Flomid FX Electromagnetic Flowmeter
Flomid FX Electromagnetic Flowmeter
Electromagnetic Flowmeter
Introduction
Modular design in two versions:
• Compact, sensor and electronics unit forming a single unit
• Separate, sensor and electronics separated, joined by a cable
Various possibilities of pipe fittings:
• Flange: DIN, ANSI, JIS norms etc.
• Sandwich: for DIN, ANSI, JIS norm flanges etc.
• Sanitary: DIN 11851 thread, ISO 2852 Clamp, SMS 1145 thread
• Sanitary welding: DIN 11850, ISO 2037 norms
Sensor liners PP, PTFE, PVDF & hard rubber
Electrodes in AISI-316L, Hastelloy C22 (UNS-06022),
Zirconium, Titanium
Exterior construction in AISI-316L
Benefits
● Flow rate measurament is independent of the flow profile
● Square wave ac magnetic field to avoid electrolysis
● Readings are independent of density, temperature,
viscosity and pressure
● Absence of obstructing elements gives zero pressure loss
and will allow the pass of solids
● Can be mounted in any position, provided that the pipe
is always full
● Low power consumption
● Good stability with temperature and age
● No moving parts provides zero maintenance
● Can be installed with short straight pipe sections
(5DN / 3DN)
● Good chemical resistance of construction materials
● All electronic control units for use with all sensors
Tm = B x Vm x D
For the mechanical installation the most important factor to Mixtures of different liquids. The sensor should be installed
be taken into consideration is that the pipe must always be a minimum of 30DN from the point of mixture to avoid
full and the electrodes in contact with the liquid. To guarantee unstabilities in the readings.
this, the metering body should be mounted with the
electrodes in a horizontal plane and in a position so that the
pipe will always be full, without air pockets.
2
Straight sections of pipe are necessary for the correct For abrasive liquids or liquids with particles in suspension, it
working of the flowmeter. Curves, pipe reductions, control is recommended to mount the flowmeter in a rising pipe. For
elements and pumps should be at least 5 DN upstream and a horizontal pipe the installation can be made as in the
3 DN downstream from the flowmeter. following drawing with a valve system for cleaning.
3
Flow rate table Metering body selection
The diagram shows the relation
between the liquid speed and the
flow rate for different body sizes.
The metering body diameter
should be chosen to obtain a
maximum normal working liquid
velocity of about 3-4 m/s. The
minimum working liquid velocity
should not be below 0.5 m/s.
4
FLOMID 0 FX
Compact electronics
Separate electronics
5
DIN, ANSI Flanges FLOMID 2 FX / FLOMID 4 FX
MX Compact electronics
208 162
94 110 130
A
º
lxn
D
g
k
DN L3 + 0,5%
min + 1mm
MCX Compact electronics
46 122 120
80
B
º
lxn
h
D
g
k
c
DN L3 + 0,5%
min + 1mm
FX Sensor (Separate electronics)
1-10 16 3/8” 150 285 (11,2) 235 (9,3) 150 (5,90) 90 60 40 14x4 205 (8,1) 88,9 4,5 (9,92)
15 16 1/2” 150 285 (11,2) 235 (9,3) 150 (5,90) 95 65 45 14x4 205 (8,1) 88,9 60,3 34,9 16x4 4,8 (10,60)
20 16 3/4” 150 285 (11,2) 235 (9,3) 150 (5,90) 105 75 58 14x4 205 (8,1) 98,4 69,8 42,9 16x4 6 (13,22)
25 16 1” 150 285 (11,2) 235 (9,3) 150 (5,90) 115 85 68 14x4 205 (8,1) 107,9 79,4 50,8 16x4 7,5 (16,53)
32 16 1 1/4” 150 330 (13,0) 280 (11,1) 150 (5,90) 140 100 78 18x4 250 (9,9) 117,5 88,9 63,5 16x4 8 (17,63)
40 16 1 1/2” 150 330 (13,0) 280 (11,1) 150 (5,90) 150 110 88 18x4 250 (9,9) 127,5 98,4 73 16x4 8,5 (18,74)
50 16 2” 150 347 (13,6) 297 (11,7) 200 (7,87) 165 125 102 18x4 267 (10,5) 152,4 120,6 92,1 19x4 10 (22,05)
65 16 2 1/2” 150 367 (14,5) 317 (12,5) 200 (7,87) 185 145 122 18x4 287 (11,3) 177,8 139,7 104,8 19x4 11 (24,25)
80 16 3” 150 367 (14,5) 317 (12,5) 200 (7,87) 200 160 138 18x4 287 (11,3) 190,5 152,4 127 19x4 12,5 (27,55)
100 16 4” 150 418 (16,4) 368 (14,5) 250 (9,84) 220 180 158 18x4 338 (13,3) 228,6 190,5 157,2 19x8 15 (33,06)
125 16 5” 150 443 (17,4) 393 (15,5) 250 (9,84) 250 210 188 18x4 363 (14,3) 254 215,9 185,7 23x8 18,5 (40,78)
150 16 6” 150 473 (18,6) 423 (16,7) 300 (11,81) 285 240 212 22x8 393 (15,5) 279,4 241,3 215,9 23x8 20,6 (45,41)
200 10 8” 150 523 (20,6) 473 (18,6) 350 (13,77) 340 295 268 22x8 443 (17,5) 342,9 298,4 269,9 23x8 32 (70,54)
250 10 10” 150 575 (22,6) 525 (20,7) 400 (15,74) 395 350 320 22x8 495 (19,5) 406,4 361,9 323,8 25x12 45 (99,20)
300 10 12” 150 621 (24,5) 571 (22,5) 500 (19,68) 445 400 370 22x8 541 (21,3) 482,6 431,8 381 25x12 52 (114,63)
350 10 14” 150 671 (26,4) 621 (24,5) 500 (19,69) 505 460 430 22x8 591 (23,3) 533,4 476,2 412,7 30x12 62 (136,68)
400 10 16” 150 721 (28,4) 671 (26,4) 600 (23,62) 565 515 482 26x16 641 (25,3) 596,9 539,7 469,9 30x16 76 (167,54)
500 10 18” 150 825 (32,5) 775 (30,5) 600 (23,62) 670 620 585 26x20 745 (29,4) 635 577,8 533,4 33x16 98 (216,04)
6
DIN 11851 FLOMID 1 FX DIN 11851 FLOMID 1 FX
MX Compact electronics
DN 10 15 20 25 32 40 50 65 80 100
NW Ø d1 10 16 20 26 32 38 50 66 81 100
Rd 28 Rd 34 Rd 34 Rd 52 Rd 58 Rd 65 Rd 78 Rd 95 Rd 110 Rd 130
Ø d5 x 1/8” x 1/8” x 1/6” x 1/6” x 1/6” x 1/6” x 1/6” x 1/6” x 1/4” x 1/4”
H 28 28 28 29 29 29 29 31 27 28
Ø d3 60 64 70 80 90 100 114 144 160 180
A 268 272 275 280 286 290 300 310 318 328
L1 200 220 240 280 330
L2 192 188 206 226 264 310
L3 120 134 154 186 234
F 45 48 54 - - - - - - -
FLOMID 1...3 FX
MXC Compact electronics
7
CLAMP ISO 2852:1993 FLOMID 6 FX CLAMP ISO 2852 : 1993 FLOMID 6 FX
MX Compact electronics Coupling
dimensions - - 1/2” - - 1” 1 1/4” 1 1/2” 2” 2 1/2” 3” 4”
Equival. DIN-DN 6 6 10 15 20 25 32 40 50 65 80 100
pipe
outside ø 8 12 12,7 17,2 21,3 25 33,7 38 51 63,5 76,1 101,6
Ø C6 6 10 10,7 15,2 19,3 22,6 31,3 35,6 48,6 60,3 72,9 97,6
Ø C7 34 34 34 34 34 50,5 50,5 50,5 64 77,5 91 119
H 30 30 30 30 30 31 31 31 31 34 34 34
Ø d3 60 60 60 64 70 80 90 100 114 144 160 180
A 268 268 268 272 275 280 286 290 300 310 318 328
L3 120 134 154 186 234
L1 200 220 240 280 330
F 45 45 45 48 54 - - - - - - -
8
Liner materials. Temperature, Pressure and Vacuum (20oC reference temperature)
PTFE PTFE / PVDF PP EBONITA
DIN2501(3) ANSI mbar psi DIN2501 ANSI mbar psi DIN2501 ANSI mbar psi DIN2501 ANSI mbar psi
B 16.5(4) B 16.5 B 16.5 B 16.5
3 0 0
6 60 0,9 100 1,5
∆ ∆ ∆ ∆ ∆ ∆
10 16 40 150 300 16 150 300 16 150 300
∆
∆
∆
∆
∆
∆
∆
∆ ∆ ∆ ∆
40
50 500 7,5 600 9 700 10,5 200 3
65 150 2,2 150 2,2 200 3 120 1,8
∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆
16 40 150 300 16 150 300 16 150 300 16 40 150 300
∆
∆
∆
∆
∆
125 16 150 750 11,2 10 150 300 800 12 10 150 300 900 13,5 10 150 ∆ ∆
∆
900 13,5 ∆ ∆
(1) In mbar absolute 40oC and 80oC reference temperature (3) bar
(2) Maximum 30’. On order up to 180oC and PN200 (4) lbs
Wiring
250 mA (T)
9
Electronic Control Units Cycle
Different models of electronic control units are available mv
*M = wall mounting
*T = pipe mounting Note: There is no difference between the compact and the
separated electronics except for the M or T accesory
(supplied for its mounting on a wall or on a pipe), and for the
cable for its connection to the sensor.
● Plastic coated (Polyamide 11) injected aluminium housing. ● Adaptive flowrate filter: Integration time programmable
IP 67 degree of protection 0.1 ... 25.5 seconds
● Programming via front tactile pushbuttons Filter reset window programmable
● Totalising and partial volume counters ● Linearity: 0.1%
● Programmable batching volume with remote input ● Zero drift: 0.05%
for starting ● Temperature drift: 0.015% / oC
● Magnetic field: 6.25 Hz square wave for ● Working ambient temperature range: -10 ...+60 oC
50 Hz mains
7.5 Hz square wave
for 60 Hz mains
● Mains supply: 12 V, 24 V, 110 V, 120 V, 220 V,
240 V ac, + 10%, 50 o 60 Hz
24 Vdc
(others on demand)
● Power consumption: <10 VA
● Min. Flowrate cut off: Programmable
● Measuring range: 0...10 m/s
● Display: 16 character x 2 lines LCD
6 languages to be selected.
Program for auto-edition of
other languages
● Flowrate indication: User programmable
measuring units
● Analog output: 4...20 mA programmable
● Programmable pulse output mode:
Flowrate x Pulses/unit volume < 2 pulses/s
● Programmable frequency output mode: 10..1000 Hz
● Logic outputs: Two programmable outputs for
flowrate alarms, empty pipe
detection, flow direction or batching
10
The MCX Series are a reliable and economical solution for a FLOMID MCX/T, MCX/FT & MCX/FI
majority of industrial processes that require specific controls
such as:
11
MCX/T-M...T, MCX/FT-M...T, MCX/FI-M...T Flomid MCX/T, MCX/FT, MCX/FI
(Separate electronics) (Compact electronics)