Discussion On Improving Marine Boiler Efficiency On Board
Discussion On Improving Marine Boiler Efficiency On Board
Discussion On Improving Marine Boiler Efficiency On Board
Abstract. Marine boiler is one of the most important systems on board which is used to produce
steam to drive the main engines or auxiliary machinery. Steam demand is the main criteria of
operating a boiler at a given load for marine boilers. It is of importance that boilers cannot be
overloaded to achieve excessive output and ensure all the parameters are within the safety limits.
Therefore, some important do’s and don’ts must be followed which marine engineers must know on
operating a marine boiler in a safe and efficient manner.
Introduction
On modern society, vessels play a critical role in world’s transportation and high-modernized and
high-automated ships have become the world’s trend. Therefore, the advanced technologies are
used and advanced devices are provided on board. In addition, researchers are more and more
concerning about the environmental protection and resources saving in shipbuilding. With the
recent technical development of shipping industry, ships which are capable of reducing energy
consumption and enhancing the operation efficiency are more popular all around the world. Marine
boiler is such an important application in ship’s engine room that needs special attention,
considering the fact that it supports several other operations and machinery, including the main
engine, auxiliary machinery, etc. Maintaining and improving boiler efficiency requires taking note
of a number of factors, for example, following the correct operating procedures, checking
associated valves and so on. Researches on improving marine boiler efficiency have been received
much more attention in recent years. However, marine boiler may cause severe damage to the safety
of property and even to the human’s lives if it is operated improperly. Crews on board know that the
dangers of high-temperature steam and they must be careful while operating and maintaining the
boilers. According to the reference data, one of the main reasons why such vital accident would
occur is that the improper operating procedures and ignoring the safety precautions. Each of
engineers on board is concerning that all the machinery and systems in engine room can be
available and maximize efficiency without potential safety hazard.
dampers, e.g. fuel line valves, steam valves and safety valves, are in good order. Quick-closing
valves and safety valves should be correctly operational as well. In addition, one of most important
part needs to be examined is the furnace. Check the furnace for refractory deterioration and fuel
dripping near the burner assembly. If any defect is found, it should be rectified as soon as possible.
Cleaning and Maintaining
In order to make the boiler have a good performance, cleaning and maintaining work is
necessary. Measures mentioned below are some common ones to improve boiler efficiency. Scum
valve should be opened to discharge floating impurities and scum regularly and blow down should
be performed once a day to keep the chloride level minimum. Soot blowers should be used to
perform blowing soot since it can assist to continue the heat exchanging ability of the boiler tubes.
On the other side, soot blowing is a precaution against fire. Lubricating is a good and effective
measure in maintaining the boiler so that all the required parts and connections should be lubricated
and greased at regular intervals. Besides, steam system in boiler is prone to leakages because of
fluctuating steam pressure. It is necessary to attend all the leakages as soon as possible to maintain
the efficiency at all times.
Safety Precautions
For the safety reason, it is essential for the engineers to know the safety measures which mostly
described in the company Safety Management System. For example, emergency shut down of the
boiler, which is located in the ECR, should be checked whether it is functional or not. Marine boiler
is oil-fired, high-pressure device with its own fire fighting apparatus. The crew on board should be
aware of application method of local fire extinguisher (foam type). In addition, fire drill needs to be
carried out periodically to prevent accidents.
Apart from measures and operations mentioned above, there are other points that need to be paid
attention in boiler operation.
Don’ts in Boiler Operation
Starting Failure
Never let the inexperienced engineer and untrained operator light up the boiler, especially from
the cold condition. If the boiler is started but failed 3 times, trouble should be traced prior to another
starting. Important points, e.g. pre and post surging, correct starting operating, should be observed.
In addition, abnormal conditions in the boiler should be observed carefully in terms of sound,
smoke, flame quality, drum level and other parameters. Any abnormalities are found; correct them
as soon as possible.
Avoiding Actions
Never operate a soot blower when the boiler is at a high load. Never do the blow down
excessively since the feed water system will add cool water to the boiler drum which will reduce the
thermal efficiency and stress in the boiler. Never operate the boiler at a higher load as a regular
practice. Occasionally, boiler can be overloaded because of excess demand; however, frequent
overload will lead to high stress and tube failure. Never operate the boiler when there is leakage in
any water tube and rectify the failure at the earliest. Never supply sea water in any condition. If the
cascade is filled with sea water because of heavy leakage in the condenser, secure the equipment
and correct the problem.
Periodic Maintenance
Watch out the water level at regular intervals instead of relying on the water level indicator
which is located in the ECR. Keep a close watch to get the real and clear level by the local glass
gauge. Keep the furnace door of the boiler closed in normal condition. The door can be opened to
do cleaning and inspection work for the burner or furnace. Once the work is done, the furnace door
will be closed. In addition, periodic maintenance work is critical for the boiler and boiler auxiliaries
and fittings as the boiler efficiency will be much reduced if the maintenance work is not carried out
over a period of time.
The above mentioned do’s and don’ts provide a general overview to ensure that boiler efficiency is
maintained while the safety aspect is kept intact.
908
Advances in Intelligent Systems Research, volume 156
909
Advances in Intelligent Systems Research, volume 156
Boiler Loading
Boiler loading should be maintained within a correct range, neither too high nor too low. The
optimum range to obtain the highest efficiency is 2/3 of the full load. If it falls below half of the full
load, more air is required to burn the fuel which can increase of the heat loss. Therefore, avoid
operate the boiler below 25% load because the efficiency will be much reduced. Keep the load at
the 2/3 of the full load.
Conclusion
Marine boiler is a device that requires a lot of attention to achieve the maximum efficiency. There
are a number of measures to achieve the efficiency. In the previous passages, some do’s and don’ts
and suggestions about boiler efficiency have been discussed. Apart from suggestions above
mentioned, it is certain that there are other measures need to be taken. In conclusion, correct
operation is the essential step to run the boiler. The operator is required to have the professional
knowledge to operate the boiler. Keep a check on the various important parts and systems and do
the cleaning and maintaining work play a crucial role in obtaining the boiler efficiency. Feed water
temperature and level control, supply air/steam to burner, important parameters and parts and
systems, boiler loading, etc. are common factors need to be controlled strictly and carefully. It is
therefore necessary for the engineers to do the check and cleaning work according to the instruction
manual. During boiler operation, safety precautions need to be taken to avoid potential accidents
and hazards.
References
[1] Cen Kefa. Science of Advanced Combustion [C]. Hangzhou: Zhejiang University Press, 2002.
33-57.
[2] Beltrame, A, Porshnev, P, et al. Soot and NO formation in Methane-Oxygen Enriched Diffusion
Flame [J], Combustion and Flame, 2001, 124: 295-310.
[3] Jia Hongxiang. Heat transfer in Boiler Furnace[M]. Xi’an: Xi’an Jiaotong University Press,
1988.
[4] Liu Hongru, Wan Longjun, Xu yiqun. Research On Simulation of Marine Auxiliary Boiler
System [J], Mechanical & Electrical Engineering Technology, 2015, 44(7) 89-91.
[5] Zhao You. Analysis of the Method of Improving the Thermal Efficiency of Marine Auxiliary
Boiler [J], Science and Technology & Innovation, 2015, 13, 144-146.
[6] Yang Zhiyun, Zhou Guoyi,et al. The Experimental System and Analytical Method of the
Flue-gas Filter used on a Marine Supercharged Boiler [J], Ship Marine Engineering, 2006, 2,
25-27.
[7] R.S. Virdi, D.G. Thakur. Investigation and Analysis of High Temperature Corrosion and
Degradation of Marine Boiler Combustion Swirler [J], Journal of Marine Science and
Application, 2016, 15(1) 86-94
[8] Zzhang Lixiang. The Boiler Steam Temperature Fuzzy-adaptation PI Control System Intelligent
Control and Automation, 2000. Proceedings of the 3rd World Congress On Volume, July,
2000.
910