.
PVS 2700
Portable Purification Systems
Specification
Replacement elements
Dispersal
Disposable 933180
(coalescing)
Packed tower 933553 PVS Specification Worksheet - Section 2
(cleanable)
10. Water supply temperature: (liquid ring model)
Coreless IL8-3 Min ....................................°F/°C
Max ...................................°F/°C
02QE 933734Q
Normal...............................°F/°C
05QE 933612Q
10QE 933735Q 11. Operating environment above/below sea level: ........................ Ft./metres
20QE 933736Q
12. Voltage Options: 230Vac, 3p, 60Hz (185,600)
380Vac, 3p, 50Hz (185,600,1200,1800,2700)
460Vac,3p,60Hz (185,600,1200,1800,2700)
575vac, 3p 60Hz (185,600,1200,1800,2700)
Parker Hannifin
Hydraulic Filter Division Europe
261 FDHB500UK.
PVS Range
Portable Purification Systems
Ordering Information
Product configurator
Select the desired symbol (in the correct position) to construct a model code.
Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8 Box 9 Box 10 Box 11
- PVS 600 460 DS D 5Q - 12 AC DFL
Parker Hannifin
Hydraulic Filter Division Europe
262 FDHB500UK.