0% found this document useful (0 votes)
271 views6 pages

Instrumentation Drawings: Submitted by

The document provides instrumentation drawings for pressure indicators of two types: bourdon type and diaphragm seal type. It includes labeled diagrams of the pressure indicator hookups for both types, with notes explaining that screw-threaded valves will be used to connect pressure gauges and that liquid services will tap from the side of pipes while air/gas services will tap from the top.

Uploaded by

smith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
271 views6 pages

Instrumentation Drawings: Submitted by

The document provides instrumentation drawings for pressure indicators of two types: bourdon type and diaphragm seal type. It includes labeled diagrams of the pressure indicator hookups for both types, with notes explaining that screw-threaded valves will be used to connect pressure gauges and that liquid services will tap from the side of pipes while air/gas services will tap from the top.

Uploaded by

smith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Instrumentation Drawings

Submitted By:
NOTE:
1. * SCREWED VALVE BSP 34" THREADED
FOR PRESSURE INDICATOR-BOURDON
TYPE AND * SCREWED VALVE BSP 1 21"
THREADED FOR PRESSURE
INDICATOR-DIAPHRAM SEAL TYPE.
2. TAPPING CONNECTION OF PRESSURE
GUAGES FOR LIQUILD SERVICES WILL
BE FROM SIDE OF THE PIPE AND FOR
AIR / GAS SERVICE WILL BE FROM TOP
OF THE PIPE.
INSTRUMENT HOOKUP DRAWING FOR PRESSURE INSTRUMENT HOOKUP DRAWING FOR PRESSURE
INDICATOR-BOURDON TYPE INDICATOR-DIAPHRAM SEAL TYPE

1
1 7 7

2
3 10 10
3
2

8 8
5 5

INST SCOPE

INST SCOPE
PIPING SCOPE

PIPING SCOPE
9 9
4 3 4 3

11 11
INST SCOPE 6 INST SCOPE 6
PIPING SCOPE PIPING SCOPE

DRAIN DRAIN
DRAIN DRAIN

VERTICAL VERTICAL
HORIZONTAL HORIZONTAL

BILL OF MATERIAL BILL OF MATERIAL


ITEM NO. QTY. UNIT SIZE DESCRIPTION MATERIAL ITEM NO. QTY. UNIT SIZE DESCRIPTION MATERIAL
01 & 07 01 NOS. 1
2" NPT (M) PRESSURE GAUGE SS304 01 & 07 01 NOS. 1" NPT (M) PRESSURE GAUGE SS304
1
02 & 08 01 NOS. 2" F X 21" F X 21" F EQUAL TEE SS304 02 & 08 01 NOS. 1" F X 1" F X 1" F EQUAL TEE SS304
1
03 & 09 02 NOS. 2" M X 21" M THREADED NIPPLE SS304 03 & 09 02 NOS. 1" M X 1" M THREADED NIPPLE SS304
3
04 & 10 01 NOS. 4 " BSP THREADED X 21" NPT (M) THREADED REDUCER NIPPLE SS304 04 & 10 01 NOS. 1 1/2 " BSP THREADED X 1" NPT (M) THREADED REDUCER NIPPLE SS304
1
05 01 NOS. 2" F X 21" F L BEND SS304 05 01 NOS. 1" F X 1" F L BEND SS304
1
06 & 11 02 NOS. 2" F X 21" F GATE VALVE SS304 06 & 11 01 NOS. 1" F X 1" F GATE VALVE SS304

1. ALL DIMENSIONS ARE IN METRES


UNLESS OTHERWISE NOTED.
Project: Sheet Title:
Atal Mission For Rejuvenation and Urban Transformation No. Date
REVISIONS
Descriptions Revision by
ISSUED BY DESIGN CELL FOR
Drawn By TYPICAL INSTALLATION DRAWING OF PRESSURE
S.M
Client: PDMC R0 10-01-2019 APPROVAL DETAILED PROJECT REPORT GOOD FOR CONSTRUCTION GAUGE
MISSION DIRECTOR, AMRUT EPTISA SERVICIOS DE INGENIERIA, DATE : DATE : DATE : Project No:-
URBAN DEVELOPMENT DEPARTMENT S.L & EPTISA INDIA PVT. LTD.
Design By FOR TENDER PURPOSE ONLY
EP-04
DISPUR, ASSAM M.R

FEASIBILITYY REPORT TENDER MISCELLANEOUS Drawing No.:

DATE : DATE : 22/01/2019 DATE : Approved By


AMRUT/NG/DPR/WTP/SD/I-001
Date: Scale:
S.L
22.01.2019 N.T.S
B2 DIN HOUSING BRACKET DETAILS NOTE:
INSTALLATION OF HOOKUP DRAWING FOR PRESSURE
DETAIL-A (OPTION-1 FOR WALL MOUNTING)
TRANSMITTER 1

SINGLE CABLE
6

4
1

2
3
DETAIL-A
2

MOUNTING ARRANGEMENT 4
ITEM
DESCRIPTION
NO.
01 U-BOLT
INSTRUMENT 3
1
2" NPT F 02 U- BOLT FIXING BOLT AND WASHERS

03 TRANSMITTER FIXING BOLTS

VENT 04 B2 BRACKET
ISOLATE

B1 AND B2 BARREL HOUSING BRACKET DETAILS


DETAIL-A (OPTION-2 FOR PIPE MOUNTINGP)
1
1
2"NPT F
PROCESS 3
2 WAY VALVE MANIFOLD 4

3
4" BSP TH GATE VALVE DRAIN
5

1 2

5 4
PIPNG INST.

ITEM QTY. UNIT SIZE DESCRIPTION MATERIAL


NO.
ITEM
01 01 NO. 1
2" NPT (F) PRESSURE TRANSMITTER - DESCRIPTION
NO.
02 1 1
05 NOS. 2 " NPT (M) X 2" OD MALE CONNECTOR SS304L 01 U-BOLT
03 01 1 2 WAY MANIFOLD
NO. 2" OD SS304 02 U- BOLT FIXING WASHERS AND NUTS
AR 1 IMPULSE PIPE SS304
04 MTR. 2" OD 03 TRANSMITTER FIXING BOLTS
3
05 01 NO. 4" BSP TH X 21" NPT (F) TH NIPPLE NIPPLE SS304 B1 AND B2 BRACKET
2 04
06 AR MTR. 40 NB PVC CONDUIT -- PVC FITTING ADAPTER ( SUPPLIED WITH 266HSH)
05 1. ALL DIMENSIONS ARE IN METRES
07 01 NO. AS PER SITE REQUIREMENT ENCLOSER - UNLESS OTHERWISE NOTED.
Project: Sheet Title:
Atal Mission For Rejuvenation and Urban Transformation No. Date
REVISIONS
Descriptions Revision by
ISSUED BY DESIGN CELL FOR
Drawn By INSTALLATION OF HOOKUP DRAWING FOR
S.M
Client: PDMC R0 10-01-2019 APPROVAL DETAILED PROJECT REPORT GOOD FOR CONSTRUCTION PRESSURE TRANSMITTER
MISSION DIRECTOR, AMRUT EPTISA SERVICIOS DE INGENIERIA, DATE : DATE : DATE : Project No:-
URBAN DEVELOPMENT DEPARTMENT S.L & EPTISA INDIA PVT. LTD.
Design By FOR TENDER PURPOSE ONLY
EP-04
DISPUR, ASSAM M.R

FEASIBILITYY REPORT TENDER MISCELLANEOUS Drawing No.:

DATE : DATE : 22/01/2019 DATE : Approved By


AMRUT/NG/DPR/WTP/SD/I-002
Date: Scale:
S.L
22.01.2019 N.T.S
NOTE :
1. QUANTITY SHOWN BELOW IS FOR ONE
INSTRUMENT
2. SUITABLE GASKET,BOLTS & NUTS SHALL
BE PROVIDED BY ERECTION
CONTRACTOR.
3. MOUNTING ACCESSORIES IS REQUIRED
4. PROTECTIVE SUNSHADE AND MOUNTING
ACCESSORIES IS REQUIRED.

TYPICAL INSTALLATION DRAWING FOR RADAR TYPE LEVEL TRANSMITTER


TRANSMITTER

(TOP MOUNTED)
1
2
2 12",FLANGE 150#

INSTRUMENTATION

PIPING
SUMP / OHR /GLR

2 01 2 1/2" ANSI 150# FLANGE SS316 BOLTS & NUTS SUITABLE FOR 2 1/2" INST SCOPE
1 01 2 1/2" PTFE GASKETS SUITABLE FOR 2 1/2" ANSI CLASS INST SCOPE
SCHEDULE
PART DESCRIPTION REMARKS
QUANTITY SIZE OR MATERIAL
No. RATING

1. ALL DIMENSIONS ARE IN METRES


UNLESS OTHERWISE NOTED.
Project: Sheet Title:
Atal Mission For Rejuvenation and Urban Transformation No. Date
REVISIONS
Descriptions Revision by
ISSUED BY DESIGN CELL FOR
Drawn By TYPICAL INSTALLATION DRAWING FOR
S.M
Client: PDMC R0 10-01-2019 APPROVAL DETAILED PROJECT REPORT GOOD FOR CONSTRUCTION RADAR TYPE LEVEL TRANSMITTER
MISSION DIRECTOR, AMRUT EPTISA SERVICIOS DE INGENIERIA, DATE :
DATE : DATE : Project No:-
URBAN DEVELOPMENT DEPARTMENT S.L & EPTISA INDIA PVT. LTD.
Design By FOR TENDER PURPOSE ONLY
EP-04
DISPUR, ASSAM M.R

FEASIBILITYY REPORT TENDER MISCELLANEOUS Drawing No.:

DATE : DATE :10/01/2019 DATE : Approved By


AMRUT/NG/DPR/WTP/SD/I-003
Date: Scale:
S.L
22.01.2019 N.T.S
TYPICAL CHAMBER DRAWING FOR ELECTROMAGNETIC FLOWMETER DETAIL-B:INSTALLATION DRAWING NOTE :-
FOR FLOW TRANSMITTER 1. Consider 5 to 7mm gasket for every
joints of each flowmeter
RCC CABIN
1500 TYPICAL INSTALLATION ARRANGEMENT DRAWING FOR 2. The Tap Angle for each Pipe (Reducer
& Expander) shall be finalized during
BORE ELECTROMAGNETIC FLOWMETER detailed design engineering based on
TRANSMITTER DETAIL-A:INSTALLATION DRAWING FOR FLOWMETER 06 the Recommendation of Manufacturer
(OPTIONAL) for achievement of better Accuracy.
02 3. RCC Structure shall be constructed for
1500

CANOPY
POWER CABLE FROM TRANSMITTER pipe support at both ends of flowmeter.
D.I VENTILATED MANHOLE SINGNAL CABLE TO TRANSMITTER
COVER AND FRAME Ø 600 SIGNAL CABLE 4. AR deffers as required.
3 SIGNAL CABLE FROM FLOW
900 D.I./C.I. PIPE GROUNDING RINGS WITH LUGS AND WIRES FROM PLC SENSOR
1 2 1 D.I./C.I. PIPE
300 225 2
05 05

200

R.C.C. M20

INLET →
OUTLET POWER CABLE
POWER CABLE
16Ø MS RUNGS PVC 200 TO FLOW
FROM PDB
ENCAPSULATED SENSOR
>=5D >=3D
1800

200 Ø C/C
TANKING 03

CRIPLING FLANGE
04
D

07
PIL
600

CONCRETE SUPPORT
200 x 200 x 300

300
BOQ FOR DETAIL-A :
PCC SR
NO DESCRIPTION MATERIAL QTY / FLOWMETER

150
150 300 L 300 150 1 C.I.D JOINT C.I. 2
150 150
SECTION A-A 2 DRUM PIECE WITH ONE END FLANGE M.S. 2
3 ELECTROMAGNETIC FLOWMETER 1
CONCRETE SUPPORT
300 x 300 x 500 R.C.C. C30/20/S
PCC C20/20/S
TRANSMITTER BOQ FOR DETAIL-B :
300

CRIPLING ITEM NO. QTY. DESCRIPTION


FLANGE
FLOWMETER 2 01 FLOW TRANSMITTER

A 2" GI PIPE
3 1.2
B

4 04 ANCHOR BOLT 100mm

5 AR PVC CONDUIT
A
6 01 ENCLOSURE
300

7 01 BASE PLATE 120x120x6mm


16 Ø MS RUNGS PVC 300 B 300
ENCAPSULATED
@200C/C SECTION PLAN B-B
FLOWMETER SIZE (mm)
SR.NO PIPE DIA (mm) L (mm) B (mm) H (mm)
80 100 150 200 250 300 350 400
1 80 2100 2100 1680
2 100 2150 2100 1700 DRUM PIECE
450 450 600 600 750 750 900 900
LENGTH (mm)
3 150 2500 2500 1750 DRUM PIECE
6 6 6 6 6 6 6 6
4 200 2550 2500 1800 THICKNESS (mm)
5 250 3450 3000 1850 DRUM PIECE
80 100 150 200 250 300 350 400
DIA (mm)
6 300 3900 3600 2200
7 350 4500 4200 2500
1. ALL DIMENSIONS ARE IN METRES
8 400 5000 4800 2800 UNLESS OTHERWISE NOTED.
Project: Sheet Title:
Atal Mission For Rejuvenation and Urban Transformation No. Date
REVISIONS
Descriptions Revision by
ISSUED BY DESIGN CELL FOR
Drawn By TYPICAL INSTALLATION DRAWING OF
S.M
Client: PDMC R0 10-01-2019 APPROVAL DETAILED PROJECT REPORT GOOD FOR CONSTRUCTION ELECTRO MAGNETIC FLOW METER
MISSION DIRECTOR, AMRUT EPTISA SERVICIOS DE INGENIERIA, DATE : DATE : DATE : Project No:-
URBAN DEVELOPMENT DEPARTMENT S.L & EPTISA INDIA PVT. LTD.
Design By FOR TENDER PURPOSE ONLY
EP-04
DISPUR, ASSAM M.R

FEASIBILITYY REPORT TENDER MISCELLANEOUS Drawing No.:

DATE : DATE : 22/01/2019 DATE : Approved By


AMRUT/NG/DPR/WTP/SD/I-004
Date: Scale:
S.L
22.01.2019 N.T.S
TYPICAL SYSTEM ARCHITECTURE DRAWING FOR SCADA ROOM AT RESPECTIVE WTP
(EXISTING & PROPOSED) INCLUDING 1NO. OF INTERMEDIATE PUMPING STATION
WIRELESS DATA
TRANSMISSION

YAGI VIA GPRS


ANTENNA
OPERATOR WORK STATION

GPRS SCADA cum PRINTER


WIRELESS ENGINEERING
GATEWAY LEASER

LEGENDS :
PLC - PROGRAMMING LOGIC
CONTROLLER
ETHERNET SWITCH GPRS - GENERAL PACKET RADIO
SERVICE
NOTES :
1.PLC SHALL OPERATE IN STAND
STANDALONE PLC
ALONE CONFIGURATION ALONG WITH
SCADA SYSTEM.
CONTROL(DIGITAL) CABLES

2.THE TYPICAL DIMENSION OF


INSTRUMENTATION CONTROL PANEL
SHALL BE {1200mm(L) X1000mm(W) X
2000mm(H)} AND THE SAME SHALL BE
INSTALLED IN SEPARATE ISOLATED
PARTITION IN SCADA ROOM (PLEASE
REFER CHEMICAL BUILDING LAYOUT)
J.B J.B J.B J.B J.B J.B

3.THE TYPICAL DIMENSIONAL


REQUIREMENT OF SCADA ROOM
SHALL BE {2500mm(L) X2500mm(W) X
M.C.C / L.T PANELS 2000mm(H)}

TYPICAL FIELD TRANSMITER / SENSOR

1. ALL DIMENSIONS ARE IN METRES


UNLESS OTHERWISE NOTED.
Project: Sheet Title:
Atal Mission For Rejuvenation and Urban Transformation No. Date
REVISIONS
Descriptions Revision by
ISSUED BY DESIGN CELL FOR
Drawn By SYSTEM ARCHITECTURE DRAWING FOR SCADA ROOM
S.M
Client: PDMC R0 10-01-2019 APPROVAL DETAILED PROJECT REPORT GOOD FOR CONSTRUCTION AT WTP (EXISTING & PROPOSED)
MISSION DIRECTOR, AMRUT EPTISA SERVICIOS DE INGENIERIA, DATE : DATE : DATE : Project No:-
URBAN DEVELOPMENT DEPARTMENT S.L & EPTISA INDIA PVT. LTD.
Design By FOR TENDER PURPOSE ONLY
EP-04
DISPUR, ASSAM M.R

FEASIBILITYY REPORT TENDER MISCELLANEOUS Drawing No.:

DATE : DATE : 22/01/2019 DATE : Approved By


AMRUT/NG/DPR/WTP/A/GN-001
Date: Scale:
S.L
22.01.2019 N.T.S