Are Uncontrollable Humidity Problems Costing You A Bundle?: Hot Gas Reheat Option
Are Uncontrollable Humidity Problems Costing You A Bundle?: Hot Gas Reheat Option
Are Uncontrollable Humidity Problems Costing You A Bundle?: Hot Gas Reheat Option
Computer Rooms
Table of Contents
Inspection..........................................................................................................................2
Application........................................................................................................................2
HR Water Piping...............................................................................................................3
Typical Installation..........................................................................................................3
Installation Start-Up.......................................................................................................4
Electrical Diagram...........................................................................................................4
MODEL NOMENCLATURE
HR OO1 -1
HEAT EXCHANGER
DESIGNATOR
FORWARD: based on reduced loads thus the ability to heat hot water is
also reduced. This same result could be noticeable on units
The complete instruction manual should be read carefully
that are over sized for the served loads thus resulting in
before beginning installation. Follow the instructions
short cycling of the heat pump and HRP package.
precisely to insure proper operation of the system.
The instructions are to be left with the homeowner for The HRP is equipped with a LGL (low discharge gas limit)
future reference if needed. All local, state and national that disables the HRP pump from operating until discharge
codes supercede these instructions and must be strictly gas temperatures are above the required levels to insure
adhered to. proper operation. This eliminates the possibility of actually
absorbing heat from the water in the hot water tank. This
UNCRATING AND INSPECTION: safety feature could also reduce HRP run time and further
diminish HRP performance.
Check for shipping damage, both visible and concealed if
there exists any indication of damage immediately file a
claim with the shipping company. You are the only one to FIELD MOUNTING EM/EC SERIES HR KIT:
file a claim regardless of why the damage was incurred or It is recommended that the heat recovery package be
by whom. Remove the access cover and check all of the factory mounted at the time the heat pump is purchased.
components parts to make sure they are properly secured This eliminates field intrusion into the refrigeration circuit
before installing the unit. Parts broken loose from their of the heat pump and the associated problems that may
secured position with resultant damage is considered arise. If the heat recovery package is to be field installed the
damage during shipment. following steps must occur:
TYPICAL CONNECTION
DIAGRAM FOR
EM/EC SERIES
TYPICAL CONNECTION
DIAGRAM FOR EV/ES, AU, AP,
GT/GS SERIES WITH
INTERNAL HRP
(Figure #3)
6. Cut the hot gas discharge line between the compressor 5. Once drained the tank should be flushed with cold water
discharge port and the reversing valve inlet. Connect the until the water leaving the drain hose is clear and free of
discharge line from the compressor to the line marked sediment.
“Refrigerant in” on the heat recovery coil. Connect the
6. Close all valves and remove the drain hose.
line marked “Refrigerant out” of the heat recovery coil to
the reversing valve inlet line. (Figure #2) 7. Install HR water piping.
7. Make the wiring connections from the heat recovery NOTE: Use of Heat Recovery Packages with Smart Hot Water
package to the compressor contactor as shown. Tanks is not recommended.
(Figure #4)
Application of a Heat Recovery Package with a “Smart” electric
8. It is imperative that the refrigerant system remain clean hot water tank may cause nuisance fault errors in the tank’s
and dry during the above operations. If there is doubt of on-board diagnostics. In operation, a Heat Recovery Package
this a bi-flow liquid line dryer must be installed. can raise the water temperature in the hot water tank, even if
9. Evacuate the unit and recharge according to unit the tank’s on-board system is not calling for heat from the
nameplate. tank’s internal heater elements. This rise in tank water
temperature while the tank is idle may be interpreted as a
WARNING: If heat recovery unit is installed in an area where heater element that is stuck “on” by a smart tank’s diagnostic
freezing may occur the unit must be drained during winter system.
months to prevent heat exchanger damage. Heat exchanger
ruptures that occur due to freezing will void the heat recovery If this occurs, the Heat Recovery Package may need to be
package warranty along with the heat pump warranty. turned off at the heat pump.
Low Heat Output Scaled or fouled heat exchanger Clean heat exchanger