Betriebsanleitung Operating Instructions Mode D'emploi Instrucciones de Servicio
Betriebsanleitung Operating Instructions Mode D'emploi Instrucciones de Servicio
ProMinent
Betriebsanleitung
Operating Instructions
Mode d’emploi
Instrucciones de servicio
ProMinent® CONCEPTPLUS
Part No. 987033 ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany BA CO 015 02/05 G/GB/F/E
Downloaded from www.Manualslib.com manuals search engine
D Betriebsanleitung in Deutsch von Seite 3 bis 13
2 ProMinent
®
Page
General user instructions 16
1 Equipment overview .................................................................. 17
2 Type overview/material details ................................................. 18
3 Safety........................................................................................... 18
4 Storage and transport ............................................................... 19
5 Assembly and installation ......................................................... 19
6 Commissioning .......................................................................... 20
7 Maintenance ............................................................................... 20
8 Repair .......................................................................................... 21
9 Troubleshooting ......................................................................... 21
10 Decommissioning and disposal ............................................... 22
11 Technical data ............................................................................ 22
12 Accessories ................................................................................ 23
Declaration of Conformity 25
ProMinent ®
15
Downloaded from www.Manualslib.com manuals search engine
General user instructions
Please read through the following user instructions carefully! They will
help you get the best use out of the operating instruction manual.
• Enumerated points
Instructions
▲
Safety guidelines:
WARNING
IMPORTANT
16 ProMinent ®
1 Equipment overview
2 7
The leakage bore is between the suction valve and the drive housing.
ProMinent ®
17
Downloaded from www.Manualslib.com manuals search engine
Type overview/material details / Safety
3 Safety
Correct use of • The pump may be used only for metering liquid media!
equipment • All other uses or modifications are prohibited!
• The pump is not suitable for metering gaseous media or solids!
• The pump must be operated by appropriately trained and authorised
personnel!
The personnel must be familiar with metering pumps and their operation!
WARNING
• The pump may start to operate as soon as it connected to the mains
power supply!
Ensure that no hazardous metering chemical can leak out!
If you have not done so, set the multifunction switch to STOP or
disconnect the pump from the mains immediately.
• The pump cannot be switched off! In the case of an electrical failure,
disconnect the mains cable from the power supply.
• Disconnect the power cable from the mains before working on
the pump.
18 ProMinent®
Sound pressure level The sound pressure level is < 70 dB (A) at a distance of 1 m in accordance
with EN 23741 or EN 23742 at maximum stroke, maximum stroke rate, maxi-
mum back pressure (water)
IMPORTANT
• The pump must not vibrate when installed.
• Solenoid metering pumps tend to overfeed if the back pressure
is too low. In this case fit a ball check valve, a multifunction valve
or a discharge valve with 1.5 bar opening pressure downstream
from the pump (not 0213).
ProMinent ®
19
Downloaded from www.Manualslib.com manuals search engine
Assembly and installation / Commissioning / Maintenance
• Use only original hoses with the specified diameter and wall
thickness! It is not otherwise possible to ensure the durability of
the connection to the pump valves!
• For tips on hydraulic installation, order the ”General Operating
Instructions Manual, ProMinent® Solenoid Metering Pumps”
(Order No. 987057).
• Check that the mains power supply and frequency match the
values specified on the rating plate!
• Note all national directives which apply to the installation!
washers (Ø 6 mm).
Hose
Keep suction height and length of suction hose as short as possible.
▲
grommet
O-Ring Push union nut and clamping ring onto the hose.
Push the cut hose onto the grommet up to the stop.
intake Press on hose and tighten the union nut.
connector
Mount the foot-actuated valve.
For this purpose, cut the free suction hose end such that the foot-
actuated valve is suspended close above the tank bottom.
In case of metering solutions with contaminations or residues, cut
the free suction hose end such that the foot-actuated valve is
suspended at least 50 mm above the tank bottom.
6 Commissioning
7 Maintenance
Check the overall tightness of the liquid end (in particular leakage
opening between suction value and drive housing)
▲
20 ProMinent ®
8 Repair
9 Troubleshooting
The pump does not prime despite full stroke action and venting
Cause: Crystalline deposits on the ball seat due to valves drying out.
Remedy: Remove suction hose from the supply tank and rise liquid
end thoroughly.
If unsuccessful, dismantle valves and clean.
ProMinent ®
21
Downloaded from www.Manualslib.com manuals search engine
Decommissioning and disposal / Technical data
IMPORTANT
• When decommissioning a pump, clean all traces of chemicals
and dirt from the housing and particularly the liquid end.
• Observe all relevant disposal directives for your area
(particularly with regard to electronic waste)
11 Technical data
Pump Minimum delivery rate Minimum feed rate Max. Connection Priming Priming Admissible
type at maximum at medium stroke size lift* lift** priming pressure
back pressure back pressure rate ext. Ø x int. Ø Intake
ml/ ml/ strokes/
bar l/h stroke bar l/h stroke min mm m Wc m Wc bar
Materials
Electrical data
Mains frequency: 50 Hz / 60 Hz
22 ProMinent ®
Temperature details
Storage and transport temperature: -10 °C...+50 °C
Function at ambient temperature: -10 °C...+45 °C
Admissible feed chemical temperature: -10 °C...+35 °C
Climate
Admissible relative air humidity: 92 %, non condensing.
Load in wet and alternating climate: FW 24 in accordance with DIN 50016.
Shipping weight
Shipping weight: 1.8 kg
12 Accessories
Suction lances Suction lance for 200 l drum, tank opening 2“ DIN 570, PPE 1022511
Suction lance for 200 l drum, tank opening 2“ DIN 570, PCB 1022512
Suction lance for tank 5-50 l drum, tank opening d50, PPE 1022645
Suction lance for tank 5-50 l drum, tank opening d50, PCB 1022644
ProMinent ®
23
Downloaded from www.Manualslib.com manuals search engine
Technical data
158.7
132.5
84.7
18.3
80
6
92.5
M20 x1.5
140 (156*)
70 (90*)
10.5 33.9
56.1
105.3 76
98 (110*)
24 ProMinent
®
ProMinent ®
25