Controlador Del FP-RVC
Controlador Del FP-RVC
Alarm indication
Active outputs
Inductive/capacitive PF
Disconnection indication Measurement unit
Overtemperature indication Programmable parameters :
User programmable parameters • Target Power Factor (cos ϕ)
/ measurement
• Phase shift (for special connections)
• C/k (starting current)
• Switching delay times
• Switching sequence
Keypad
Easy commissioning with
automatic recognition of :
• Special connections
Automatic / manual set mode
(single-phase, CT leads)
• Number of outputs
• Type of switching
sequence
Automatic setting of :
• Phase shift
• C/k
• Switching delay
• Type of switching
sequence
Powerful features
Common range for all network voltages from 100V to 440V.
Measurement and display of key parameters like voltage, current, power factor, THDV and THDI.
Fully programmable switching sequence.
1A or 5A current input.
Easy commissioning.
Complete auto set-up (starting current-C/k, type of switching sequence, phase shift, special connections).
Easy to use thanks to a user-friendly interface and ease of access to parameters for manual setting.
Highly efficient switching strategy combining integral, direct and circular switching.
This allows to : • control the cos ϕ in presence of rapidly varying loads,
• reduce the number of switching,
• avoid unnecessary intermediary switchings,
• increase the lifetime of the capacitors and contactors.
Suitable for hot environments thanks to max. ambient temperature rating of 60°C.
Not affected by the harmonics.
Overvoltage / undervoltage protection and protections against harmonic distortion (THDV).
Alarm : an alarm contact is opened when any of these conditions are reached:
• the target cos ϕ is not reached within 6 minutes after all outputs have been switched on,
• the internal temperature of the RVC rises above 85°C,
• overvoltage / undervoltage limits are reached,
• the power supply is out of range,
• the THDV exceeds the limits.
2
Easy commissioning Easy programming
The AUTO SET mode allows the RVC commissioning All parameters are easily accessible
in only 2 simple steps : for manual setting.
•C/k
•Switching sequence
MAN
AUTO SET
PHASE
C/k
DELAY
STEPS
or
3
Technical specification
Wiring diagram
While all care has been taken to ensure that the information contained in this publication is correct, no responsibility can be accepted
for any inaccuracy. We reserve the right to alter or modify the information contained herein at any time in the light of technical or other
developments. Technical specifications are valid under normal operating conditions only. We do not accept any responsibility for
www.abb.com/lowvoltage any misuse of the product and cannot be held liable for indirect or consequential damages.