Elevator Inverter HIVD 700 GS Inverter Introduction Book
Elevator Inverter HIVD 700 GS Inverter Introduction Book
Elevator Inverter HIVD 700 GS Inverter Introduction Book
The main circuit includes the converter as a rectifier of AC power, the reactor to decrease
ripples of DC power, the condenser of big capacity and device to absorb the regenerating
current on braking resistor, and IPM DSP (Digital Signal Processing) inverter changing from
DC voltage to AC voltage of variable voltage(VV) and variable Frequency(VF).
And the control circuit consists of the vector operation part using the micro-processor and
sine wave PWM (Pulse Width Modulation).
VVVF (Variable Voltage Variable Frequency) elevator system adopted the inverter unit with
the micro-processor based PWM (Pulse Width Modulation) control system for its
simultaneous control of the voltage and frequency.
With VVVF elevator system, the power consumption especially during the acceleration is
greatly reduced compared to the primary voltage control elevator system of the conventional
AC elevators.
As the VVVF elevator system supplies the most optimum voltage and frequency to the motor
continuously, the efficiency of the motor in speed and torque has been highly improved.
4-1
On Board Power Supply : 3 Phase-440V-60Hz
Elevator
Control Panel
INVERTER
Traction Motor
(3 Phase-360V-51Hz)
4-2
Figure 4.3 Wiring of Inverter Input / Output Cable
4-3
2.2 Wiring for Rotary Encoder
1) For wiring of rotary encoder lines, confirm the signal of each line and do wiring.
ENCODER
TO MCPU BOARD
MOTOR
PGM PGP PB PA
(CM2-4) (CM2-1) (CM2-3) (CM2-2)
SHIELDED
LINE
GROUNDING
AT ON-BOARD BULKHEAD
Cautions : Be careful that changing the wiring of encoder cable lines (+15VDC―PGP,
GND―PGM), can cause the encoder unit to be damaged.
4-4
SHIELDED WIRE SHIELDED WIRE
(O) (X)
The shielded wire from one end of the shield cable should be earthed (grounded).
2) If the phase lines for encoder signal (PA, PB) are inter-changed, speed feedback
and rotation of motor shall not enable.
Reconfirm the wiring of encoder cable lines before electrical power On.
3) Shielded cable should be connected to the bus-bar for field ground in control
panel.
4-5
3. DESCRIPTION OF TERMINAL FUNCTIONS
3.1 Input Terminals for HIVD-700GS Inverter
4-6
3.2 Output Terminals for HIVD-700GS Inverter
4-7
4. HHT (Hand Held Terminal) OPERATION FOR INVERTER
4.1 HHT (HHT-2000) Function
B1
B5
B8
CONNECTOR
UP
DN
LCD DISPLAY
2 x 16 (Total : 32 Characters) - Press to enter sub directory
- Press to save Data changed
by UP and DOWN keys.
Note) When Inverter Power is Off, connect HHT to Inverter Main PC Board.
4-8
4.2 HHT Menu
POWER ON
ESC
RESET
ESC
RESET
ESC ESC
RESET RESET
ESC
RESET
02 I/O FRESX123456Y123L
ENTER
ESC
RESET
03 ERROR ERROR1
ERROR2
ENTER
ESC ESC
RESET RESET
ESC
RESET
02 INTERFACE 01_X1_SELECT
ENTER
02_X2_SELECT
ESC
RESET
03 MOTOR 01_MOTOR_SELECT
ENTER
02_PG_PULSE
P
A ESC
S RESET
S
04 FACTORY W 01_AI1_OFFSET
O 02_AI1_GAIN
R ENTER
D
SPEED F BK
0 . 0 RPM
Figure 4.8 LCD Initial Display
4-9
4.4 Mode Selection
Cursor in LCD display indicates a present mode.
01 MO N I T O R
02 P R OGR A M
When you enter a sub menu, press
CURSOR ENTER
the ENTER key as shown in
01 BAS I C Figure 4.9.
02 I /O
Figure 4.9 Moving to a Selected Sub Menu
01 BAS I C
02 I / 0
When you come out to a previously
CURSOR ESC
selected menu, press the ESC key
01 MO N I T O R as shown in Fig. 4.10.
02 P R OGR A M
Figure 4.10 Moving to a Previously Selected Menu
When you choose a menu in a same directory level, press the Up or Down key.
02 EL SPEED
30 MP M
ENTER
Figure 4.11 Data Setting in
Program Menu
02 EL SPEED After selecting a program mode
30 MP M menu with the Up and Down
keys, press the ENTER key to
enter a data setting mode.
02 EL SPEED Change Data as you need, and
60 MP M press ENTER key to save.
If you do not want to save, press
ENTER SAVING DATA
the ESC key.
02 EL SPEED
60 MP M
4-10
4.6 Data Initialization
99 CNT & I NT F DA T A
OF F
ENTER
99 CNT & I NT F DA T A
OF F
0 8 * A CC
0 . 72 M/ S E C 2
4-11
5. MEMU OF HHT (In case of Inverter capacity : 11kw)
5.1 Control Function
Motor : 5.5kW (SHIDAE) Rated Speed : 30m/min Gear Ratio : 1/88
Main Sheave : Φ570 Max. RPM : 1474
4-12
5.2 Interface Function
4-13
Item Function Name Data Range Initial Value Unit
SPEED_FBK SPEED_FBK RPM
16_A01_SELECT
(Speed feedback)
TORQUE Amp
17_A02_SELECT SPEED_REF
18_A03_SELECT (Speed reference) CURRENT Amp
TORQUE
(Torque feedback)
CURRENT (RMS)
VOLTAGE (RMS)
LINK_VDC
19_A04_SELECT VOLTAGE V
DC LINK VOLTAGE
(DC link voltage)
POWER(Out power)
MOTOR_TEMP
02_Interface (Motor temperature :℃)
20_AO_1_MIN -2500~2500 2000 -
21_AO_1_MAX -2500~2500 -2000 -
22_AO_2_MIN -2500~2500 - -
23_AO_2_MAX -2500~2500 - -
24_AO_3_MIN -2500~2500 - -
25_AO_3_MAX -2500~2500 - -
26_AO_4_MIN -2500~2500 0 -
27_AO_4_MAX -2500~2500 500 -
28_DI_SELECT ON / OFF OFF -
29_RAMP_SELECT ON / OFF ON -
30_MOTOR OHP LV -100.0~300.0 120.0 -
31_MOTOR OH LV -100.0~300.0 150.0 -
4-14
5.3 Motor and Factory Function
※ When you try to change the value of the ‘Control’ and ‘Interface’, you must
change that of the ‘01_MOTOR_SELECT’ in advance and then the others are to
be changed.
4-15
6. FAULT OF HIVD-700GS INVERTER
6.1 Fault List
4-16
6.2 Troubleshooting Flow Chart for HIVD-700GS Inverter
OVER Current
NO
YES
Is
Set Motor parameter
Motor parameter NO
correctly
correct?
YES
INV. maintenance
is needed
OVER Speed
NO
4-17
6.2.3 Inverter Over Voltage Fault
OVER Voltage
Is the
Repair Braking
connection of Braking NO
Resister connection
Resister correct?
YES
INV. maintenance
is needed
MOTOR
OV Heat
Is the
connection of TH1 and Connect TH1 and THC
NO
THC to Motor correctly
correct?
YES
YES
Is the Motor
NO Change Motor
capacity OK?
YES
INV. maintenance
is needed
4-18
6.2.5 Motor Thermistor Break Fault
MOTOR
TH Break
YES
INV. maintenance
is needed.
UNDER
Voltage
YES
Is the
Input Voltage of R,S,T NO Check the Input power
correct?
YES
INV. maintenance
is needed
4-19
6.2.7 Inverter Over Load Fault
INVERTER
OL Load
NO
YES
YES
INV. maintenance
is needed
PG Break
YES
Is
Check the Encoder
the Enocoder Pulse NO
and the connection
OK?
YES
4-20
6.2.9 Inverter External Fault
EXTERNAL
Fault
YES
Is CN5 in INV.
Main Board connected NO Connect CN5 correctly
correctly?
YES
INV. maintenance
is needed
FUSE Break
Is the connection
NO Connect CN2 firmly
of CN2 OK?
YES
YES
Change INV.
Main Fuse
4-21
6.2.12 Version Error
VERSION Error
Is
ROM in Main Board NO Change ROM
changed?
YES
Initiate EEP-ROM in
PROGRAM /FACTORY/
INIT_EEPROM
4-22
APPENDIX. SYSTEM BLOCK DIAGRAM OF HIVD-700GS INVERTER
R
DBR
A110
FUSE
FAN
7
6 DCR
B110
+ U
C R IGBT
- V
R MOTOR
W
T
+
C R
-
HCT
PG
N PPG
M
P ENCODER
P
A
B
HCT
P_BUS
VWPC
VWP1
VVP1
VUP
PUP
1P
UC
WF
VC
VN
N
F
VV
O
F
O
WP
BR
W
VO
VC
N
1
O
U
U
N
N
V
V
P
F
PF_BUS
1 3 CN27 N_BUS
CN24 FG
+15
CN23 GN
D
GW
SMPS GB
G
15
G
U
V
15
15
15
+15
GN
D CN4 CN5 CN6 CN3 CN1
CN25 CN26 CN21 CN22 +15
GN
D
+15
GATE BOARD
GN
N
P
PW1
PW2
GN
D
F
D
PGM
- 15
+15
+15
+24
GN
CM
D
+5
PW2
PW1
GN
D
P
F
N
P
P HCT
I1 HCT
CN4 CN10 CN15 CN2 CN14 HCT COM
N HCT
HCT COM
P HCT
I2 HCT
HCT COM
N HCT
MAIN BOARD CN3
P HCT
I3 HCT
HCT COM
N HCT
HCT COM
TB2 TB1
PPG
PG
A
P
B
MP
4-23