HS500 User Manual.V110.en
HS500 User Manual.V110.en
HS500 User Manual.V110.en
10
HS-500
ARL-500 REMOTE ACCESS TERMINAL
USER MANUAL
HS500 User Manual V1.10
This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all
of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the
right to make changes and improvements to any of the products described in this document without prior notice.
Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
HS500 User Manual V1.10
1. GENERAL DESCRIPTION
The HS500(ARL Universal Keypad) is a handheld terminal which can be connected to the system from any point on the
CANbus (in the car, on the car top, at landings or from control panel), in a way, enables you to operate all control functions of
the ARL-500 controller for installation and maintenance independent of location.
2. OVERVIEW
The HS500’s user interface consists of 9-key keypad and 128x64 pixel graphic LCD. 6 keys are used for remote operating of
ARL-500 controller in the same way as keypad on ARL-500 controller. The other 3 keys (F1, F2, F3) are additional function
keys and reserved for future using.
After connecting the HS500 to the system, ARL-500 controller’s menu is shown simultaneously on handheld terminal display.
In this way, the elevator system can be operated by keypad & menu simultaneously on ARL-500 controller and on ARL
Universal Keypad.
4. KEYPAD OPERATION
The ARL-500 controller is operated by using 6-key keypad. The basic functions of keys according to screen are described
in the tables below. A detailed description of the operation as well as the menu navigation is explained in the
programming manual of the ARL-500.
Key functions in the main screen
or To previous/next monitoring screens
Open service options screen
Open manual command screen
Open main menu
Back to main screen
Press LEFT key on main screen in order to activate the “ADrive screen” and so the display of the ADrive inverter is simulated
on the ARL-500 display. It is one of the status screens and can be switched by LEFT/RIGHT keys.
In this screen first you have to select the usage of keypad either commanding to the ARL-500 or ADrive. When activating
“6. ADrive screen” the keypad still operates the ARL-500 and it must be changed to ADrive.
Press UP+DOWN keys simultaneously on this screen in order to enable operating ADrive by keypad. By pressing UP+DOWN
keys the keypad control is switched between ARL-500 and ADrive.
ADrive screen
In this status screen ARL-500 keys have the following functions for operating the ADrive:
ARL-500 key ADrive key
In order to exit this screen you have to set keypad control to ARL-500.
Parameter code
CT Unidrive Screen
Parameter value