OTE 20% %

ppm BOD 30 ppm


ppm NH3 10 ppm
SCFM 132.325 f3/min

T 32 F
p 10 psia
ACFM 181.2552 f3/min
DOi 1.5 g/m3
DOf 5 g/m3
T 20 C
Flowrate 3800 m3/d
0.043981 m3/s
Oxygen Transfer Efficiency 6%
Cs at 20C 9.09 g/m3 Cek Appendix E

Qa 0.014543 m3/s
0.872566 m3/min
872.566 L/min

DOi 0 g/m3
DOf 5 g/m3
T 30 C
Flowrate 5 m3/d
5.787E-05 m3/s
Oxygen Transfer Efficiency 7%
Cs at 30C 8 g/m3 Cek Appendix E

Qa 1.806E-05 m3/s
0.001084 m3/min
1.083847 L/min
Q 16 m3/d
BOD5 30 mg/L
BOD5 final 12 mg/L
BOD5/BOD L 0.68
Thoritical O2 requirement 0.423529 kg/d

Csw at 20C 9.15 mg/L


C'sw at 30C 7.63 mg/L From table?
C 1.5 mg/L min DO required
https://www.sci-hub.ren/https://www.jstor.org/stable/25036815
Rr=0

Q 0.595238 cfm 0.016667 m3/min waste effluent flow


16 m3/day
D0 8 mg/L 8 mg/L Csw-C0, initial DO deficit related to intial DO concentratio
D 3 mg/L 3 mg/L Csw-C, final required DO deficit related to the final DO co
Ca 0.5 0.5 constant for a specified aeration diffusion unit
H 3.937008 ft 1.2 m liquid depth
Ga 1.428571 scfm 0.04 m3/min air-flow rate/air diffuser unit
2.4 m3/h
n 0.1 0.1
θ 1.024 1.024 1.024; temperature correction coefficient for Kla for a bub
T 30 C 30 C design temperature
β 0.95 0.95 aerator spacing correction factor, close to 1.0
α 0.85 0.85 ratio of the oxygen-transfer coefficient of the waste efflue
Nu 0.331881 units 0.512494 units number of dffuser
d to intial DO concentration
related to the final DO concentration
n diffusion unit

coefficient for Kla for a bubble aeration system

or, close to 1.0


efficient of the waste effluent to water
Aeration time 24 hr
Tank volume 3.2 m3
Flowrate 3.2 m3/day