SEWAGE PUMPS
MYERS WHR SERIES
®
The Myers WHR series sewage
pumps feature all cast iron
construction to withstand the most
extreme conditions. Available in
single seal, and double seal models
for additional protection against
water leakage. The enclosed
two-vane impeller provides high-
efficiency pumping and will handle
stringy, trashy 2” solids without
clogging. Designed for sewage
and effluent and can be used for
applications requiring high heads.
applications
Domestic wastewater and
features
septic systems
Versatile Applications Cool Running
specifications
Ideal for residential and commercial Durable, oil-filled motor for con-
Capacities – 178 GPM (673.8 LPM) sewage, domestic wastewater and tinuous bearing lubrication and
Shut-off Head – 33’ (10.1 m) septic systems maximum heat dissipation
Solids Handling – 2” (50.8 mm) Non-clog Design Powerful Starts
Liquids Handling – Drain water and Recessed impeller provides maximum High-torque, permanent split
domestic sewage efficiency and eliminates jamming capacitor (PSC) motor; no starting
Intermittent Liquid Temperature – between volute case – cast iron switches or relays to wear out
Up to 140°F (60°C) construction Thermal Protection
Motor/Electrical Data – 1/2 HP, 115V, Leak Detection Heat sensor overload protection with
1Ø, 60Hz, permanent split capacitor Optional leak probe senses water automatic reset when motor cools to a
type; 1/2, 3/4, 1 HP, 230V, 1Ø, 60 Hz, leakage past seal (dual seal motors safe operating temperature
permanent split capacitor type; only) High-capacity Handling
208/230/460/575V, 3Ø, 60Hz
Passes full 2” solids
Acceptable pH Range – 5-9
Discharge, NPT – 2” (50.8 mm);
3” (76.2 mm)
Housing – Cast iron
Power Cord – WHR–SJOW/SJOW-A 20’,
16/3, 1Ø; 20’, 16/4, 3Ø;
WHR-DS – 20’, 14/4, 1Ø; 20’, 14/3, 1Ø, L/D;
20’, 16/4, 3Ø, L/D
Impeller – Cast iron, vortex
Volute Case – Cast iron
Shaft Seal – Single type 21, carbon/
ceramic, double tandem carbon/ceramic
Minimum Sump Diameter –
Simplex: 24” (61 cm); Duplex: 30” (76 cm)
1
SEWAGE PUMPS
MYERS WHR SERIES
®
ordering information
Approx.
Catalog Phase/ Discharge Switch Cord Wt.
Number HP Volts Cycles Size Type Length Lbs.
WHR SERIES (Single Seal)
WHR5-11C 1/2 115 1/60 2” Manual 20’ 75
WHR5-21C 1/2 230 1/60 2” Manual 20’ 75
WHR5P-1* 1/2 115 1/60 2” Automatic* 20’ 76
WHR5P-2* 1/2 230 1/60 2” Automatic* 20’ 76
WHR5-03 1/2 200 3/60 2” Manual 20’ 75
WHR5-23 1/2 230 3/60 2” Manual 20’ 75
WHR5-43 1/2 460 3/60 2” Manual 20’ 75
WHR5-53 1/2 575 3/60 2” Manual 20’ 75
WHR7-21C 3/4 230 1/60 2” Manual 20’ 79
WHR7P-2* 3/4 230 1/60 2” Automatic* 20’ 80
WHR7-03 3/4 200 3/60 2” Manual 20’ 79
WHR7-23 3/4 230 3/60 2” Manual 20’ 79
WHR7-43 3/4 460 3/60 2” Manual 20’ 79
WHR7-53 3/4 575 3/60 2” Manual 20’ 79
WHR10-21C 1 230 1/60 2” Manual 20’ 85
WHR10P-2* 1 230 1/60 2” Automatic* 20’ 86
WHR10-03 1 200 3/60 2” Manual 20’ 85
WHR10-23 1 230 3/60 2” Manual 20’ 85
WHR10-43 1 460 3/60 2” Manual 20’ 85
WHR10-53 1 575 3/60 2” Manual 20’ 85
Phase/ Discharge Switch Cord Approx.
Catalog Number HP Volts Cycles Wire Size Size Type Length Wt. Lbs.
WHR SERIES (Double Seal)
WHR5-11-DS 1/2 115 1 14/4 2” Manual 20’ 80
WHR5-01-DS 1/2 208 1 14/4 2” Manual 20’ 80
WHR5-21-DS 1/2 230 1 14/4 2” Manual 20’ 80
WHR5-11-DS-L/D 1/2 115 1 16/3 2” Manual 20’ 80
WHR5-01-DS-L/D 1/2 208 1 16/3 2” Manual 20’ 80
WHR5-21-DS-L/D 1/2 230 1 16/4 2” Manual 20’ 80
WHR5-03-DS-L/D 1/2 208 3 16/4 2” Manual 20’ 80
WHR5-23-DS-L/D 1/2 230 3 16/4 2” Manual 20’ 80
WHR5-43-DS-L/D 1/2 460 3 16/4 2” Manual 20’ 80
WHR5-53-DS-L/D 1/2 575 3 16/4 2” Manual 20’ 80
WHR7-21-DS 3/4 230 1 14/4 2” Manual 20’ 85
WHR7-21-DS-L/D 3/4 230 1 16/3 2” Manual 20’ 85
WHR7-03-DS-L/D 3/4 208 3 16/4 2” Manual 20’ 85
WHR7-23-DS-L/D 3/4 230 3 16/4 2” Manual 20’ 85
WHR7-43-DS-L/D 3/4 460 3 16/4 2” Manual 20’ 85
WHR7-53-DS-L/D 3/4 575 3 16/4 2” Manual 20’ 85
WHR10-01-DS 1 208 1 14/4 2” Manual 20’ 90
WHR10-21-DS 1 230 1 14/4 2” Manual 20’ 90
WHR10-21-DS-L/D 1 230 1 16/3 2” Manual 20’ 90
WHR10-03-DS-L/D 1 208 3 18/4 2” Manual 20’ 90
WHR10-23-DS-L/D 1 230 3 18/4 2” Manual 20’ 90
WHR10-43-DS-L/D 1 460 3 18/4 2” Manual 20’ 90
WHR10-53-DS-L/D 1 575 3 18/4 2” Manual 20’ 90
2
SEWAGE PUMPS
MYERS WHR SERIES
®
DIMENSIONS
WHR-P
WHR
WHR-DS
181/8
(460)
PUMP PERFORMANCE FULL LOAD AMP DATA
Single Seal Dual Seal FLA
Capacity liters per minute
WHR5-11 WHR5-11-DS 10.5
0 100 200 300 400 500 600 700
WHR5-01 WHR5-01-DS 8
35 WHR5-21 WHR5-21-DS 5.25
10
WHR5-03 WHR5-03-DS 3.6
30 WHR5-23 WHR5-23-DS 3.2
WH WHR5-43 WHR5-43-DS 1.6
R1 8
25 0 WHR5-43 WHR5-43-DS 1.3
1H
P
Total head in meters
WH & WHR7-01 WHR7-01-DS 7
Total head in feet
R7 WH
3/ R1
20 WH
R5 4H 0-
DS 6 WHR7-21 WHR7-21-DS 7
P
&
1/
2H WH WHR7-03 WHR7-03-DS 5.1
P R7
15 &
WH -D
S WHR7-23 WHR7-23-DS 4.1
R5
-D
4 WHR7-43 WHR7-43-DS 2
S
10 WHR7-53 WHR7-53-DS 1.6
WHR10-01 WHR10-01-DS 10.8
2
5 WHR10-21 WHR10-21-DS 9.4
WHR10-03 WHR10-03-DS 6
0 0 WHR10-23 WHR10-23-DS 5.2
0 50 100 150 200
WHR10-43 WHR10-43-DS 2.6
Capacity gallons per minute
WHR10-53 WHR10-53-DS 2.4
3
SEWAGE PUMPS
MYERS WHR SERIES
®
SPECIFICATIONS
Operating Conditions – Each pump shall have a capacity of ___ GPM at a total head of ___ feet and motor size
shall be ___ horsepower, ___ phase 60 Hz for operation at ___volts and complete performance as shown on curve sheet.
Pump – The sewage pump shall be WHR series as manufactured by F. E. Myers, Ashland, Ohio or equal. Pump shall
be of the submersible type with recessed impeller to give complete unobstructed volute opening for passing of solids. Pump shall
pass 2” diameter solids.
Discharge of pump shall be provided with bolt on 2” NPT flange or optional 3” NPT flange so that 2” or 3” pipe size may be used.
Motor – Pump motor shall be of the submersible type rated 1/2, 3/4, or 1 horsepower as required. Motor shall operate at 1750 RPM
and shall be for 208 or 230 volts single phase or 200, 230, 460, or 575 volts three phase. Single phase motors shall be of the
permanent split capacitor type with no relays or starting switches.
Stator winding shall be of the open type with Class A (105°C) insulation for operating in clean dielectric oil that
lubricates bearings and seals and cools the winding. Stator shall be pressed into housing for the best alignment and heat transfer.
Common motor pump shaft shall be of 416 stainless steel and shall be heat shrunk into the die cast motor rotor. Rotor shaft shall be
supported by a lower ball bearing to take thrust and radial loads and by an upper bronze sleeve bearing to take radial load only.
Single phase motor shall have an overload element embedded in the winding to protect the motor against over current and
overheating conditions. Overload element shall automatically reset when motor cools.
Three phase motor shall be protected by 3 leg overload element in control box. Overload shall be of the quick trip ambient compen-
sated type and shall have a manual reset button.
Motor to be a completely assembled unit with end plate for mounting in volute case. Complete motor and pump impeller to be
removable as a unit from the volute casing.
Corrosion Protection – All iron castings shall be pretreated with phosphate and chromic rinse and shall be painted with a high
quality, lead free, alkyd enamel air dry paint. All fasteners to be 302 stainless steel.
Shaft Seals (Single Seal) – Motor shall be protected by a rotating mechanical seal. Seal face shall be carbon and ceramic and lapped
to a flatness of one light band.
Shaft Seals (Double Seal) – Motor shall be protected by two mechanical seals mounted in tandem with a seal chamber between the
seals. Seal chamber shall be oil filled to lubricate seal face and to transmit heat from shaft to outer shell. Seal face shall be carbon
and ceramic and lapped to a flatness of one light band.
An optional electrode (1 phase only) shall be mounted in the seal chamber to detect any water entering the chamber through the
lower seal. Water in the chamber shall cause a red light to turn on at the control box. This signal shall not stop the motor, but shall
act as a warning only, indicating service is required.
Impeller – Shall be cast iron and of the recess type. Pump-out vane shall be used on back shroud. Impeller shall be dynamically
balanced. Impeller to be threaded on shaft and held in position with locknut. Impeller and motor shall have top lift-out of case so that
the assembly can be removed without disturbing any piping.
Pump Case – The volute case shall be of cast iron and shall be provided with bolt-on flange so the 2” pipe size may be used.
Cord Seal – The cord shall be potted into a steel connector with polyurethane resin for leak proof seal. A cord nut and rubber
grommet shall clamp the cord into the bushing. Cords shall withstand a pull of 100 pounds.
USA CANADA
293 Wright Street, Delavan, WI 53115 WWW.FEMYERS.COM 490 Pinebush Road, Unit 4, Cambridge, Ontario N1T 0A5
PH: 888-987-8677 ORDERS FAX: 800-426-9446 Ph: 800-363-7867 ORDERS Fax: 888-606-5484
Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
© 2014 Pentair Ltd. All Rights Reserved. M9033SSE (12/05/14)