C-Tran Combined 3 Phase CT & Multifunction Transducer With Rs485 Output

The C-Tran is a 3-phase current transformer and multifunction power transducer with RS485 output. It can measure voltage, current, power factors and other electrical parameters. It has two communication ports that support Modbus and a fixed data format. The C-Tran can replace separate meters and current transformers with an all-in-one device. It can connect to multiple devices like PLCs and data loggers to monitor measurements.

Uploaded by

Nandha gopal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views

C-Tran Combined 3 Phase CT & Multifunction Transducer With Rs485 Output

The C-Tran is a 3-phase current transformer and multifunction power transducer with RS485 output. It can measure voltage, current, power factors and other electrical parameters. It has two communication ports that support Modbus and a fixed data format. The C-Tran can replace separate meters and current transformers with an all-in-one device. It can connect to multiple devices like PLCs and data loggers to monitor measurements.

Uploaded by

Nandha gopal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

C-TRAN COMBINED 3 PHASE CT

& MULTIFUNCTION TRANSDUCER


WITH RS485 OUTPUT
DESCRIPTION
The C-Tran is combined 3 phase multifunction AC
Power transducer and 3 phase current transformer.
The C-Tran is fully programmable through either of
the two communication ports

APPLICATION
The C-Tran can replace traditional multifunction
meters and 3 separate current transformers with an
all in one combined product with RS485 output

PARAMETERS MEASURED MEMORY


• Phase Voltage (V) All data including energy registers, current and voltage
• Line Voltage (V) ratios and calibrated data is stored in a non volatile
• Phase Current (I) eeprom.
• Frequency (Hz)
• Active Power Per Phase (W) CUMMUNICATION
• System Active Power (W)
• Reactive Power Per Phase (VAr) Port 2:
• System Reactive Power (VAr) The main communication port.
• Apparent Power Per Phase (VA)
• System Apparent Power (VA) It uses the popular Modbus protocol to retrieve
• Import Active Power (W.h) measurements and to change the transducers operating
• Import Reactive Power (VAr.h) parameters. It enables the connection of a host
• Apparent Energy (VA.h) computer, PLC, RTU, Data Logger etc.
• System Power Factor (P.F.)
• Amp Demand (Ad) Port 1:
• Maximum Amp Demand (Max.Ad) This port has a fixed data format, It can also retrieve
• Import Watt Demand (Wd) measurements and set the transducer operating
• Maximum Watt Demand Import (Max.Wd) parameters. Only the baud rate and endian format can
• VA Demand (VAd) be changed on this port.
• Maximum VA Demand (Max. VAd)
• Neutral Current Can connect with M850-LCM display with this port
• Hours Run—Voltage based
PROGRAMMING
ACCURACY Setup and monitoring software is available from
The accuracy of the C-Tran is Class 0.2 to IEC688 over Our website www.hobut.co.uk
the range 10% to 120% In, and for voltages from
100V to 120% of nominal input.
For Active and Reactive energy the accuracy is 1% of
the reading to IEC 1036.
The accuracy of the current transformer is Class 1 for
the range 10% to 120% of nominal input.

Our policy is one of continuous development and therefore specifications may change without notice.

Howard Butler Ltd. www.hobut.co.uk


Page 1 of 3
C-TRAN COMBINED 3 PHASE CT
& MULTIFUNCTION TRANSDUCER
WITH RS485 OUTPUT
INSTALLATION OPTIONS
OPTION 1
2)
5(
RS 4
8 Multiple C-Trans can be connected to PC, PLC, RTU,
Data Loggers and Scada System with RS485 (Modbus)
without the need odf a display

ve
ste
r Sla
Ma

ve
Sla
OPTION 2
ve
Sla Multiple C-Trans with single display.

1 Up to 32 C-Trans can be linked together with one


single display (Display Part No. M850-LCM)

r
ste
85
(1)
Sla
ve Ma OPTION 3
RS4
Multiple C-Trans with single display.
ve
Sla

ve
(As Option 2) with RS485 remote communication
Sla
(Display Part No. M850-LCM)

C-TRAN RANGE
CURRENT PART NUMBER
ste
r 60A C-TRAN-60A
Ma
(1) 100A C-TRAN-100A
85
(2) RS4 lave
85 S
ste
r
RS4 125A C-TRAN-125A
Ma
ve 150A C-TRAN-150A
Sla
ve Sla
160A C-TRAN-160A
ve
ve Sla C-TRAN-200A
Sl a 200A
ve 250A C-TRAN-250A
Sla

OPTION PART NUMBER


3 Remote Dispaly M850-LCM

Our policy is one of continuous development and therefore specifications may change without notice.

Howard Butler Ltd. www.hobut.co.uk


Page 2 of 3
C-TRAN COMBINED 3 PHASE CT
& MULTIFUNCTION TRANSDUCER
WITH RS485 OUTPUT
GENERAL SPECIFICATION DIMENSIONS (mm)
INPUT 105

Rated Un Directly connected Voltages:


(3ph4W) 100V to 330V L-N Max
(3ph3W) 100V to 440V L-L Max
Rated In Depand on CT primary (see options)
Range 10 to 120% In 105 21
Overload Absolute maximum input: 4 x In
Frequency 50/60Hz Nominal range 45/65Hz 25

14
OPTIONS
35 35
3 Phase current available options:
60A, 100A, 125A, 150A, 160A, 200A & 250A

ACCURACY
Specified @ 23 °C 100V –100%Un, 10%-100% In 59
Parameters unless stated Class 0.2 to IEC688
Frequency Class 0.1Hz to IEC688 10
15
Power Factor Class 0.5 to IEC688
Active & Reactive Energy 1.0% of reading IEC1036 34
Current Transformer Class 1 to IEC 60044-1

INSULATION
Test Voltage 4kV RMS 50Hz for 1 min
Voltage inputs to case
CONNECTION DIAGRAMS
3kV RS485 to case and voltage L3
Input B (+)

PART 1
L2
(there is no isolation between A (-)
L1
Port 1 and Port 2) Screen
N
Impulse Test EMC 5kV transient complying B (+)

PART 2
C-TRAN
With IEC 801.EN 55020 HF L1
A (-)
Screen
L2
APPLIED STANDARD
L3
General IEC 688, BSEN 60688
BS 4889, IEC 359
Immunity EN 61326-2 3 Phase 3 Wire Unbalanced Load
Safety EN 61010—1
L3
B (+)
PART 1

L2
APPROVALS A (-)
UL, C-UL Pending L1 Screen
N B (+)
PART 2

C-TRAN
AUXILIARY A (-)
L1
Self powered maximum 440V Screen
Burden <10VA L2
L3
ENVIRONMENTAL N
Working Temperature 0 to +60 °C
Storage Temperature -30 to +65 °C 3 Phase 4 Wire Unbalanced Load
Temperature Coefficient 0.01% per °C

Our policy is one of continuous development and therefore specifications may change without notice.

HOWARD BUTLER LTD Page 3 of 3

CROWN WORKS, LINCOLN ROAD


WALSALL WS1 2EB ENGLAND
August 2015

Tel: 01922 640003 Fax: 01922 723626


International Tel: +44 1922 640003 E-mail: [email protected]
http://www.hobut.co.uk

You might also like