Power Plant Solar Panel: Making The Conventional, Exceptional

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

 

              
 
 

              |   495 W
   

Power Plant Solar Panel


SunPower Performance Panels wrap conventional front contact cells with 35 years of
SunPower materials, engineering and manufacturing expertise to enhance panel
strength and durability. The weakest points of Conventional Panel design are
eliminated to deliver superior power, reliability and value.1

Limited Product Availability:  Performance P3-UPP panels are engineered to meet


the unique needs of large-scale solar power plants. Please note that this product is
built-to-order for large-scale, multi-megawatt installations only. Please contact your
sales representative with further questions.

More Energy
By exposing more active surface area across more mono PERC cells,

 
Performance P3-UPP panels optimize power density, while lowering
         system costs. The result is a high power panel uniquely suited for the
needs of power plant developers, maximizing energy production within
available space.

Trusted Durability
SunPower Performance panels are engineered to withstand a host of
Making the conventional, environmental challenges, such as daily temperature swings, high
exceptional humidity and shading. In the case of shading, the unique parallel
circuitry of Performance panels maximizes energy production during
morning and evening row-to-row shading, or when panels become
soiled.  

Conventional Performance Panels

 Redundant cell connections create


flexible paths for continuous
electricity flow. Shade or soiling Shade or soiling

 Aerospace-grade conductive adhesive


delivers superior durability.
Proven Reliability
 A proprietary encapsulant minimizes
An innovative shingled cell design mitigates the leading reliability
cell degradation from environmental
exposure. challenges associated with conventional front contact panels by
designing out fragile ribbons and solder bonds on the cells. SunPower
 Smaller cells extend panel life,
  stands behind each Performance panel with a comprehensive 25-year
optimizing current to keep cells
cooler when shaded. 3
power and product warranty. With proven results in real-world
 
conditions, SunPower Performance Panels have become the most

  deployed shingled solar panel in the world.2


 
                     

 
sunpower.com
  | 495 W Power Plant Solar Panel - Preliminary datasheet
 
Electrical Data
  Model SPR-P3-500-UPP SPR-P3-495-UPP SPR-P3-490-UPP SPR-P3-485-UPP SPR-P3-480-UPP SPR-P3-475-UPP
Nominal Power (Pnom) 4
500 W 495 W 490 W 485 W 480 W 475 W
  Power Tolerance +5/–0% +5/–0% +5/–0% +5/–0% +5/–0% +5/–0%
Efficiency 20.9% 20.7% 20.5% 20.2% 20.0% 19.8%
  Rated Voltage (Vmpp) 45.6 V 45.2 V 44.9 V 44.6 V 44.3 V 43.9 V
Rated Current (Impp) 10.98 A 10.95 A 10.92 A 10.89 A 10.85 A 10.83 A
  Open-Circuit Voltage (Voc) 54.6 V 54.2 V 53.9 V 53.6 V 53.3 V 53.0 V
Short-Circuit Current (Isc) 11.63 A 11.60 A 11.57 A 11.53 A 11.49 A 11.46 A
  Maximum System Voltage 1500 V IEC
Maximum Series Fuse 20 A
  Power Temp. Coef. −0.34% / ° C
Voltage Temp. Coef. −0.28% / ° C
  Current Temp. Coef. 0.06% / ° C

Tests And Certifications (Pending) Operating Condition And Mechanical Data


  Standard Tests5 IEC 61215, IEC 61730 Rated to 1500 V Temperature –40° C to +85° C
Quality Certs ISO 9001:2008, ISO 14001:2004 Impact Resistance 25 mm diameter hail at 23 m/s
  EHS Compliance OHSAS 18001:2007, Recycling Scheme Solar Cells Monocrystalline PERC
Ammonia Test IEC 62716 Tempered Glass High-transmission tempered anti-reflective
Desert Test MIL-STD-810G Junction Box IP-67, MC4 Compatible, 3 bypass diodes
Salt Spray Test IEC 61701 (maximum severity) Weight 25 kg
IEC 61215 (MQT 23.1 LeTID detection) draft     Wind: 2400 Pa, 245 kg/m² front & back
LeTID Test6 Max. Load
standard Snow: 5400 Pa, 550 kg/m² front
PID Test Potential-Induced Degradation free: 1500 V Frame Class 2 silver anodized
Available Listings TUV, MCS
 
2066 mm 35 mm
Warranties
25-year Product Workmanship Warranty
25-year Power Warranty
A
(Please refer to product warranty for details)
527040

• Installation should only be done by a qualified technician.


• Solar module has full voltage even in very low light.

Field Wiring: Cu wiring only, min. 12 AWG/4 mm2, insulated for 90° C min.
Suitable for ungrounded, positive, or negative grounded DC systems
1

Maximum Series Fuse


Short-Circuit Current (Isc)
Open-Circuit Voltage (Voc)
Current (Imp)
Voltage (Vmp)
Rated Power (Pmax)1 (+5/ 0 %)
MODEL: SPR-P19-410-COM
Standard Test Conditions: 1000 W/m2, AM 1.5, 25° C

1160 mm A
SEVERE ELECTRICAL HAZARD
Patented as shown at www.sunpower.com/patents

WARNING
www.sunpower.com

15
9.94
53.1
9.35
43.9
410
W
A
A
V
A
V
Max. System Voltage:1500 V DC
Fire Rating: Class C
Safety Class II

FRAME PROFILE

35 mm

1 Independent Shade Study by CFV Laboratory. (B)


2 Osborne. "SunPower supplying P-Series modules to a 125 MW NextEra
project." PV-Tech.org. March 2017.
3 SunPower Performance Series – Thermal Performance, Z.Campeau 2016. (A) Cable Length: 1000 mm +/-15 mm
4 Measured at Standard Test Conditions (STC): irradiance of 1000 W/m², AM
(B) Long Side: 32 mm
1.5, and cell temperature 25° C.
Short Side: 24 mm
5 Class C fire rating per IEC 61730.
6 Fraunhofer CSP LID Sensitivity according to IEC 61215 (MQT 23.1 LeTID
detection), <1% power loss. Read safety and installation instructions before using this product.

Designed in USA, assembled in China.

See www.sunpower.com for more reference information.


Specifications included in this datasheet are subject to change without notice.
 
©2020 SunPower Corporation. All rights reserved. SUNPOWER and the
SUNPOWER logo are registered trademarks of SunPower Corporation in
Europe, the U.S., and other countries as well.
534985 REV A / A4_EN
Publication Date: June 2020
  00 800 855 81111
©2018 SunPower Corporation. All rights reserved.

sunpower.com

You might also like