Everest Product Specification Manual
Everest Product Specification Manual
1
Index
3. Wall Solution 23
• Partitions in double skin full height G.I. framework of thickness 62/88mm 24-25
• Partitions in double skin full height Everest Rondo framework of thickness 30-31
63/76/69/82mm
4. Wall Paneling 32
2
Specification Manual
Ceiling Solution
3
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Designer Fiber Cement Boards (Ivory)
Square edge
Cross T Cross T
Main T
1200mm 600mm Level clip Wood Screws
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
4
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Designer Fiber Cement Boards (Ivory)
Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 mts. 170 mts. 64 nos. 64 nos. 64 nos.
Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Everest 3600 mm 1200 mm 600 mm
Fibre
Cement
Boards
595 mm x
595 mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
5
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Designer Fiber Cement Boards (Ivory)
Square edge
Cross T
Main T Cross T
600mm Level clip Wood Screws
1200mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
6
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Designer Fiber Cement Boards (Ivory)
Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 mts. 170 mts. 64 nos. 64 nos. 64 nos.
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
8
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Designer Fiber Cement Boards (Ivory)
Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 Mts. 170 mts. 64 nos. 64 nos. 64 nos.
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat RowlPlug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
Square edge
Main T
Cross T Cross T
Level clip Wood Screws
1200mm 600mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 38 x 24 mm, cross tee
29 mm x 24 mm & wall angle 2 4mm x 24 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so10 as to
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2430) with Everest Pearl Designer Ceiling Tiles
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts, 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
11
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Pearl Designer Ceiling Tiles
Square edge
Cross T Cross T
Main T Level clip Wood Screws
1200mm 600mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 38 x 24 mm, cross tee
28 mm x 24 mm & wall angle 24mm x 24 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to
12
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-2420) with Everest Pearl Designer Ceiling Tiles
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
13
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Pearl Designer Ceiling Tiles
Cross T Cross T
Main T Level clip Wood Screws
1200mm 600mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 32 x 15 mm, cross tee
32 mm x 15 mm & wall angle 20mm x 14 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to
14
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-1510) with Everest Pearl Designer Ceiling Tiles
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
FibreCeme 3600 mm 1200 mm 600 mm
nt Boards
595 mm x
595 mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
15
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Designer Fiber Cement Boards (Ivory)
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling suspension system of grid size 600 mm x 600
mm/1200 mm x 600 mm with main runner 38 x 24 mm, cross tee 29 mm x 24 mm & wall angle 24 mm x 24 mm. Using 6 mm
thick (High Pressure Steam Cured), pre-painted, self-embossed, reinforced designer cement board (Ivory) of Lake &
Hill/Oceanic/Cascade/Electra texture, conforming to IS 14862:2000 , to be placed in a grid of G.I. system duly suspended with 4
mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron Purlins from the roof with adjustment clip providing positions
for light fixtures, air-conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural
soffit by hanger @1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450
mm from the adjacent wall. Flush fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to form
600 mm x 600 mm or 1200 mm x 600 mm grid. Provide provisions for light fixtures, air conditioning ducts and diffusers, fire
alarms, sprinklers or smoke detectors etc. as per the drawing and directions of engineer-in-charge.
16
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Designer Fiber Cement Boards (Ivory)
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 1200 mm x 600 mm)
Everest Fibre Wall Angle Main ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Cement 3600 mm 1200 mm
Boards 1195
mm x 595
mm
140 40 mts. 84 mts. 170 mts. 64 nos. 64 nos. 64 nos.
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts 64 nos. 64 nos. 64 nos.
Area of Application:
Cross T
Cross T
Main T 600mm Level clip
1200mm
SPECIFICATION
Providing and fixing, in position suspended false ceiling using G.I. exposed ceiling
suspension system of grid size 600 mm x 600 mm with main runner 32 x 15 mm, cross tee
32 mm x 15 mm & wall angle 20mm x 14 mm. Using 3.2 mm thick (High Pressure Steam
Cured), pre-painted, UV film coated, self-embossed, reinforced Heavy Duty fiber cement
board of Pearl texture variant conforming to IS 14862:2000, to be placed in a grid of G.I.
system duly suspended with 4 mm dia G.I/M.S bar hanger fixed with steel dash fasteners or
iron purlin from the roof with adjustment clip providing positions for light fixtures, air-
conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be
secured to structural soffit by hanger @1200 mm maximum c/c. The last hanger at the end
of each main runner should not be placed at more than 450 mm from the adjacent wall. Flush
fitting 1200 mm cross tee to be interlocked between main runners @600 mm c/c, so as to
18
form 600 mm x 600 mm grid. Provide provisions for light fixtures, air-conditioning ducts and
diffusers, fire alarms, sprinklers or smoke detectors etc. as per the drawing and directions of
engineer-in-charge.
False Ceiling in Exposed Grid G.I. Framework (T-1520) with Everest Pearl Designer Ceiling Tiles
Bill Of Quantity (For 100 Sq.m.) (Grid Size - 600 mm x 600 mm)
Everest Wall Angle Main ‘T’ Cross ‘T’ Cross ‘T’ Level Clip Soffit Cleat Rowl Plug
Fibre 3600 mm 1200 mm 600 mm
Cement
Boards 595
mm x 595
mm
282 nos. 40 mts. 84 mts. 170 mts. 86 mts. 64 nos. 64 nos. 64 nos.
Area of Application:
19
M/F Suspended Ceiling
20
M/F Suspended Ceiling Plain (Concrete Floor)
Ceiling section 0.55mm
Soffit cleat thick, 80mm wide having
two flanges 26mm & 36mm
placed at 457.5 mm centers
Ceiling angle
Intermediate channel
Perimeter 0.91mm thick 45mm wide
channel having two flanges of 15mm
Each placed at 1220mm c/c
27x37x25x1.6mm
Soffit cleat
Ceiling Angle
Ceiling section
At 457.5mm c/c
Intermediate Channel
at 1220mm c/c 25x10x0.55mm 38x12Ømm
Ceiling angle Rawl Plug
Everest Fiber
Ceiling section Intermediate Channel Perimeter Channel Cement Screws
SPECIFICATION
M/F Suspended ceiling, which includes perimeter channels of size 0.55mm thick (having one flange of
20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to
brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending
intermediate channels of size 45mm (0.9mm thick with two flanges of 15mm each) from the soffit at
1220mm centres with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with GI cleat
and steel expansion fasteners. Then Ceiling section of 0.55mm thickness having knurled web of
51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel
with the help of connecting clip and in direction perpendicular to the intermediate channel at 457.5mm
centres. Single layer of 6mm square/tapered edge Everest Heavy Duty Fibre Cement Boards (confirm
21
to IS 14862:2000) is then screw fixed to ceiling section with 25mm Everest Fibre Cement screws at
230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with
suitable attachment.
M/F Suspended Ceiling Plain (Concrete Floor)
22
Everest Wall Solution
23
Partitions in Double Skin Full Height G.I. Framework of thickness 62/88 mm
Overall Thickness
62/88mm
Duty Rating: Severe
8mm thk. Everest Fiber Cement Board
Tested as per BS 5234
Part 2
Everest Fiber
Standard GI Floor & Cement Screws
Standard GI metal stud Horizontal Runner
Ceiling Channel
SPECIFICATION
Providing and fixing, 62/88 mm thick partition using G.I sections, 8 mm thick (High Pressure Steam
Cured), Everest Fibre Cement Board (Plain/PRS (Primered, recessed and sealant coated)/Bevelled at
site), depending upon the type of finish required) conforming to IS 14862:2000, fixed on the
framework using 25 mm fully threaded self embedding type fibre cement screws @ 300 mm c/c on
either side of 48/70 mm studs (0.55 mm thick having one flange of 34 mm and another flange of 36
mm) made of G.I steel placed at 600 mm c/c in 50/72 mm floor and ceiling channel (0.55 mm thick
having equal flanges of 32 mm G.I steel) with joints staggered to avoid through joints, all complete as
per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
24
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height G.I. Framework of thickness 62/88 mm
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt height) (For groove Finish)
Area of Application:
25
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 67/80 mm
Overall Thickness
67/80mm
Everest Fiber
Everest Rondo metal Everest Rondo Floor Everest Rondo Nogging
Cement Screws
stud & Ceiling Channel Channel
SPECIFICATION
Providing and fixing, 67/80 mm thick partition using Rondo sections, 8 mm thick (High Pressure Steam
Cured), Plain / PRS (Primered, Recessed & Sealant Coated)/Bevelled at site) boards conforming to IS
14862:2000, fixed on the framework using 25 mm fully threaded self-embedding type Everest fibre
cement screws @ 300 mm c/c on either side of 51/64 mm studs (0.55 mm thick having one flange of
34 mm and another flange of 36 mm) made of Galvalume steel placed at 600 mm c/c in 51/64 mm
floor and ceiling channel (0.55 mm thick having equal flanges of 32 mm G.I steel) with joints
staggered to avoid through joints, all complete as per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
26
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 67/80 mm
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)
Everest Fibre Track Noggin Stud Fiber Wood Paper Elasto Jointing
Cement Boards gs Cemen en Tape Compound
2420 mm x t Screws
1220 mm Screws & PVC
Fastne
rs
195.2 Sq.m. 80 80m 166 2850 68 nos. 320 5.00 Kgs 110 Kg
mts. mts. nos. mts.
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)
Area of Application:
27
Partitions in Double Skin Full Height G.I. Framework of thickness 62/84/68/90 mm
Overall Thickness
62/84/68/90mm
6/9mm Everest Heavy Duty Fiber Cement Boards Duty Rating: Severe
Tested as per BS 5234
Part 2
Everest Fiber
Standard GI Floor & Standard GI Horizontal
Standard GI metal stud Cement Screws
Ceiling Channel Runner
SPECIFICATION
Providing and fixing, 62/84/68/90 mm thick partition using G.I sections, 6 mm /9 mm thick (High
Pressure Steam Cured), Everest Heavy Duty Fibre Cement Board conforming to IS 14862:2000, fixed
on the framework using 25 mm fully threaded self-embedding type fibre cement screws @ 300 mm c/c
on either side of 48/70 mm studs (0.55 mm thick having one flange of 34 mm and another flange of 36
mm) made of G.I steel placed at 600 m c/c in 50/72 mm floor and ceiling channel (0.55 mm thick
having equal flanges of 32 mm G.I steel) with joints staggered to avoid through joints, all complete as
per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
28
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height G.I. Framework of thickness 62/84/68/90 mm
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)
Everest Track Horizon Stud Fiber Wood Paper Elasto Jointing
Fibre tal Cement en Tape Compound
Cement Runner Screws Screw
Boards s&
2420 mm PVC
x 1220 Fastne
mm rs
195.2 80 80 mts. 166 2850 68 nos 320 6.00 Kgs 110 Kg
Sq.m. mts. mts. nos mts.
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)
Area of Application:
Overall Thickness
63/76/69/82mm
Everest Fiber
Everest Rondo metal Everest Rondo Floor Everest Rondo Nogging
Cement Screws
stud & Ceiling Channel Channel
SPECIFICATION
Providing and fixing, 63/76/69/82 mm thick partition using Rondo sections, 6 / 9 mm thick (High
Pressure Steam Cured), Everest Heavy Duty Fibre Cement Boards conforming to IS 14862:2000, fixed
on the framework using 25 mm fully threaded self -embedding type Everest fibre cement screws @ 300
mm c/c on either side of 51/64 mm studs (0.55 mm thick having one flange of 34 mm and another
flange of 36 mm) made of Galvalume steel placed at 600 mm c/c in 51/64 mm floor and ceiling
channel (0.55 mm thick having equal flanges of 32 mm G.I steel) with joints staggered to avoid
through joints, all complete as per the drawing & directions of engineer-in-charge.
The boards may be finished so as to have uniform gap/groove or flush finish. The flush finish should be
done with Elasto prefab joint sealant, Everest Internal Jointing Compound and paper tape as per the
procedure laid down by the company. Alternatively, uniform gap/grooves may be covered with
30
decorative molding or may be finished with expansion filler. Finally, if specified, the boards are to be
painted with 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Double Skin Full Height Everest Rondo Framework of thickness 63/76/69/82
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For Jointless Finish)
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)
Area of Application:
32
Wall Panelling with G.I. Framework
Overall Thickness
32/34mm
Perimeter channel0.55mm
Thick 27mm wide, having
two flanges of 20mm &
30mm each
Bill of Quantity (For 100 Sq.m) (For 2.44 mt. height) (For Jointless Finish)
Bill of Quantity (For 100 Sq.m.) (For 2.44 mt. height) (For groove Finish)
Area of Application:
34
Solid Wall Panel
35
Partitions in Solid Wall Panels of thickness 50/75 mm
Overall Thickness
50 / 75 mm
Sound Insulation: 38 dB
Wooden screw of 8 mm
dia and 35 mm length
along with PVC dash
fastners for fixing floor
and ceiling channels fixed
at 600 mm c/c.
SPECIFICATION
SPECIFICATIONS OF SWP :
Providing and fixing 50/75mm thick non asbestos Fibre reinforced aerated cement sandwich
modules made out of light weight fibre reinforced areated cement/ concrete core composed of
portland cement, flyash, binders etc., and 4mm thick non asbestos fibre cement borads confirming
to IS 14862;2000 and ISO : 8336:1993(E) on either side of the core, having a tongue and groove
on logitudinal side of the modules. These Panel modules are erected/ installed using galvanised
iron steel tracks of 1mm thick & of size 14x50x25mm as bottom track, 25x50x25mm as top track
36 for
for fixing to the floor and top of the wall respectively including all necessary material required
errecting & fixing the wall panel complete as per direction of Engineer-in-charge (for payment net
area of wall to be measured.). Finally, if specified, the SWP are to be painted with 2 coats of acrylic
emulsion paint of approved shade/make, over a coat of cement primer.
Partitions in Solid Wall Panels of thickness 50/75 mm
Area of Application:
1. Internal Walls
2. Wet area Lining
3. External Walls
4. Cladding walls in warehouses/factories
5. Pre fabricated structure
37