0% found this document useful (0 votes)
829 views37 pages

Everest Product Specification Manual

The document is a specification manual that provides details on ceiling and wall solutions. It includes specifications for several types of false ceiling systems using different grid frameworks and materials. The false ceiling systems are specified using G.I. or Everest framework in various sizes, along with Everest fiber cement boards or pearl tiles. Wall solutions involving partitions made of double skin G.I. or Everest Rondo frameworks are also specified. Additional sections provide specifications for suspended ceilings, wall paneling, and solid wall panels.

Uploaded by

Vengatesh Hari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
829 views37 pages

Everest Product Specification Manual

The document is a specification manual that provides details on ceiling and wall solutions. It includes specifications for several types of false ceiling systems using different grid frameworks and materials. The false ceiling systems are specified using G.I. or Everest framework in various sizes, along with Everest fiber cement boards or pearl tiles. Wall solutions involving partitions made of double skin G.I. or Everest Rondo frameworks are also specified. Additional sections provide specifications for suspended ceilings, wall paneling, and solid wall panels.

Uploaded by

Vengatesh Hari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 37

SPECIFICATION MANUAL

1
Index

Topic Page No.


1. Ceiling Solution 03

• False Ceiling in Exposed Grid G.I. Framework (T-2430) 04-05


with Everest Designer Fiber Cement Boards (Ivory)

• False Ceiling in Exposed Grid G.I. Framework (T-2420) 06-07


with Everest Designer Fiber Cement Boards (Ivory)

• False Ceiling in Exposed Grid G.I. Framework (T-1510) 08-09


with Everest Designer Fiber Cement Boards (Ivory)

• False Ceiling in Exposed Grid G.I. Framework (T-2430) 10-11


with Everest Pearl Designer Ceiling Tiles

• False Ceiling in Exposed Grid G.I. Framework (T-2420) 12-13


with Everest Pearl Designer Ceiling Tiles

• False Ceiling in Exposed Grid G.I. Framework (T-1510) 14-15


with Everest Pearl Designer Ceiling Tiles

• False Ceiling in Exposed Grid G.I. Framework (T-1520) 16-17


with Everest Designer Fiber Cement Boards (Ivory)

• False Ceiling in Exposed Grid G.I. Framework (T-1520) 18-19


with Everest Pearl Designer Ceiling Tiles

2. M/F Suspended Ceiling 20

• M/F Suspended Ceiling Plain (Concrete Floor)


21-22

3. Wall Solution 23

• Partitions in double skin full height G.I. framework of thickness 62/88mm 24-25

• Partitions in double skin full height Everest Rondo framework of 26-27


thickness 67/80mm

• Partitions in double skin full height G.I. framework of thickness 28-29


62/84/68/90mm

• Partitions in double skin full height Everest Rondo framework of thickness 30-31
63/76/69/82mm

4. Wall Paneling 32

• Wall Paneling with G.I. Framework 33-34

5. Solid Wall Panel 35

• Partitions in Solid Wall Panels of thickness 50/75 mm 36-37

2
Specification Manual

Ceiling Solution

3
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Designer Fiber Cement Boards (Ivory)

Main Runner ‘T’ section of


size 24x38mm hot dipped
Wall angle 595x595mm Everest Designer galvanized steel body and
Fiber Cement Boards capped with precoated of
dipped galvanized steel and
Concrete slab 3.6mtr. Long.
Cross Runner ‘T’ section of
size 29x24mm hot dipped
galvanized steel body and
capped with precoated of
dipped galvanized steel and
1.2/0.6mtr. Long.
Main T
Perimeter wall angle of
Level clip hot dipped galvanized
steel angle body of size
Cross T 24x24mm and 3.05mtr.
long

Tile edge detail

Square edge

Cross T Cross T
Main T
1200mm 600mm Level clip Wood Screws

SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
4
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Designer Fiber Cement Boards (Ivory)

Bill Of Quantity (For 100 Sq.m.) (Grid Size-1200 mm x 600 mm)

Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 mts. 170 mts. 64 nos. 64 nos. 64 nos.

Bill Of Quantity (For 100 Sq.m.) (Grid Size-600 mm x 600 mm)

Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Everest 3600 mm 1200 mm 600 mm
Fibre
Cement
Boards
595 mm x
595 mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high visibility areas like:


• Offices
• Showrooms/Shopping Centers
• Recreational facilities
• Residences
• Hotels and resorts

5
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Designer Fiber Cement Boards (Ivory)

Main Runner ‘T’ section of


size 24x38 hot dipped
Wall angle 595x595mm Everest Designer galvanized steel body and
Fiber Cement Boards capped with precoated of
dipped galvanized steel and
Concrete slab 3.6mtr. Long.
Cross Runner ‘T’ section of
size 28x24mm hot dipped
galvanized steel body and
capped with precoated of
dipped galvanized steel and
1.2/0.6mtr. Long.
Main T
Perimeter wall angle of
Level clip hot dipped galvanized
steel angle body of size
Cross T 24x24mm and 3.05mtr.
long

Tile edge detail

Square edge

Cross T
Main T Cross T
600mm Level clip Wood Screws
1200mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
6
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Designer Fiber Cement Boards (Ivory)

Bill Of Quantity (For 100 Sq.m.) (Grid Size-1200 mm x 600 mm)

Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 mts. 170 mts. 64 nos. 64 nos. 64 nos.

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high visibility areas like:


• Offices
• Showrooms/Shopping Centers
• Recreational facilities
• Residences
• Hotels and resorts
7
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Designer Fiber Cement Boards (Ivory)

Main Runner ‘T’ section of


size 32x15mm hot dipped
Wall angle 595x595mm Everest Designer galvanized steel body and
Fiber Cement Boards capped with precoated of
dipped galvanized steel and
Concrete slab 3.6mtr. Long.
Cross Runner ‘T’ section of
size 32x15mm hot dipped
galvanized steel body and
capped with precoated of
dipped galvanized steel and
1.2/0.6mtr. Long.
Main T
Perimeter wall angle of
Level clip hot dipped galvanized
steel angle body of size
Cross T 14x20mm and 3.05mtr.
long

Tile edge detail

Narrow Reveal edge

Main T Cross T Cross T


Level clip Wood Screws
1200mm 600mm
SPECIFICATION

Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
8
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Designer Fiber Cement Boards (Ivory)

Bill Of Quantity (For 100 Sq.m.) (Grid Size-1200 mm x 600 mm)

Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 Mts. 170 mts. 64 nos. 64 nos. 64 nos.

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat RowlPlug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high visibility areas like:


• Offices
• Showrooms/Shopping Centers
• Recreational facilities
• Residences
• Hotels and resorts
9
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Pearl Designer Ceiling Tiles

Main Runner ‘T’ section of


size 24x38mm hot dipped
Wall angle 595x595mm Everest Pearl galvanized steel body and
Designer Ceiling Tiles capped with precoated of
dipped galvanized steel and
Concrete slab 3.6mtr. Long.
Cross Runner ‘T’ section of
size 29x24mm hot dipped
galvanized steel body and
capped with precoated of
dipped galvanized steel and
1.2/0.6mtr. Long.
Main T
Perimeter wall angle of
Level clip hot dipped galvanized
steel angle body of size
Cross T 24x24mm and 3.05mtr.
long

Tile edge detail

Square edge

Main T
Cross T Cross T
Level clip Wood Screws
1200mm 600mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 38 x 24 mm, cross tee
29 mm x 24 mm & wall angle 2 4mm x 24 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so10 as to
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Pearl Designer Ceiling Tiles

Bill Of Quantity (For 100 Sq.m.) (Grid Size.-.600 mm x 600.mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts, 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high humidity and projects requiring chemical resistance:


• Kitchens
• Residential Complexes
• Offices
• Retail Shops
• Hospitals
• Restaurants
• Toilets
• Laboratories

11
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Pearl Designer Ceiling Tiles

Main Runner ‘T’ section of


size 24x38mm hot dipped
Wall angle 595x595mm Everest Pearl galvanized steel body and
Designer Ceiling Tiles capped with precoated of
dipped galvanized steel and
Concrete slab 3.6mtr. Long.
Cross Runner ‘T’ section of
size 28x24mm hot dipped
galvanized steel body and
capped with precoated of
dipped galvanized steel and
1.2/0.6mtr. Long.
Main T
Perimeter wall angle of
Level clip hot dipped galvanized
steel angle body of size
Cross T 24x24mm and 3.05mtr.
long

Tile edge detail

Square edge

Cross T Cross T
Main T Level clip Wood Screws
1200mm 600mm

SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 38 x 24 mm, cross tee
28 mm x 24 mm & wall angle 24mm x 24 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to
12
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Pearl Designer Ceiling Tiles

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high humidity and projects requiring chemical resistance:


• Kitchens
• Residential Complexes
• Offices
• Retail Shops
• Hospitals
• Restaurants
• Toilets
• Laboratories

13
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Pearl Designer Ceiling Tiles

Main Runner ‘T’ section of


size 32x15mm hot dipped
Wall angle 595x595mm Everest Pearl galvanized steel body and
Designer Ceiling Tiles capped with precoated of
dipped galvanized steel and
Concrete slab 3.6mtr. Long.
Cross Runner ‘T’ section of
size 32x15mm hot dipped
galvanized steel body and
capped with precoated of
dipped galvanized steel and
1.2/0.6mtr. Long.
Main T
Perimeter wall angle of
Level clip hot dipped galvanized
steel angle body of size
Cross T 20x14mm and 3.05mtr.
long

Tile edge detail

Narrow Reveal edge

Cross T Cross T
Main T Level clip Wood Screws
1200mm 600mm

SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 32 x 15 mm, cross tee
32 mm x 15 mm & wall angle 20mm x 14 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to
14
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Pearl Designer Ceiling Tiles

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
FibreCeme 3600 mm 1200 mm 600 mm
nt Boards
595 mm x
595 mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high humidity and projects requiring chemical resistance:


• Kitchens
• Residential Complexes
• Offices
• Retail Shops
• Hospitals
• Restaurants
• Toilets
• Laboratories

15
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Designer Fiber Cement Boards (Ivory)

Main Runner ‘T’ section of


size 15x41mm made of pre
Wall angle 595x595mm Everest Designer painted galvanized stee and 3.6
Fiber Cement Boards mtr. Long.
Concrete slab
Cross Runner ‘T’ section of
size 15x41mm made of pre
painted galvanized steel
and 1.2/0.6mtr. Long.

Perimeter wall angle


Main T of hot dipped
galvanized steel angle
Level clip body of size 24x24mm
Cross T and 3.05mtr. long
Tile edge detail

Narrow Reveal Edge

Main T Cross T Cross T


1200mm 600mm Level clip

SPECIFICATION

Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.

16
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Designer Fiber Cement Boards (Ivory)

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 1200 mm x 600 mm)

Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 mts. 170 mts. 64 nos. 64 nos. 64 nos.

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high visibility areas like:


• Offices
• Showrooms/Shopping Centers
• Recreational facilities
• Residences
• Hotels and resorts
17
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Pearl Designer Ceiling Tiles

Main Runner ‘T’ section of


size 15x41mm made of pre
Wall angle 595x595mm Everest Pearl painted galvanized stee and 3.6
Designer Ceiling Tiles mtr. Long.
Concrete slab

Cross Runner ‘T’ section of


size 15x41mm made of pre
painted galvanized steel
and 1.2/0.6mtr. Long.

Main T Perimeter wall angle


Level clip
of hot dipped
galvanized steel angle
Cross T body of size 24x24mm
and 3.05mtr. long

Tile edge detail

Narrow Reveal Edge

Cross T
Cross T
Main T 600mm Level clip
1200mm

SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 32 x 15 mm, cross tee
32 mm x 15 mm & wall angle 20mm x 14 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to
18
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Pearl Designer Ceiling Tiles

Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)

Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.

Area of Application:

1. False ceiling in high humidity and projects requiring chemical resistance:


• Kitchens
• Residential Complexes
• Offices
• Retail Shops
• Hospitals
• Restaurants
• Toilets
• Laboratories

19
M/F Suspended Ceiling

20
M/F Suspended Ceiling Plain (Concrete Floor)
Ceiling section 0.55mm
Soffit cleat thick, 80mm wide having
two flanges 26mm & 36mm
placed at 457.5 mm centers

Ceiling angle
Intermediate channel
Perimeter 0.91mm thick 45mm wide
channel having two flanges of 15mm
Each placed at 1220mm c/c

Ceiling section 6mm Heavy Duty Intermediate Perimeter channel0.55mm


At 457.5mm c/c Fiber Cement Board Channel Thick 27mm wide, having
two flanges of 20mm &
30mm each
Perimeter
6mm Heavy Duty Fiber Cement Boards
channel Everest Fiber Cement
Screws 25mm for fixing
Soffit cleat board to ceiling section at
RCC or Concrete slab 230mm &150mm at
perimeter channel

27x37x25x1.6mm
Soffit cleat

Ceiling Angle

Ceiling section
At 457.5mm c/c

Intermediate Channel
at 1220mm c/c 25x10x0.55mm 38x12Ømm
Ceiling angle Rawl Plug

Everest Fiber
Ceiling section Intermediate Channel Perimeter Channel Cement Screws

SPECIFICATION
M/F Suspended ceiling, which includes perimeter channels of size 0.55mm thick (having one flange of
20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to
brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending
intermediate channels of size 45mm (0.9mm thick with two flanges of 15mm each) from the soffit at
1220mm centres with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with GI cleat
and steel expansion fasteners. Then Ceiling section of 0.55mm thickness having knurled web of
51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel
with the help of connecting clip and in direction perpendicular to the intermediate channel at 457.5mm
centres. Single layer of 6mm square/tapered edge Everest Heavy Duty Fibre Cement Boards (confirm
21
to IS 14862:2000) is then screw fixed to ceiling section with 25mm Everest Fibre Cement screws at
230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with
suitable attachment.
M/F Suspended Ceiling Plain (Concrete Floor)

Bill of Quantity (For 100 Sq.m) (For Jointless Finish)

Ceiling Perimete Intermediat Ceiling Connecti Soffit Wooden Fiber


Everest Section r e Channel Angle ng Clip Cleat Screw & Cement
Fibre Channel PVC Screws
Cement Fastners
Boards
1828 mm x
1220 mm
100 Sq.m. 230 mts. 40 mts. 84 mts. 64 nos. 184 nos. 64 mts. 64 Nos. 2850
Nos.

22
Everest Wall Solution

23
Partitions in Double Skin Full Height G.I. Framework of thickness 62/88 mm
Overall Thickness
62/88mm
Duty Rating: Severe
8mm thk. Everest Fiber Cement Board
Tested as per BS 5234
Part 2

STC Rating: 42 dB as per


IS:9901 (Part III)-1981 &
ISO:140 (Part III)-1995
Max. Height: Upto 3.0m
48/70mm Standard GI
Stud at 600mm c/c

50/72mm Standard GI Plan Standard GI Stud 0.55mm


Floor channel Thick, 48mm wide having
two flanges 34mm & 36mm
8mm Thk. Everest Fiber
Section placed at 600mm centers
Cement Board
Standard GI Floor & Ceiling
Paper Tape channel 0.55mm thick
Slot for services Jointing compound 50mm wide having two
First layer flanges of 32mm each
Jointing compound
second layer
Jointing compound Standard GI Horizontal
Third layer Runner 0.55mm Thick,
48mm wide having two
flanges 34mm & 36mm
48/70mm Standard GI
Stud at 600mm c/c
Everest Fiber Cement
Screws 25mm for fixing
Everest Fiber Cement board To metal stud at
50/72mm Standard GI Screws 300mm & 150mm At floor
Floor channel & ceiling channel

Everest Fiber
Standard GI Floor & Cement Screws
Standard GI metal stud Horizontal Runner
Ceiling Channel

SPECIFICATION
Providing and fixing, 62/88 mm thick partition using G.I sections, 8 mm thick (High Pressure Steam
Cured), Everest Fibre Cement Board (Plain/PRS (Primered, recessed and sealant coated)/Bevelled at
site), depending upon the type of finish required) conforming to IS 14862:2000, fixed on the
framework using 25 mm fully threaded self embedding type fibre cement screws @ 300 mm c/c on
either side of 48/70 mm studs (0.55 mm thick having one flange of 34 mm and another flange of 36
mm) made of G.I steel placed at 600 mm c/c in 50/72 mm floor and ceiling channel (0.55 mm thick
having equal flanges of 32 mm G.I steel) with joints staggered to avoid through joints, all complete as
per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
24
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height G.I. Framework of thickness 62/88 mm

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)

Track Horizont Stud Fiber Wooden Paper Elasto Jointing


Everest al Cement Screws Tape Compound
Fibre Runners Screws & PVC
Cement Fastners
Boards
2420 mm x
1220 mm
195.2 Sq.m. 80 mts. 80 mts. 166 2850 nos. 68 nos. 320 mts. 5.00 Kgs 110 Kg
mts.

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt height) (For groove Finish)

Track Horizontal Stud Fiber Wooden


Everest Runners Cement Screws &
Fibre Screws PVC
Cement Fastners
Boards 2420
mm x 1220
mm
195.2 Sq.m. 80 mts. 80 mts. 166 mts. 2850 nos. 68 nos.

Area of Application:

1. Internal walls (Half height/Full Height)


2. Pre fabricated structures – Internal/External Walls

25
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 67/80 mm
Overall Thickness
67/80mm

Duty rating: Severe


Tested as per BS 5234
Part 2

Everest Rondo Wall Stud


0.55mm Thick, 51/64mm
Wide having two flanges
34mm & 36mm placed at
600mm centers

Everest Rondo Floor &


Ceiling channel 0.55mm
Thick 51/64mm wide
having two flanges of
34mm each

Everest Rondo nogging


Channel 0.75mm thick
51/64mm wide, having two
flanges of 46mm each

Everest Fiber Cement


Screws 25mm for fixing
board To metal stud at
300mm & 150mm At floor
& ceiling channel

Everest Fiber
Everest Rondo metal Everest Rondo Floor Everest Rondo Nogging
Cement Screws
stud & Ceiling Channel Channel

SPECIFICATION
Providing and fixing, 67/80 mm thick partition using Rondo sections, 8 mm thick (High Pressure Steam
Cured), Plain / PRS (Primered, Recessed & Sealant Coated)/Bevelled at site) boards conforming to IS
14862:2000, fixed on the framework using 25 mm fully threaded self-embedding type Everest fibre
cement screws @ 300 mm c/c on either side of 51/64 mm studs (0.55 mm thick having one flange of
34 mm and another flange of 36 mm) made of Galvalume steel placed at 600 mm c/c in 51/64 mm
floor and ceiling channel (0.55 mm thick having equal flanges of 32 mm G.I steel) with joints
staggered to avoid through joints, all complete as per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
26
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 67/80 mm

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)

Everest Fibre Track Noggin Stud Fiber Wood Paper Elasto Jointing
Cement Boards gs Cemen en Tape Compound
2420 mm x t Screws
1220 mm Screws & PVC
Fastne
rs
195.2 Sq.m. 80 80m 166 2850 68 nos. 320 5.00 Kgs 110 Kg
mts. mts. nos. mts.
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)

Everest Track Nogging Stud Fiber Wooden


FibreCement s Cement Screws & PVC
Boards 2420 Screws Fastners
mm x 1220
mm
195.2 Sq.m. 80 mts. 80m 166 2850 nos. 68 nos.
mts.

Area of Application:

1. Internal walls (Half height/Full Height)


2. Pre fabricated structures – Internal/External Walls

27
Partitions in Double Skin Full Height G.I. Framework of thickness 62/84/68/90 mm
Overall Thickness
62/84/68/90mm

6/9mm Everest Heavy Duty Fiber Cement Boards Duty Rating: Severe
Tested as per BS 5234
Part 2

STC Rating: 42 dB as per


IS:9901 (Part III)-1981 &
ISO:140 (Part III)-1995
48/70mm Standard GI
Stud at 600mm c/c

50/72mm Standard GI Plan Standard GI Stud 0.55mm


Floor channel Thick, 48mm wide having
two flanges 34mm & 36mm
Section placed at 600mm centers
6/9mm Heavy Duty
Boards Standard GI Floor & Ceiling
Slot for services channel 0.55mm thick
Paper Tape
50mm wide having two
Jointing compound flanges of 32mm each
First layer
Jointing compound
second layer Standard GI Horizontal
Runner 0.55mm Thick,
Jointing compound
48mm wide having two
Third layer
flanges 34mm & 36mm
48/70mm Standard GI
Stud at 600mm c/c Everest Fiber Cement
Screws 25mm for fixing
Drywall Screws board To metal stud at
300mm & 150mm At floor
50/72mm Standard GI
& ceiling channel
Floor channel

Everest Fiber
Standard GI Floor & Standard GI Horizontal
Standard GI metal stud Cement Screws
Ceiling Channel Runner

SPECIFICATION
Providing and fixing, 62/84/68/90 mm thick partition using G.I sections, 6 mm /9 mm thick (High
Pressure Steam Cured), Everest Heavy Duty Fibre Cement Board conforming to IS 14862:2000, fixed
on the framework using 25 mm fully threaded self-embedding type fibre cement screws @ 300 mm c/c
on either side of 48/70 mm studs (0.55 mm thick having one flange of 34 mm and another flange of 36
mm) made of G.I steel placed at 600 m c/c in 50/72 mm floor and ceiling channel (0.55 mm thick
having equal flanges of 32 mm G.I steel) with joints staggered to avoid through joints, all complete as
per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
28
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height G.I. Framework of thickness 62/84/68/90 mm

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)
Everest Track Horizon Stud Fiber Wood Paper Elasto Jointing
Fibre tal Cement en Tape Compound
Cement Runner Screws Screw
Boards s&
2420 mm PVC
x 1220 Fastne
mm rs
195.2 80 80 mts. 166 2850 68 nos 320 6.00 Kgs 110 Kg
Sq.m. mts. mts. nos mts.

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)

Everest Track Horizont Stud Fiber Wooden


FibreCement al Runner Cement Screws & PVC
Boards 2420 Screws Fastners
mm x 1220
mm
195.2 Sqm 80 mts. 80 mts. 166 m 2850 68 nos.
nos.

Area of Application:

1. Internal walls (High traffic/Impact prone areas)


2. Wet area lining
3. External Walls (Non load bearing/Load bearing walls)
4. Cladding walls in warehouses/Factories
5. Pre fabricated structures (Internal/External walls)
29
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 63/76/69/82 mm

Overall Thickness
63/76/69/82mm

Duty rating: Severe


Tested as per BS 5234
Part 2

Everest Rondo Stud 0.55mm


Thick, 51/64mm wide
having two flanges 34mm
& 36mm placed at 600mm
centers

Everest Rondo Floor &


Ceiling channel 0.55mm
thick 50mm wide having
two flanges of 32mm each

Everest Rondo nogging


Channel 0.75mm thick
51/64mm wide, having two
flanges of 46mm each

Everest Fiber Cement


Screws 25mm for fixing
board To metal stud at
300mm & 150mm At floor
& ceiling channel

Everest Fiber
Everest Rondo metal Everest Rondo Floor Everest Rondo Nogging
Cement Screws
stud & Ceiling Channel Channel

SPECIFICATION
Providing and fixing, 63/76/69/82 mm thick partition using Rondo sections, 6 / 9 mm thick (High
Pressure Steam Cured), Everest Heavy Duty Fibre Cement Boards conforming to IS 14862:2000, fixed
on the framework using 25 mm fully threaded self -embedding type Everest fibre cement screws @ 300
mm c/c on either side of 51/64 mm studs (0.55 mm thick having one flange of 34 mm and another
flange of 36 mm) made of Galvalume steel placed at 600 mm c/c in 51/64 mm floor and ceiling
channel (0.55 mm thick having equal flanges of 32 mm G.I steel) with joints staggered to avoid
through joints, all complete as per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
30
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 63/76/69/82

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)

Track Noggin Stud Fiber Wooden Paper Elasto Jointing


Everest gs Cement Screws & Tape Compound
Fibre Screws PVC
Cement Fastners
Boards
2420 mm x
1220 mm
195.2 Sq.m. 80 mts. 80 166 2850 68 nos. 320 mts. 6.00 Kgs 110 Kg
mts. mts. nos.

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)

Track Nogging Stud Fiber Wooden


Everest s Cement Screws &
FibreCement Screws PVC
Boards 2420 mm x Fastners
1220 mm
195.2 Sq.m. 80 mts. 80 mts. 166 2850 nos. 68 nos.
mts.

Area of Application:

1. Internal walls (High traffic/Impact prone areas)


2. Wet area lining
3. External Walls (Non load bearing/Load bearing walls)
4. Cladding walls in warehouses/Factories
5. Pre fabricated structures (Internal/External walls)
31
Wall Panelling

32
Wall Panelling with G.I. Framework
Overall Thickness
32/34mm

Ceiling section 0.55mm


thick, 80mm wide having
two flanges 26mm placed
at 600 mm centers

Perimeter channel0.55mm
Thick 27mm wide, having
two flanges of 20mm &
30mm each

Everest Fiber Cement


Screws 25mm for fixing
board To metal stud at
300mm & 150mm At floor
& ceiling channel

Ceiling section Perimeter Channel Everest Screws


SPECIFICATION
Providing and fixing, in position concealed G.I section for panelling using 6mm/8mm thick (High
Pressure Steam Cured), pre-primered, self-embossed, desinger cement board of Lake & Hill/
Oceanic/Cascade/Electra texture or the non-primered, plain variant of Everest Fiber Cement Boards
conforming to IS 14862:2000 fixed on the supporting ‘W’ profile (0.55 mm thick having a knurled web
of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm) placed @ 600 mm c/c vertically
and 1200 mm c/c horizontally in perimeter channel (having one flange of 20 mm and another flange of
30 mm with thickness of 0.55 mm and web of length 27 mm). Perimeter channel is fixed on the floor
and the ceiling with the nylon sleeves @ 300 mm c/c with expandable fasteners. Board is fixed to the
‘W’ profile with 25 mm long self embedding type Everest fibre cement screws @ 300mm c/c, all
complete as per the drawing & directions of engineer-in-charge. The boards may be finished so as to
have a uniform gap/groove or flush finish. The flush finish should be done with Elasto prefab joint
sealant, Everest Internal Jointing Compound and paper tape as per the procedure laid down by the
company. Alternatively the uniform gap/groove may be covered with decorative molding or may be
33
finished with Jointing Filler.
Finally, if specified, the boards are to be painted with 2 coats of acrylic emulsion paint of approved
shade/make, over a coat of cement primer before installing it on the grid.
Wall Panelling with G.I. Framework

Bill of Quantity (For 100 Sq.m) (For 2.44 mt. height) (For Jointless Finish)

Perimeter Ceiling Horizonta Fibre Wooden Paper Elasto Jointing


Everest Section l Runner Cement Screws & Tape Compou
Fibre Screws PVC nd
Cement Fastners
Boards
2420 mm x
1220 mm
195.2 80 mts. 166 mts. 80 mts. 2850 nos. 68 nos. 320 mts. 2.50 Kgs 55 Kg
Sq.m.

Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)

Perimete Horizont Ceiling Fibre Wooden


Everest Fibre r al Runner Section Cement Screws &
Cement Screws PVC Fastners
Boards 2420
mm x 1220
mm
195.2 Sq.m. 80 mts. 80 mts. 166 mts. 2850 nos. 68 nos.

Area of Application:

1. Internal Wall Lining/paneling


2. Wall Lining – to cover damp/seepage prone wall

34
Solid Wall Panel

35
Partitions in Solid Wall Panels of thickness 50/75 mm
Overall Thickness
50 / 75 mm

Duty rating: Severe


Tested as per BS 5234
Part 2

Sound Insulation: 38 dB

Fire Rating: 134 Min


(75 mm)
108 Min (50 mm)

GI Ceiling channel 1.2 mm


thick having equal flanges
Of 25 mm and floor
channel 1.2 mm thick
having flanges of 14 &
25 mm

Wooden screw of 8 mm
dia and 35 mm length
along with PVC dash
fastners for fixing floor
and ceiling channels fixed
at 600 mm c/c.

Top & Bottom G.I. Channel 1.2 mm thick

SPECIFICATION
SPECIFICATIONS OF SWP :
Providing and fixing 50/75mm thick non asbestos Fibre reinforced aerated cement sandwich
modules made out of light weight fibre reinforced areated cement/ concrete core composed of
portland cement, flyash, binders etc., and 4mm thick non asbestos fibre cement borads confirming
to IS 14862;2000 and ISO : 8336:1993(E) on either side of the core, having a tongue and groove
on logitudinal side of the modules. These Panel modules are erected/ installed using galvanised
iron steel tracks of 1mm thick & of size 14x50x25mm as bottom track, 25x50x25mm as top track
36 for
for fixing to the floor and top of the wall respectively including all necessary material required
errecting & fixing the wall panel complete as per direction of Engineer-in-charge (for payment net
area of wall to be measured.). Finally, if specified, the SWP are to be painted with 2 coats of acrylic
emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Solid Wall Panels of thickness 50/75 mm

Bill of Quantity for 3mt x 3mt wall area

Everest G.I Track Wooden Screws & PVC Fibre Jointing


Solid Wall Fasteners Tape Compound
Panels

9 12 24 nos. 24 mts 2 kgs

Area of Application:

1. Internal Walls
2. Wet area Lining
3. External Walls
4. Cladding walls in warehouses/factories
5. Pre fabricated structure