Experiment No: 1 Roll No:
Date:
1. DETERMINE THE DISCHARGE FROM A GIVEN TANK PRESENT IN TATA
CHEMICAL LABORATORY (using ORIFICE)
AIM
To determine the coefficient of discharge of orifice by constant head method
BASIC CONCEPT
An orifice is an opening having a closed perimeter, made in the walls or in the
bottom of the tank containing fluid, through which fluid may be discharged. The
discharging fluid from the tank through the orifice comes out in the form of a free jet.
In the process, the total energy of the fluid in the tank is converted to kinetic energy
as the jet issues out into the atmosphere. The shape of the jet is function of the
geometry of the orifice. The jet cross-section contracts to minimal and then expands
partly due to viscous resistance offered by the surrounding atmosphere and partly
due to inertia of the fluid particles. The jet cross-sectional area at which it is having
minimum area is known as “Vena Contracta”.
The following formulae are employed to fine the coefficient of discharge of an
orifice.
Theoretical discharge, Qth =a √ 2 gh
d2
a = area of cross section of the orifice = 4
h = head of the liquid above the centre of the orifice in the tank
g = acceleration due to gravity
Actual discharge, Qa = AH/T
A = Internal plan area of collecting tank
H = Rise of liquid in collecting tank
T = Time taken to collect liquid in the collecting tank
Coefficient of discharge, Cd= Qat/Qth
1
APPARATUS
1 Orifice fitted to a tank
2 Piezometers
3 Meter scale
4 Calipers
5 Stop watch
6 Collecting tank fitted with a valve
PROCEDURE
1. The diameter of the orifice and the internal plan dimensions of the collecting tank
are measured.
2. The supply valve of the orifice tank is regulated and water is allowed to fill the
orifice tank to a constant head (h)
3. The out let valve of the collecting tank is closed tightly and the time taken for “H”
rise of water in the collecting tank is noted.
4. The above procedure is repeated for different heads and the readings are
tabulated.
OBSERVATIONS AND CALCULATIONS
Table 1. Results of flow through orifice experiment (Constant head)
S.No. Head (m) Time for H cm rise Discharge (Q) m3 / s Coefficient of
(T) - sec discharge, Cd
Qa Qth
1 0.6 18.27 4.3787 x 10-4 6.0626 x 10-4 0.7222
2 0.5 20.54 3.8948 x 10-4 5.5344 x 10-4 0.7037
3 0.4 23.46 3.4100 x 10-4 4.9501 x 10-4 0.6888
4 0.3 27.16 2.9455 x 10-4 4.2869 x 10-4 0.6870
5 0.2 34.87 2.2942 x 10-4 3.500 x 10-4 0.6554
2
Diameter of orifice, d = 15 mm
Dimensions of collecting tank, A = 400 mm x 400 mm
GRAPHS
The following graph is drawn by taking Qa on y – axis and Qth on x - axis.
Qa vs Qth
Qa v Qth
5
4.5
4
3.5
3
2.5
Qa
2
1.5
1
0.5
0
0 2 4 6 8 10 12
Qth
The slope obtained from the above graph = 0.7609
RESULT
The coefficient of discharge of orifice, Cd = 0.6914
(From experiment)
The coefficient of discharge of orifice, Cd = 0.7609
(From Qa vs Qth graph)
INFERENCE
The coefficient of discharge found through experiment is approximately equal to
value found through graph.