Ericsson AXE 810

Switch (ROTD)
APZ APZ 212 33 C *
APG APG 40
Quantity STM-1 12
Software version R10
Quantity of recks 5 x standard racks of new type Ericsson
GSMSC (Gateway Short Message Service Center ) – HLR
GMSC incl. HLR and (Home Location Register), AUC (Authentication Center), 127
AUC X C7 (CCITT7) narrow-band interfaces and announcement
boards
48 Volt Emerson distribution rack (fuses)
*Detailed specification of APZ 212 33 C is on the page 4

Switch is completely assembled and perfectly functional. It has being hold in


standby as reserve. Power off is planned on end of January 2011. System includes:
complete set of uncut cabling. There is an option to visit working station onsite.

Offer is valid until the end of January 2011.


Price (FOB Rotterdam) CALL

Mr.F.Bordewijklaan 7 Tel: +31 (0)30 8783777 www.euronetix.nl VAT No. NL243666494B01


2343 KS, Oegstgeest Tel: +31 (0)30 3020077 [email protected] Comp.Reg. 27327383
The Netherlands
Mr.F.Bordewijklaan 7 Tel: +31 (0)30 8783777 www.euronetix.nl VAT No. NL243666494B01
2343 KS, Oegstgeest Tel: +31 (0)30 3020077 [email protected] Comp.Reg. 27327383
The Netherlands
An example of handling prior to the shipment:

1.The load distributed on reinforced pallet 4. Ply-wood (12mm) screwd on woden frame

2. Racks are tighten together

3. Racks are cushioned and foiled 5. Cables are labeled and boxed apart

Mr.F.Bordewijklaan 7 Tel: +31 (0)30 8783777 www.euronetix.nl VAT No. NL243666494B01


2343 KS, Oegstgeest Tel: +31 (0)30 3020077 [email protected] Comp.Reg. 27327383
The Netherlands
Function Part number Rev Quantity
DLHB Digital Link Handling Board ROJ 204 06/1 R1C 14
RP4-H Regional Processor 4 – Half Height ROJ 204 507/1 R6J 18
PDSPL2E Pooled Digital Signaling Platform Loadable ROJ 204 32/1 R1A 10
PCD-G Pulse Code Devices-Generic Board ROJ 204 29/1 R1A 2
M-AST 8H ROJ 204 30/2 R5A 4
SP/LBB/LN/C13 APG 40 (Adjunct Processor Group) BFB 109 51/2 R4A 2
FAN UNIT BFD 509 08/4 R1G 7
FAN UNIT BFD 509 08/3 R1C 6
RPBI-S Regional Processor Bus Interface ROJ 208 436/1 R1B 2
IPNAX IPN Interface Board ROJ 208 435/1 R2A 2
POWC Power Control Unit ROJ 208 437/1 R1B 2
SPU Signal Processor Unit ROJ 208 438/1 R1A 2
IPU Instruction Processor Unit ROJ 208 439/1 R1A 2
DSU-2GW Data Storage Unit ROJ 208 445/1 R1A 4
MAU Maintenance Unit ROJ 208 442/1 R1B 1
ETC5 Exchange Terminal Circuit ROJ 204 03/1 R3B 2
TTA-1 ROJ 204 014/1 R1B 2
SCB-RP Support and Connection Board with RP ROJ 208 323/1 R2G 8
CDB Clock Distribution Board ROJ 208 315/1 R1D 8
IRB Incoming Reference Board ROJ 208 316/1 R2E 2
CL890 CGB Clock Generation Board ROJ 208 314/1 R1D 2
LRB Local Reference Board ROJ 208 317/1 R1E 1
RPP PCI BUS Based Regional Processor ROJ 204 16/6 R1D 4
RPP PCI BUS Based Regional Processor ROJ 204 16/5 R2C 1
EPS Ethernet Packet Switch ROJ 204 50/1 R1B 2
RPG3 Regional Processor with GS interface ROJ 204 43/2 R1H 32
XDB Switching Distributing Board ROJ 208 304/1 R3E 8
CSPB Common Speech Processing Board ROJ 208 351/1 R1C 20
DLEB Digital Link multiplexer for Existing Board ROJ 208 312/1 R2C 8
ET155-1-0 SDH exchange terminal ROJ 208 306/1 R2D 12