004 VDL200, Functions Description and Parameters List

The document provides information about the functions and parameters of a vector inverter for lifts with asynchronous motors. It describes the drive's functions, parameters, and configuration options across several sections. Safety instructions and technical support contact information are also included.

Uploaded by

mohammad ghassan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
897 views

004 VDL200, Functions Description and Parameters List

The document provides information about the functions and parameters of a vector inverter for lifts with asynchronous motors. It describes the drive's functions, parameters, and configuration options across several sections. Safety instructions and technical support contact information are also included.

Uploaded by

mohammad ghassan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 112

Vector inverter for lifts with

SIEIDrive
asynchronous motors

VDL200
.... Functions description
and parameters list
Information about this manual

This manual explains the functions and the description of the parameters.
The informations about mechanical installation, electrical connection and fast start-up can be found on the VDL200 Quick
start guide.
The whole set of manuals can be found on the CD provided with the dirve.

Software version
This manual is updated according the software version V 1.X.0
Variation of the number replacing “X” have no influence on the functionality of thedevice.
The identification number of the software version is indicated on the identification plate of the drive or can be checked with
the PAR 490 Firmware ver.rel parameter, menu 2.7.

General information

Note ! In industry, the terms “Inverter”, “Regulator” and “Drive” are sometimes interchanged. In this document, the term “Drive” will be used.

Before using the product, read the safety instruction section carefully. Keep the manual in a safe place and available to
engineering and installation personnel during the product functioning period.
Gefran S.p.A has the right to modify products, data and dimensions without notice. The data can only be used for the prod-
uct description and they can not be understood as legally stated properties.

Thank you for choosing this Gefran product.


We will be glad to receive any possible information which could help us improvingthis manual.
The e-mail address is the following: [email protected].
All rights reserved.

2 VDL200 • Functions description and parameters list


Table of Contents

Information about this manual...................................................................................................................2


Symbols used in the manual...................................................................................................................................4
A - Programming.........................................................................................................................................5
A.1 Menu display modes.........................................................................................................................................5
A.2 Programming of “function block” analog and digital input signals.....................................................................5
A.3 Variable interconnections mode........................................................................................................................5
B - Parameters and functions description (Expert list)...........................................................................7
Legend.....................................................................................................................................................................7
1 - MONITOR .........................................................................................................................................................8
2 - DRIVE INFO ....................................................................................................................................................10
3 - STARTUP WIZARD ........................................................................................................................................12
4 - DRIVE CONFIG ..............................................................................................................................................13
5 - LIFT..................................................................................................................................................................16
5.1 – SPEED.........................................................................................................................................................................16
5.2 – RAMPS.........................................................................................................................................................................18
5.3 – LIFT SEQUENCES.......................................................................................................................................................20
5.4 – MECHANICAL DATA ...................................................................................................................................................24
5.5 – DISTANCE....................................................................................................................................................................26
5.6 – EMERGENCY MODE ..................................................................................................................................................32
5.7 – INPUT/OUTPUT...........................................................................................................................................................34
5.8 –PRE - TORQUE ............................................................................................................................................................44
5.9 – LIFT ALARMS...............................................................................................................................................................46
6 - ..........................................................................................................................................................................49
7 -...........................................................................................................................................................................49
8 - ........................................................................................................................................................................49
9 -...........................................................................................................................................................................49
10 - DIGITAL INPUTS .........................................................................................................................................50
11 - DIGITAL OUTPUTS ......................................................................................................................................51
12 - ANALOG INPUTS...........................................................................................................................................52
13 - ........................................................................................................................................................................55
14 - MOTOR DATA ...............................................................................................................................................56
15 - ENCODER CONFIG.......................................................................................................................................59
16 - SPEED REG GAINS .....................................................................................................................................61
17 - REGULATOR PARAM .................................................................................................................................65
18 - TORQUE CONFIG ......................................................................................................................................67
19 - VF PARAMETERS .......................................................................................................................................69
20 - FUNCTIONS .................................................................................................................................................72
20.1 - FUNCTIONS/INERTIA COMP.....................................................................................................................................72
20.2 - FUNCTIONS/DC BRAKING .......................................................................................................................................72
20.3 - FUNCTIONS/MOTOR OVERLOAD ..........................................................................................................................74
20.4 - FUNCTIONS/BRES OVERLOAD .............................................................................................................................76
20.5 - FUNCTIONS/DOUBLE PAR SET...............................................................................................................................77
20.6 - FUNCTIONS/SPEED CAPTURE ..............................................................................................................................78
20.7 - FUNCTIONS/COMPARE ...........................................................................................................................................78
20.8 - FUNCTIONS/PADS ....................................................................................................................................................79
21 - COMMUNICATION .......................................................................................................................................81
21.1 - COMMUNICATION/RS232.........................................................................................................................................81
21.2 - ..................................................................................................................................................................................81
21.3 - ...................................................................................................................................................................................81
21.4 - .................................................................................................................................................................................81
21.5 - ..................................................................................................................................................................................81
21.6 - ..................................................................................................................................................................................81
22 - ALARM CONFIG............................................................................................................................................82
23 - ALARM LOG .................................................................................................................................................90
PARAMETERS ON SELECTION LISTS, BUT NOT DISPLAYED ON KEYPAD..................................................91
C - SELECTION LISTS...............................................................................................................................95
L_CMP .................................................................................................................................................................95
L_DIGSEL1 .........................................................................................................................................................95
L_DIGSEL2 .........................................................................................................................................................95
L_DIGSEL3 .........................................................................................................................................................95
L_LIM ...................................................................................................................................................................95
L_SCOPE ............................................................................................................................................................96
L_WDECOMP ......................................................................................................................................................96
D - Block Diagrams...................................................................................................................................97
System diagram index...........................................................................................................................................97
Drive overview (DrvOverview)...............................................................................................................................97
ADL1 application index (ADL1FuncIndex).............................................................................................................98

VDL200 • Functions description and parameters list 3


Expansion card digital inputs (DigImpExp)..........................................................................................................101
Expansion card digital outputs (DigOutExp)........................................................................................................101
Analog inputs.......................................................................................................................................................102
Encoder config.....................................................................................................................................................102
SLS control (ControlVf)........................................................................................................................................103
Functions.............................................................................................................................................................104
Torque control (TorqueCtrl)..................................................................................................................................107
Gains adaptive (GainAdapt)................................................................................................................................108

Symbols used in the manual

Indicates a procedure, condition, or statement that, if not strictly observed, could result in personal injury or death.
Indique le mode d’utilisation, la procédure et la condition d’exploitation. Si ces consignes ne sont passtrictement respec-
Warning
tées, il y a des risques de blessures corporelles ou de mort.

Indicates a procedure, condition, or statement that, if not strictly observed, could result in damage to or destruction of
equipment.
Caution Indique et le mode d’utilisation, la procédure et la condition d’exploitation. Si ces consignes ne sont pas strictement res-
pectées, il y a des risques de détérioration ou de destruction des appareils.

Indicates that the presence of electrostatic discharge could damage the appliance. When handling the boards, always
wear a grounded bracelet.
Indique que la présence de décharges électrostatiques est susceptible d’endommager l’appareil. Toujours porter un brace-
let de mise à la terre lors de la manipulation des cartes.

Indicates a procedure, condition, or statement that should be strictly followed in order to optimize these applications.
Indique le mode d’utilisation, la procédure et la condition d’exploitation. Ces consignes doivent êtrerigoureusement respec-
Attention
tées pour optimiser ces applications.

Note ! Indicates an essential or important procedure, condition, or statement.


Indique un mode d’utilisation, de procédure et de condition d’exploitation essentiels ou importants.

4 VDL200 • Functions description and parameters list


A - Programming

A.1 Menu display modes


The programming menu can be displayed in two modes, which can be selected using the Access mode parameter (04 -
DRIVE CONFIG menu):
• Easy (default) only the main parameters are displayed.
• Expert all the parameters are displayed.

A.2 Programming of “function block” analog and digital input signals
The signals, variables and parameters of each single “function block” of the drive are interconnected in order to achieve
the configurations and controls inside the control system.
These can be managed and modified using the keypad, PC configurator or fieldbus programming.
The programming mode is based on the following logic:

Src (source; i.e.: Ramp ref 1 src, PAR: 610)


This term defines the source of the function block input, i.e. the signal to be processed in the function
block.
The different configurations are defined in the relative selection lists.

Mon (display; i.e.: Ramp ref 1 mon, PAR: 620)


This term refers to the variable output from the function block, which is the result of the calculations
performed on the actual block.

Function block

Parameter

Input selected Variable


src Monitor
Parameter

A.3 Variable interconnections mode


The source (src) allows the desired control signal to be assigned to the function block input.
This operation is performed by using specific selection lists.

Possible control signal sources:


1 – Physical terminal
The analog and digital signals come from the terminal strip of the regulation card and/or from those of the expansion cards.

2 – Drive internal variables


Internal drive control system variables, from “function block” calculations, sent via keypad, PC configurator or fieldbus.

Practical example
The following examples illustrate the philosophies and methods with which more or less complex operations are performed
in the single “function blocks”, the results of which represent the output of the block.

• Example: Changing the Speed Reference source


The main drive reference (in the default configuration) Ramp ref 1 mon (PAR: 620) is generated by the output of the func-
tion block “Ramp setpoint Block”.
Its default source is the Analog input 1 mon signal, from the output of the function block “Analog input 1 Block”, which in

VDL200 • Functions description and parameters list 5


this case refers to analog input 1 of the signal terminal strip.
To change the reference source from the analog input to a digital reference inside the drive, the input signal must be
changed to “Ramp setpoint Block”.
Enter the Ramp ref 1 src parameter (PAR: 610) and set a new reference, selecting it from among those listed in the L_ML-
TREF selection list, for example Dig ramp ref 1 (PAR: 600).

• Example: Inverting the analog reference signal


To invert the “Analog input 1X Block” output signal, the value of the An inp 1X sign src parameter (PAR: 1626), which
has a default setting of Null (no operation), must be changed by selecting the source of the command signal from among
those listed in the L_DIGSEL 2 selection list, for example Digital input X mon, One (function always enabled), etc.

* -1
Terminal input Analog input 1X Block Analog input 1X mon
* +1

Null An inp 1X sign src

+1
Ramp ref 1 src Ramp Setpoint Block Ramp ref 1 mon
-1

Null Ramp ref invert src

The diagrams above illustrate the internal processing philosophy of the single “function blocks” and the result of these
changes on the other interconnected “function blocks”.

Note ! This section contains a brief description of the functions of the other parameters in the function blocks not included for the changes in the
example.

The Ramp ref invert src parameter (PAR: 616) can be used to select the source for the command to reverse the “Ramp
setpoint” function block output.
The output signal from the “Ramp setpoint” block is displayed in the Ramp ref 1 mon parameter (PAR: 620).

6 VDL200 • Functions description and parameters list


B - Parameters and functions description (Expert list)

Legend

          
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1 - MONITOR ( Level 1 menu)


1.1 250 Output current A
FLOAT
16/32 0.0 0.0 0.0 R
FVS
1.2 252 Output voltage V FLOAT 16/32 0.0 0.0 0.0 R FVS

5.2 – RAMPS ( Level 2 menu )

11 - DIGITAL OUTPUTS
11.01 1410 Dig output 1X src LINK 16BIT 1062 0 16384 ERW FVS
L_DIGSEL1 ( Selection List ) [*]

Accessibility :
 Indexing of the menu and parameter

E Expert
 Parameter identifier
 R Read
 Parameter description S
W
Size (set value depending on the size of the device)
Write (scrittura)
 UM: unit of measure Z parameters that can be modified ONLY with the drive disabled

Available in regulation mode:


Type of parameter
 V = V/f Control (open loop)
BIT Boolean, from modbus seen as 16 bits S = Vect Flux OL
ENUM Selection list, from modbus seen as 16 bits F = Vect Flux CL (closed loop)
FLOAT Real, from modbus seen as 32 bits
 INT16 Integer with sign 16 bits, from modbus seen as 16 bits
Selection lists:
INT32 Integer with sign 32 bits, from modbus seen as 32 bits
ILINK Selection list, from modbus seen as 16 bits The “Sorgente.../Sorg...” format parameters are linked to a
LINK Selection list, from modbus seen as 16 bits selection list.
UINT16 Integer without sign 16 bits, from modbus seen as 16 bits [*]
The source of the signal that will control the parameter can be
UINT32 Integer without sign 32 bits, from modbus seen as 32 bits selected from the list indicated.
The lists are indicated in paragraph C of this manual.

 Format of data exchanged on Fieldbus (16BIT, 32BIT)

 Default value
CALCF Value calculated as a number with
floating point
 Minimum value
CALCI Value calculated as a whole number
SIZE Value depending on the size of the drive
 Maximum value

VDL200 • Functions description and parameters list 7


1 - MONITOR
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.1 250 Output current A


FLOAT
16/32BIT 0.0 0.0 0.0 R
FVS
The drive output current is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.2 252 Output voltage V FLOAT


16/32BIT 0.0 0.0 0.0 R FVS
The drive line voltage output is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.3 254 Output frequency Hz


FLOAT
16/32BIT 0.0 0.0 0.0 R
FVS
The drive output frequency is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.4 628 Ramp setpoint rpm


INT16
16/32BIT 0 0 0 R
FVS
The ramp reference is displayed. This is the speed value the drive must reach at the end of the ramp.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.5 664 Speed setpoint rpm


INT16
16/32BIT 0 0 0 R
FVS
The speed reference is displayed. This is the value measured at the output of the speed reference circuit.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.6 260 Motor speed rpm


INT16
16/32BIT 0 0 0 R
FVS
The actual output speed of the motor is displayed (in FOC = speed measured by the encoder, in SLS/VF = speed esti-
mated by the drive).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.7 270 DC link voltage V


FLOAT
16/32BIT 0.0 0.0 0.0 ER
FVS
The direct voltage of the intermediate circuit capacitors is displayed (DC-Bus).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.8 272 Heatsink temperature °C


INT16
16BIT 0 0 0 ER
F_S
The temperature measured on the drive heatsink is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.9 280 Torque current ref A


FLOAT
16/32BIT 0.0 0.0 0.0 ER
F_S
The current reference used for torque control is displayed (in the sensorless vector and field-oriented vector modes).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.10 282 Magnet current ref A


FLOAT
16/32BIT 0.0 0.0 0.0 ER
FVS
The magnetizing current reference is displayed (in the sensorless vector and field-oriented vector modes).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.11 284 Torque current A


FLOAT
16/32BIT 0.0 0.0 0.0 ER
FVS
The actual torque current value is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.12 286 Magnet current A


FLOAT
16/32BIT 0.0 0.0 0.0 ER
FVS
The actual magnetizing current value is displayed.

8 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.13 3212 Motor overload accum


UINT16
16/32BIT 0 0 100 ER
FVS
The motor overload level is displayed (100% = alarm threshold).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.14 368 Drive overload accum


UINT16
16/32BIT 0 0 100 ER
FVS
The drive overload level is displayed. An instantaneous overload of 200% of the drive rated current is allowed for 10s. The
thermal image I²t adjusts the drive output current thresholds. During normal operation, the instantaneous output current
value can reach 200% of the drive rated current. When the overload level par. 368 Drive overload accum reaches 100%,
the output current threshold is reduced to 100% of the rated current, and stays at that value until the I²t integrator cycle is
complete. At this point the instantaneous overload of 200% or 150% (below 3Hz) will be re-activated.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.15 3260 Bres overload accum


UINT16
16/32BIT 0 0 100 ER
FVS
The braking resistor overload limit is displayed (100% = alarm threshold).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.16 1066 Enable state mon


BIT
16BIT 0 0 1 R
FVS
The drive Enable command status is displayed. Voltage must be present on terminal 7. The FR Forwardstart command is
needed to start the inverter.

1 Enabled drive enabled


0 Disabled drive disabled

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.17 1068 Start state mon


BIT
16BIT 0 0 1 R
FVS
The drive Start command status is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.18 1070 FastStop state mon


BIT
16BIT 0 0 1 R
FVS
The drive FastStop command status is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.19 1200 Digital input X mon


UINT16
16BIT 0 0 0 R
FVS
The status of the digital inputs of the expansion card is displayed. It can also be read via a serial line or fieldbus. The data
are contained in a word, where each bit is 1 if voltage is supplied to the corresponding input terminal.

1 Input enabled.
0 Input disabled.

Example:
0 0 0 0 0 0 0 0 0 0 1 1
Enable
DI 1

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

1.20 1400 Digital output X mon


UINT16 0 0 0 R
FVS
The status of the digital outputs of the expansion card is displayed. It can also be read via a serial line or fieldbus. The data
are contained in a word, where each bit is 1 if voltage is supplied to the corresponding input terminal.

1 Output enabled.
0 Output disabled.

Example:
0 0 0 0 0 0 0 0 0 0 1 1
DO 1
DO 2

VDL200 • Functions description and parameters list 9


2 - DRIVE INFO
This menu displays the information for identifying and configuring the drive.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.1 482 Drive size UINT16 0 0 0 RS FVS


The drive size identification code is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.2 484 Drive family ENUM No Power 0 0 RS FVS


The available mains voltage is displayed (e.g. 400V). The undervoltage alarm refers to this voltage value.
The condition No power occurs when the regulation board has just left from production and has never been configured for
any power. The configuration adjustment for a given power is achieved by linking it to a power board and running a Save
parameters.
0 No Power
1 230V..480V
2 500V..575V
3 690V
4 230V

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.3 488 Drive cont current A FLOAT CALCF 0.0 0.0 RZS FVS
The current that the drive can deliver continuously according to size, supply voltage and programmed switching frequency
is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.4 490 Firmware ver.rel UINT16 0 0 0 R FVS


The version number and release number of the drive firmware are displayed. On the keypad these are displayed in the ver-
sion.release format. The parameter reading from the serial communication device or fieldbus returns the version in the high
byte and the release in the low byte.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.5 496 Firmware type UINT16 0 0 0 R FVS


Identifies the version of the special firmware installed in the drive

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.6 504 Application ver.rel UINT16 0 0 0 ER FVS


The version and release number of the application used in the drive are displayed. On the keypad these are displayed in
version.release format. When the parameter is read via serial line or fieldbus the version is returned in the high byte and
the release in the low byte.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.7 510 Time drive power on h.min UINT32 0 0.0 0.0 ER FVS
The total time for which the drive has been powered is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.8 512 Time drive enable h.min UINT32 0 0.0 0.0 ER FVS
The time for which the enable hardware contact on the drive has been connected is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.9 514 Number power up UINT16 0 0 0 ER FVS


The number of times the drive has been powered on is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.10 516 Time fan on h.min UINT32 0 0.0 0.0 ER FVS

10 VDL200 • Functions description and parameters list


The total time for which the drive fan has been running is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.11 520 Product S/N UINT32 0 0 0 R FVS


The drive serial number is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.12 522 Regulation S/N UINT32 0 0 0 R FVS


The drive regulation card serial number is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.13 524 Power S/N UINT32 0 0 0 R FVS


The drive power card serial number is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

2.14 526 Power file ver.rel UINT16 0 0 0 ER FVS


The drive power card configuration release is displayed.

VDL200 • Functions description and parameters list 11


3 - STARTUP WIZARD
The startup wizard menu suggests a procedure for commissioning the drive quickly with a reduced number of settings. Advanced
customization requires the use of the single parameters relating to the specific performance levels. Refer to the procedure de-
scribed in chapter 9 Commissioning via keypad in the Quick start-up guide.

12 VDL200 • Functions description and parameters list


4 - DRIVE CONFIG
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.1 550 Save parameters BIT 0 0 1 RW FVS


Any changes to parameter values immediately affect drive operations, but are not automatically saved in the permanent memory.
The “Save Parameters” command is used to save current parameter values in the permanent memory.
Any changes that are not saved will be lost when the drive is switched off.
To save parameters follow the procedure described in STEP 9 of the Startup wizard.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.2 552 Regulation mode ENUM SSC 0 3 RWZ FVS


The VDL200 is capable of operating with different control modes:
0 SSC (Sensorless Scalar Control)
1 Flux vector OL
2 Flux vector CL
3 Autotune
The open loop SSC mode is the simplest type of asynchronous motor control, as the only parameters required are the
rated voltage, current and frequency of the motor.
The open loop SSC control mode is factory-set and does not require any speed feedback. The natural variation in speed
generated by machine load induction (slippage) can be compensated using Slip comp and Slip comp filter.
In V/f mode a single drive can be used to control several asynchronous motors, even of different sizes, connected in
parallel, provided the sum of the currents of the single motors is less than the drive rated current. If using several motors
connected in parallel, be sure to provide adequate thermal protection for each single motor.
Closed loop control is also possible in the SSC mode. It requires a speed reading by a digital encoder on the motor shaft;
to enable encoder feedback, you must set parameter 2444 Slip comp mode =1.
An optional card is necessary in order to acquire the encoder signals. The speed feedback supplied by the encoder is used
to compensate motor slippage in the different load conditions, to achieve accurate control and greater precision of the
actual motor speed.

With the sensorless vector control (Flux vector OL) mode, high speed and torque precision can be achieved at low mo-
tor rpm. The drive has a powerful algorithm that uses a self-tuning procedure to obtain all the electric measurements of the
motor. This allows the speed and position of the motor shaft to be estimated, enabling operation similar to that of a drive with
feedback, both in terms of the response in torque to load variations, and of the regularity of rotation even at very low rmp.

In the field oriented vector mode (Flux vector CL) an encoder is required for closed loop feedback. With this mode it is
possible to achieve extremely high dynamic responses thanks to the regulation bandwidth, maximum torque even with the
rotor blocked, speed and torque control. Numerous regulation parameters can be used to adjust the drive to each specific
application, for instance adaptive gains, system inertia compensation, etc..

Note! When the drive is set to Flux vector CL mode you must set PAR 2132 Encoder mode = “DIGITAL FP” or “DIGITAL F” (15 - ENCODER CONFIG
menu).

If the Startup wizard procedure is not used, self-tuning of the motor parameters is possible in the self-tuning mode (Autotune).
This procedure must be used for both self-tuning with the engine standing still and with the motor turning.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.3 554 Access mode ENUM Easy 0 1 RW FVS

0 Easy
1 Expert
The Easy mode gives access to a list of parameters that can be used for rapid drive commissioning. This type of configu-
ration is suitable for the majority of applications.

Setting the parameter to Expert gives access to all the parameters in the firmware. This mode allows an extremely high
level of customization to be achieved in order to exploit the potential of the VDL200 to the full.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.4 558 Application select ENUM Enable 0 2 ERWZ FVS


Selection of which IEC 61131-3-compliant application to make operational.
0 Disable
1 Enable

The drive is supplied already incorporating a number of applications developed in the IEC 61331-3 environment. To use
these, configure the desired application, run save parameter, switch the drive off and then on again. In the default configu-
ration the drive starts with the EFC lift application (see menu 5 - LIFT for the description of this application).

VDL200 • Functions description and parameters list 13


Note! The Load Default command (par. 580) does not modify this parameter

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.5 560 Mains voltage V ENUM 400 V SIZE SIZE ERWZS FVS
Setting of the available mains voltage value in Volts. Detection of the undervoltage alarm refers to this value.
0 200 V
1 230 V
2 380 V
3 400 V
4 415 V
5 440 V
6 460 V
7 480 V
8 575 V
9 690 V

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.6 448 Emergency UV V FLOAT CALCF 0.0 CALCF ERWZ FVS


This parameter enables for the undervoltage threshold to be configured during emergency conditions.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.7 570 Password UINT32 0 0 99999 ERW FVS


You can enter a password to protect the parameters from unauthorized tampering: the password can consist of a com-
bination of a maximum of any 5 figures that can be selected by the user. All parameters are locked, except this one and
Save parameters.
entering the password, press the E key, then enter the password and press the E key again to enable it (a password ena-
bled message (Enabled) is displayed).
So that the password remains valid even after switching the unit off and then switching it back on,
save it using the Save parameters command.

When the password is enabled any attempts to modify a parameter are blocked and the Password enabled message is
displayed.

To disable the password, enter the Password parameter (570) in the DRIVE CONFIG menu.
Check that the password is enabled (Enabled), press E and enter the combination of figures that make up the password.
Press E again. A message is displayed telling you the password is no longer enabled (Disabled).
To make sure the password continues to be disabled even after switching the unit off and then switching it back on, save
this configuration using the Save parameters command.
When an incorrect password is entered, the Password wrong message is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.8 572 Application key UINT32 0 0 4294967295 ERW FVS


This parameter can be used to enter the key for enabling the PLC application.
You may need to enter a key to definitively enable some PLC applications. Please contact Gefran for details about which
PLC applications require the key.
If executing an application that envisages a key verification and the key is incorrect, enabling is forced for 200 hours (time
drive enabled).
In this phase a message is displayed informing you that the period of forced enabling time is about to expire.
At the first power-on after the 200 hours an alarm is generated and the application does not start.
Please contact Gefran for the numerical value of the key.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.9 574 Startup display INT16 -1 -1 20000 ERW FVS


It is possible to set the parameter that will automatically be displayed when the drive is switched on.
If set to -1 the main menu is automatically displayed when the drive is turned on.
If set to 0 the display page is automatically displayed when the drive is turned on.

14 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.10 576 Display backlight BIT 0 0 1 ERW FVS


Enabling of the backlight on the drive display.
If set to 0 the display backlight will go off when the drive has been on for three minutes.
If set to 1 the backlight will stay on for as long as the drive is powered.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.11 578 Language select ENUM English 0 4 RWZ FVS


Setting of the drive programming language.
0 English
1 Italian
2 French
3 German
4 Spanish
8 Turkish

Note! The Load Default command (par. 580) does not modify this parameter.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.12 580 Load default BIT 0 0 1 RWZ FVS


Transfers the standard factory settings to the drive memory (“Def” column in the parameters table).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.13 590 Save par to keypad BIT 0 0 1 RW FVS


Transfers the parameters currently stored in the drive and saves them in the keypad memory (See VDL200 Quick Start
manual, chapter 8.3.13).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.14 592 Load par from keypad BIT 0 0 1 RWZ FVS


Transfers the parameters from the keypad memory to the drive (See VDL200 Quick Start manual, chapter 8.3.13).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

4.15 594 Keypad memory select UINT16 1 1 5 ERW FVS


Selection of the area of the keypad memory to which to transfer and save the parameters stored in the drive.

VDL200 • Functions description and parameters list 15


5 - LIFT
5.1 – SPEED

Multi speed selection


Through the combination of “MtlSpd S0” (Digital input 4), “MtlSpd S1” (Digital input 5) and “MtlSpd S2” (Digital input 6)
commands, is possible to select Multi speed desired, according to next table:
Attention
MtlSpd S2 MtlSpd S1 MtlSpd S0 ACTIVE SPEED
0 0 0 Multispeed 0, PAR 11020
0 0 1 Multispeed 1, PAR 11022
0 1 0 Multispeed 2, PAR 11024
0 1 1 Multispeed 3, PAR 11026
1 0 0 Multispeed 4, PAR 11028
1 0 1 Multispeed 5, PAR 11030
1 1 0 Multispeed 6, PAR 11032
1 1 1 Multispeed 7, PAR 11034

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.1 11002 Travel units sel Hz


ENUM 0 0 2 RW
FVS
Selection of the unit of measure for speed references.

0 Hz (output frequency)
1 m/s (cabin speed and depends on the mechanical constant)
2 Rpm (speed of the motor shaft)
3 USCS (US units: fpm, ft/s2, ft/s3)

When the unit of measure is modified the conversion constants are re-calculated, the units of measure are changed in the
parameter list and the multispeed values are converted into the new unit of measure (the result may contain approxima-
tions due to the conversion calculations).
A variable representing the speed of the cabin in m/s (fpm) is always available (PAR 12210).
There are fixed units of measure for the acceleration and deceleration parameters m/s² (ft/s2), and for jerks m/s³ (ft/s3).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.2 11020 Multi speed 0 Hz FLOAT 5.00 -10000 10000 RW FVS


Setting of the multispeed 0 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
This setting is taken as the default low speed value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.3 11022 Multi speed 1 Hz FLOAT 50.00 -10000 10000 RW FVS


Setting of the multispeed 1 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
This setting is taken as the default high speed value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.4 11024 Multi speed 2 Hz FLOAT 20.00 -10000 10000 RW FVS


Setting of the multispeed 2 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
This setting is taken as the default maintenance speed value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.5 11026 Multi speed 3 Hz FLOAT 0.00 -10000 10000 RW FVS


Setting of the multispeed 3 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.

16 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.6 11028 Multi speed 4 Hz FLOAT 0.00 -10000 10000 RW FVS


Setting of the multispeed 4 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.7 11030 Multi speed 5 Hz FLOAT 0.00 -10000 10000 RW FVS


Setting of the multispeed 5 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.8 11032 Multi speed 6 Hz FLOAT 0.00 -10000 10000 RW FVS


Setting of the multispeed 6 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.9 11034 Multi speed 7 Hz FLOAT 0.00 -10000 10000 RW FVS


Setting of the multispeed 7 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.10 12010 Actual multi spd sel


ENUM R
FVS
The currently selected speed is displayed.
0 Multi speed 0
1 Multi speed 1
2 Multi speed 2
3 Multi speed 3
4 Multi speed 4
5 Multi speed 5
6 Multi speed 6
7 Multi speed 7
8 Null

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.1.11 12210 Actual speed ref m/s


FLOAT R
FVS
The speed of the cabin is displayed in m/s.

VDL200 • Functions description and parameters list 17


5.2 – RAMPS
The lift application envisages an S-shaped ramp function with the possibility of setting 4 independent jerks and linear acceleration
and deceleration factors, as in the standard profile illustrated in the figure below.

Acc end jerk Dec ini jerk

Acceleration Deceleration

Dec end jerk


Acc ini jerk
Stop deceleration
Speed ref 1 Spd 0 ref thr
Slow Down dist

The Acc ini Jerk, Acceleration and Acc end jerk values used to execute the acceleration ramp are calculated by multiplying the cor-
responding parameters by the acceleration ramp factor (Percent acc factor), while the Dec ini jerk, Deceleration and Dec end jerk
values used to execute the deceleration ramp are calculated by multiplying the corresponding parameters by the deceleration ramp
factor (Percent dec factor, PAR 11056).

When the Start command is removed, the reference speed is zero regardless of the reference selected in the multispeeds. In this fi-
nal part of the profile the jerk deceleration values are used directly (not multiplied by Percent dec factor, PAR 11056) with the Stop
deceleration parameter as the linear deceleration. The factors for the final section of the profile are also used in case of a Stop lift
emergency condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.1 11040 Acc ini Jerk m/s³


FLOAT 0.50 0.01 20 RW
FVS
Setting of the jerk value for the first part of the acceleration.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.2 11042 Acceleration m/s²


FLOAT 0.60 0.01 10 RW
FVS
Setting of the maximum acceleration value.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.3 11044 Acc end jerk m/s³


FLOAT 1.40 0.01 20 RW
FVS
Setting of the jerk value for the last part of the acceleration.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.4 11046 Dec ini jerk m/s³


FLOAT 1.40 0.01 20 RW
FVS
Setting of the jerk value for the first part of the deceleration.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.5 11048 Deceleration m/s²


FLOAT 0.60 0.01 10 RW
FVS
Setting of the maximum deceleration value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.6 11050 Dec end jerk m/s³


FLOAT 0.50 0.01 20 RW
FVS
Setting of the jerk value for the last part of the deceleration.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.7 11052 Stop deceleration m/s²


FLOAT 0.70 0.01 10 RW
FVS
Setting of the maximum deceleration value used when the start command is removed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.8 11054 Percent acc factor Perc FLOAT 100.00 10 10000 RW FVS
Setting of the acceleration factor multiplier.
If set to 100 the ramp uses the factors entered in the parameters.

18 VDL200 • Functions description and parameters list


If set to a value of less than 100 the lift will tend to accelerate over a longer distance.
If set to a value of more than 100 the lift will tend to accelerate over a shorter distance.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.2.9 11056 Percent dec factor Perc FLOAT 100.00 10 10000 RW FVS
Setting of the deceleration factor multiplier.
If set to 100 the ramp uses the factors entered in the parameters.
If set to a value of less than 100 the lift will tend to decelerate over a longer distance.
If set to a value of more than 100 the lift will tend to decelerate over a shorter distance.

VDL200 • Functions description and parameters list 19


5.3 – LIFT SEQUENCES
This menu shows the parameters used to manage and define the travel of the lift depending on the status of the inputs and alarms.
The structure of the lift sequences is summarised below.

Enable
PLC TO DRIVE SIGNALS

Start fwd /
Start rev
Mlt spd s 0

Mlt spd s 1

Mlt spd s 2

Acc end jerk Dec ini jerk

Acceleration Deceleration

Dec end jerk


Acc ini jerk
End decel
Speed ref 1 Spd 0 ref thr
Slow Down dist Spd 0 ref delay

Brake open delay Cont open delay


Magn. current
Brake close dly

Cont close delay

RUN cont mon /


UP cont mon /
DOWN cont mon
DRIVE TO PLC SIGNALS

Lift Enable mon

BRAKE cont mon

Lift Start mon


(Only FOC/BRS)
Lift Landing mon
(Only V/F)
Lift DC brake mon
Start Fw / Rw

Start Fw / Rw
Start magnet.

Open contac.

Running
Close contac

Close brake
Open brake

Wait 0 ref

Starting sequence:
1 Reading of the enable hardware input and checking for alarms (enabling is aborted in case of an alarm)
2 Detection of the Enable and Start commands as set in the Sequence start mode parameter
3 When the Start forward/reverse command is received, a command is sent to close the contactors, depending on the
direction of travel
4 When the time set in Cont close delay has elapsed the internal Enable lift signal is activated
5 The system waits for the magnetisation signal from the drive (Drive ready)
6 At the end of magnetisation the open brake signal is activated

20 VDL200 • Functions description and parameters list


7 The system waits for the brake to be opened (Brake open delay)
8 When the delay before opening the brake has elapsed the Start lift command is sent and movement is enabled.

Sequence of movement:
1 The motor is started and moves slowly at the speed set in Smooth start speed for the time indicated in Smooth start
delay
2 At the end of Smooth start delay, movements are managed by the multispeeds and S-shaped ramp
3 When the set speed is exceeded, the Brake 2 mon output signal can be used to check that the brake has actually been
opened
4 The EFC function with space control can be used to change to a slower speed
5 When the Start forward/reverse signal is lowered the signal indicating arrival at the floor is enabled and the start lift
signal is disabled
6 The start command can be sent again until the drive reaches zero speed: the operating conditions are restored.

Stopping sequence:
1 When zero speed is reached the DC stop command is enabled (SSC control)
2 The application waits the time needed to reach zero speed and sends the command to close brakes 1 and 2
3 It waits the time necessary for the brakes to close (Brake close delay) and, if the current is to be reduced with a ramp, it
waits for the current limit to reach zero. The internal Enable lift, arrival zone and DC brake signals are then lowered.
4 The application waits the time set in Contactor open delay and checks that the current supplied is zero, before sending
a command to open the contactors.

It is essential to make sure that whenever a drive alarm condition is generated or the drive is disabled, the drive is stopped
and a command is sent to open the contactors.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.1 11060 Sequence start mode


ENUM 0 0 2 RW
FVS
Setting of the procedure to start the contactor command sequence.
0 Start forward/reverse
1 Enable
2 Multispeed != 0

If set to 0 the contactor sequences can be enabled without the Enable command (Enable is only required for motor opera-
tion). The Enable signal can be sent by an auxiliary contact of the output contactors.
If set to 1 the contactor sequences can only be enabled if the Enable command is active.
If set to 2 the contactor sequences can be enabled using the multispeed values. Multispeed values other than 0 cause the
sequence to start. The start command must also be enabled.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.2 11062 Cont close delay ms INT32 200.00 0 10000 RW FVS


Setting of the delay time for closing the contactor.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.3 11064 Brake open delay ms


INT32 0 0 10000 RW
FVS
Setting of the brake opening delay time.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.4 11066 Smooth start delay ms


INT32 0 0 10000 RW
FVS
Setting of the time for which the Smooth start speed speed is enabled. If this parameter is set to zero, the S-shaped
profile is executed directly at the start, and the soft start function is excluded.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.5 11068 Brake close delay ms INT32 200.00 0 10000 RW FVS


Setting of the brake closing delay time.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.6 11070 Current down delay ms


INT32 0 0 10000 RW
FVS

VDL200 • Functions description and parameters list 21


Setting of the time necessary to lower the torque from the limit value enabled during travel to 0. It defines the inclination of
the down ramp in the “Current down ramp” function. The purpose of this function is to prevent the immediate removal of
motor torque when the brake is closed, which would cause mechanical strain in the cabin.
To avoid this phenomenon when the brake is closed the current limits are brought to the current value in use and then
lowered on the ramp.
To enable the function the Current down delay parameter must be set to a value other than zero.
This is only possible when Torque curr lim sel has a value other than “OFF”, otherwise Current down delay is forced to
zero.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.7 11072 Contactor open delay ms INT32 200.00 0 10000 RW FVS


Setting of the contactor opening delay time.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.8 11078 Speed 0 threshold rpm


INT16 30.00 RW
FVS
Setting of the zero speed threshold, below which the zero speed signal is activated.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.9 11080 Speed 0 delay ms UINT16 400.00 0 10000 RW FVS


Setting of the zero speed delay. After the zero speed signal and after the time set in this parameter the zero speed signal is
activated. These parameters are used to know the cabin stop.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.10 11082 Smooth start speed Hz


FLOAT 0.00 0.00 10000.0 RW
FVS
Setting of the speed in the smooth start phase.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.11 11084 Smooth start mode


ENUM 2 1 2 RW
FVS
Setting of the soft start mode.
1 Speed consant
2 Jerk variable

If set to 1 the soft speed is automatically selected after the start command regardless of the selected multispeed. The
duration of the smooth speed depends on the Smooth start delay parameter: if this parameter is set to zero the selected
multispeed is used and not the soft speed. This setting is used in systems with a reducer, as it helps to overcome initial
friction before starting with the profile.
If set to 2 an even slower starting mode is set, which uses the start jerk of the variable acceleration in the smooth start
phase. Depending on the values set in Smooth start speed and Smooth start delay the jerk value is calculated at the
end of the soft start phase with a linear ramp that changes this jerk from 0 to the calculated value.
The use of a variable value jerk obtains a variable start acceleration that follows a parabolic trajectory, enabling extremely
reduced variations in initial speed. This setting is mainly used in systems with gearless motors.

Lift start mon


1

0
Speed ref

Time

Smooth start spd Smooth start dly

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.12 11086 Door open speed m/s


FLOAT 0.00 RW
FVS

22 VDL200 • Functions description and parameters list


Setting of the door opening speed.
Source to enable brake release through the digital input. In standard sequence brake release is controlled
by the drive and therefore this parameter is set to ONE. In case that brake release should be conditioned
by some external control (e.g. PLC), set this parameter to digital input controlled by PLC.
Internal sequence for brake release will wait until this input is asserted.
During run brake will be closed whenever this input becomes not asserted.

Door open src


Function enable signal
Speed
Door open speed

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.13 12014 Trip number


INT32 0 R
FVS
The lift journey counter is displayed. The counter increases each time the Start lift signal is activated.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.3.14 12016 Sequence state


UINT16 0 R
FVS
The lift sequence status is displayed. (see graph)

VDL200 • Functions description and parameters list 23


5.4 – MECHANICAL DATA
The parameters described in this menu are used to define the mechanical and physical features of the system.

Mechanical constants
The mechanical constant defines the ratio between motor rpm and distance travelled by the cabin.
The ConstMech can be calculated in two ways, depending on which conversion method is used.

- Directly: Mechanical constant = System speed/(Full scale speed/60)


- Mechanical data: Mechanical constant = (π *Pulley diameter)/Reduction gear ratio

Pulley diameter

Gearbox ratio Rope weight

Motor Gearbox
Pulley
Car weight

Load weight

Counter weight

The mechanical constant is calculated when the drive is turned on and re-calculated each time one of the parameters used to deter-
mine this value is modified (Mechanical calc mode, Full scale speed, Contract speed, Pulley diameter, Gearbox ratio).
The method used to calculate the mechanical constant can be selected regardless of the control mode (SSC, Flux vector OL, Flux
vector CL) or the unit of measure to be used.

Weights and inertia


Entering the mechanical features of the system makes it possible to calculate the total inertia applied to the motor.
After modifying these parameters the calculated inertia value is automatically saved in the “Inertia comp” parameter to enable cor-
rect inertia compensation.
The value of the inertia that can be entered in the “Inertia“ parameter in the “16 - SPEED REG GAINS” menu is displayed to calcu-
late the speed loop parameters more accurately. This operation is performed automatically when PAR 11162 Calc spd reg gain is
enabled.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.1 11006 Contract speed m/s FLOAT 0.5 0 10 RW FVS


Represents the speed of the system. It is also used to calculate the mechanical constant. The cabin speed in m/s is as-
sociated with the full scale speed (par. 628) to obtain the conversion factor (m/rpm).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.2 11008 Mechanical calc mode


INT16 0 0 1 ERW
FVS
Setting of the method for calculating the unit of measure, depending on the speed of the cabin and of the motor (Direct
method) or according to the mechanical ratios (Mechanical data method).

0 Direct method
1 Mechanical data

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.3 11010 Gearbox ratio


FLOAT 90 ERW
FVS
Setting of the ratio between the speed of the motor and of the pulley.

24 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.4 11012 Pulley diameter m


FLOAT 0.60 ERW
FVS
Setting of the diameter of the pulley.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.5 11150 Car weight kg


FLOAT 0.00 RW
FVS
Setting of the weight of the cabin.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.6 11152 Counter weight kg


FLOAT 0.00 RW
FVS
Setting of the weight of the counterweight.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.7 11154 Load weight kg


FLOAT 0.00 RW
FVS
Setting of the weight of the maximum load for system dimensions.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.8 11156 Rope weight kg


FLOAT 0.00 RW
FVS
Setting of the weight of the cable.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.9 11158 Gearbox inertia kgm²


FLOAT 0.00 RW
FVS
Setting of the inertia of the mechanical reducer.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.10 11160 Motor inertia kgm²


FLOAT 0.00 RW
FVS
Setting of the motor inertia.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.11 11162 Calc spd reg gains


ENUM
INT 0 0 1 RW
F__
If enabled this writes the inertia value in parameter 2240 Inertia, calculates the gains of the speed loop, sets parameters
2200 to 2210 to 100% and writes the calculated values in parameters 2236 Speed reg P gain, 2238 Speed reg I time and
2242 Bandwidth. The value of the parameter is automatically reset to 0 once calculation starts.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.12 12020 Inertia calculated kgm²


FLOAT 0 R
FVS
The inertia of the system with half load applied to the motor is displayed. This value can be entered in the Inertia parameter
in the “16 - SPEED REG GAINS” menu.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.4.13 12022 SpeedLineCalc m/s


FLOAT 0 R
FVS
The linear speed in m/s calculated using the 11010 Gearbox ratio and 11012 Pulley diameter parameters is displayed.

VDL200 • Functions description and parameters list 25


5.5 – DISTANCE
Use of the distances facilitates positioning of the deceleration sensors and is helpful for managing short floors.
The aim of the function that considers distances is to start decelerating from high speed in order to reach the approach speed in
proximity to the landing zone.
Up to a maximum of 8 different slow down distances can be managed (real distance between the start of the sensor and the floor)
associated with the different multispeeds. The distance to be used is selected after enabling the drive, before the cabin starts to
move. Different distances cannot be selected while the cabin is travelling.
If the slow down distance is shorter than the real deceleration distance for the selected target speed, the speed is automatically
limited so that the stop is always correct. When this speed limiter is enabled a Speed target alarm (warning) is generated.

High Speed

Speed Limit

Distance function: Speed limits

d1 = Speed limiter (Speed Limit


d2 = High speed

d1
d2

If the slow down sensor is met during acceleration, the distance required to terminate the acceleration and deceleration phases may
be greater than the distance available: in that case the last acceleration jerk is increased to enable correct landing.

Acc end jerk


Distance function: Short floor

..... Distance disabled


__ Distance enabled (Short floor)
__ Standard floor

d1 Distance
disabled d1
Piano corto (Short Floor) Piano standard (Standard Floor)

Also note that when the position sensor is not enabled in the landing zone, its exact length is not known. To ensure correct decel-
eration this distance is estimated on the basis of the value entered in the Landing zone dist parameter.
When this is equal to zero the distance is calculated on the basis of the value of the low speed and deceleration parameters and
shown in the Landing zone space parameter. The user should make sure this distance is approximately the real length of the land-
ing zone.
In FOC mode the distance is calculated by reading the encoder position.
In the SSC and SLS modes the distance is estimated (SpdRef*Time) and is thus subject to errors due to the difference between the
real speed of the motor and the speed reference.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.1 11102 Distance multispeed0 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 0.

26 VDL200 • Functions description and parameters list


Slow Down
sensor

Lift car

Slow distance

Landing distance
Floor level

Landing sensor

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.2 11104 Distance multispeed1 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 1.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.3 11106 Distance multispeed2 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 2.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.4 11110 Distance multispeed3 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 3.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.5 11112 Distance multispeed4 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 4.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.6 11114 Distance multispeed5 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 5.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.7 11116 Distance multispeed6 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 6.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.8 11118 Distance multispeed7 m


FLOAT 0.00 0.00 10.00 RW
FVS
Setting of the value of the distance associated with multispeed 7.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.9 11120 Slow speed


UINT16 0 0 9 RW
FVS
Setting of the floor approach speed.
The Slow speed is the speed of approach to the landing zone. When the multispeed associated with the Slow speed is
selected the slow down space is checked in order to reach this speed in proximity to the landing zone.
0 Autoselect
1 Multispeed 0
2 Multispeed 1
3 Multispeed 2
4 Multispeed 3
5 Multispeed 4
6 Multispeed 5
7 Multispeed 6

VDL200 • Functions description and parameters list 27


8 Multispeed 7
9 Null

When mode 0 (Autoselect) is selected, Slow speed is automatically connected to the multispeed with absolute value of
less and other than zero. If repositioning speeds with a value of less than the Slow speed are used, the multispeed cor-
responding to the floor approach speed must be set.
When mode 9 (Null) is selected the floor approach spaces are never controlled. In this case the profile depends exclu-
sively on the multispeed selected.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.10 11130 Enable landing sel


INT16 0 0 1 RW
FVS
Setting for enabling space control in the landing zone.
This function enables the cabin to arrive exactly at floor level by controlling the position of the encoder in the landing zone
sensor. Position control is only possible if an encoder is used (normally in FOC-BRS). SSC and SLS modes simply gener-
ate an appropriate profile on the position reference.
When the function is enabled, the Slow speed, PAR 11120 (speed at which the cabin enters the landing zone) no longer
depends on the relative multispeed but is calculated automatically according to the jerk and deceleration values to enable
stopping without exceeding the set limits.
The value of Slow speed (PAR 11120 = 1...8) is calculated using the jerk and deceleration values not multiplied by the
ramp factor.
During the landing procedure the speed profile is calculated using the fifth-degree polynomial method.
Direct arrival at floor level is also possible, without using the Slow speed. This is done by setting the Slow speed multi-
speed value to zero.

0 Off
1 On

Given the solution that has been selected to calculate the speed profile, before enabling the landing zone function it is im-
portant to verify the exactness of the spaces that have been entered (for both slow down and landing), and of the mechani-
cal constants. Incorrect spaces could result in sudden decelerations and errors in arrival at floor level.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.11 11132 Landing zone dist m FLOAT 0.12 0 10.00 RW FVS


Setting of the landing zone distance.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.12 11138 Out floor function


BIT 0 0 1 RW
FVS
Enabling of the safe start function when not at floor level. This function enables recognition of arrival at floor level, which is
assumed to be correct if the landing zone phase is performed.
If a correct stopping sequence is not recognised this means an emergency stop command has been sent, after which a low
speed start is generated.
The restart procedure depends on the stop position as shown in the figure.

0 OFF
1 ON

Speed

High speed
Case 1

Off-floor, far from Slow Down


Slow speed

Distance Slow Down

28 VDL200 • Functions description and parameters list


Speed

Case 2
Slow speed Close to Slow Down

Slow Down Land


Distance

Speed
Case 3

Slow speed After Slow Down

Slow Down Land


Distance

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.13 11140 Delay acq time m FLOAT 15 0.00 10.00 RW FVS


Setting of the delay time for sending the slow down signal.
The value of this parameter is used to compensate for the distance covered during the delay time between the passage
of the cabin on the slow down sensor and receipt of the decelerate command by the drive. At high speeds this distance
can have significant values: e.g. with a cabin travelling at 2 m/s and a delay time of 30 ms, the distance covered and to be
taken into consideration during the deceleration phase is 6 cm.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.14 11142 Calc space hi-speed


UINT16 1 0 8 RW
FVS
Setting of the high speed to be used to calculate distances.
0 Multispeed 0
1 Multispeed 1
2 Multispeed 2
3 Multispeed 3
4 Multispeed 4
5 Multispeed 5
6 Multispeed 6
7 Multispeed 7
8 Null

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.15 11276 Kp Landing Float 0.0000 0 100 RW FVS


Lets you configure proportional gain to control the landing curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.16 12030 Acceleration space m


FLOAT 0 R
FVS
The distance necessary to accelerate from zero speed to the high speed selected in the previous parameter is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.17 12032 Deceleration space m


FLOAT 0 R
FVS
The distance necessary to stop from the high speed is displayed.

VDL200 • Functions description and parameters list 29


Different methods are used to calculate this distance, depending on the value of the relative parameters:
Speed

PAR 11142
Calc space speed

Case 1
PAR 12032
Deceleration space

Time

●● Case 1: -shaped ramp from high speed to zero speed


Distance multispeed0 (PAR 11102) = 0, Enable landing sel (PAR 11130) = Disabled, Slow speed (PAR 11120) = Zero.

Deceleration space (PAR 12032) the distance covered during the stop ramp from Calc space hi-speed (PAR 11142)
(high speed) to zero speed.
The parameters that influence the calculation of this distance are: Calc space hi-speed (PAR 11142), Percent dec factor
(PAR 11056), Dec ini jerk (PAR 11046), Deceleration (PAR 11048) and Dec end jerk (PAR 11050).

Speed

PAR 11142
Calc space speed
Case 2

PAR 12032
Deceleration space = A+B

PAR 11020
Slow speed PAR 11052
End deceleration

Time

●● Case 2: S-shaped ramp from high to low speed, low speed zone and subsequent stop
Distance multispeed0 (PAR 11102) = 0, Enable landing sel (PAR 11130) = Disabled, Slow speed (PAR 11120) = Multi-
speed 0.

Deceleration space (PAR 12032) is the distance covered during the slow down ramp from Calc space hi-speed (PAR
11142) (high speed) to Multispeed 0 and during the stop ramp from Calc space hi-speed (PAR 11142) to zero speed. It
does not include the distance covered at constant speed (Low speed).
The parameters that influence the calculation of this distance are: Calc space hi-speed (PAR 11142), [11022] Multispeed
0 (PAR 11020), Percent dec factor (PAR 11056), Dec ini jerk (PAR 11046), Deceleration (PAR 11048), Dec end jerk
(PAR 11050) and Stop deceleration (PAR 11052).

Speed

PAR 11142
Calc space speed
Case 3

PAR 12032
Deceleration space = A+B

PAR 11020
Slow speed
PAR 11052
End deceleration

Time

●● Case 3: S-shaped ramp from high to low speed, low speed zone and subsequent stop
Distance multispeed0 (PAR 11102) ≠ 0 (es.0.5m), Enable landing sel (PAR 11130) = Disabled, Slow speed (PAR
11120) = Multispeed 0.

Deceleration space (PAR 12032) is the distance covered during the slow down ramp from Calc space hi-speed (PAR
11142) to Multispeed 0 and during the stop ramp from Calc space hi-speed (PAR 11142) to zero speed. It does not
include the distance covered at constant speed (Low speed).
The parameters that influence the calculation of this distance are: Calc space hi-speed (PAR 11142), [11022] Multispeed 0
(11020), Percent dec factor (PAR 11056), Dec ini jerk (PAR 11046), Deceleration (PAR 11048) and Dec end jerk (PAR 11050).

30 VDL200 • Functions description and parameters list


Speed

PAR 11142
Calc space speed

Case 4
PAR 12032
Deceleration space = A+Landing zone dist

PAR 11132
Landing zone dist

Time

●● Case 4: S-shaped ramp from high to low speed, low speed zone and subsequent stop with “landing control”

Distance multispeed0 (PAR 11102) ≠ 0 (es.0.5m), Enable landing sel (PAR 11130) = Enabled, Slow speed (PAR
11120) = Multispeed 0.

Deceleration space (PAR 12032) is the distance covered during the slow down ramp from Calc space hi-speed (PAR
11142) (high speed) to Multispeed 0 plus Landing zone dist (PAR 11132).
The parameters that influence the calculation of this distance are: Calc space hi-speed (PAR 11142), [11022] Multispeed
0 (PAR 11020), Percent dec factor (PAR 11056), Dec ini jerk (PAR 11046), Deceleration (PAR 11048) and Dec end jerk
(PAR 11050)

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.5.18 12034 Landing zone space m


FLOAT 0 R
FVS
The landing zone space is displayed. If this parameter is set to a value other than zero, this variable has the same value
as the parameter, if Landing zone space = 0 this variable assumes the value of the distance necessary to decelerate from
the speed set in Slow speed to zero using the ramp values not multiplied by the Percent dec factor.

VDL200 • Functions description and parameters list 31


5.6 – EMERGENCY MODE
The possibility of operating on an emergency module power supply has been implemented in the drive, to overcome the problem of
sudden power failures.
The emergency operation condition signal must be connected to the Emergency command input (digital input 3 as default) which,
if active, disables the undervoltage alarm so that the drive can operate powered on the DC link by the EMS emergency module
(which is in turn powered by a buffer battery pack).
In order to use batteries with a lower power rating, a function has been implemented to allow the desired direction of travel to be
selected before starting an emergency start procedure.
The direction is selected after testing the movement in both directions, choosing the one that requires less current (for more details
see EMS manual).
In case of a blackout the drive can be powered by an Emergency Module Supplier (EMS) or by an Uninterruptible Power Supply
(UPS).
The emergency function signal must be connected to the input of the Emergency Mode command (default digital input DI3).

Operation with Emergency Module Supplier (EMS)


If digital input 3 DI3 is active, the Undervoltage (UV) alarm refers to the value set in parameter 448 (menu 4), allowing the drive to
run powered on the DC link. See the VDL200 Quick Start manual (paragraph 7.3.3) and the EMS Manual for the connection.

Operation with Single-phase Uninterruptible Power Supply (UPS)


When the emergency is activated by digital input DI3, the Drive can be powered by a 230V single-phase UPS. See the VDL200
Quick Start manual (paragraph 7.3.3) for the connection.

Arrival at floor in Emergency


For both closed-loop and open-loop configurations, arrival at the floor in an emergency is managed by trying to optimize the request
for current to the emergency modules.
The drive can select the more favorable direction for arriving at the floor without forward/reverse movements, thereby protecting the
parts in emergency.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.6.1 11260 Speed emergency mode Hz FLOAT 5.00 3.40E+94 3.40E+94 RW FVS
Setting of the speed during movements in the emergency operation condition. Given the low voltage, high speeds cannot
be reached with the drive powered by battery (or emergency module). The speed selected in the multispeed parameter is
therefore ignored and this value is used instead.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.6.2 11262 Autoselect direction


BIT 0 0 2 ERW
FVS
Enabling of automatic selection of preferred direction before an emergency start.
0 OFF
1 ON
2 Recommended

This parameter lets you select how the drive calculates the more favorable riding direction of the cabin when it is in emer-
gency mode.
If 0 is selected, the drive does not calculate the more favorable direction, which is commanded manually.
If 1 is selected, as soon as the drive is in emergency condition it moves the motor with alternating forward and reverse
movements, calculating the value of the current delivered in each direction, and selects the more favorable one (less cur-
rent requested).
If 2 is selected (recommended mode), the drive evaluates the more favorable direction without making alternating forward
and reverse movements (avoiding requests for current from the EMS or UPS), already knowing the more favorable direc-
tion because it had already calculated it based on the value of current delivered and on the DC-Link voltage. If the drive
was in regeneration before the emergency, it keeps the same riding direction in emergency; if the drive was not in regener-
ation but was delivering current at a value below the value set in parameter PAR 11284 Detection Limit, it keeps the same
riding direction. Otherwise, the drive changes riding direction and considers the previous one unfavorable.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.6.3 11278 Em Dc brk current FLOAT 75.0 0 150 RW FVS


The parameter lets you set the braking current value by injecting DC in the motor windings. You can limit this value and
avoid overloading the emergency batteries.

32 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.6.4 11284 Detection Limit PERC LONG 50 0 100 RW FVS


This is the current limit value delivered by the drive (expressed as a percentage of nominal current) to select the more
favorable riding direction in Recommended mode (see PAR 11262).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.6.5 12282 Chosen Direction INT 0 *** *** R FVS


Indicates the direction selected by the drive during the emergency.

0 No direction selected
1 Forward
2 Reverse

The association Forward/Reverse and Up/Down depends on how the connection to the motor was made.

VDL200 • Functions description and parameters list 33


5.7 – INPUT/OUTPUT
Inputs
The lift application input commands can be connected to a signal via a selector in order to choose from a series of possibilities
available in the input list.
Generally speaking a signal can be connected to a digital input, to certain internal signals and to a bit of the Decomp word bit. This
word is connected to a fieldbus processing channel (PDC FieldBus M->S1).
The set of digital inputs in a word is displayed in the Lift control word.
The commands used in the lift application are listed below

Command Description Default Source


EnableCmd Enable command Dig input enable
StartFwdCmd Start forward command Dig input 1x
StartRevCmd Start reverse command Dig input 2x
MltSpd S0 Multispeed 0 sel Dig input 4x
MltSpd S1 Multispeed 1 sel Dig input 5x
MltSpd S2 Multispeed 2 sel Dig input 6x
ContFbk Contactor close contact Run cont mon
BrakeFbk Brake close contact Brake cont mon
DoorOpenEna Source for enabling the door open function Null
DoorFbk Door close contact Null
Emergency mode Emergency operation command Dig input 3x
InvRampSrc Command to invert the speed direction Null
UpperLimit Travel upper limit signal Null
LowerLimit Travel lower limit signal Null

Outputs
The output signals of the lift control are connected directly to the PAD parameters as shown in the table below:

PAR Signal Description


3700 Lift enable LiftEnable Enable lift command
3702 Run cont mon RunCont Close contactor command
3704 Up cont mon UpCont Up contactor command
3706 Down cont mon DownCont Down contactor command
3708 Brake cont mon BrakeCont Brake command
3710 Lift dc brake LiftDcBrake DC brake function command
3712 Brake 2 mon Brake2 Brake control signal
3714 Door open mon DoorOpen Open door command
3716 Lift start LiftStart Start lift command
3718 PAD10 -----
3720 Lift status word Lift status word Contains pairs of the StatusWord (selectable from SelLiftStatWord)
3722 PAD12 -----
3724 PAD13 -----
3726 Ramp down limit ----- Ramp down current limit
3728 PAD15 -----
3730 Lift wdec input LiftWdecInp Connected to the selector for LifWDecomp

These can be accessed from the selection lists and can thus easily be used to configure the relay and digital outputs of the drive.
(refer to the PADS menu for configuration).
The set of lift output signals is contained in the LiftStatusWord, connected to PAR 3720 Lift status word and fieldbus Tx DW1:

Bit Description Notes


0 LiftEnable Enable lift command.
1 RunCont Run command contactor
2 UpCont Up command contactor
3 DownCont Down command contactor
4 BrakeCont Brake command contactor
5 LiftDcBrake DC brake function command (firmware)
6 Brake2 Brake control signal (see sequences)
7 DoorOpen Open door command
8 Drive Ok Drive not in alarm condition signal
9 SpeedIsZero Speed less than 0 limit signal
10 SpeedRefIsZero Speed reference less than 0 limit signal
11 ... 12

34 VDL200 • Functions description and parameters list


Multi speed configuration table
Multi speed S2 sel Multi speed S1 sel Multi speed S0 sel ACTIVE RAMP REF
0 0 0 Multi speed 0
0 0 1 Multi speed 1
0 1 0 Multi speed 2
0 1 1 Multi speed 3
1 0 0 Multi speed 4
1 0 1 Multi speed 5
1 1 0 Multi speed 6
1 1 1 Multi speed 7

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.1 11220 Lift enable cmd sel


ENUM 1110 ERW
FVS
Setting of the source for the enable command.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.2 11222 Start fwd cmd sel


ENUM 1210 ERW
FVS
Setting of the source for the start forward command.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp

VDL200 • Functions description and parameters list 35


12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.3 11224 Start rev cmd sel


ENUM 1212 ERW
FVS
Setting of the source for the start reverse command.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.4 11226 Multi speed S0 sel


ENUM 1216 ERW
FVS
Setting of the source for the first multispeed selection bit.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp

36 VDL200 • Functions description and parameters list


12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.5 11228 Multi speed S1 sel


ENUM 1218 ERW
FVS
Setting of the source for the second multispeed selection bit.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.6 11230 Multi speed S2 sel


ENUM 1220 ERW
FVS
Setting of the source for the third multispeed selection bit.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp

VDL200 • Functions description and parameters list 37


12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.7 11232 Contactor fbk sel


ENUM 3702 ERW
FVS
Setting of the source of the contactor status signal.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.8 11236 Brake fbk sel


ENUM 3708 ERW FVS
Setting of the source of the brake status signal.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp

38 VDL200 • Functions description and parameters list


12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.9 11238 Door open sel


ENUM 6000 ERW
FVS
Setting of the source to enable door closing control.

1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.10 11240 Door feedback sel


ENUM 6000 ERW
FVS
Setting of the source of the door status signal.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One

VDL200 • Functions description and parameters list 39


12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.11 11242 Emergency mode sel


ENUM 1214 ERW
FVS
Setting of the source of the emergency operation signal.

1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.12 11244 Inversion ramp sel


ENUM 6000 ERW
FVS
Setting of the source of the command that inverts the direction of the output speed.

1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One

40 VDL200 • Functions description and parameters list


12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.13 11246 Upper limit sel


ENUM 6000 ERW
FVS
Setting of the source of the upper limit enabling signal.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.14 11248 Lower limit sel


ENUM 6000 ERW
FVS
Setting of the source of the lower limit enabling signal.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
3728 PAD 15
6000 Null

VDL200 • Functions description and parameters list 41


6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.15 11252 Brake fbk A3 sel


ENUM 0 RW
FVS
Selection of the brake fault alarm In the default configuration the brake fault alarm function is disabled.
Setting of the source to enable:
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp
13000 F0 Rising
13001 F0 Falling
13002 F1 Rising
13003 F1 Falling

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.16 11256 SpeedRefSrc


ENUM 0 0 1 RW
FVS
Selection of the origin (source) of the signal to be used for the speed reference. The signals that can be used are multi-
speed, analog input.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.17 11258 Lift EF alarm sel


ENUM 0 0 1 RW
FVS
Selection of the origin (source) of “Lift external fault”.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

42 VDL200 • Functions description and parameters list


5.7.18 11274 Landing Cmd src
ENUM NULL RW
FVS
You can enable the Landing command with the Start signal as well as from Digital Inputs and Freeze inputs. If you select
Freeze inputs, the command is activated on the encoder inputs (see the VDL200 Quick Start manual to identify the encode
Freeze inputs).
Rising (rising/positive edge) means active on the rising edge of the signal; Falling (falling/negative edge) active on the fall-
ing edge.
1110 Digit input E
1210 Digit input 1x
1212 Digit input 2x
1214 Digit input 3x
1216 Digit input 4x
1218 Digit input 5x
1220 Digit input 6x
1222 Digit input 7x
1224 Digit input 8x
3702 Run cont mon
3706 Down cont mon
3708 Brake cont mon
3714 Door open mon
6000 Null
6002 One
12250 B0 Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
12262 B6 Lift decomp
12264 B7 Lift decomp
12266 B8 Lift decomp
12268 B9 Lift decomp
12270 B10 Lift decomp
12272 B11 Lift decomp
12274 B12 Lift decomp
12276 B13 Lift decomp
12278 B14 Lift decomp
12280 B15 Lift decomp
13000 F0 Rising
13001 F0 Falling
13002 F1 Rising
13003 F1 Falling

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.19 12102 Command input mon


UINT32 0 ER
FVS
The hexadecimal value of the input status is displayed, refer to the “lift control word” for a description of the meaning of each bit.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.7.20 12104 Command output mon


UINT32 0 ER
FVS
The hexadecimal value of the input status is displayed, refer to the “lift status word” for a description of the meaning of each bit.

VDL200 • Functions description and parameters list 43


5.8 –PRE - TORQUE
The Pre-torque function helps to guarantee a linear start without any initial acceleration. This is possible by setting a torque value
that corresponds to the load before opening the brake. The value of the initial torque applied to the motor and the direction of the
torque applied can be supplied by installing a load cell on the lift cabin. The load cell signal is acquired via the analog input and ap-
propriately scaled if using the Pre-torque function.
If a load cell is not installed, a fixed torque value can be used, only supplying the direction of torque. In that case the fixed torque
value is only optimised for one load condition.

Speed + PAR 12058


regulator  Torque ref
PAR 11178 +
Pre-torque gain
PRE-TORQUE BLOCK PAR 12056
PAR 11168 Constant Torque ref 2 src
Pre-torque src PAR 12056
PAR 11166 t Pre-torque out
Pre-torque enable

Ramp

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.1 11166 Pre-torque enable


BIT 0 0 1 RW
F
Enabling of the pre-torque function
0 OFF
1 ON

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.2 11168 Pre-torque source INT16 11170 0 2 RW F


Selection of the origin (source) of the signal used for the pre-torque function.
1600 Analog inp 1
4034 FieldbusM->S2
4044 FieldbusM->S3
4054 FieldbusM->S4
4064 FieldbusM->S5
4074 FieldbusM->S6
4084 FieldbusM->S7
4094 FieldbusM->S8
4104 FieldbusM->S9
4114 FieldbusM->S10
4124 FieldbusM->S11
4134 FieldbusM->S12
4144 FieldbusM->S13
4154 FieldbusM->S14
4164 FieldbusM->S15
4174 FieldbusM->S16
11170 Int pretorque

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.3 11170 Init pre-torque


INT32 1000 RW
F
Setting of the reference value used in the pre-torque function only if the Pre-torque source parameter is set to 0. The value
set in this parameter only enables the pre-torque function to be optimised for one load condition. The pre-torque function
can also be optimised for different load conditions by using the fieldbus to modify the setting of this parameter.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.4 11172 Pre-torque ramp up ms


INT32 0 0 10000 RW
F
Setting of the ramp time for the rising edge of the torque value (before opening the brake): if this parameter is set to zero
the constant feed-forward torque value is maintained during travel.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.5 11174 Pre-torque ramp down ms


INT32 0 0 60000 RW
F
Setting of the ramp time for the falling edge of the torque value: if this parameter is set to zero the constant feed-forward
torque value is maintained during travel.

44 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.6 11176 Pre-torque offset


FLOAT 0 RW
F
Setting of the offset value applied to the input reference of the pre-torque function.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.7 11178 Pre torque gain


FLOAT 1 RW
F
Setting of the gain value used to convert the value applied to the analog input in the torque value to be used in the func-
tion. This gain is calculated automatically according to the weights and inertia values entered. Ideally, the reference must
be set so that the minimum value corresponds to the empty cabin and the maximum value to the full load.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.8 12040 Pre-torque input cnt


INT32 0 ER
F
The reference value sampled at start is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.9 12056 Pre-torque out cnt


INT32 0 ER
F
The feed forward torque value output of the pre-torque function is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.8.10 12058 Torque reference cnt


INT32 0 ER
F
The torque reference value is displayed, given by the sum of the speed loop output and the torque feed forward.

VDL200 • Functions description and parameters list 45


5.9 – LIFT ALARMS
The MdPlc application for VDL200 manages and generates the following alarms:

Alarm Alarm type Description


Plc1 fault Cont feedback Contactor feedback signal error
Plc2 fault Brake feedback Brake feedback signal error
Plc3 fault Door feedback Door feedback signal error
Plc6 fault Speed limited Warning of speed limit to guarantee stop
Plc7 fault Up/low limit Speed limit exceeded in power factor regulation zone

All alarms are associated with a parameter to configure the action taken when the alarm is activated.
Activity: used to set the action to be performed after activation of the alarm, as follows.

Action
Ignore The alarm is not included in the alarm list, it is not included in the alarm log, it is not signalled on the
digital outputs, commands to the drive are not modified.
Warning The alarm is included in the alarm list, it is included in the alarm log, it is signalled on the digital
outputs, First alarm information is updated, Enabled alarms information is updated, commands to the
drive are not modified.
Disable The alarm is included in the alarm list, it is included in the alarm log, it is signalled on the digital out-
puts, First alarm information is updated, Enabled alarms information is updated, a stop command is
sent, the motor is disabled and stops due to inertia.
Fast Stop The alarm is included in the alarm list, it is included in the alarm log, it is signalled on the digital
outputs, First alarm information is updated, Enabled alarms information is updated, a Stop command
is sent. The drive is set to zero speed with the maximum available current; when the Speed 0 delay
signal is activated the drive is disabled.
Lift Fast stop When there is an alarm occurrence, lift will be stopped (ramp reference is set to zero) immediately
with fast ramp, after that it will remain in alarm state. Attention: this will cause the cabin to stop out of
floor !
Lift stop When there is an alarm occurrence, lift will continue to run until next stop condition, after that it will
remain in alarm state.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.1 11058 Lift fast stop fact FLOAT 10.00 1.00 50.00 RW FVS
This parameter is applied to all ramps when a “Quick stop” alarm occurs.
The default setting is 10 = 1000% (standard ramps multiplied by 10).
To use standard ramps with no multiplication, set 1 = 100%.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.2 11200 Contactor activity


INT16 1 0 5 RW
FVS
Setting of drive behaviour in case of a Cont fbk fail alarm. This alarm indicates that the feedback confirming closing of the
contactor has not been received.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.3 11202 Cont hold off ms


INT32 3000 RW
FVS
Setting of the delay time between activation of the Cont fbk fail alarm condition signal and the actual alarm. In case of an
alarm condition, the drive waits for the set time to elapse before activating the alarm. If the alarm is removed within the set
time, the drive will not activate the alarm.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.4 11204 Brake activity


INT16 1 0 5 RW
FVS
Setting of drive behaviour in case of a Brake fbk fail alarm. This alarm indicates that the feedback confirming opening/clos-
ing of the brake has not been received.

46 VDL200 • Functions description and parameters list


0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.5 11206 Brake hold off ms


INT32 3000.00 RW
FVS
Setting of the delay time between activation of the Brake fbk fail alarm condition signal and the actual alarm. In case of an
alarm condition, the drive waits for the set time to elapse before activating the alarm. If the alarm is removed within the set
time, the drive will not activate the alarm.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.6 11208 Brake run hold off


INT16 1 0 1 RW
FVS
Setting of drive behaviour when a possible Brake fbk fail alarm is detected.
0 Disable
1 Enable

If set to 0 the brake feedback alarm is indicated immediately


If set to 1 the possible brake feedback alarm is indicated at the end of travel: this allows the cabin to reach the floor in case
of a faulty brake status signal.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.7 11210 Door activity


INT16 1 0 5 RW
FVS
Setting of drive behaviour in case of a Door fbk fail alarm. This alarm indicates that the feedback confirming opening of
the door has not been received.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.8 11212 Door hold off ms


INT32 1000 RW
FVS
Setting of the delay time between activation of the Door fbk fail alarm condition signal and the actual alarm. In case of an
alarm condition, the drive waits for the set time to elapse before activating the alarm. If the alarm is removed within the set
time, the drive will not activate the alarm.

Door open src

Speed
Door open speed

Door open mon


No Alarm
Alarm Door fbk fail
Door fbk src

Door
Hold
off

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.9 11214 Limit activity


INT16 5 0 5 RW
FVS
Setting of drive behaviour in case of the Upper/Lower limit. This alarm occours when the speed is greather than PAR
11216 Limit speed thr and are active sensors installed at the beginning and end of the space. This function implemented
in the drive provides an additional control to avoid overtravel.
The alarm condition is generated, when the set speed limit is exceeded.

VDL200 • Functions description and parameters list 47


The UpperLimit or LowerLimit inputs must be set to enable speed limit control. The UpperLimit must always correspond to
the upper limit signal and the LowerLimit must always correspond to the lower limit signal.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.10 11216 Limit speed thr ms


INT32 1.000 RW
FVS
Setting of the speed threshold in the upper or lower limit zone.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

5.9.11 11218 Spd target activity


INT16 1 0 5 RW
FVS
Setting of drive behaviour in case of the Speed limit alarm. This alarm is activated if, using the EFC function, the slow
down distance is less than the real deceleration distance, thus enabling the speed limiter to ensure correct stopping.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.12 11264 Lift EF al activity
ENUM 5 0 5 RW
FVS
Setting of the “Lift external fault” alarm.
0 Ignore
1 Warning
2 Disable
3 Fast Stop
4 Lift Fast stop
5 Lift stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.13 11266 Lift EF hold off ms LONG 1000 0 60000 RW FVS
Maintaining the “Lift external fault” alarm.
“Lift EF” is displayed when a “Lift external fault” alarm occurs.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.14 11268 Reset Brake Alarm Short 0 - - RW FVS
Resets the Brake Alarm.
1. Open menu 5.9 LIFT ALARMS, and check that the Brake Alarm is on.
2. In the lift alarm menu, select parameter 11268 Reset Brake Alarm (default 0).
3. The system asks for a code, enter release code 5313.
4. Check again to see whether the Brake Alarm has been reset.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.9.15 11270 Threshold A3 Float 0.100 0.000 2.000 RW
FVS
When the brake is connected, the Brake fault alarm is activated if the movement (in metres) is more than the value set in
parameter 11270 Threshold A3.

48 VDL200 • Functions description and parameters list


6-

7-

8-

9-
Note ! These menues are not available.

VDL200 • Functions description and parameters list 49


10 - DIGITAL INPUTS
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

10.01 1240 Dig inp 1X inversion


BIT 0 0 1 ERW
FVS
10.02 1242 Dig inp 2X inversion
BIT 0 0 1 ERW
FVS
10.03 1244 Dig inp 3X inversion
BIT 0 0 1 ERW
FVS
10.04 1246 Dig inp 4X inversion
BIT 0 0 1 ERW
FVS
10.05 1248 Dig inp 5X inversion
BIT 0 0 1 ERW
FVS
10.06 1250 Dig inp 6X inversion
BIT 0 0 1 ERW
FVS
10.07 1252 Dig inp 7X inversion
BIT 0 0 1 ERW
FVS
10.08 1254 Dig inp 8X inversion
BIT 0 0 1 ERW
FVS
10.09 1256 Dig inp 9X inversion
BIT 0 0 1 ERW
FVS
10.10 1258 Dig inp 10X inversion
BIT 0 0 1 ERW
FVS
10.11 1260 Dig inp 11X inversion
BIT 0 0 1 ERW
FVS
10.12 1262 Dig inp 12X inversion
BIT 0 0 1 ERW
FVS
Inversion of the logic status of the function associated with the digital input of the expansion card.

0 Off
1 On

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

10.13 1268 Dig input E dest


ILINK 0 0 0 ER
FVS
10.14 1270 Dig input 1X dest
ILINK 0 0 0 ER
FVS
10.15 1272 Dig input 2X dest
ILINK 0 0 0 ER
FVS
10.16 1274 Dig input 3X dest
ILINK 0 0 0 ER
FVS
10.17 1276 Dig input 4X dest
ILINK 0 0 0 ER
FVS
10.18 1278 Dig input 5X dest
ILINK 0 0 0 ER
FVS
10.19 1280 Dig input 6X dest
ILINK 0 0 0 ER
FVS
10.20 1282 Dig input 7X dest
ILINK 0 0 0 ER
FVS
10.21 1284 Dig input 8X dest
ILINK 0 0 0 ER
FVS
10.22 1286 Dig input 9X dest
ILINK 0 0 0 ER
FVS
10.23 1288 Dig input 10X dest
ILINK 0 0 0 ER
FVS
10.24 1290 Dig input 11X dest
ILINK 0 0 0 ER
FVS
10.25 1292 Dig input 12X dest
ILINK 0 0 0 ER
FVS
Selection of the destination of the digital input of the associated expansion card.

50 VDL200 • Functions description and parameters list


11 - DIGITAL OUTPUTS
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

11.01 1410 Dig output 1X src LINK 16BIT 1062 0 16384 ERW FVS
11.02 1412 Dig output 2X src LINK 16BIT 3708 0 16384 ERW FVS
11.03 1414 Dig output 3X src LINK 16BIT 3702 0 16384 ERW FVS
11.04 1416 Dig output 4X src LINK 16BIT 3714 0 16384 ERW FVS
11.05 1418 Dig output 5X src LINK 16BIT 1062 0 16384 ERW FVS
11.06 1420 Dig output 6X src LINK 16BIT 3708 0 16384 ERW FVS
11.07 1422 Dig output 7X src LINK 16BIT 3702 0 16384 ERW FVS
11.08 1424 Dig output 8X src LINK 16BIT 3714 0 16384 ERW FVS
The destination associated with the digital input of the expansion card is displayed. The functions that can be associated
with the digital outputs are listed in the “L_DIGSEL1” selection list”.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

11.09 1430 Dig out 1X inversion


BIT 0 0 1 ERW
FVS
11.10 1432 Dig out 2X inversion
BIT 0 0 1 ERW
FVS
11.11 1434 Dig out 3X inversion
BIT 0 0 1 ERW
FVS
11.12 1436 Dig out 4X inversion
BIT 0 0 1 ERW
FVS
11.13 1438 Dig out 5X inversion
BIT 0 0 1 ERW
FVS
11.14 1440 Dig out 6X inversion
BIT 0 0 1 ERW
FVS
11.15 1442 Dig out 7X inversion
BIT 0 0 1 ERW
FVS
11.16 1444 Dig out 8X inversion
BIT 0 0 1 ERW
FVS
Inversion of the logic status of the function associated with the digital output of the expansion card.
0 Off
1 On

VDL200 • Functions description and parameters list 51


12 - ANALOG INPUTS

Note ! These parameters are only available with cards provided with analog inputs.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.1 1600 Analog input 1X mon cnt INT16 16/32BIT 0 0 0 ER FVS


The value of the voltage on the output of the function block of the relative analog input is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.2 1602 Analog inp 1X type ENUM -10V..+10V 0 2 ERW FVS


Selection of the type of input (voltage or current). Depending on the input signal, move the switches on the regulation card.
The factory parameter is inputs set for differential voltage signals (± 10V).
0 -10V..+10V
1 0.20mA , 0.10V
2 4..20mA

Select option 0 in order to connect a maximum voltage of ±12.5V (typically ±10V/5mA) to the analog input concerned. If the
signal is used as a reference, reverse the direction of rotation by inverting the voltage polarity.
Select option 1 to connect a max voltage of 12.5V (typically 10V/5mA) or a signal in current from 0 ... 20 mA to the analog
input concerned. The signal must be positive.
Select option 2 to connect a current signal of 4...20 mA to the analog input concerned. The signal must be positive.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.3 1604 Analog inp 1X scale FLOAT 1.0 -10.0 10.0 ERW FVS
Setting of a multiplier factor to be applied to the relative analog input of the expansion card.

Speed

100%

2 1 Analog inp x scale = 1,0

2 Analog inp x scale = 2,0


50%

0
5V 10V

Example :
The speed reference of a drive is assigned with a max external voltage of 5V. With this value the drive must reach the
maximum speed allowed (set using Full scale speed).
As the Analog inp XX scale parameter the scale factor of 2 is entered (10V : 5V)

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.4 1606 An inp 1Xoffset tune BIT 0 0 1 ERW FVS


Self-tuning command for the offset of the relative analog input of the expansion card. Automatic fine tuning of the input.
To perform self-tuning, set the input signal to its minimum value and execute the command. The conditions containing an
offset can be compensated. When this command is sent, An inp xX offset tune is automatically selected so that the avail-
able input signal corresponds to the zero value of the variable.
Automatic tuning can only be performed if the following condition is present:
- Input voltage less than 1V or input current less than 2 mA

Note! The value that is obtained automatically can be changed manually, if necessary, using An inp offset xX.

52 VDL200 • Functions description and parameters list


If the voltage setting on the analog input is more than 1V the “Input value too high” message is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.5 1608 An inp 1X gain tune BIT 0 0 1 ERW FVS

Self-tuning command for the relative analog input gain. Automatic fine tuning of the input. When this command is sent, An
inp XX gain tune is automatically selected so that the available input signal corresponds to the maximum value of the vari-
able.
Two conditions are necessary in order to perform automatic tuning:
- Input voltage greater than 1V or input current greater than 2 mA
- Positive polarity. The value that is found is automatically accepted for the other direction of rotation.

Note! If necessary, the value obtained automatically can be changed manually via An inp XX gain tune.

To perform self-tuning, set the input signal to its maximum value and execute the command. A multiplier factor is calculated
to apply to the input signal value (not considering the Analog inp scale parameter) to reach the full scale value.
If the voltage setting on the analog input is less than 1V the “Input value too low” message is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.6 1610 Analog inp 1X filter ms UINT16 10 2 100 ERW FVS


Filter on the measurement of the corresponding analog input. This parameter can be used to control the response of the
analog input and reduce any possible noise and interference.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.7 1612 Analog inp 1X top cnt INT16 16384 -32768 +32767 ERW FVS
Setting of the upper speed reference limit as a function of the voltage (or current) of the relative analog reference of the
expansion card.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.8 1614 Analog inp 1X bottom cnt INT16 -16384 -32768 +32767 ERW FVS
Setting of the lower speed reference limit as a function of the voltage (or current) of the relative analog reference of the
expansion card.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.9 1616 Analog inp 1X offset cnt INT16 0 -32768 +32767 ERW FVS
AnInp Drive
PAR 1604 = 2
100%

PAR 1604 = 1

PAR 1616

AnInp Terminal
0 10V
100%

Setting of an offset value to algebrically add to the relative analog input of the expansion card..

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.10 1618 Analog inp 1X gain FLOAT 1.0 -10.0 10.0 ERW FVS
This parameter contains the value of the multiplier factor to apply to the analog reference of the expansion card calculated
using the Analog inp gain tune function.

VDL200 • Functions description and parameters list 53


Example :
An external analog reference only reaches a maximum of 9.8V instead of 10V. 1.020 (10V : 9.8V) is entered as the Analog
inp x gain parameter.
The same result can be achieved using the Analog inp x gain tune function. This parameter can be selected from the
keypad menu. The maximum analog value available (in this case 9.8V) must be present on the terminal, with positive
polarity. Press the Enter key on the keypad to start analog reference self-tuning.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.11 1626 An inp 1X sign src LINK 16BIT 6000 0 16384 ERW FVS
Selection of the origin (source) of the signal to be assigned to the relative digital input of the expansion card for selecting
the direction of rotation of the motor. The functions that can be associated with the digital outputs are listed in the “L_DIG-
SEL2” selection list”.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

12.12 1632 Analog input 1X dest ILINK 0 0 0 ER FVS


The function for which the relative analog input of the expansion card has been programmed and on which it acts is dis-
played.

54 VDL200 • Functions description and parameters list


13 -

Note ! This menue is not available.

VDL200 • Functions description and parameters list 55


14 - MOTOR DATA
From this menu you can enter the motor plate data and “basic” values for the voltage/frequency characteristics. It is important to
enter the correct data in order to optimize drive operation and that of the application as a whole. These data are required in order to
obtain:

a) Computation of the normalization factors necessary for regulation


b) Computation of the estimated values for the motor parameters necessary for regulation

Rated voltage, Rated speed, Rated frequency, Rated current, Cos phi, Basic voltage and Basic frequency must be entered (the Cos
phi default value can be used if this value it not present on the plate). After entering these parameters, send a Take parameters
command to calculate (a) and (b) above. The motor cannot be enabled until the Take parameters command has been set. If some
results are inconsistent, or if the motor is much smaller than the inverter, an error message is displayed indicating a numerical ca-
pacity overflow and the previous set of parameters is restored in the “Mot plate data” sub-menu.

Example of kW and HP motor data plates

P.2006 P.2000 P.2002 P.2006 P.2000 P.2002

Motor & Co. Motor & Co.


Type: ABCDE IEC 34-1 / VDE 0530 Type: ABCDE IEC 34-1 / VDE 0530
Motor: 3 phase 50 Hz Nr. 12345-91 Motor: 3 phase 60 Hz Nr. 12345-91
Rated voltage 400 V I nom 6.7 A Rated voltage 575 V I nom 2A
Rated power 3 kW Power factor 0.8 Rated power 2 Hp Power factor 0.83
Rated speed (nN) 1420 rpm Rated speed (nN) 1750 rpm Efficiency 86.5

IP54 Iso Kl F S1 IP54 Iso Kl F S1

Made in .............. Made in ..............

P.2012 P.2012

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.1 2000 Rated voltage V FLOAT SIZE 50.0 690.0 RWZS FVS
Set the motor rated voltage as indicated on the data plate. This is the voltage the drive must supply
at the motor rated frequency.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.2 2002 Rated current A FLOAT SIZE 1.0 1500.0 RWZS FVS
he motor rated current at its rated power (kW / Hp) and voltage (indicated on the motor data plate).
If using a single drive to control several motors connected in parallel (only possible in the SSC mode), enter a value that
corresponds to the sum of the rated currents of all the motors; in this case do not perform any “self-tuning operations”.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.3 2004 Rated speed rpm FLOAT SIZE 10.0 32000.0 RWZS FVS
Rated speed of the motor with full load in rpm (rpm = m-1). In some motors the synchronous speed (e.g. 1500 rpm for a
4-pole motor) and slippage, i.e. the loss of revolutions between the motor idling condition and the rated load condition (e.g.
80 rpm), is indicated. Enter the following: synchronous speed - slippage.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.4 2006 Rated frequency Hz FLOAT SIZE 10.0 1000.0 RWZS FVS
Rated frequency of the motor expressed in Hz, at which the flux weakening range starts.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.5 2008 Pole pairs UINT16 SIZE 1 20 RWZS FVS


Motor pole pairs. The number of motor pole pairs is calculated using the motor plate data and applying the following formula:

60 [s] x f [Hz]
p=
nN [rpm]

Where: p = motor pole pairs; f = motor rated frequency (PAR 2006)


nN = motor rated speed (PAR 2004)

56 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.6 2010 Rated power kW FLOAT SIZE 0.1 1500.0 RWZS FVS
Rated power of the motor at the rated voltage and frequency. This value represents the mechanical power produced on the
motor shaft.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.7 2012 Rated power factor FLOAT SIZE 0.6 0.95 RWZS FVS
Motor power factor, as indicated on the data plate (Cos j). This parameter is not always present on the motor data plate: in
that case use the default value present in the drive.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.8 2020 Take parameters


BIT 0 0 1 RWZ
FVS
Saves the set motor data in the drive. This command must be supplied last after entering the appropriate values of all the
parameters listed above. This means calculating the normalization factors (a) and estimated values for the motor param-
eters (b). The drive cannot be started until the Take parameters command has been set.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.9 2022 Autotune rotation


BIT 0 0 1 RWZ
FVS
Performs self-tuning in rotation: the motor must be uncoupled from the load or the transmission must not represent more
than 5% of the load. This procedure allows the greatest degree of accuracy in measuring the motor parameters. To ex-
ecute the command you must first open the hardware enabling contact between terminals 9 and DICM.
Selt-tuning can now be performed. At the end of the self-tuning procedure, open the contact between terminals 9 and
DICM again and reset the parameters that were modified.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.10 2024 Autotune still


BIT 0 0 1 RWZ
FVS
Performs self-tuning with the motor coupled to the transmission. The self-tuning procedure may cause limited rotation of
the motor shaft. To perform self-tuning, follow the procedure described for the previous parameter.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.11 2026 Autotune mode ENUM Reduced 0 1 ERWZ FVS


Selection of the motor parameter self-tuning mode
0 Reduced
1 Extended

If set to 0 all the motor parameters are measured except those relating to the non-linear saturation curve. Use this mode to
obtain a faster self-tuning procedure.
If set to 1 all the motor parameters are measured. Use this mode to obtain maximum efficiency: this procedure may take a
few minutes.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.12 2028 Take status ENUM Required 0 0 R FVS


Indication of the status of parameter saving.
0 Required
1 Done

The parameter displays the Required message when the motor parameters that have been entered need to be saved.
When they have been saved the parameter indicates Done.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.13 2030 Autotune status ENUM Required 0 0 R FVS


Indication of the status of execution of motor parameter self-tuning.
0 Required
1 Done
The parameter displays the Required message when motor parameter self-tuning is required. When self-tuning is com-
plete the parameter indicates Done.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.14 2050 Measured Rs ohm FLOAT CALCF 0.001 200.0 ERWS FVS
Measured value of the rotor resistance.

VDL200 • Functions description and parameters list 57


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.15 2052 Measured DTL V


FLOAT 0.0 0.0 100.0 ERWS
FVS
Measured value of dead time compensation.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.16 2054 Measured DTS V/A


FLOAT 0.0 0.0 100.0 ERWS
FVS
Measured compensation gradient value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.17 2056 Measured Lsig mH FLOAT CALCF 0.1 200.0 ERWS FVS
Measured leakage inductance value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.18 2058 Measured ImN A FLOAT CALCF 0.1 1000.0 ERWS FVS
Measured rated magnetizing current value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.19 2060 Measured ImX A FLOAT CALCF 0.0 0.0 ERWS FVS
Measured magnetizing current saturation value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.20 2062 Measured FlxN Wb FLOAT CALCF 0.05 10.0 ERWS FVS
Measured rated flux value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.21 2064 Measured FlxX Wb FLOAT CALCF 0.0 0.0 ERWS FVS
Measured flux saturation value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.22 2066 Measured P1 FLOAT 0.5 0.0 1.0 ERWS


FVS
Measured value of the first parameter to define the motor magnetization curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.23 2068 Measured P2 FLOAT 9.0 3.0 18.0 ERWS


FVS
Measured value of the second parameter to define the motor magnetization curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.24 2070 Measured P3 FLOAT 0.87 0.0 1.0 ERWS FVS


Measured value of the third parameter to define the motor magnetization curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.25 2072 Measured Rr ohm FLOAT CALCF 0.001 200.0 ERWS FVS
Measured rotor resistance value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

14.26 2078 Take tune parameters


BIT 0 0 1 ERWZ
FVS
Saves the motor data calculated by the self-tuning procedure in the drive.

Note! Data are not saved permanently. Use the “Save Parameters” command in the DRIVE CONFIG menu to save in the permanent memory.

58 VDL200 • Functions description and parameters list


15 - ENCODER CONFIG
The closed-loop control mode requires a speed reading by a digital encoder on the motor shaft. The natural variation in speed gen-
erated by machine load induction, known as slippage, can be compensated by the speed feedback supplied by the encoder in SSC
mode. In the field oriented vector mode, closed-loop encoder feedback is essential for correct drive operation.

Note ! This menu is only displayed if a feedback card is installed

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.1 2100 Encoder pulses ppr UINT16 1024 128 16384 RWZ FVS
Setting of the number of feedback encoder impulses. During setup this value is set automatically by reading the number of
incremental encoder impulses.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.2 2102 Encoder supply V FLOAT - - CALCF R FVS


Reading of the encoder supply voltage supplied by the relative optional card.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.3 2110 Encoder signal check ENUM Check A-B 0 3 ERWZ FVS
Configuration of which incremental digital encoder channels are to be controlled in order to process the Speed fbk loss
alarm signal.
0 Check disabled
1 Check A-B
2 Check A-B-Z
4 Check A-B-SE
Set 1 to check for signal on channels A-B
Set 2 to check for signal on channels A-B-Z
If set to 4 the encoder signals A and B are controlled in single-ended mode (single channel)

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.4 2130 Encoder direction ENUM Not inverted 0 1 RWZ FVS


Setting of the sign of the information obtained from the incremental or absolute encoder.
0 Not inverted
1 Inverted

By setting 0 the encoder feedback signals are not inverted.


By setting 1 the encoder feedback signals are inverted

According to international standards, positive references are associated with clockwise motor rotation, seen from the con-
trol side (shaft). To ensure correct operation, the regulation algorithms ensure that positive speed references correspond to
positive speed measurements.
If the motor pulley is mounted on the side opposite the command side, it will turn in an anticlockwise direction when the
speed is positive: to make the pulley turn in a clockwise direction, the motor phase sequence is modified, which inverts
the speed measurement sign. To restore the correct speed measurement sign, invert the incremental encoder A+ and A-
signals.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.5 2132 Encoder mode ENUM None CALCI CALCI ERWZ FVS
Setting of the method for measuring the speed of the encoder connected to the integrated card.

0 None (Default)
1 Digital FP
2 Digital F

Setting 1 (Digital FP) selects the method for measuring frequency and period. Selecting preferred.
Setting 2 (Digital F) selects the method for measuring frequency.

Note: There is no need to restart the drive when the mode is changed.

VDL200 • Functions description and parameters list 59


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.6 2134 Encoder speed filter ms FLOAT 2.0 0.1 20.0 ERW FVS
Setting of the time constant of the filter applied to the feedback encoder pulse reading. The parameter affects both the
accuracy of the speed measurement and the dynamics obtainable in closed loop control. On the other hand, the use of a
speed measurement filter introduces delays that do not permit high control loop dynamics. Low settings extend the regula-
tion bandwidth but may accentuate any disturbance. The filter is applied to the speed reported in the Encoder speed
parameter.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.7 2150 Encoder speed rpm INT16 16/32BIT 0 0 0 ER FVS


The motor speed measured by the incremental encoder is displayed, filtered by the Encoder speed filter parameter.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.8 2162 Encoder position cnt UINT16 16BIT 0 0 0 ER FVS


The impulse count obtained from the incremental encoder reading is displayed: 1 encoder turn is equal to the value en-
tered in Encoder pulses multiplied by 4.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

15.9 2172 SpdFbkLoss code UINT32 0 0 0 ER FVS


The Speed fbk loss alarm generated by an encoder fault is displayed. Each type of encoder generates the alarm differ-
ently (incremental signal error, absolute signal error, serial error), so this parameter is used to display information about the
alarm that has been activated. In case of several concurrent causes, these are shown in this parameter.

Bit Value Name


0 0x01 CHA
1 0x02 CHB
2 0x04 CHZ
3 0x08 MOD_INCR
4 0x10 MOD_ABS
5 0x20 CRC_CKS_P
6 0x40 ACK_TMO
7 0x80 DT1_ERR
8 0x100 Setup error

10..15 Free
16..31 Depends on the encoder

For further details reference should be made to the description of the Speed fbk loss alarm and to the SFL alarms chapter
according to the type of feedback.

Note ! For the correct interpretation of the cause of the alarm trigger, it is necessary to transform the hex code indicated in parameter 15.13 SpdFb-
kLoss code, PAR 2172 , in the corresponding binary and verify in the encoder table that the active bits and related description are used.
Example with digital incremental encoder:
PAR 2172 = 3 (hex value)
In the table “Speed fbk loss [22] alarm with digital incremental encoder” 0x03 is not indicated in the value column.
0x03 should be contemplated as a bitword with meaning 00011 -> bit 0 and bit 1 . The following causes simultaneously intervene:

Bit 0 = 0x01 Cause: no impulses or disturbance on incremental channel A.


Bit 1 = 0x02 Cause: no impulses or disturbance on incremental channel B.

60 VDL200 • Functions description and parameters list


16 - SPEED REG GAINS
The speed adaptive allows different speed regulator gains to be obtained according to the speed or another value. The behaviour of
the speed regulator can thus be configured in the best way for the specific application requirements.

Note ! C
urrent, flux and voltage regulators can be set using the self-tuning procedure. If this is not successful, current and flux regulators can be tuned
manually (this does not apply to voltage regulators, whch must not be modified by the user). The speed regulator must be tuned manually.
Gains are usually adjusted according to the drive speed.

Total gains used by the speed regulator are calculated as shown in the following examples. Results are in engineering units:
Speed reg P1 gain (PAR 2200)
Total proportional gain = * Speed reg P gain (PAR 2236)
100%

Speed reg I1 gain (PAR 2202) 1


Total integral gain = * Total proportional gain *
100% Speed reg I time (PAR 2238)

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.1 2200 Speed reg P1 gain perc INT16 100 0 1000 RW F_S
Setting of the proportional gain of the speed regulator, set 1.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.2 2202 Speed reg I1 gain perc INT16 100 0 1000 RW F_S
Setting of the integral gain of the speed regulator, set 1. Increasing the proportional gain value increases the proportional
action of the regulator

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.3 2204 Speed reg P2 gain perc INT16 100 0 1000 RW F_S
Setting of the proportional gain of the speed regulator, set 2.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.4 2206 Speed reg I2 gain perc INT16 100 0 1000 RW F_S
Setting of the integral gain of the speed regulator, set 2. Increasing the proportional gain value increases the proportional
action of the regulator

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.5 2208 Speed reg P3 gain perc INT16 100 0 1000 ERW F_S
Setting of the proportional gain of the speed regulator, set 3.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.6 2210 Speed reg I3 gain perc INT16 100 0 1000 ERW F_S
Setting of the integral gain of the speed regulator, set 3. Increasing the proportional gain value increases the proportional
action of the regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.7 2228 Speed reg P0 gain perc INT16 100 0 1000 ERW F_S
Setting of the proportional gain of the speed regulator at zero speed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.8 2230 Speed reg I0 gain perc INT16 100 0 1000 ERW F_S
Setting of the integral gain of the speed regulator at zero speed. Increasing the proportional gain value increases the pro-
portional action of the regulator

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.9 2218 Gain adp spd thr2_1 perc FLOAT 10.0 0.0 100.0 ERW F_S
Setting of the speed threshold for changing gains from set 1 to set 2.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.10 2220 Gain adp spd band2_1 perc


FLOAT 5.0 0.0 100.0 ERW
F_S
Setting of the band within which gains vary between set 1 and set 2. The use of this parameter ensures a smooth transition
between the two parameter sets.

VDL200 • Functions description and parameters list 61


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.11 2222 Gain adp spd thr3_2 perc


FLOAT 0.0 0.0 100.0 ERW
F_S
Setting of the speed threshold for changing gains from set 3 to set 2.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.12 2224 Gain adp spd band3_2 perc


FLOAT 0.0 0.0 100.0 ERW
F_S
Setting of the band within which gains vary between set 3 and set 2. The use of this parameter ensures a smooth transition
between the two parameter sets.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.13 2246 Gain adp spd thr0_2 perc


FLOAT 0.0 0.0 100.0 ERW
F_S
Setting of the speed threshold for changing gains from set 0 to set 2.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.14 2248 Gain adp spd band0_2 perc


FLOAT 0.0 0.0 100.0 ERW
F_S
Setting of the band within which gains vary between set 0 and set 2. The use of this parameter ensures a smooth transition
between the two parameter sets.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.15 2244 Gain profile mode ENUM Profilo 21 0 3 ERW F_S


Gain profile modes.
0 Profile 1
1 Profile 21
2 Profile 321
3 Profile 0213
●● If set to 0 the profile used is that shown in the figure below:
Gain

PAR 2200 %
Speed reg P1 gain

PAR 2202 %
Speed reg I1 gain

Speed reference

●● If set to 1 the profile used is that shown in the figure below:

Gain
PAR 2220
Gain adp spd band2_1 (%)

PAR 2204
Speed reg P2 gain (%)

PAR 2200
Speed reg P1 gain (%)

Speed ref

PAR 2206
Speed reg I2 gain (%)

PAR 2202
Speed reg I1 gain (%)

Speed ref
0
PAR 2218
Gain adp spd thr2_1 (%)

62 VDL200 • Functions description and parameters list


●● If set to 2 the profile used is that shown in the figure below:
Gain
PAR 2224 PAR 2220
Gain adp spd band3_2 (%) Gain adp spd band2_1 (%)

PAR 2208
Speed reg P3 gain (%)

PAR 2204
Speed reg P2 gain (%)

PAR 2200
Speed reg P1 gain (%)

Speed ref
PAR 2210
Speed reg I3 gain (%)

PAR 2206
Speed reg I2 gain (%)

PAR 2202
Speed reg I1 gain (%)

Speed ref
0
PAR 2222 PAR 2218
Gain adp spd thr3_2 (%) Gain adp spd thr2_1 (%)

●● If set to 3 the profile used is that shown in the figure below:

Gain PAR 2248


Gain adp spd band0_2 (%)

PAR 2224
_ _
Gain adp spd band3_2 (%)

PAR 2220
_
Gain adp spd band2_1 (%)
PAR 2228
Speed reg P0 gain (%)

PAR 2204
Speed reg P2 gain (%)

PAR 2200
Speed reg P1 gain (%)

PAR 2208
Speed reg P3 gain (%)

PAR 2230
Speed reg I0 gain (%)

PAR 2206
Speed reg I2 gain (%)

PAR 2202
Speed reg I1 gain (%)

PAR 2210
Speed reg I3 gain (%)

Speed ref

PAR 2246 PAR 2222 _


PAR 2218
Gain adp spd thr0_2 (%) Gain adp spd thr3_2 (%) Gain adp spd thr2_1 (%)

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.16 2232 Spd reg P gain Inuse perc INT16 16/32BIT 100 0 1000 ER F_S
The current proportional coefficient of the speed regulator is displayed as a percentage.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.17 2234 Spd reg I gain Inuse perc INT16 16/32BIT 100 0 1000 ER F_S
The current integral coefficient of the speed regulator is displayed as a percentage.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.18 2236 Speed reg P gain N/rpm FLOAT CALCF 0.0 500.0 ERWS F_S
Setting of the proportional coefficient of the speed regulator.

VDL200 • Functions description and parameters list 63


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.19 2238 Speed reg I time ms FLOAT CALCF 1.0 5000.0 ERWS F_S
Setting of the integral coefficient of the speed regulator. Reducing the integral time value increases the integral action of
the regulator.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.20 2240 Inertia kgm2 FLOAT SIZE 0.001 100.0 RWZS F_S
Setting of total inertia of the application with reference to the motor shaft. When this parameter is modified, all speed regu-
lator gains are initialised according to the value specified by parameter PAR 2242. An increase in the dynamic response of
the speed regulator to a variation in the reference, can be modified by changing the current value during the acceleration/
deceleration phase, to counter the applied machine inertia.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

16.21 2242 Bandwidth rad/s FLOAT SIZE 1.0 500.0 RWZS F_S
Setting of the bandwidth. Increasing the setting of this parameter increases the dynamic response and makes the system
more rigid.

64 VDL200 • Functions description and parameters list


17 - REGULATOR PARAM
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.1 2250 Current reg P gain V/A FLOAT CALCF 0.0 0.0 ERWS F_S
Setting of the proportional coefficient of the current regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.2 2252 Current reg I time ms FLOAT CALCF 0.01 10000.0 ERWS F_S
Setting of the integral coefficient of the current regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.3 2260 Flux reg P gain A/Wb FLOAT CALCF 0.0 0.0 ERWS F__
Setting of the proportional coefficient of the flux regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.4 2262 Flux reg I time ms FLOAT CALCF 0.01 10000.0 ERWS F__
Setting of the integral coefficient of the flux regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.5 2264 Flux reg P gain OL A/Wb FLOAT CALCF 0.0 0.0 ERWS __S
Setting of the flux regulator proportional gain when the drive is used in open loop sensorless vector control mode. This
parameter is set automatically by the self-tuning procedure.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.6 2266 Flux reg I time OL ms FLOAT CALCF 0.01 10000.0 ERWS __S
Setting of the flux regulator integral time when the drive is used in open loop sensorless vector control mode. This param-
eter is set automatically by the self-tuning procedure.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.7 2270 Voltage reg P gain Wb/V FLOAT CALCF 0.0 0.0 ERWS F_S
Setting of the proportional coefficient of the voltage regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.8 2272 Voltage reg I time s FLOAT CALCF 0.1 100.0 ERWS F_S
Setting of the integral coefficient of the voltage regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.9 2280 Dead time limit V FLOAT SIZE 0.0 50.0 ERWS FVS
Setting of the dead time voltage compensation value.
The dead time compensation function (Dead time compensation), compensates the distortion of output voltage caused
by the voltage drop on the IGBT devices and their switching characteristics.
Distortion of output voltage could cause irregular motor rotation.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.10 2282 Dead time slope V/A FLOAT SIZE 0.0 200.0 ERWS FVS
Setting of the dead time compensation slope value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.11 2290 Voltage base V FLOAT CALCF 50.0 690.0 ERWS F_S
Setting of the basic voltage of the motor. This parameter is calculated automatically by the self-tuning procedure.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.12 2292 Voltage margin perc FLOAT 5.0 0.0 10.0 ERWS F_S

VDL200 • Functions description and parameters list 65


Setting of the voltage regulation margin according to the available voltage. In case of a Voltage base setting close to or
equal to the actual mains value, Voltage margin represents the margin allowable by the voltage regulation to perform
rapid current variations when load steps are suddenly applied.
A value of 5% allows a very fast response to load steps but with a loss of output voltage and thus power output (reduced
power output).
The minimum value (1%) allows a maximum output voltage (around 98%) of the mains voltage to be achieved but with loss
of quality of the dynamic response.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.13 2300 Minimum speed OL rpm INT16 15 0 CALCI ERW __S


Setting of the minimum speed threshold in the sensorless vector control mode. Below this limit the sensorless regulator is
disabled.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.14 2302 Min speed delay OL ms UINT16 800 0 5000 ERW __S
Setting of the delay for disabling the sensorless regulator.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.15 2304 Speed filter OL ms FLOAT 5.0 0.1 20.0 ERWZ __S
Setting of the time constant for the estimated speed in sensorless vector mode. By increasing this parameter it is possible
to reduce the level of disturbance of the estimated speed, but the speed control dynamics are also lowered.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.16 2306 Flux observe gain OL FLOAT 500.0 10.0 5000.0 ERW __S
Flux observer gain in open-loop flux vector control mode.
In case of instability, try changing the value and setting half or twice the default value.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

17.17 2310 Flux weakening OL ENUM Disable 0 1 ERWZ __S


Enables or disables flux reduction in the open-loop flux vector control mode.
If set to Disable, the flux is not reduced when the speed of the motor exceeds the nominal speed. This results in loss of
control and instability.
This problem can be prevented by setting the parameter to Enable.
In the open-loop mode a flux value of less than the nominal speed of the motor is advantageous in terms of stability.

0 Disable
1 Enable

66 VDL200 • Functions description and parameters list


18 - TORQUE CONFIG
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.1 2350 Torque curr lim Pos A FLOAT 16/32BIT CALCF 0.0 CALCF ERWS FVS
Setting of the active torque limit of the drive for the positive current direction (clockwise rotation and anti-clockwise braking).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.2 2352 Torque curr lim Neg A FLOAT 16/32BIT CALCF 0.0 CALCF ERWS FVS
Setting of the active torque limit of the drive for the negative current direction (anti-clockwise rotation and clockwise braking).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.3 2354 Torque curr lim sel ENUM Sorg limcoppia 0 3 ERWZ FVS
Setting of the type of behaviour of the drive in the current limit condition.
0 Off
1 T clim +/-
2 T clim mot/gen
3 T limit src
If set to 0 no specific type of current limitation is set.
If set to 1 the active positive torque limit is Torque curr lim Pos and the active negative torque limit is Torque curr lim Neg.

torque torque

Torque curr lim Pos Torque curr lim Pos Torque curr lim Pos

Torque curr lim Neg

speed speed

Torque curr lim Neg


Torque curr lim Neg Torque curr lim Neg
Torque curr lim Pos

-1% of Rated speed +1% di Rated speed

Torque limits with Torque curr lim Sel = 1 Torque limits with Torque curr lim sel = 2

If set to 2 three conditions are possible:


1 – If the motor speed is > +1% of Rated speed the active positive torque limit is Torque curr lim Pos and the active
negative torque limit is Torque curr lim Neg.
2 – If the motor speed is < -1% of Rated speed the active positive torque limit is Torque curr lim Neg and the active
negative torque limit is Torque curr lim Pos.
3– If -1% of Motor non speed < motor speed < + 1% of Rated speed the active positive torque limit is Torque curr lim
Pos and the active negative torque limit is Torque curr lim Neg

If set to 3 the torque limits are symmetrical. The torque reference is the value of Torque curr lim Pos. This mode is not
managed with SSC control mode.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.4 2358 Torque limit src LINK 16/32BIT 3726 0 16384 ERWZ F_S
Selection of the origin (source) of the signal to be used for the torque current limit. The signals that can be associated with
the function are listed in the “L_LIM” selection list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.5 2360 Torque climPos Inuse A FLOAT 16/32BIT 0.0 0.0 0.0 ER FVS
The positive torque limit value currently being used is displayed.

VDL200 • Functions description and parameters list 67


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.6 2362 Torque climNeg Inuse A FLOAT 16/32BIT 0.0 0.0 0.0 ER FVS
The negative torque limit value currently being used is displayed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.7 2380 Dig torque ref 1 perc FLOAT 16/32BIT 0.0 -300.0 300.0 ERW FVS
Setting of a digital torque reference. The current reference value is proportional to the active motor current and determines
the torque value. The sign determines the torque direction.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.8 2382 Torque ref 1 src LINK 16/32BIT 3104 0 16384 ERWZ F_S
Selection of the origin (source) of the signal to be used for the torque reference. The signals that can be associated with
the function are listed in the “L_VREF” selection list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.9 2384 Torque ref filter ms FLOAT 1.0 0.1 10.0 ERW F_S
Setting of a filter on the torque reference.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

18.10 2386 Torque ref perc FLOAT 16/32BIT 0.0 0.0 0.0 ER F_S
The value of the torque reference is displayed.

68 VDL200 • Functions description and parameters list


19 - VF PARAMETERS
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.1 2400 Voltage flux boost perc FLOAT CALCF 0.0 15.0 RWS _V_
Fixed voltage boost level. Value defined during self-tuning.
The motor flux level is controlled in vector mode. For pure V/f control, set this parameter to zero.
Increase the value slightly in case of low torque at low speed.
Increase the value slightly in case of high current with motor saturation or very long motor cables.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.2 2402 Voltage boost gain V/A FLOAT CALCF 0.0 0.0 ERWS _V_
Setting of the boost flux magnetising current regulator gain.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.3 2404 Voltage torque boost ENUM Enable 0 1 ERWZ _V_


Enables vector torque compensation. For pure V/f control, disable this parameter.
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.4 2406 Vf voltage V FLOAT CALCF 10.0 690.0 ERWZS _V_


Setting of the maximum voltage value to be applied at the motor terminals (usually set according to the motor data plate).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.5 2408 Vf frequency Hz FLOAT CALCF 10.0 2000.0 ERWZS _V_


Setting of the motor rated frequency (indicated on the motor data plate)
This is the frequency at which the drive output voltage reaches the maximum output voltage (Vf voltage) on the motor.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.6 2410 Vf voltage 1 V FLOAT CALCF CALCF CALCF ERWZS _V_


Setting of an intermediate voltage value for the custom V/f characteristic curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.7 2412 Vf frequency 1 Hz FLOAT CALCF 0.0 CALCF ERWZS _V_


Setting of an intermediate frequency value for the custom V/f characteristic curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.8 2414 Vf voltage 0 V


FLOAT 0.0 0.0 CALCF ERWZS
_V_
Compensation of IR voltage drop at 0 Hz. This parameter must be increased in case of pure V/f control. The increase
depends on the size of the motor. Values that are too high could cause an overcurrent and motor saturation.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.9 2430 Vf shape ENUM Linear 0 1 ERWZS _V_


Selection of the type of V/f characteristic curve
0 Linear
1 Custom

V
Par.2406

Par.2408 Hz

VDL200 • Functions description and parameters list 69


Set 0 (Linear) to obtain a linear V/f characteristic curve, on which the intermediate points are reset to a value that is equal
to half those of parameters 2406 and 2408.
The Boost joins the curve automatically.

V
Par.2406

Par.2410
Par.2414
Par.2412 Par.2408 Hz
Set 1 (Custom) to obtain a customized V/f characteristic curve, in which the intermediate voltage and frequency values are
defined by parameters 2410 and 2412, as is the point at which the Boost joins the characteristic curve.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.10 2440 Slip comp Hz FLOAT CALCF 0.0 10.0 RWS _V_
Setting of the slip compensation. When the asynchronous motor is loaded, the mechanical speed of the motor shaft varies
according to the electric slippage, which affects torque generation. The slip compensation function can be used to maintain
a constant motor shaft speed. Compensation is performed by varying the drive output frequency as a function of its output
current and the motor parameters. Thus, to obtain the best effect, the motor plate data must be set appropriately, and the
correct stator resistance value (Par.2050) must be set or measured using the self-tuning function, The slip compensation
value is calculated automatically during the self-tuning procedure or set manually in this parameter.
During slip compensation tuning the drive must not be in the current limit condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.11 2442 Slip comp filter ms UINT16 200 50 5000 ERW _V_
Setting of the slip compensation filter. The value set in this parameter determines the slip compensation function reaction
time. The lower this parameter is set, the greater the slip compensation reaction. If this parameter is too low, it could cause
undesirable oscillations in speed after sudden variations to the applied load.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.12 2444 Slip comp mode ENUM Open loop lift 0 2 ERWZ _V_
0 Open loop
1 Closed loop
2 Open loop lift
When set to 0 (Open loop) the slip compensation value is that set manually in parameter 5210 or calculated by the self-
tuning procedure.
If set to 1 (Closed loop) the slip compensation value is measured by the reading of the signals by a digital encoder keyed
to the motor shaft. The relative expansion card must be installed in the drive to acquire the encoder signals. For best
results increase the value of PAR 2440 by 5 times.
If set to 2 (lift open loop) the slip compensation value is that set for lift cycle operation.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.13 2446 Slip P gain perc FLOAT 1.0 0.0 100.0 ERWS _V_
Setting of the slip compensation proportional gain.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.14 2448 Slip I gain perc FLOAT 1.5 0.0 100.0 ERWS _V_
Setting of the slip compensation integral gain.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.15 2460 Vfcurrent lim P gain Hz/A FLOAT CALCF 0.0 1000.0 ERWS _V_
Setting of the proportional gain limit in SSC mode. This is calculated automatically if the self-tuning procedure is performed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.16 2462 Vfcurrent lim I time ms FLOAT CALCF 1.0 50.0 ERWS _V_

70 VDL200 • Functions description and parameters list


Setting of the proportional gain limit in SSC mode. This is calculated automatically if the self-tuning procedure is performed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.17 2470 Damping gain perc UINT16 0 0 100 ERW _V_


Setting of the damping gain. The parameter is used to eliminate any oscillations or faults in the drive output current, deriv-
ing from configurations capable of generating oscillations in the drive/cable/motor system. If oscillations occur, gradually
increase the value of this parameter, until they disappear.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.18 2472 Damping threshold 1 Hz INT16 20 5 100 ERW _V_


Setting of the first damping gain regulation threshold. These settings are usually effective for intermediate frequencies and
make it possible to limit motor oscillations.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.19 2474 Damping threshold 2 Hz INT16 30 5 100 ERW _V_


Setting of the second damping gain regulation threshold. These settings are usually effective for intermediate frequencies
and make it possible to limit motor oscillations.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.20 2480 Vf min frequency Hz FLOAT 0.5 0.2 5.0 ERW _V_
Setting of the minimum frequency in the SSC control mode. This represents the minimum output frequency, below which
frequency regulations are ineffective. It is not possible to go below this value, regardless of the reference that has been
set.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.21 2482 Vf min freq delay ms UINT16 800 0 5000 ERW _V_
Setting of the delay for the minimum frequency signal in the SSC control mode.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.22 2490 Dig Vf scale FLOAT 16/32BIT 1.0 0.0 1.0 ERWZ _V_
Setting of a digital multiplier factor for the drive output voltage in the SSC mode.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

19.23 2492 Vf scale src LINK 16/32BIT 2490 0 16384 ERW _V_
Selection of the origin (source) of the signal to be used to set a multiplier factor for the drive output voltage. The associable
functions are listed in the “ “L_VREF” selection list.

VDL200 • Functions description and parameters list 71


20 - FUNCTIONS
20.1 - FUNCTIONS/INERTIA COMP
An increase in the dynamic response of the speed regulator to a variation in the reference, can be modified by changing the current
value during the acceleration/deceleration phase, to counter the applied machine inertia.
These parameters are calculated by the speed loop autotuning procedure but can also be set manually by the user.

Nota ! This menu is not displayed if the lift application is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.1.1 3100 Inertia comp kgm2


FLOAT 0.0 0.0 100.0 ERWS
F_S
Total value of the inertia on the motor shaft in Kgm² identified during the self-tuning procedure. If known, this value can also
be set manually by the user.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.1.2 3102 Inertia comp filter ms UINT16 30 1 100 ERW F_S


Setting of a filter on the torque compensation. The filter reduces noise due to
speed differentiation in the inertia block.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.1.3 3104 Inertia comp mon perc


FLOAT
16/32BIT 0.0 0.0 0.0 ER
F_S
The value of inertia compensation on the function block output is displayed.

20.2 - FUNCTIONS/DC BRAKING


The drive is capable of managing a direct current injection phase. During this phase a braking torque is generated that can be used
to stop the motor or block the rotor.
The following characteristics can be configured:
- signal used to activate the direct current injection phase
- direct current injection phase activation mode
- delay between activation of request for DC braking and start of direct current injection
- duration of direct current injection phase
- intensity of injected direct current
This function is useful for:
- slowing the motor running at any speed to zero speed
- slowing a motor driven by the load before applying the start command
- keeping the rotor blocked at the end of a deceleration ramp following a stop command.
This function cannot be used for intermediate braking as the motor speed must be brought to zero.
During the direct current injection phase the kinetic energy of the motor is dissipated as heat in the motor.
The following parameters allow complete control of the function.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.2.1 3150 DC braking cmd src LINK 16BIT 3710 0 16384 ERW FVS
Selection of the origin (source) of the signal to be used for the DC braking command. The terminal or signal that can be
used for this function can be defined from among those available in the “L_DIGSEL2” selection list”.
0 DC braking command not enable
1 DC braking command enable
In default conditions the origin of the DC braking command signal is 0 .

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.2.2 3152 DC brake mode ENUM Spento 0 3 ERW FVS


This parameter can be used to configure the DC braking activation modes.
0 Off
1 At Stop

72 VDL200 • Functions description and parameters list


2 On Command
3 OnCmd & AtStop

DC Braking

ON COMMAND
DC braking cmd src

DC braking cmd src


PAR 3150

DC brake delay Output current


PAR 3154

DC brake
DC brake current delay
PAR 3158

DC brake state

DC brake state
PAR 3160

DC brake mode
PAR 3152

AT STOP
Speed ref

Speed 0 ref thr

DC brake delay
PAR 3154 Output current DC brake
duration

DC brake duration DC brake


PAR 3156 delay DC brake
current

DC brake current DC brake state


PAR 3158

DC brake state
PAR 3160

DC brake mode
PAR 3152

In “Off” mode the direct current injection phase is never executed.

In “At stop” mode the direct current injection phase is executed when the stop command is sent and the speed reference
threshold = zero has been reached.

Example:
With the motor running at any speed, when the stop command is enabled the ramp output decreases according to the
selected ramp time, when the speed reference threshold = zero is reached PAR 934 Reference = 0 the direct current
injection phase is enabled. When the command is enabled after the delay configured in PAR 3154 DC brake delay direct
current injection starts. PAR 3156 DC brake time is used to configure the duration of the injection phase and PAR 3158
DC brake curr is used to configure the intensity of the injection phase current.

In “At command” mode the direct current injection phase is executed when the DC braking command configured using
parameter PAR 3150 DC braking command src is sent.
Example:
Motor running driven by load. When the drive is enabled and the DC braking command is sent the direct current injection
phase is activated. When the command is enabled after the delay configured in PAR 3154 DC brake delay direct current
injection starts. PAR 3156 DC brake time is used to configure the duration of the injection phase and PAR 3158 DC brake
curr is used to configure the intensity of the injection phase current.
If the command is an impulse shorter than the time programmed with PAR 3156 DC brake time, the direct current injection

VDL200 • Functions description and parameters list 73


phase continues at least for the time set in parameter DC brake time.
If the command is an impulse longer than the time programmed with 3156 DC brake time, the direct current injection
phase continues for as long as the command is present.

In “OnCmd & AtStop” modes the direct current injection phase is executed when one of the two conditions described in
the “At stop” or “On command” modes is present

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.2.3 3154 DC brake delay s FLOAT 0.0 0.00 30.0 ERW FVS
This parameter is used to configure the delay in seconds between the moment DC braking is requested and the moment
direct current injection starts.
This delay enables the motor to demagnetize, and thus avoid an overcurrent due to the electromotive force of the motor
(e.f.m.).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.2.4 3156 DC brake duration s FLOAT 1.0 0.01 30.0 ERW FVS
This parameter is used to configure the duration of direct current injection in the stator windings.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.2.5 3158 DC brake current perc FLOAT 75.0 0.0 150.0 ERW FVS
This parameter is used to configure the value of the injected direct current.
This is expressed as a percentage of the rated current of the motor at full load (par. 488 Drive cont current).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.2.6 3160 DC brake state ENUM 16BIT Non attivo 0 1 ER FVS


The status of direct current braking is displayed.
0 Not active
1 Active

Note! During braking the Enable command must be enabled. If this command is not present or is removed during the braking process, the drive
blocks the inverter bridge and the motor stops due to inertia, without braking.
During the direct current injection phase the Run command should not be enabled. If the Run command is sent to the drive, the ramp output
starts following the set reference; direct current output is produced in any case. The moment the DC braking command is removed there is
immediately a speed step without performing a change in the ramp.
During the direct current injection phase, for the Jog command follow the instructions provided for the Run command.

20.3 - FUNCTIONS/MOTOR OVERLOAD


The overload control function provides integrator logic to protect the motor against thermal overload. This protection presents the
characteristic I²t behaviour and is an emulation of the thermal relay of the motor controlled by the VDL200 drive.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.3.1 3200 Motor ovld enable


BIT 0 0 1 ERW
FVS
Enabling of the motor overload control.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.3.2 3202 Motor ovld factor perc


FLOAT 150.0 100.0 300.0 ERWS
FVS
Setting of the motor overload value. Percentage value of the motor rated current (par. 2002 Rated current).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.3.3 3204 Motor ovld time s FLOAT 30.0 10.0 300.0 ERWS
FVS
Setting of the motor overload duration in seconds. It represents the moment in which the protection (“Motor Overload”) is
enabled, if the motor current value is above the overload set in the Motor ovld factor parameter. This alarm can be as-
signed to a programmable digital output (Motor overload trip).

The trip time depends on the motor current value and is as follows:

74 VDL200 • Functions description and parameters list


Trip time [s]

Motor ovld factor

Rated current Motor current [%]


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.3.4 3206 Motor service factor perc FLOAT 100.0 25.0 200.0 ERWS FVS
Setting of the motor service factor. This is the difference between the peak current and rated current. It is used to calculate
the thermal image of the motor.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.3.5 3216 Motor fan type ENUM Servo fan 0 1 ERW FVS
This parameter is used to set the type of motor cooling system.

0 Auto fan
1 Servo fan

Auto fan indicates the presence of a fan unit mounted on the motor shaft that therefore turns at a speed proportional to the mo-
tor speed. Cooling is not very effective at low motor speeds.

Servo fan indicates the presence of an independent fan unit that therefore always runs at the rated speed. It ensures optimum
cooling efficiency at all motor speeds.
When the current motor speed is below (PAR 2004 Rated speed / 2) and PAR 3216 Motor fan type = Auto fan; , the MOTOR
OVERLOAD protection intervention time must be reduced as cooling is insufficient.

At below (PAR 2004 Rated speed / 2) the protection intervention time is reduced by reducing the direct current of the MOTOR
OVERLOAD function.
When the motor speed is equal to (PAR 2004 Rated speed / 2) the direct current of the MOTOR OVERLOAD function is equal
to PAR 2002 Rated current * PAR 3206 Motor service factor, , whereas below that limit it is modified following a linear pattern
until PAR 2002 Rated current * 3206 Motor service factor * PAR 3218 Motor derat factor when the motor speed reaches
zero.

The overload current of the MOTOR OVERLOAD function is obtained by PAR 2002 Rated current * 3206 Motor service factor
* PAR 3202 Motor ovld factor and is the maximum current that can circulate in the motor. If the MOTOR OVERLOAD function
is enabled the drive automatically sets the torque current limit so that Iout max. does not exceed this value.

With the MOTOR OVERLOAD function a current equal to the Overload level is supplied to the motor for the maximum time set
in PAR 3204 Motor ovld time, The slower the motor speed, the shorter the time allowed (see figure at beginning of chapter).

After the set time, the MOTOR OVERLOAD function automatically sets the torque current limit so that Iout max. does not exceed
the direct current of the MOTOR OVERLOAD function.
When the motor current speed exceeds (PAR 2004 Rated speed / 2) and PAR 3216 Motor fan type = Auto fan, the direct cur-
rent is not reduced as cooling is sufficient.
When PAR 3216 Motor fan type = Servo fan, the direct current is not reduced as cooling is sufficient.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.3.6 3218 Motor derat factor perc FLOAT 50.0 0.0 100.0 ERWS FVS
This parameter is used to set the derating factor. The value is expressed as a percentage of PAR 2002 Rated current *
PAR 3206 Motor service factor.

When the current motor speed is below (PAR 2004 Rated speed / 2) and PAR 3216 Motor fan type = Auto fan, the protec-
tion intervention time must be reduced as cooling is insufficient.
At below (PAR 2004 Rated speed / 2) sthe protection intervention time is reduced by reducing the direct current of the
MOTOR OVERLOAD function.

When the motor speed is equal to (PAR 2004 Rated speed / 2) ) the direct current of the MOTOR OVERLOAD function

VDL200 • Functions description and parameters list 75


is equal to PAR 2002 Rated current * PAR 3206 Motor service factor, whereas below that limit it is modified following a
linear pattern until PAR 2002 Rated current * PAR 3206 Motor service factor * PAR 3218 Motor derat factor when the
motor speed reaches zero.

The overload current of the MOTOR OVERLOAD function is obtained by PAR 2002 Rated current * PAR 3206 Motor
service factor * PAR 3202 Motor ovld factor and is the maximum current that can circulate in the motor. If the MOTOR
OVERLOAD function is enabled the drive automatically sets the torque current limit so that Iout max. does not exceed this
value.

With the MOTOR OVERLOAD function a current equal to the Overload level is supplied to the motor for the maximum time
set in PAR 3204 Motor ovld time, The slower the motor speed, the shorter the time allowed (see graphs).
After the set time, the MOTOR OVERLOAD function automatically sets the torque current limit so that Iout max. does not
exceed the direct current of the MOTOR OVERLOAD function.

When the motor current speed exceeds (PAR 2004 Rated speed / 2) and PAR 3216 Motor fan type = Auto fan, the direct
current is not reduced as cooling is sufficient.
When PAR 3216 Motor fan type = Servo fan, the direct current is not reduced as cooling is sufficient.

If the value of parameter 3202 Motor ovld factor is 100 % the overload current of the Motor Overload function is equal
to the continuous current of the Motor Overload function. In this case the drive behaves as if the overload cycle has been
executed and so sets the torque current limit so that Iout max is not more than the continuous current, i.e. Rated current
(PAR 2002) * Motor service factor (PAR 3206) * Motor derat factor (PAR 3218).
We recommend setting parameter 3218 Motor derat factor to a value so that Rated current (PAR 2002) * Motor service
factor (PAR 3206) * Motor derat factor (PAR 3218) produces a result that is more than the motor magnetisation current.

20.4 - FUNCTIONS/BRES OVERLOAD


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.4.1 3250 Bres control


BIT 1 0 1 ERWZ
FVS
Enabling of the external braking resistance and relative overload control.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.4.2 3252 Bres value ohm FLOAT SIZE 7.0 1000.0 ERWS FVS
Setting of the ohm value of the external braking resistor

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.4.3 3254 Bres cont power kW FLOAT SIZE 0.1 100.0 ERWS FVS
Setting of the power that can be continuously dissipated by the external braking resistor.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.4.4 3256 Bres overload factor FLOAT SIZE 1.5 10.0 ERWS FVS
Setting of the external resistor overload factor.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.4.5 3258 Bres overload time s FLOAT SIZE 0.5 50.0 ERWS FVS
Setting of the intervention time of the external braking resistor overload.

76 VDL200 • Functions description and parameters list


20.5 - FUNCTIONS/DOUBLE PAR SET
Two independent sets of parameters can be stored in the VDL200 drive. These can be selected via the keypad or by using an
external command.
This makes it possible to change all the drive parameters quickly and automatically according to the various operating require-
ments. For example, two motors with different characteristics can be controlled alternately.
Lift application parameters are not included in the two sets of parameters. This makes it possible to switch between all drive
parameters in two separate groups, while having a single set of parameters for the application.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.5.1 3300 Par set enable ENUM Disable 0 1 ERW FVS


Enabling of management of two parameter sets
0 Disable
1 Enable
When set to 0 only one parameter set is managed (the one used as the default set).
If set to 1 two separate parameter sets can be configured. These can be selected using a command signal on a digital
input of the terminal strip.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.5.2 3302 Par set select src LINK 16BIT 6000 0 16384 ERWZ FVS
Selection of the origin (source) of the signal to be used to select the parameter set to be used. The terminal or digital com-
mand that can be associated with this function can be selected from among those available in the “L_DIGSEL2” selection
list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.5.3 3304 Par set select mon ENUM 16BIT Set 0 0 0 ER FVS
The parameter set currently in use is displayed.
0 Set 0
1 Set 1

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.5.4 3306 Par set 0 to 1 copy BIT 0 0 1 ERWZ FVS


Procedures for setting up and managing the double parameter set

Creating the second set:

This function copies parameter set 0 onto set 1. Before enabling management of the double parameter set, the first set
should be programmed with the correct values.

When the first set is ready, the second can be activated as follows:

1 Activate management of the double parameter set by enabling parameter 3300 Par set enable.
2 Copy set 0 onto set 1 using command 3306 Par set 0 to 1 copy.
This creates an initial parameter base in set 1 to which changes can be made.
Save the parameters.
3 Activate set 1 using parameter 3302 Par set select src.

VDL200 • Functions description and parameters list 77


To select set 1 manually, set this parameter to “One”.
Otherwise select the desired source.
4 Modify the parameters in set 1 as necessary.
5 Save the parameters.

You can change the set being used by changing the source selected in parameter 3302 Par set select src. This can only
be changed with the drive disabled.

When the double parameter set is active, the number of the set being used is shown next to the number of each parameter
on the keypad.

Modifying and saving parameters:

When the double parameter set is active, any parameters that need to be the same in the two sets must be modified in
each set separately.
Parameters are only saved in the set that is active at the time. To save both sets, you must first save one and then select
and save the other.

Note! Any changes to the parameters regarding the “parameter sets”, performed when enabled, will be lost at the next switching unless a Par set 0
to 1 copy command is sent.
To save data permanently (even when the drive is switched off), send the Save parameters command (DRIVE CONFIG menu).

20.6 - FUNCTIONS/SPEED CAPTURE

Note! This menu is not displayed if the lift application is enabled

20.7 - FUNCTIONS/COMPARE
This function allows the comparison among two signals or values.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.1 3650 Dig compare input 1 perc FLOAT 32BIT 0.0 -100.0 100.0 ERW FVS
Setting of the digital value of the first element of comparison.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.2 3652 Dig compare input 2 perc FLOAT 32BIT 0.0 -100.0 100.0 ERW FVS
Setting of the digital value of the second element of comparison.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.3 3660 Compare input 1 src LINK 32BIT 3650 0 16384 ERW FVS
Selection of the origin (source) of the signal to be used as the first term of comparison. The values that can be selected in
the compare function are listed in the “L_CMP” selection list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.4 3662 Compare input 2 src LINK 32BIT 3652 0 16384 ERW FVS
Selection of the origin (source) of the signal to be used as the second term of comparison. The values that can be selected
in the compare function are listed in the “L_CMP” selection list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.5 3670 Compare function ENUM Nessuna 0 8 ERW FVS


Setting of the compare function between Compare input 2 and Compare input 1 to enable Cmp output.
0 None
1 Inp1=Inp2
2 Inp1!=Inp2
3 Inp1<Inp2

78 VDL200 • Functions description and parameters list


4 Inp1>Inp2
5 |Inp1|=|Inp2|
6 |Inp1|!=|Inp2|
7 |Inp1|<|Inp2|
8 |Inp1|>|Inp2|
If set to 0 the comparator is not enabled
If set to 1 the comparator output is enabled when the value of Compare digital inp 1 is inside the window resulting from
the value of Compare digital inp 2 ± the tolerance set via the Comparator Window.
If set to 2 the comparator output is enabled when the value of Compare digital inp 1 is not inside the window resulting
from the value of Compare digital inp 2 ± the tolerance set via the Comparator Window.
If set to 3 the comparator output is enabled when Compare input 1 is less than Compare input 2.
If set to 4 the comparator output is enabled when Compare input 1 is greater than Compare input 2.
If set to 5 the comparator output is enabled when the value of Compare digital inp 1 is inside the window resulting from
the absolute value of Compare digital inp 2 ± the tolerance set via the Comparator Window.
If set to 6 the comparator output is enabled when the absolute value of Compare digital inp 1 is not inside the window
resulting from the absolute value of Compare digital inp 2 ± the tolerance set via the Comparator Window.
If set to 7 the comparator output is enabled when the absolute value of Compare digital inp 1 is less than the absolute
value of Compare digital inp 2.
If set to 8 the comparator output is enabled when the absolute value of Digital compar inp1 is more than the absolute
value of Digital compar in2.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.6 3672 Compare window perc FLOAT 0.0 0.0 100.0 ERW FVS
Setting of the tolerance window for comparing the Compare input 1 and Compare input 2 signals.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.7 3674 Compare delay s FLOAT 0.0 0.0 30.0 ERW FVS
Setting of the delay for signalling the result of the comparison.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.7.8 3676 Compare output BIT 16BIT 0 0 1 ER FVS


The status of the comparator output is displayed:
0 The result of the set comparison is negative
1 The result of the set comparison is positive

20.8 - FUNCTIONS/PADS
The general variables are used to exchange data between the various components of a Bus system. They are similar to the vari-
ables of a PLC. Pads can be used, for example, to send information from a fieldbus to an optional card. All Pads can be read and
written.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

20.8.1 3700 Lift enable


INT32
32BIT 0 0 0 ERW
FVS
20.8.2 3702 Run cont mon
INT32
32BIT 0 0 0 ERW
FVS
20.8.3 3704 Up cont mon
INT32
32BIT 0 0 0 ERW
FVS
20.8.4 3706 Down cont mon
INT32
32BIT 0 0 0 ERW
FVS
20.8.5 3708 Brake cont mon
INT32
32BIT 0 0 0 ERW
FVS
20.8.6 3710 Lift dc brake
INT32
32BIT 0 0 0 ERW
FVS
20.8.7 3712 Brake 2 mon
INT32
32BIT 0 0 0 ERW
FVS
20.8.8 3714 Door open mon
INT32
32BIT 0 0 0 ERW
FVS
20.8.9 3716 Lift start
INT32
32BIT 0 0 0 ERW
FVS
20.8.10 3718 Pad 10
INT32
32BIT 0 0 0 ERW
FVS
20.8.11 3720 Lift status word
INT32
32BIT 0 0 0 ERW
FVS
20.8.12 3722 Pad 12
INT32
32BIT 0 0 0 ERW
FVS
20.8.13 3724 Pad 13
INT32
32BIT 0 0 0 ERW
FVS
20.8.14 3726 Ramp down limit
INT32
32BIT 0 0 0 ERW
FVS
20.8.15 3728 PAD 15
INT32
32BIT 0 0 0 ERW
FVS

VDL200 • Functions description and parameters list 79


20.8.16 3730 Lift wdec input
INT32
32BIT 0 0 0 ERW
FVS
Setting of general, 32 Bit variables. PAD parameters can be used as supporting parameters to send values written by the
fieldbus, serial line, etc. to digital outputs.

80 VDL200 • Functions description and parameters list


21 - COMMUNICATION
21.1 - COMMUNICATION/RS232
The VDL200 drive is provided with a standard port (9 pole sub-D connector: XS) for connecting the RS232 serial line used for drive-
PC point-to-point communication (via the GF-eXpress configuration software).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

21.1.1 3800 Drive address


UINT16 1 1 255 ERW
FVS
Setting of the address to which the drive responds when connected to the RS232 serial line.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

21.1.2 3802 Serial baudrate ENUM 38400 0 2 ERW FVS


Setting of the RS232 serial communication speed (Baud Rate).
0 9600
1 19200
2 38400

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

21.1.3 3810 Serial parameter ENUM None,8,1 0 3 ERW FVS


Setting of the format of the RS232 serial line.
0 None,8,1
1 None,8,2
2 Even,8,1
3 Odd,8,1

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

21.1.4 3804 Serial protocol ENUM Modbus 0 1 ERW FVS


Setting of the serial communication protocol:
0 Modbus
1 Jbus
Setting to 0 selects the Modbus RTU (Remote Terminal Unit) serial communication protocol.
Setting to 1 selects the Jbus serial communication protocol. The Jbus protocol is functionally identical to the Modbus, ex-
cept for the different numbering of addresses: in the Modbus these start from zero (0000 = 1st address) while in the JBUS
they start from one (0001 = 1st address) and maintain this difference throughout numbering.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

21.1.5 3806 Serial delay ms


UINT16 0 0 1000 ERW
FVS
Setting of the minimum delay between the drive receiving the last byte and starting its response. This delay avoids conflicts
on the serial line when the RS232 interface that is used has not been pre-set for automatic Tx/Rx switching. The parameter
only concerns the use of the standard RS232 serial line.
Example: if the delay in Tx/Rx switching on the master is a maximum of 20ms, the Ser answer delay parameter must be
set to at least 20ms: 22ms

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

21.1.6 3808 Serial swap data


BIT 0 0 1 ERW
FVS
This parameter enables the exchange of the reading of the High and Low parts of the words for FLOAT type parameters
when using the Modbus protocol.

21.2 -
21.3 -
21.4 -
21.5 -
21.6 -

Note ! Those menues are not available.

VDL200 • Functions description and parameters list 81


22 - ALARM CONFIG
In the ALARM CONFIG menu the type of effect any alarm signals have on the drive is determined:

- The alarm status is saved


- How must the drive react to the alarm signal?
- Auto restart
- Alarm reset

For some alarms, behaviour can be configured separately for each signal, while for the others the Disable drive is executed. Indi-
vidual signals can also be sent to a programmable digital output.

Activity Ignore The alarm is not included in the list of alarms, it is not included in the alarm log, it is not
signalled on the digital outputs, no drive commands are modified.

Warning The alarm is included in the list of alarms, it is included in the alarm log, it is signalled on
the digital outputs, the First alarm information is updated, the Alarm enabled information
is updated, no drive commands are modified.

Disable Drive The alarm is included in the list of alarms, it is included in the alarm log, it is signalled on
the digital outputs, the First alarm information is updated, the Alarm enabled information
is updated, a command is sent to stop and disable the motor, which stops due to inertia.

Stop The alarm is included in the list of alarms, it is included in the alarm log, it is signalled
on the digital outputs, the First alarm information is updated, the Alarm enabled informa-
tion is updated, a Stop command is sent. When the zero speed is reached the drive is
disabled. If Ramp control mode is enabled, the drive moves to the zero speed with the
set ramp time; when the Speed delay 0 signal is activated the drive is disabled. If Speed
control mode is enabled, the drive moves to the zero speed with the maximum current
possible; when the Speed delay 0 signal is activated the drive is disabled. If Torque
control mode is enabled, the drive moves to the zero speed with the time set by the load;
when the Speed delay 0 signal is activated the drive is disabled.

Fast stop The alarm is included in the list of alarms, it is included in the alarm log, it is signalled on
the digital outputs, the First alarm information is updated, the Alarm enabled information
is updated, a Fast Stop command is sent. When the zero speed is reached the drive is
disabled. If Ramp control mode is enabled, the drive moves to the zero speed with the
set fast stop ramp time (deceleration time 3); when the Speed delay 0 signal is activated
the drive is disabled. If Speed control mode is enabled, the drive moves to the zero
speed with the maximum current possible; when the Speed delay 0 signal is activated
the drive is disabled. If Torque control mode is enabled, the drive moves to the zero
speed with the set load time; when the Speed delay 0 signal is activated the drive is
disabled.

n alarms with Activity = Ignore or Warning can be enabled at the same time.
If an alarm with Activity = Stop or Fast Stop is enabled and another alarm with an Activity other than Ignore or Warning is enabled,
the drive stops and is disabled.
Not all alarms allow the controlled stopping of the drive. The following table shows the possibility of setting the Activities for the
individual alarm signals.

Alarm Ignore Warning Disable drive Stop Fast stop

ExtFlt ü ü ü ü ü
Motor OT ü ü ü ü ü
Overspeed ü ü ü ü ü
SpdRefLoss ü ü ü ü ü
SpdFbkLoss ü ü ü ü ü
Drive ovld ü ü ü ü ü
Motor ovld ü ü ü ü ü

82 VDL200 • Functions description and parameters list


Alarm Ignore Warning Disable drive Stop Fast stop

Bres ovld ü ü ü ü ü
InAir ü ü ü ü ü
PhLoss ü ü ü ü ü
Opt Bus ü ü ü ü ü

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.1 4500 Fault reset src LINK 16BIT 6000 0 16384 RW FVS
Selection of the origin (source) of the signal to be used for the command to reset the drive after an alarm. The terminal that
can be used for this function can be selected from among those listed in the “L_DIGSEL2” selection list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.2 4502 ExtFlt src LINK 16BIT 6000 0 16384 RW FVS


Selection of the origin (source) of the signal to be used as the input for the drive external fault alarm ExtFlt. The terminal
that can be used for this function can be selected from among those listed in the “L_DIGSEL2” selection list.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.3 4504 ExtFlt activity ENUM Disable 0 4 RW FVS


Setting of the behaviour of the drive in the event of an external fault alarm ExtFlt. This alarm indicates the intervention of a
drive external protection.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.4 4506 ExtFlt restart ENUM Disable 0 1 RW FVS


Enabling of automatic restart after the external fault alarm ExtFlt
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.5 4508 ExtFlt restart time ms UINT16 1000 120 30000 RW FVS
Setting of the time within which the External Fault alarm must be reset in order to perform automatic restart.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.6 4510 ExtFlt holdoff ms


UINT16 0 0 10000 RW
FVS
Setting of the delay between the signalling of the external fault alarm ExtFlt and enabling of the alarm. If an alarm condi-
tion occurs, the drive will wait for the set time before blocking is enabled. If the alarm is removed within the set time, the
drive will not indicate any alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.7 4520 MotorOT src LINK 16BIT 6000 0 16384 RW FVS


Selection of the origin (source) of the signal to be used for the motor overtemperature alarm MotorOT. The terminal that
can be used for this function can be selected from among those listed in the “L_DIGSEL2” selection list”.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.8 4522 MotorOT activity ENUM Warning 0 4 RW FVS


Setting of the behaviour of the drive in case of a motor overtemperature alarm MotorOT. This alarm indicates that the mo-
tor temperature is too high.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

VDL200 • Functions description and parameters list 83


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.9 4524 MotorOT restart ENUM Disable 0 1 RW FVS


Enabling of automatic restart after the motor overtemperature alarm MotorOT.
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.10 4526 MotorOT restart time ms UINT16 1000 120 30000 RW FVS
Setting of the time within which the Motor Overtemperature alarm must be reset in order to perform automatic restart.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.11 4528 MotorOT holdoff ms UINT16 1000 0 30000 RW FVS


Setting of the delay between the signalling of the motor overtemperature alarm MotorOT and enabling of the alarm. If an
alarm condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set
time, the drive will not indicate any alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.12 4540 Overspeed threshold rpm INT16 INT32 CALCI 0 CALCI RW FVS
Setting of the threshold above which the overspeed alarm Overspeed is enabled.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.13 4542 Overspeed activity ENUM Disable 0 4 RW FVS


Setting of the behaviour of the drive in case of a motor overspeed alarm Overspeed. This alarm indicates that the motor
speed has exceeded the threshold set in the Speed ref top lim and Speed ref bottom lim parameters in the COM-
MANDS menu.

0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.14 4544 Overspeed holdoff ms


UINT16 0 0 5000 RW
FVS
Setting of the delay between the signalling of the motor overspeed alarm Overspeed and enabling of the alarm. If an alarm
condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set time,
the drive will not indicate any alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.15 4550 SpdRefLoss threshold rpm INT16 100 0 CALCI RW FVS


Setting of the threshold below which the speed reference loss alarm SpdRefLoss occurs .

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.16 4552 SpdRefLoss activity ENUM Warning 0 4 RW FVS


Setting of the behaviour of the drive in case of a speed reference loss alarm SpdRefLoss. This alarm indicates that the
difference between the speed regulator reference and the actual motor speed is more than 100 rpm.
This alarm must be disabled (= 0 Ignore) when parameter 2354 is set to a value other than zero.

0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.17 4554 SpdRefLoss holdoff ms UINT16 1000 0 10000 RW FVS


The delay between the Speed ref loss alarm condition signal and activation of the actual alarm. If an alarm condition oc-
curs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set time, the drive will
not indicate any alarm condition.

84 VDL200 • Functions description and parameters list


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.18 4560 SpdFbkLoss activity ENUM Disable 0 4 RW FVS


Drive behaviour in case of the Speed fbk loss alarm is displayed. This alarm indicates the loss of the encoder feedback
signals. Each type of encoder generates the Speed fbk loss alarm differently (incremental signal error, absolute signal
error, serial error).

0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

The causes of the Speed fbk loss alarm and the information acquired from the encoder are shown in the SpdFbkLoss
code parameter 2172.

Note! See menu 15.13 for further information.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.19 4562 SpdFbkLoss holdoff ms UINT16 200 0 10000 RW FVS


Setting of the delay between the signalling of the speed feedback loss alarm condition SpdFbkLoss and the enabling of
the alarm. If an alarm condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed
within the set time, the drive will not indicate any alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.20 4564 SpdFbkLoss threshold rpm INT16 100 5 CALCI RW FV_


If using incremental digital encoders in single-ended mode, this parameter sets the limit above which the drive executes
the action set with parameter 4560 SpdFbkLoss activity.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.21 4570 Drive ovld activity ENUM Ignore 0 4 ERW FVS


Setting of the behaviour of the drive in case of a drive overload alarm Drive ovld. This alarm indicates that the drive over-
load threshold has been reached.

0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.22 4572 Motor ovld activity ENUM Warning 0 4 ERW FVS


Setting of the behaviour of the drive in case of a motor overload alarm Motor ovld. This alarm indicates that the motor
overload threshold has been reached.

0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.23 4574 Bres ovld activity ENUM Disable 0 4 ERW FVS


Setting of the behaviour of the drive in case of a braking resistor overload alarm Bres ovld. This alarm indicates that the
braking resistor overload threshold has been reached.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

VDL200 • Functions description and parameters list 85


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.24 4582 HTsens restart ENUM Disable 0 1 ERW FVS


Enabling of automatic restart after the drive heatsink overtemperature alarm HTsens.
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.25 4584 HTsens restart time ms UINT16 20000 120 60000 ERW FVS
Setting of the time within which the HT sensor alarm must be reset in order to perform automatic restart.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.26 4600 InAir activity ENUM Stop 0 4 ERW FVS


Setting of the behaviour of the drive in case of an intake air overtemperature alarm InAir. This alarm indicates that the
temperature of the intake cooling air is too high.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.27 4602 InAir restart ENUM Disable 0 1 ERW FVS


Enabling of automatic restart after the intake air overtemperature alarm InAir.
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.28 4604 InAir restart time ms UINT16 1000 120 30000 ERW FVS
Setting of the time within which the Intakeair OT alarm must be reset in order to perform automatic restart.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.29 4606 InAir holdoff ms UINT16 10000 0 30000 ERW FVS


Setting of the delay between the signalling of the intake air overtemperature alarm InAir and enabling of the alarm. If an
alarm condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set
time, the drive will not indicate any alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.30 4610 Desat restart ENUM Disable 0 1 ERW FVS


Enabling of automatic restart after the desaturation alarm Desat. This alarm indicates a short circuit between the motor
phases or on the power bridge.
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.31 4612 Desat restart time ms


UINT16 2000 1000 10000 ERW
FVS
Setting of the time within which the Desaturation alarm must be reset in order to perform automatic restart. (Time with
alarm signal active + 1000 msec).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.32 4620 IOverC restart ENUM Disable 0 1 ERW FVS


Enabling of automatic restart after the drive Overcurrent alarm. This alarm indicates an overcurrent (or short circuit be-
tween phases or towards the ground).
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.33 4622 IOverC restart time ms


UINT16 2000 1000 10000 ERW
FVS

86 VDL200 • Functions description and parameters list


Setting of the time within which the Overcurrent alarm must be reset in order to perform automatic restart. (Time with
alarm signal active + 1000 msec).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.34 4630 OverV restart ENUM Disable 0 1 ERW FVS


Enabling of automatic restart after the Overvoltage alarm. This alarm indicates an overvoltage on the intermediate circuit
(DC link)
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.35 4632 OverV restart time ms


UINT16 2000 1000 10000 ERW
FVS
Setting of the time within which the Overvoltage alarm must be reset in order to perform automatic restart. (Time with
alarm signal active + 1000 msec).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.36 4640 UnderV restart ENUM Enable 0 1 ERW FVS


Enabling of automatic restart after the Undervoltage alarm. This alarm indicates an undervoltage on the intermediate
circuit (DC link).
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.37 4642 UnderV restart time ms UINT16 1000 120 10000 ERW FVS
Setting of the time within which the Undervoltage alarm must be reset in order to perform automatic restart. (Time with
alarm signal active + 100 msec).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.38 4650 UVRep attempts


UINT16 5 0 1000 ERW
FVS
Setting of the maximum number of attempts at automatic restart after the Undervoltage alarm before a Mult Undervolt-
age alarm is generated. If this parameter is set to 1000 an infinite number of attempts are available.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.39 4652 UVRep delay s UINT16 240 0 300 ERW FVS


Setting of the time within which, if no automatic restarts are executed after the Undervoltage alarm, the attempts counter
is reset. In this way the number of attempts set in Underv res attempts are still available.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.40 4660 PhLoss activity ENUM Disable 0 4 ERW FVS


Setting of the behaviour of the drive in case of a no phase alarm. This alarm indicates the absence of a drive power supply
phase.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.41 4662 PhLoss restart ENUM Disable 0 1 ERW FVS


Enabling of automatic restart after the no phase alarm.
0 Disable
1 Enable

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.42 4664 PhLoss restart time ms UINT16 1000 120 10000 ERW FVS
Setting of the time within which the Phase loss alarm must be reset in order to perform automatic restart. (Time with alarm
signal active + 100 msec).

VDL200 • Functions description and parameters list 87


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.43 4668 PhLoss output test ENUM Enable 0 2 ERWZ FVS


Enabling of the output phase loss test.
0 Disable
1 Enable
2 Powerup
If set to 0 the test is disable
If set to 1 the drive verifies the presence of all the output phases each time it receives the enable command.
If set to 2 the drive only verifies the presence of all the output phases the first time the enable command is sent after pow-
ering

Note! The motor brake must be closed while running this test!

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.44 4680 GroundFault thr perc FLOAT 10.0 0.0 150.0 ERWS FVS
Setting of the threshold for the ground short circuit alarm Ground Fault.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.45 4700 Alarm dig sel 1 ENUM No alarm 0 40 ERW FVS


22.46 4702 Alarm dig sel 2 ENUM No alarm 0 40 ERW FVS
22.47 4704 Alarm dig sel 3 ENUM No alarm 0 40 ERW FVS
22.48 4706 Alarm dig sel 4 ENUM No alarm 0 40 ERW FVS
Setting of the alarm signal to enable on a digital output. The digital output is selected using parameters Alm dig out mon
1÷4, which can be enabled in the L_DIGSEL1 selection list.

0 No alarm
1 Overvoltage
2 Undervoltage
3 Ground fault
4 Overcurrent
5 Desaturation
6 MultiUndervolt
7 MultiOvercurr
8 MultiDesat
9 Heatsink OT
10 HeatsinkS OTUT
11 Intakeair OT
12 Motor OT
13 Drive overload
14 Motor overload
15 Bres overload
16 Phaseloss
17 Not Used
18 Not Used
19 Not Used
20 Not Used
21 External fault
22 Speed fbk loss
23 Overspeed
24 Speed ref loss
25 Not Used
26 Power down
27 Phaseloss out
28 Not Used
29 Not Used
30 Not Used
31 Not Used
32 Not Used
33 Plc1 fault
34 Plc2 fault
35 Plc3 fault
36 Plc4 fault
37 Plc5 fault

88 VDL200 • Functions description and parameters list


38 Plc6 fault
39 Plc7 fault
40 Plc8 fault

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.49 4720 Alm autoreset time s


FLOAT 0.0 0.0 60.0 ERW
FVS
Setting of the time interval that must pass before executing an automatic reset.
If no alarms are enabled the drive is set to restart.
If some alarms are still enabled the drive is set to execute a new attempt at automatic reset.
At each attempted reset a counter increases. If the limit set in the Alm autoreset number parameter is reached the drive is
set to make no more attempts at reset and waits for a user reset.
The counter is set to zero when an automatic reset or user reset is performed and no alarms are enabled.
If the parameter is 0 the function is disabled.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

22.50 4722 Alm autoreset number UINT16 20 0 100 ERW FVS


Setting of the maximum number of attempted automatic resets.

VDL200 • Functions description and parameters list 89


23 - ALARM LOG

This is the menu in which the log of previous alarms is saved, with the time the alarm occurred (in relation to the Time drive power
on parameter). The alarms are displayed starting from the most recent (No. 1) up to the furthest back in time (No. 30). Up to 30
alarm signals can be displayed. The sub-code is used by service technicians to identify the specific type of alarm. Press the ▲ and
▼ keys to scroll the screen pages of the alarm log. The alarm log cannot be deleted.

Alarm number
1 PhaseLoss Alarm description
110:32 0000H
2 Undervoltage
110:25 0000H Sub-code

Time alarm
occurred

3 SpdFbkLoss
110:20 0000H
4 Overspeed
109:25 0000H

90 VDL200 • Functions description and parameters list


PARAMETERS ON SELECTION LISTS, BUT NOT DISPLAYED ON KEYPAD
This list reports the parameters that are not displayed in the keyboard while they are part of the selection lists. These parameters
can be used as SOURCE of the input signals for the function block. (Refer to section A – Programming).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 262 Motor speed nofilter rpm


INT16
16BIT 0 0 0 ER
FVS
This parameter indicates the unfiltered motor speed.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 362 Drive overload trip


BIT
16BIT 0 0 1 ER
FVS
This signal indicates that the drive is in the overload alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 366 Drive overload 80%


BIT
16BIT 0 0 1 ER
FVS
This signal indicates that the drive has reached 80% of the thermal image accumulator (drive overload).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 626 Ramp ref out mon rpm


INT16
16BIT 0 0 0 ER
FVS
This parameter displays the reference value output of the ramp remference function block.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 760 Ramp out mon rpm


INT16
16BIT 0 0 0 ER
FVS
This parameter displays the reference value output of the ramp function block.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 764 Ramp acc state


BIT
16BIT 0 0 1 ER
FVS
This signal indicates whether the acceleration ramp is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 766 Ramp dec state


BIT
16BIT 0 0 1 ER
FVS
This signal indicates whether the deceleration ramp is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 934 Ref is 0
BIT
16BIT 0 0 1 ER
FVS
This signal is active when the reference is below the limit set in parameter 930 Reference 0 threshold.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 936 Ref is 0 delay


BIT
16BIT 0 0 1 ER
FVS
This parameter is active when the reference is below the threshold set in parameter 930 Reference 0 threshold. The
signal is enabled after the delay set with parameter 932 Reference delay 0.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 944 Speed is 0
BIT
16BIT 0 0 1 ER
FVS
This parameter is active when the speed is below the threshold set in parameter 940 Speed 0 threshold.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 946 Speed is 0 delay


BIT
16BIT 0 0 1 ER
FVS
This signal is active when the reference is below the threshold set in parameter 940 Speed 0 threshold. The signal is
activated after the delay set in parameter 942 Speed 0 delay.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 1060 Sequencer status


UINT16
16BIT 0 0 0 ER
FVS

VDL200 • Functions description and parameters list 91


This signal indicates the state of the “machine states” that controls drive operation.
STS_INIT 0
STS_MAGN 1
STS_STOP 2
STS_START 3
STS_FS_STOP 4
STS_FS_START 5
STS_QSTOP 6
STS_FS_MAGN 7
STS_W_QSTOP 8
STS_READY 9
STS_MAGN_START 10
STS_ALM_DISABLED 11
STS_ALM_END_ACTION 12
STS_ALM_STOP 13
STS_ALM_FSTOP 14
STS_ALM_R_TO_NORMAL 15
STS_READY_START 16
STS_READY_FSTOP 17
STS_ALM_NO_RESTART 18
STS_FS_MAGN_START 19

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 1062 Drive OK
BIT
16BIT 0 0 1 ER
FVS
This signal is active when the drive is in the “OK” condition and no alarms are present.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 1064 Drive ready


BIT
16BIT 0 0 1 ER
FVS
This signal is active when the drive reference is in the “Ready” to run condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 1110 Digital input E mon


BIT
16BIT 0 0 1 ER
FVS
These signals represent the state of the corresponding digital input.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 1210 Digital input 1X mon


BIT
16BIT 0 0 1 ER
FVS
- 1212 Digital input 2X mon
BIT
16BIT 0 0 1 ER
FVS
- 1214 Digital input 3X mon
BIT
16BIT 0 0 1 ER
FVS
- 1216 Digital input 4X mon
BIT
16BIT 0 0 1 ER
FVS
- 1218 Digital input 5X mon
BIT
16BIT 0 0 1 ER
FVS
- 1220 Digital input 6X mon
BIT
16BIT 0 0 1 ER
FVS
- 1222 Digital input 7X mon
BIT
16BIT 0 0 1 ER
FVS
- 1224 Digital input 8X mon
BIT
16BIT 0 0 1 ER
FVS
These signals represent the state of the corresponding digital input on the expansion card.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 2388 Torque ref nofilter perc


FLOAT
16BIT 0.0 0.0 0.0 ER
FVS
The torque control reference current without filter is displayed (in sensorless vector and field-oriented vector mode).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 3214 Motor overload trip


BIT
16BIT 0 0 1 ER
FVS
This signal is active when the drive is in the motor overload alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

92 VDL200 • Functions description and parameters list


- 3262 Bres overload trip
BIT
16BIT 0 0 1 ER
FVS
This signal is active when the drive is in the braking resistor overload alarm condition.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 4708 Alm dig out mon 1


BIT
16BIT 0 0 1 ER
FVS
This signal is activated when the alarm configured in parameter 4700 alarm dig sel 1 is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 4710 Alm dig out mon 2


BIT
16BIT 0 0 1 ER
FVS
This signal is activated when the alarm configured in parameter 4702 alarm dig sel 2 is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 4712 Alm dig out mon 3


BIT
16BIT 0 0 1 ER
FVS
This signal is activated when the alarm configured in parameter 4704 alarm dig sel 3 is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 4714 Alm dig out mon 4


BIT
16BIT 0 0 1 ER
FVS
This signal is activated when the alarm configured in parameter 4706 alarm dig sel 4 is active.

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 4770 First alarm


UINT32
16BIT 0 0 0 ERW
FVS
This parameter displays the first alarm to be activated.
0 No alarm
1 Overvoltage
2 Undervoltage
3 Ground fault
4 Overcurrent
5 Desaturation
6 MultiUndervolt
7 MultiOvercurr
8 MultiDesat
9 Heatsink OT
10 HeatsinkS OTUT
11 Intakeair OT
12 Motor OT
13 Drive overload
14 Motor overload
15 Bres overload
16 Phaseloss
17 Not Used
18 Not Used
19 Not Used
20 Not Used
21 External fault
22 Speed fbk loss
23 Overspeed
24 Speed ref loss
25 Not Used
26 Power down
27 Phaseloss out
28 Not Used
29 Not Used
30 Not Used
31 Not Used
32 Not Used
33 Plc1 fault
34 Plc2 fault
35 Plc3 fault
36 Plc4 fault
37 Plc5 fault
38 Plc6 fault
39 Plc7 fault
40 Plc8 fault

VDL200 • Functions description and parameters list 93


Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 4780 Alarm PLC


UINT16 0 0 0 ER
FVS
This parameter displays the state of the alarms generated by the application written with the internal PLC.
Bit Description
0 1 = PLC 1 fault active
1 1 = PLC 2 fault active
2 1 = PLC 3 fault active
3 1 = PLC 4 fault active
4 1 = PLC 5 fault active
5 1 = PLC 6 fault active
6 1 = PLC 7 fault active
7 1 = PLC 8 fault active

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 6000 Null
UINT32
32BIT 0 0 0 ER
FVS
This signal forces the variable to the zero level (always disabled).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 6002 One
UINT32
32BIT 1 1 1 ER
FVS
This signal forces the variable to level one (always active).

Menu PAR Description UM Type FB BIT Def Min Max Acc Mod

- 6006 Current limit state


BIT
16BIT 0 0 1 ER
FVS
This signal is activated when the drive is in the current limit condition.

94 VDL200 • Functions description and parameters list


C - SELECTION LISTS

PAR Description Menu PAR Description Menu PAR Description Menu

L_CMP 1068
1070
Start state mon
FastStop state mon
1.17
1.18
XXXX
6000
(2)

Null (*)
XXXX (1) 1024 Enable cmd mon 9.9 1218 Digital input 5X mon (*)
626 Ramp ref out mon (*) 1026 Start cmd mon 9.10 1220 Digital input 6X mon (*)
760 Ramp out mon (*) 1028 FastStop cmd mon 9.11 1222 Digital input 7X mon (*)
664 Speed setpoint 1.5 4708 Alm dig out mon 1 (*) 1224 Digital input 8X mon (*)
260 Motor speed 1.6 4710 Alm dig out mon 2 (*) 1062 Drive OK (*)
262 Motor speed nofilter (*) 4712 Alm dig out mon 3 (*) 1064 Drive ready (*)
2150 Encoder speed 15.11 4714 Alm dig out mon 4 (*) 934 Ref is 0 (*)
250 Output current 1.1 362 Drive overload trip (*) 936 Ref is 0 delay (*)
252 Output voltage 1.2 3214 Motor overload trip (*) 944 Speed is 0 (*)
254 Output frequency 1.3 3262 Bres overload trip (*) 946 Speed is 0 delay (*)
280 Torque current ref 1.9 366 Drive overload 80% (*) 1066 Enable state mon 1.16
282 Magnet current ref 1.10 3700 Lift enable 20.8.1 1068 Start state mon 1.17
284 Torque current 1.11 3702 Run cont mon 20.8.2 1070 FastStop state mon 1.18
286 Magnet current 1.12 3704 Up cont mon 20.8.3 1024 Enable cmd mon 9.9
2386 Torque ref 18.10 3706 Down cont mon 20.8.4 1026 Start cmd mon 9.10
2388 Torque ref nofilter (*) 3708 Brake cont mon 20.8.5 1028 FastStop cmd mon 9.11
270 DC link voltage 1.7 3710 Lift dc brake 20.8.6 4708 Alm dig out mon 1 (*)
1600 Analog input 1X mon 12.1 3712 Brake 2 mon 20.8.7 4710 Alm dig out mon 2 (*)
368 Drive overload accum 1.14 3714 Door open mon 20.8.8 4712 Alm dig out mon 3 (*)
3212 Motor overload accum 1.13 3716 Lift start 20.8.9 4714 Alm dig out mon 4 (*)
3260 Bres overload accum 1.15 3718 Pad 10 20.8.10 362 Drive overload trip (*)
3700 Lift enable 20.8.1 3720 Lift status word 20.8.11 3214 Motor overload trip (*)
3702 Run cont mon 20.8.2 3722 Pad 12 20.8.12 3262 Bres overload trip (*)
3704 Up cont mon 20.8.3 3724 Pad 13 20.8.13 366 Drive overload 80% (*)
3706 Down cont mon 20.8.4 3726 Ramp down limit 20.8.14 3700 Lift enable 20.8.1
3708 Brake cont mon 20.8.5 3728 PAD 15 20.8.15 3702 Run cont mon 20.8.2
3710 Lift dc brake 20.8.6 3730 Lift wdec input 20.8.16 3704 Up cont mon 20.8.3
3712 Brake 2 mon 20.8.7 6006 Current limit state (*) 3706 Down cont mon 20.8.4
3714 Door open mon 20.8.8 764 Ramp acc state (*) 3708 Brake cont mon 20.8.5
3716 Lift start 20.8.9 766 Ramp dec state (*) 3710 Lift dc brake 20.8.6
3718 Pad 10 20.8.10 4780 Alarm PLC (*) 3712 Brake 2 mon 20.8.7
3720 Lift status word 20.8.11 3676 Compare output 20.7.8 3714 Door open mon 20.8.8
3722 Pad 12 20.8.12 3716 Lift start 20.8.9
3718 Pad 10 20.8.10
3724
3726
Pad 13
Ramp down limit
20.8.13
20.8.14
L_DIGSEL2 3720 Lift status word 20.8.11
3728 PAD 15 20.8.15 3722 Pad 12 20.8.12
6000 Null (*) 3724 Pad 13 20.8.13
3730 Lift wdec input 20.8.16 6002 One (*) 3726 Ramp down limit 20.8.14
(1)
the XXXX parameter changes according 1110 Digital input E mon (*) 3728 PAD 15 20.8.15
to the src parameter used: 1210 Digital input 1X mon (*) 3730 Lift wdec input 20.8.16
1212 Digital input 2X mon (*) 6006 Current limit state (*)
3660 Compare input 1 src 1214 Digital input 3X mon (*)
= 3650 Dig compare input 1
(1)
20.7.1 764 Ramp acc state (*)
1216 Digital input 4X mon (*) 766 Ramp dec state (*)
3662 Compare input 2 src 1218 Digital input 5X mon (*) 4780 Alarm PLC (*)
= 3652 Dig compare input 2
(1)
20.7.2 1220 Digital input 6X mon (*) 3676 Compare output 20.7.8
1222 Digital input 7X mon (*)
1224 Digital input 8X mon (*) (2)
the XXXX parameter changes according
L_DIGSEL1 3700 Lift enable 20.8.1 to the src parameter used:
3702 Run cont mon 20.8.2
6000 Null (*) 3704 Up cont mon 20.8.3 1014 Local/remote src
6002 One (*) 3706 Down cont mon 20.8.4 = 1012 Dig local/remote
(2)
(*)
1110 Digital input E mon (*) 3708 Brake cont mon 20.8.5
1210 Digital input 1X mon (*) 3710 Lift dc brake 20.8.6
1212 Digital input 2X mon (*) 3712 Brake 2 mon 20.8.7 L_LIM
1214 Digital input 3X mon (*) 3714 Door open mon 20.8.8
1216 Digital input 4X mon (*) 3716 Lift start 20.8.9 6000 Null (*)
1218 Digital input 5X mon (*) 3718 Pad 10 20.8.10 1600 Analog input 1X mon 12.1
1220 Digital input 6X mon (*) 3720 Lift status word 20.8.11 3700 Lift enable 20.8.1
1222 Digital input 7X mon (*) 3722 Pad 12 20.8.12 3702 Run cont mon 20.8.2
1224 Digital input 8X mon (*) 3724 Pad 13 20.8.13 3704 Up cont mon 20.8.3
1062 Drive OK (*) 3726 Ramp down limit 20.8.14 3706 Down cont mon 20.8.4
1064 Drive ready (*) 3728 PAD 15 20.8.15 3708 Brake cont mon 20.8.5
934 Ref is 0 (*) 3730 Lift wdec input 20.8.16 3710 Lift dc brake 20.8.6
936 Ref is 0 delay (*) 3676 Compare output 20.7.8 3712 Brake 2 mon 20.8.7
944 Speed is 0 (*) 3714 Door open mon 20.8.8
946 Speed is 0 delay (*) 3716 Lift start 20.8.9
1066 Enable state mon 1.16 L_DIGSEL3
VDL200 • Selection lists 95
PAR Description Menu PAR Description Menu PAR Description Menu

3718 Pad 10 20.8.10


3720 Lift status word 20.8.11
3722 Pad 12 20.8.12
3724 Pad 13 20.8.13
3726 Ramp down limit 20.8.14
3728 PAD 15 20.8.15
3730 Lift wdec input 20.8.16
5008 Test gen out 24.1.5

L_SCOPE
6000 Null (*)

L_WDECOMP
6000 Null (*)
6002 One (*)
3700 Lift enable 20.8.1
3702 Run cont mon 20.8.2
3704 Up cont mon 20.8.3
3706 Down cont mon 20.8.4
3708 Brake cont mon 20.8.5
3710 Lift dc brake 20.8.6
3712 Brake 2 mon 20.8.7
3714 Door open mon 20.8.8
3716 Lift start 20.8.9
3718 Pad 10 20.8.10
3720 Lift status word 20.8.11
3722 Pad 12 20.8.12
3724 Pad 13 20.8.13
3726 Ramp down limit 20.8.14
3728 PAD 15 20.8.15
3730 Lift wdec input 20.8.16

(*) Parameter not shown on the


keypad. For information see
the “PARAMETERS INCLUDED
IN SELECTION LISTS BUT NOT
SHOWN ON THE KEYPAD” sec-
tion.

96 VDL200 • Selection lists


D - Block Diagrams

System diagram index

Drive overview (DrvOverview)

VDL200 • Block Diagrams 97


ADL1 application index (ADL1FuncIndex)

98 VDL200 • Block Diagrams


VDL200 • Block Diagrams 99
100 VDL200 • Block Diagrams
Expansion card digital inputs (DigImpExp)

Expansion card digital outputs (DigOutExp)

VDL200 • Block Diagrams 101


Analog inputs

Encoder config

102 VDL200 • Block Diagrams


SLS control (ControlVf)

VDL200 • Block Diagrams 103


Functions

104 VDL200 • Block Diagrams


VDL200 • Block Diagrams 105
106 VDL200 • Block Diagrams
Torque control (TorqueCtrl)

VDL200 • Block Diagrams 107


Gains adaptive (GainAdapt)

108 VDL200 • Appendix


VDL200 • Appendix 109
Gefran worldwide
GEFRAN DEUTSCHLAND GMBH GEFRAN BENELUX NV GEFRAN SIEI - ASIA
Philipp-Reis-Straße 9a ENA 23 Zone 3, nr. 3910 31 Ubi Road 1
D-63500 Seligenstadt Lammerdries-Zuid 14A #02-07, Aztech Building,
Ph. +49 (0) 61828090 B-2250 OLEN Singapore 408694
Fax +49 (0) 6182809222 Ph. +32 (0) 14248181 Ph. +65 6 8418300
[email protected] Fax +32 (0) 14248180 Fax +65 6 7428300
[email protected] [email protected]

SIEI AREG - GERMANY GEFRAN UK LTD GEFRAN INDIA


Gottlieb-Daimler Strasse 17/3 Clarendon Court Survey No. 191/A/1,
D-74385 - Pleidelsheim Winwick Quay Chinchwad Station Road,
Ph. +49 (0) 7144 897360 Warrington Chinchwad,
Fax +49 (0) 7144 8973697 WA2 8QP Pune-411033, Maharashtra
[email protected] Ph. +44 (0) 8452 604555 Ph. +91 20 6614 6500
Fax +44 (0) 8452 604556 Fax +91 20 6614 6501
[email protected] [email protected]

SENSORMATE AG GEFRAN MIDDLE EAST ELEKTRIK VE GEFRAN INC.


Steigweg 8, ELEKTRONIK SAN. VE TIC. LTD. STI 8 Lowell Avenue
CH-8355 Aadorf, Switzerland Yesilkoy Mah. Ataturk WINCHESTER - MA 01890
Ph. +41(0)52-2421818 Cad. No: 12/1 B1 Blok K:12 Toll Free 1-888-888-4474
Fax +41(0)52-3661884 D: 389 Bakirkoy /Istanbul Fax +1 (781) 7291468
http://www.sensormate.ch TURKIYE [email protected]
Ph. +90212 465 91 21
Fax +90212 465 91 22

GEFRAN FRANCE SA GEFRAN SIEI GEFRAN BRASIL


PARC TECHNOLAND Drives Technology Co., Ltd ELETROELETRôNICA
Bâtiment K - ZI Champ Dolin No. 1285, Beihe Road, Jiading Avenida Dr. Altino Arantes,
3 Allée des Abruzzes District, Shanghai, China 201807 377 Vila Clementino
69800 Saint-Priest Ph. +86 21 69169898 04042-032 SÂO PAULO - SP
Ph. +33 (0) 478770300 Fax +86 21 69169333 Ph. +55 (0) 1155851133
Fax +33 (0) 478770320 [email protected] Fax +55 (0) 1132974012
[email protected] [email protected]

GEFRAN S.p.A.
Manuale VDL200 ASY FP -EN
Via Sebina 74 GEFRAN DRIVES AND MOTION S.R.L Rev. 0.4 - 29-8-2018
25050 Provaglio d’Iseo (BS) ITALY Via Carducci 24 Technical Assistance :
[email protected]
Ph. +39 030 98881 21040 Gerenzano [VA] ITALY
Fax +39 030 9839063 Ph. +39 02 967601 Customer Service :
[email protected]
[email protected] Fax +39 02 9682653 Ph. +39 02 96760500
www.gefran.com [email protected] Fax +39 02 96760278