0% found this document useful (0 votes)
154 views9 pages

Techinical Specifications Lovely

This document outlines the technical specifications and materials for a proposed one-storey residential building in Digos City. It includes 9 sections that specify the general materials and workmanship, site work, concreting, structural steel, masonry, lumber, waterproofing, hardware, and roofing works. The specifications define the required concrete mixtures, reinforcing bars, hollow blocks, wood species, waterproofing systems, hardware brands, and roofing materials to be used in the construction of the building over a 180 calendar day contract duration.

Uploaded by

Tyn Maturan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views9 pages

Techinical Specifications Lovely

This document outlines the technical specifications and materials for a proposed one-storey residential building in Digos City. It includes 9 sections that specify the general materials and workmanship, site work, concreting, structural steel, masonry, lumber, waterproofing, hardware, and roofing works. The specifications define the required concrete mixtures, reinforcing bars, hollow blocks, wood species, waterproofing systems, hardware brands, and roofing materials to be used in the construction of the building over a 180 calendar day contract duration.

Uploaded by

Tyn Maturan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING

Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

1 GENERAL

A.1.0 Materials and workmanship deemed necessary to complete the works, but
not specifically mentioned in the specifications, working drawing, or in other Contract
Document, shall be supplied by the Contractorwithout extra cost to the Owner. Such
materials shall be of the highest quality available, and installed or applied in a
workmanlike manner as prescribed at appropriate locations.

A.2.0 Materials and finishes for on-site improvements and facilities as listed below re
part of the Scope of Work and shall be supplies and installed by the contractor;

a. Demolition, clearing and site grading works in preparation for construction


b. Constrction of:
1. Curbs and Trenches, walks, ramps, steps, and miscellaneous slabs.
2. Septic Vault, manhole yard basins, trenches

A.3 For soil poisoning use "Dursban Premium" mixed with potable water applied on
excavation for foundation and footing; slab on fill bed and with the area of the
proposed building and extended about one meter from the building line perimeter;
follow mixing porportion on manufacturer's label.

2 SITE WORK

Earthworks
Fill or barrow materials granular non-plastic materials, inert materials from off site
source.
Excavated materials use as back fill, approved and clean materials. Free of stones not
larger than 50mm Ø (2”Ø), roots, and organic matter.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 1 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

3 CONCRETING

Concrete Formworks - use 10mm (3/8" thk) Plywood

Concrete Steel Reinforcement - as manufactured by the National Steel Coporation or


its equivalent (Conforming to ASTM standard):

Intermediate Grade Steel - Grade 23

Cast-in Concrete: Cement - Holcim Cement of its equivalent. Use one (1) brand for
whole structural and masonry works.

Aggregates:
Gravel - clean, washed, gravel use 1 1/2 mazimun for slabs and 19mm Ø
(3/4") for columns and slabs
Sand - clean, washed
Water - foir for drinking, free from injurious amount of oil, acid, alkali,
organic materials.

Concrete Mixture: N.A.


Class A - 1:2:3 - 20.7 Mpa (2,500psi) for slabs on fill grade.

Concrete Admixures:
Air-training Admixture: DAREX-AEA or approved equal to improve workablility
or durability of concrete mixes.
Integral Water Proofing Hydratite WR approved equal. (As necessary)
Concrete Bond - Drawled C or Approved equal for binding new to old concrete,
repair of cracks or bonding grout.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 2 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

4 STRUCTURAL STEEL

Plates, sheets and connectors: from mild steel sheet or plate with thickness, size,
shape and design as indicated in the drawing for miscellaneous stiffener, bearing
anchorage, connector or straps.

Standard solid Sections: mild steel angles, flat bars, square bars, channels, U and
other sections. Cee-purlins for roof framing, for overhead anchorage of folding doors,
grillwork, for miscellaneous fabricated mounting brackets, scraps, dowels, framed and
connectors.

Bolt Accessories: low carbon steel with type, shape, size, threading corresponding nut
and accessories as required.

Bracing Rods: standard structural grade steel rods with turnbuckles whenever
required for footing framing.

Welding Electrodes: approved for manual shielded metal are welding as required. E-
6013 series of structural welding.

5 MASONRY

Concrete hollow blocks (C.H.B): Use 150mm (6”) and 100mm (4") thickness machine-
made C.H.B. 350 psi on exterior and interior walls as indicated in the plans. Use also
for septic vaults, catch basin and grease trap.

Reinforcing bars: bars and tie wire: See C.00 and as indicated in the plan

Mortar and Plaster Works: Consisting of scratch and finish coat, both consisting of
one (1) part Wallright cement and two (2) coat part of clean, washed sand, measured
by volume.
For all interior masonry surfaces to be painted, where called for in the drawing and
where plastering is essentials to complete the work.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 3 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

6 LUMBER

Yacal species shall be used for the following specified wooden items whenever there
is a need for such item in this project;
a.) Door frames, and headers – 50 x 100mm thk. S4S kiln dried.
b.) Wood plates and shims.
c.) All wood in contact with concrete and masonry surface.
d.) Structural wood such as stair treads, use 50 x 350 mm thk. Tanguile Specie S4S Kiln
Dried. Apply with surface preparation, methods of application and density as per
manufacturer’s specifications.

7 WATER PROOFING

Waterproofing: by REBTECH Enterprises (Hygard Water Proofing System


(Capillary/Osmosis): Installation of waterproofing materials shall be as per
manufacturer specifications.

Integral Waterproofing: Hydratite WR or Sahara.

8 HARDWARES (DEFER)

a.) Locks and Latches – use yale brand made in U.S.A. b.) Hinges – use Stanley 4” x 4”
brass finish
c.) Locks – use yale locks for drawer and cabinet doors.
d.) Cabinets/Closet door pulls and handles – Tentori or approved equivalent
e.) Nails - use PAG-ASA brands.
f.) Wood Screws - use standard metal manufacturing co.
g.) Machine Bolts – use standard metal manufacturing co.

9 ROOFING WORKS

a.) Use Ga. no 26 Rib Type long span, pre-painted roofing sheets. Provide 6mm thk.
double sided foil P.E. insulation.
b.) Use Ga. 24 preformed, pre-painted G.I. gutter by Southern Metal Steel
Corporation (SMSC).

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 4 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

10 FINISHES

10.1 FLOOR FINISHES

MARK DESCRIPTION LOCATION


FF-1 600MMX600MM Granite tiles, polshed finish living area, dining area, kitchen
FF-2 600MMX600MM Granite tiles, matte finish laundry area, t&b, walk-in pantry
FF-3 900MMX100MM Ceramic tiles porch
FF-4 Rough cement finish back stairs
FF-5 1200mmx200mm Synthetic Wood tiles master bedroom, bedrooms 1,2,3

10.2 WALL FINISHES

MARK DESCRIPTION LOCATION


20CM X 40XM X 15CM thk. CHB exterior wall with
WF-1 Exterior Walls
smooth cement finish, painted white
20CM X 40XM X 15CM thk. CHB exterior wall with
WF-2 Accent Exterior Walls
syntheric wood finish
20CM X 40XM X 10CM thk. CHB wall, smooth
WF-3 Interior Walls
cement finish, painted white
20CM X 40XM X 15CM thk. CHB exterior wall with
WF-4 Accent Exterior Walls
stucco finish

10.2 CEILING FINISHES

MARK DESCRIPTION LOCATION


3.5MM Thk. Fiber Cement board on metal furring
CF-1 Interior Ceiling System
ceiling system
Synthetic wood plank ceiling system on metal Interior Ceiling System
CF-2
furring ceiling system (Living Area)
CF-3 PVS Soffits or approved equivalent Eaves

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 5 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

11 GLASS AND ALUMINUM

11 Use 6mm thk. Glass on Wood Grain Aluminum Casement Window Frame. (See
schedule of Windows).

11 Use 6mm thk. Glass on Wood Grain Aluminum Awning Window Frame. (See
schedule of Windows).

11 Use 6mm thk. Glass on Wood Grain Aluminum Fixed Window Frame w/
Casement Panel. (See schedule of Windows).

11 Use 6mm thk. Glass on Wood Grain Aluminum Fixed Window Frame w/
Casement Panel. (See schedule of Windows).

12 Use 6mm thk. Glass on Wood Grain Aluminum Sliding Door Frame. (See
schedule of Doors).

12 PAINTING AND VARNISHING WORKS (defer)


Use Boysen Paint products by Pacific Paints

13 ELECTRICAL

a.) For all electrical wiring use Philflex, Columbia or approved equivalent. No
conductor shall be less than AWG

b.) For all conduit works use PVC conduit pipes Moldcon PNS 14 or approved
equivalent

c.) For switches and convenience outlet utility and junction boxes use Fumaco, G.I.
sheet G.A. 16 sizes and shapes as required.
d.) For switches and C.O. receptacles use flush type sockets & switches, white color:
National Wide Series brand or approved equivalent.
e.) For fluorescent lamps and ballast, use box type Philips or General Electric brands
with rapid start sound rated, high power factor ballast.

f.) For incandescent bulbs, use Philips or General Electrical brands.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 6 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

13 ELECTRICAL

a.) For all electrical wiring use Philflex, Columbia or approved equivalent. No
conductor shall be less than AWG

b.) For all conduit works use PVC conduit pipes Moldcon PNS 14 or approved
equivalent

c.) For switches and convenience outlet utility and junction boxes use Fumaco, G.I.
sheet G.A. 16 sizes and shapes as required.
d.) For switches and C.O. receptacles use flush type sockets & switches, white color:
National Wide Series brand or approved equivalent.
e.) For fluorescent lamps and ballast, use box type Philips or General Electric brands
with rapid start sound rated, high power factor ballast.

f.) For incandescent bulbs, use Philips or General Electrical brands.

g.) For circuit breaker use General Electrical or Square D brand or approved
equivalent. With Nema casing or approved equal, gauge 16 bolt on type, pre-painted,
surface mounted with latch lock.

h.) Telephone Systems – Philflex, Columbia wire number 22/4c conductor telephone
jacketed wire.

i.) Permit and fees – All permits, fees, processing of MERALCO transformer
connection and other insurances shall
be the responsibility of the contractor.

j.) Guarantee and Warranty – The Contractor shall guarantee all materials supplied
and his work to be free from
factory and workmanship for a period of one year.

Any material found to be defective during this time shall be replaced by the
contractor free of charge.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 7 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

14 PLUMBING

a.) Use “Sanimold Extra” UPVC sanitary pipes distributed by Moldex Products
Incorporated for all soil and Waste
pipes; use PVC cement for all joints.

b.) Use 20mm (12mm inside diameter) to 25mm (19mm inside diameter) PN20 PPR
Wavin Ekoplastik or approved equivalent for hot and cold water lines & exposed
water distribution pipes.

c.) Use 75mm to 100mm Ø “Sanimold Extra” UPVC sanitary pipes for all rain
leader/downspouts.

d.) Use “Kakubai” (Japan) brand steel floor drain with size as specified on drawing.
O.S.M.

e.) For drainage pipes use 50mm to 100mm Ø. “Moldex” HDPE pipes and concrete
hollow block catch basins as
shown on plans and drawings.

f.) Sanitary Disposal Systems


Pipes: 50mm to 100mm Ø “Sanimold Extra” UPVC pipes provide cleanout at 6000mm
span and fitting for vent and
waste lines leading to septic vault.
Floor Drains: “Metma” or its equivalent, 100mm x 100mm (4”x4”) for toilets and
where so indicated in the drawings.
-O.S.M.
Clean-out Plugs: cast brass ferrule with countersunk tap screw cover, for all drain and
sewer lines requiring clean- outs.

Storm Drainage Systems


Pipes: 150mm-200mm dia. Reinforced Concrete Pipes.
Catch Basin, area drains and manholes: pre-cast reinforced slabs, details as shown in
the drawings.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 8 3/1/2021


Project Title: PROPOSED ONE-STOREY RESIDENTIAL BUILDING
Location: LOT 9, BLOCK 124 MABINI EXTENSION, ZONE III, DIGOS CITY
Owner: MS. LOVELY B. ORONG
Subject: TECHNICAL SPECIFICATIONS AND FINISHED DIGEST
Contract Duration: 180 c.d.

14 PLUMBING

Comfort Room Fixtures- O.S.M.


h.1) For water closets
- Use American standard for all toilets.
h.2) For Lavatories
- Use American standard wall hung type for all toilets.
⦁Paper Holder - use American standard toilet paper holder.
⦁ Water Closet Tank Fitting – use Braded type (U.S brand)
⦁ Water Closet angle Valve – use Schell angle valve or any equivalent U.S. Brand
⦁ Lavatory P-trap Assembly – use Price Pfister or any equivalent (U.S. brand)
⦁ Lavatory Faucet and Shower valves – Shall be top quality faucets and shower fittings
by American standard.
⦁For Water Heaters
Use STEIBEL ELTRON 1111-220881 (240479) MDL DHCE6 Instant Water Heater 6 KW,
electronic

Permit and fees – All permits, fees, processing of MAYNILAD connection and other
insurances shall be the
responsibility of the contractor.

Any discrepancies or clarification that needs final resolution shall be brought to the
attention of the Architect and Master Plumber.

All devices and layout shown on the plan shall be installed. The Owner will not
entertain extra work orders, so it shall be the duty of the contractor to clarify with the
architect or the Master Plumber the items of work prior to acceptance of the work
order.

Prepared by:

Ar. Krisna Liz B. Tantano, ENP 9 3/1/2021

You might also like