T400HW03 V0 Auo
T400HW03 V0 Auo
T400HW03 V0 Auo
( )Preliminary Specifications
(*
*)Final Specifications
Frank Hsu
_________________________________ ____________________________________
Eugene CC Chen
____________________________________
Hank Chiu
____________________________________
Prepared By PM
Shelby Tong
____________________________________
Contents
No
CONTENTS
RECORD OF REVISIONS
1 GENERAL DESCRIPTION
3 ELECTRICAL SPECIFICATION
4 OPTICAL SPECIFICATION
5 MECHANICAL CHARACTERISTICS
7 INTERNATIONAL STANDARD
7-1 SAFETY
7-2 EMC
8 PACKING
9 PRECAUTION
9-5 STORAGE
Record of Revision
Version Date Page Description
0.0 2010/1/8 First release
1. General Description
This specification applies to the 40.0 inch Color TFT-LCD Module T400HW03 V0. This LCD module has a TFT
active matrix type liquid crystal panel 1,920x1,080 pixels, and diagonal size of 40.0 inch. T400HW03 V0 is a 40”
Full HD model plus high pin count series model, which is a high-end model for TV. The performance has the best
spec for technical exhibition & marketing promotion. A T400HW03 V0 model has high brightness, high contrast,
lower power consumption, less color wash-out, motion blur free, front mount bezel.
* General Information
3. Electrical Specification
The T400HW03 V0 requires two power inputs. One is employed to power the LCD electronics and to drive the TFT
array and liquid crystal. The second input for BLU is to power inverter.
LVDS
Differential Input Low Threshold Voltage VTL -100 -- -- mVDC 4
Interface
VIH
Input High Threshold Voltage 2.7 -- 3.3 VDC
CMOS (High)
Interface VIL
Input Low Threshold Voltage 0 -- 0.6 VDC
(Low)
Backlight Power Consumption PBL 114 120 126 Watt
Note :
1. The ripple voltage should be controlled under 10% of VCC
2. VDD = 12.0V, Fv = 60Hz, FCLK = 82MHz , 25 ℃, Test Pattern : White Pattern
3. Measurement condition : Rising time = 400us
VDD
90%
10%
GND
400 µs
V TH
V ICM
VTL
0V
C lo ck
C H x_0+ R1 R0 G0 R5 R4 R3 R2 R1 R0 G0
C H x_0-
C H x_1+ G2 G1 B1 B0 G5 G4 G3 G2 G1 B1
C H x_1-
C H x_2+
C H x_2- B3 B2 DE NA NA B5 B4 B3 B2 DE
C H x_3+
C H x_3- R7 R6 NA B7 B6 G7 G6 R7 R6 NA
C lo ck
CH x_0+ R3 R2 G2 R7 R6 R5 R4 R3 R2 G2
CH x_0-
CH x_1+ G4 G3 B3 G7B 2 G7 G6 G5 G4 G3 B3
CH x_1-
CH x_2+
CH x_2- B5 B4 DE NA NA B7 B6 B5 B4 DE
CH x_3+
CH x_3- R1 R0 NA B1 B0 G1 G0 R1 R0 NA
Timing Table
Notes:
(1) Display position is specific by the rise of DE signal only.
st st
Horizontal display position is specified by the rising edge of 1 DCLK after the rise of 1 DE, is displayed on the
left edge of the screen.
(2)Vertical display position is specified by the rise of DE after a “Low” level period equivalent to eight times of
st st
horizontal period. The 1 data corresponding to one horizontal line after the rise of 1 DE is displayed at the top
line of screen.
(3)If a period of DE “High” is less than 1920 DCLK or less than 1080 lines, the rest of the screen displays black.
(4)The display position does not fit to the screen if a period of DE “High” and the effective data period do not
synchronize with each other.
Page 10 / 28
Tv M pixel
Tblk(v) Tdisp(v)
N L in e
Th
DE
CLK
Th
Tclk
Tdisp(h) Tblk(h)
DE
3.4 Signal Timing Waveforms
Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel
CH1 M-7 M-5 M-3 M-1
Invalid Data
1 3 5 7 9 11 M-5 M-3 M-1
Invalid Data
1 3
Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel
CH2 M-6 M-4 M-2 M
Invalid Data
2 4 6 8 10 12 M-4 M-2 M
Invalid Data
2 4
T400HW03 V0 Product Specification
更多屏规格书请登录 【液晶仓库】 www.goodpanel.net Rev. 00
Values
Parameter Unit
Min. Type. Max.
t1 0.4 --- 30 ms
t2 0.1 --- --- ms
t3 300 --- --- ms
*1
t4 0 --- --- ms
t5 0 --- --- ms
*2
t6 --- --- --- ms
t7 500 --- --- ms
t2a 10 --- 100 ms
*3 *3
t2b 0 --- 100 ms
t2c 10 --- --- ms
Note:
(1) T4=0 : concern for residual pattern before BLU turn off.
(2) T6 : voltage of VDD must decay smoothly after power-off. (customer system decide this value)
(3) T2b : customer decide this value
Spec
Item Symbol Condition Unit Note
Min Typ Max
ON 2 - 5.5 -
5 On/Off control voltage VBLON VDDB=24V VDC
OFF 0 - 0.8 -
(Note*) IF External PWM function includes 10% dimming ratio. Judge condition as below:
(1) Backlight module must be lighted ON normally.
(2) All protection function must work normally.
(3) Uniformity and flicker could NOT be guaranteed
10%
Power Input for BLU
(VDDB)
T1 T2 T5
VDDB(typ.)*0.8
Value
Parameter Units
Min Typ Max
T1 20 - - ms
T2 500 - - ms
T3 250 - - ms
T4 0 - - ms
T5 1 - - ms
T6 - - 10 ms
4. Optical Specification
Optical characteristics are determined after the unit has been ‘ON’ and stable for approximately 45 minutes in a
dark environment at 25°C. The values specified are at an approximate distance 50cm from the LCD surface at a
viewing angle of φ and θ equal to 0°.
Fig.1 presents additional information concerning the measurement equipment and method.
SR3 or equivalent
Values
Parameter Symbol Unit Notes
Min. Typ. Max
Contrast Ratio CR 4000 5000 -- 1
2
Surface Luminance (White) LWH 360 450 -- cd/m 2
Luminance Variation δWHITE(9P) -- -- 1.3 3
Response Time (G to G) Tγ -- 6.5 -- ms 4
Color Gamut NTSC 72 %
Color Coordinates
Red RX 0.640
RY 0.330
Green GX 0.290
GY 0.600
Typ.-0.03 Typ.+0.03
Blue BX 0.144
BY 0.060
White WX 0.280
WY 0.290
Viewing Angle 5
x axis, right(φ=0°) θr -- 89 -- degree
x axis, left(φ=180°) θl -- 89 -- degree
y axis, up(φ=90°) θu -- 89 -- degree
y axis, down (φ=270°) θd -- 89 -- degree
Note:
2. Surface luminance is luminance value at point 5 across the LCD surface 50cm from the surface with all pixels
displaying white. From more information see FIG 2. When lamp current IH = 11mA. LWH=Lon5 where Lon5 is
the luminance with all pixels displaying white at center 5 location.
3. The variation in surface luminance, δWHITE is defined (center of Screen) as:
δWHITE(9P)= Maximum(Lon1, Lon2,…,Lon9)/ Minimum(Lon1, Lon2,…Lon9)
4. Response time T γ is the average time required for display transition by switching the input signal for five
luminance ratio (0%,25%,50%,75%,100% brightness matrix) and is based on Fv=60Hz to optimize.
Measured Target
Response Time 0% 25% 50% 75% 100%
0% 0% to 25% 0% to 50% 0% to 75% 0% to 100%
25% 25% to 0% 25% to 50% 25% to 75% 25% to 100%
Start 50% 50% to 0% 50% to 25% 50% to 75% 50% to 100%
75% 75% to 0% 75% to 25% 75% to 50% 75% to 100%
100% 100% to 0% 100% to 25% 100% to 50% 100% to 75%
4. Viewing angle is the angle at which the contrast ratio is greater than 10. The angles are determined for the
horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the LCD surface. For
more information see FIG4.
FIG. 2 Luminance
H/2 1 2 3
4 5 6 H
7 8
H/6
V/6 V/2
The response time is defined as the following figure and shall be measured by switching the input signal for “any
level of grey(bright) “ and “any level of gray(dark)”.
Any level of gray (Bright) Any level of gray (Dark) Any level of gray (Bright)
0%, 25%, 50%, 75%, 100% 0%, 25%, 50%, 75%, 100%
Photodetector
Output
T γ (F) T γ (R)
5. Mechanical Characteristics
The contents provide general mechanical characteristics for the model T400HW03 V0. In addition the figures in the
next page are detailed mechanical drawing of the LCD.
Horizontal 952.0 mm
Vertical 551.0 mm
Outline Dimension
Depth 53.2 mm
Horizontal 891.7 mm
Bezel Opening
Vertical 504.2 mm
Horizontal 885.6mm
Active Display Area
Vertical 498.15mm
Front View
Back View
Duration: X, Y, Z 30min
Height: 38.1cm
8 Drop test (With carton) 3 1 corner, 3 edges, 6 surfaces
(ASTMD4169-I)
7. International Standard
7.1 Safety
(1) UL 60950-1, UL 60065; Standard for Safety of Information Technology Equipment Including
electrical Business Equipment.
(2) IEC 60950-1 : 2001, IEC 60065:2001 ; Standard for Safety of International Electrotechnical
Commission
(3) EN 60950 : 2001+A11, EN 60065:2002+A1:2006; European Committee for Electrotechnical
Standardization (CENELEC), EUROPEAN STANDARD for Safety of Information Technology
Equipment Including Electrical Business Equipment.
7.2 EMC
(1) ANSI C63.4 “Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electrical Equipment in the Range of 9kHz to 40GHz. “American National standards Institute(ANSI),
1992
(2) C.I.S.P.R “Limits and Methods of Measurement of Radio Interface Characteristics of Information
Technology Equipment.” International Special committee on Radio Interference.
(3) EN 55022 “Limits and Methods of Measurement of Radio Interface Characteristics of Information
Technology Equipment.” European Committee for Electrotechnical Standardization. (CENELEC),
1998
8. Packing
8-1 DEFINITION OF LABEL:
A. Panel Label:
*xxxxxxxxxxxx-xxxx*
AU Optronics
(2) For RoHs compatible products, AUO will add RoHS for identification.
Note: The green Mark will be present only when the green documents have been ready by AUO internal green
team. (definition of green design follows the AUO green design checklist.)
B. Carton Label:
QTY : 3
T400HW03 V0
97.40T04.000
瓦楞紙板
Stretch film
Corner angle
Pallet
9. PRECAUTIONS
Please pay attention to the followings when you use this TFT LCD module.
(2) You should consider the mounting structure so that uneven force (ex. twisted stress) is not applied
to module. And the case on which a module is mounted should have sufficient strength so that
external force is not transmitted directly to the module.
(3) Please attach the surface transparent protective plate to the surface in order to protect the polarizer.
Transparent protective plate should have sufficient strength in order to the resist external force.
(4) You should adopt radiation structure to satisfy the temperature specification.
(5) Acetic acid type and chlorine type materials for the cover case are not desirable because the former
generates corrosive gas of attacking the polarizer at high temperature and the latter cause circuit
broken by electro-chemical reaction.
(6) Do not touch, push or rub the exposed polarizer with glass, tweezers or anything harder than HB
pencil lead. And please do not rub with dust clothes with chemical treatment. Do not touch the
surface of polarizer for bare hand or greasy cloth. (Some cosmetics are detrimental to the polarizer.)
(7) When the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials
like chamois soaks with petroleum benzene. Normal-hexane is recommended for cleaning the
adhesives used to attach front/ rear polarizer. Do not use acetone, toluene and alcohol because
they cause chemical damage to the polarizer.
(8) Wipe off saliva or water drops as soon as possible. Their long time contact with polarizer causes
deformations and color fading.
(9) Do not open the case because inside circuits do not have sufficient strength.
9-5 STORAGE
When storing modules as spares for a long time, the following precautions are necessary.
(1) Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep the
temperature between 5 ℃ and 35℃ at normal humidity.
(2) The polarizer surface should not come in contact with any other object. It is recommended that they
be stored in the container in which they were shipped.