Q1. Determine The Absorber Plate Surface Temperature Along The Center Line Between The Tubes at A
Q1. Determine The Absorber Plate Surface Temperature Along The Center Line Between The Tubes at A
Q1. Determine The Absorber Plate Surface Temperature Along The Center Line Between The Tubes at A
Q1. Determine the absorber plate surface temperature along the center line between the tubes at a
distance 0.5 m and 1.0 m respectively from the flow inlet end of a flat plate collector. The
specifications of collector are as follows:
Length of absorber plate along flow direction (L) 2m
Thickness of absorber plate (δ) 0.5 mm
Thermal conductivity of absorber plate (copper) 385 W/m°C
Tube spacing (W) 150 mm
Tube outside diameter (D) 15 mm
Overall loss coefficient (UL) 8.0 W/m2°C
Solar radiation absorbed by the absorber plate (S) 700 W/m2
Ambient temperature (Ta) 20°C
Absorber plate temperature above the fluid tubes at a distance 0.5 m and 30°C and 35°C respectively
1.0 m from the flow inlet end (Tb)
Q2. Determine the collector efficiency factor for a flat plate collector having the following
specifications:
Thickness of absorber plate (δ) 0.5 mm
Thermal conductivity of absorber plate (copper) 390 W/m°C
Tube spacing (W) 150 mm
Tube outside diameter (D) 15 mm
Tube inside diameter (Di) 10 mm
Thermal conductivity of tube (SS) 14 W/m°C
Overall loss coefficient (UL) 10 W/m2°C
Heat transfer coefficient inside the tube surface (hfi) 325 W/m2°C
Brazing resistance between the tube and absorber plate may be assumed to be negligible.
Ans: 0.818
Q1: Determine the absorber plate surface temperature along the center line between the tubes at a
distance 0.5 m and 1.0 m respectively from the flow inlet end of a flat plate collector. The specifications
of collector are as follows:
Length of absorber plate along flow direction (L) 2m
Thickness of absorber plate (δ) 0.5 mm
Thermal conductivity of absorber plate (copper) 385 W/m°C
Tube spacing (W) 150 mm
Tube outside diameter (D) 15 mm
Overall loss coefficient (UL) 8.0 W/m2°C
Solar radiation absorbed by the absorber plate (S) 700 W/m2
Ambient temperature (Ta) 20°C
Absorber plate temperature above the fluid tubes at a distance 0.5 m and 30°C and 35°C respectively
1.0 m from the flow inlet end (Tb)
solution
y
Temperature distribution on the plate between the tubes is
given by: x Tb
c
T
𝑇 − 𝑇𝑎 − 𝑆/𝑈𝐿 cosh(𝑚𝑥) Y
e
= Eq. (1) a b d
𝑇𝑏 − 𝑇𝑎 − 𝑆/𝑈𝐿 cosh[𝑚(𝑊 − 𝐷)/2] y
𝑇 − 20 − 700/8 cosh(6.45 × 0)
= Eq. (2)
𝑇𝑏 − 20 − 700/8 cosh[6.45 × (0.15 − 0.015)/2]
Brazing resistance between the tube and absorber plate may be assumed to be negligible.
solution
tanh[𝑚(𝑊 − 𝐷)/2] 𝑈𝐿 8
𝐹= ,where𝑚 = √ = √ = 6.45
[𝑚(𝑊 − 𝐷)/2] 𝑘𝛿 385 × 0.5 × 10−3
tanh[6.45(0.15 − 0.015)/2]
∴ 𝐹= = 0.941
[6.45(0.15 − 0.015)/2]
𝐹1 = 0.842(𝐀𝐧𝐬)