Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
292 views
16 pages
3399 1961
Uploaded by
Krishna Teja Vudutha
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download
Save
Save 3399.1961 For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
0 ratings
0% found this document useful (0 votes)
292 views
16 pages
3399 1961
Uploaded by
Krishna Teja Vudutha
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Carousel Previous
Carousel Next
Download
Save
Save 3399.1961 For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
Download
Save 3399.1961 For Later
You are on page 1
/ 16
Search
Fullscreen
BLS. 3399: 1961 of operation at its rated kVA without injury on any tapping and at any applied voltage which does not vary from the voltage for which the tapping is rated by more than plus 5 per cent. SECTION SEVEN: INSULATING MATERIALS GENERAL 701. The recognized insulating materials shall be suitable for use in the service conditions specified in Section Four. soLips 702. Four of the classes of insulating material listed in B.S. 2757*, A, B, H and G, are recognized in this standard for dry-type transformers. For transformers immersed in oil or synthetic liquid, Class A only is recognized. igus 703. a. Oil. Mineral oil, when provided, shall comply with B.S. 148, * Insulating oil for transformers and switchgear" NOTE, Attention is drawn tp the fact that sustained operation of transformers at the maximum temperatures permitted by this standard may cause the oil to deteriorate more rapidly than the other components {see CP 1009 * Maintenance of insulating oil (with special reference to transformers and switchgear)). 4. Synthetic liquids. In the absence of British Standards covering synthetic insulating liquids the provision of such liquids is a matter for arrangement between manufacturer and purchaser. NOTE. Oil and synthetic liquids should not be interchanged. SECTION EIGHT: INSULATION TESTS GENERAL 801. The test voltages shall be as follows: TABLE §. TEST VOLTAGES FOR DRY-TYPE TRANSFORMERS AND OIL-IMMERSED TYPE TRANSFORMERS i | j eee 1 | 2 Rated voltage Power-frequency test voltage kV ms. kV rms. Less than 10 25 to | + 3 33 a NOTE 1. Where the rated voltage of a transformer is an intermediate value, the test voltage should be the next higher valve, NOTE 2. Transformers for use in ships are not designed for impulse testing + B.S. 2757, * Classification of insulating materials for electrical machinery and apparatus ‘on the basis of thermal stability in servic 4BS. 3399: 1961 SECTION NINE: TEMPERATURE RISE LIMITS. crsrmat 901, The terapercmare rises of transformer windings, oil and cares shai 1 nat excoed tive sists specified in Tables 6 and 7, when tested in accorciance Section Eighteen. with Fer water cooled transformers, the temperature rise given is that meassured above the inlet water temperature, For ather types of cooling, the temper ature rises piven are those measured above the temperature of the cooling air. TABLE 6. TEMPERATURE RISE LIMITS FOR DRY-TYPE TRANSFORMERS | | Temperature rise measured by resistance") Cooling Class of Part classification | inenlation - a Gee Table 1) mt | Group 2 she aie ] : dec) ee Windings AN oF AB A 0) | B | 7 5 no | ous us | | x | aa 5 | Gv inert ens | c 45 145 | (Silicone material | a I _ only) _ corer |The empeture ssa in no east such yale tat ere 15 risk of injury to any insulation material on adjacent parts.B.S. 3399 : 1961 = : i d 5 oe ae NOTE. This figure does not purport to show constructional details. Fig. 15. Recommended position of fittings for alr cooled transform ers SECTION SEVENTEE! PERFORMANCE AND TOLERANCES EFFICIENCY 1701. When statements of efficiency are required they shall be based on the loading at the rated KVA and at unity power factor (and other po-wer factors if agreed), and computed in accordance with Appendix E. PERFORMANCE AND TOLERANCES 1702. A transformer complies with this standard when the differences between the measured test results and the figures guaranteed by the manufacturers are not greater than the permitted tolerances. Characteristics which may be subject to guarantees in respect of electrical performance are given in Table 10, in which the tolerances are also stated. The ‘object of these tolerances is to allow for the effect of small manufacturing variations. - The tolerance on voltage ratio shall apply to all tappings, but in a tapped ‘winding having few turns it is permissible, by agreement between manufacturer and purchaser, for the tolerance to apply to the nearest voltage ratio obtainable and not to the specified voltage ratio. The statements of impedance, load losses, no-load losses, efficiency and regulation apply to the principal tapping only. 30BS. 3399 : 1961 TABLF, 10. TOLERANCES ON ELECTRICAL PERFORMANCE: Tolerance Voltage ratio at no load 0.5 por cent of the declared ratio, or a percenta to 1/10th of the percentage impedance voltage at rated load, whichever is the smaller Impedance voltage of |_| On principal tappings transformers 4, Two-winding transformers +t 10 per cent 5. Multi-winding transformers + 15 per cent . ‘Ohmic impedance of series | Minus zero current limiting reactors | Plus 20 per cent of the rated value (see Note 2) ‘ Load losses | Plus 20 per cent of the declared losses No-load loss, Plus 10 per cent of the declared loss Fificiency | In accordance with the tolerance on losses —— | __ — Regulation In accordance with the tolerances on impedance v9 Tage [and toad losses I NOTE 1. A tolerance for no-load current is not specified. NOTE 2. Reactors should be designed to have not less than the specified reactive KWA at the current corresponding to the rated current multiplied by the overcurrent factor. SECTION FIGHTEEN: TESTS CONDITIONS FOR TESTS. 1801. Tests chall be made at the manufacturer's works at room temperature and with all those external components and fittings in place which are likely to affect the performance. i Unless otherwise agreed between the manufacturer and the purchaser and unless the test specifically requires otherwise, windings with tappings shall be © connected on their principal tapping The test basis for all characteristics except insulation is the rated condition unless it is specifically stated otherwise. 31BS, 3399 : 1961 TESTS OF TRANSFORMERS 1802, *a. Routine tests. All transformers shall be subjected to routine tests at the manufacturer's works. The tests shall comprise: 1. Measurement of winding resistance ‘Clause 1804 2. Ratio, polarity and phase relationships ‘Clause 1808. 3. Impedance voltage Clause 1806. 4, Load losses Clause 1807. 5, No-load losses and no-load current Clause 1808. 6, Insulation resistance Clause 1809. 7, Induced over-voltage withstand Clause 1810. 8, Separate-source voltage withstand Clause 1811. *b. Type test, In addition to the routine tests, the following type test may be made if ordered by the purchaser: ‘Temperature rise test Clause 1812. Where the purchaser desires evidence corresponding to the temperature rise test in lieu of actual tests, the manufacturer may submit records of tests on a transformer which, in essential details, is representative of the one being purchased. Test ceRriicates 1803. Where required by the purchaser, a certificate of all tests made on the transformer shall be provided by the manufacturer. In the case of three-winding transformers test certificates shall give the actual measurements and also the derived values for losses, impedance voltages and regulations, for stated loading conditions. MEASUREMENT OF WINDING RESISTANCE 1804. The resistance of each winding, and the terminals between which it is measured shall be recorded. When measuring the initial resistances, care shall be taken to determine the temperature of the windings. The temperature at which the measurement is made shall be recorded. In all resistance measurements, care shall be taken that the inductive effects are reduced to a minimum. The induction time for the measuring current to become constant should be noted during the cold resistance measurements in order to give guidance when hot resistance measurements are made luring any subsequent tests, e.g, temperature rise tests, so that sufficient time is aallowed for the inductive effect to disappear before the hot resistance readings are recorded. a. Dry-type transformers. The temperature recorded shall be the average teading of several thermometers placed on the winding surface. * IC tests a and b are required to be made at the manufacturer's works in the presence of the purchaser, this should be stated by the purchaser. 22BS. 3309) ‘The initial resistance and initial temperature of the winding shall be measvured at the same time, and the temperature of the winding as measured by thermo- meter before beginning the test should approximate to that of the surrounding medium, b. Oil-immersed type transformers. Before recording the initial resistance and the oil temperature the transformer shall have been under oil without excit ation or load for not less than 3 hours The temperature of the winding shall be taken to be the same as the effective average oil temperature determined as in Sub-clause 181 RATIO MEASUPEMENT, CHECK OF POLARITY AND PHASE RELATIONSII" 1805, ‘The tucrs ratio shall be measured on each tapping, and the polarity and phase éelationships shall be checked! MEASUREMENT OF IMPEDANCE VOLTAGE 4806, Tre in:pedance voltage shall be measured at rated frequency usimg an approximately sinusoidal supply. The measurement may be made at any current not less than one-half rated current and the value so obtained shall be increased in the ratic of the rated current to the test current, The impedance voltage may be measured at any convenient temperature but the test results shall be corrected to the appropriate reference temperature detailed in Table 11 On three-winding transformers, the impedance voltages shall be measured between the windings taken in pairs as shown below a. between higher voltage and intermediate voltage windings, b. between intermediate voltage and lower voltage windings. ¢. between lower voltage and higher voltage windings. For transformers with more than three windings, the windings shall be taken in pairs and the principle established above for three-winding transformers. shall be followed, MEASUREMENT OF LOAD LOSS 1807. ‘The load loss shall comprise the sum of the J4R loss in the windings cleter- mined from their resistances and the currents flowing, plus all stray losses: due to eddy currents and to the leakage fx between windings. On a ewo-winding transformer the sum of the components taken ingettier may be measwed by a wattmeter or other suitable means by applying 1 one winding the voltaze required at rated frequency to produce in it rated current, the ather winsting being short-circuited during this test. a 1961BSS. 3399 : 1961 ‘The measurement shall be made at any current not less than one-half rated current. The value s0 obtained shall be corrected to the value at rated current by multiplying it by the square of the ratio of the rated current to the test current. ‘The losses measured by the above method include the core loss corressponding to the impedance voltage, and such core loss may be deducted frome the total short-circuit losses in order to determine more exactly the true load lossses. This core loss may be determined by measuring the no-load loss with an applied voltage equal to that used in the load-loss test. On a three- (or more) winding transformer, three (or more) separate load- oss measurements shall be made corresponding to the three (or more) measure- ments of impedance voltages, ‘The load loss may be measured at any convenient temperature, but the test results shall be corrected to the appropriate reference temperature on the assumption that the /*R loss varies with the temperature directly as the. variation in resistance, and that the stray loss varies with temperature inversely asthe variation in resistance. The reference temperature to which correction is made shall be as given in Table 11. TABLE 11, REFERENCE TEMPERATURES (Class of insulation sed Reference temperature A 18°C B 95°C Hin air 140°C in inert gas 170°C C Gsilicone materials only) 170°C MEASUREMENT OF NO-LOAD LOSSES AND NO-LOAD CURRENT 1808, The no-load loss shall comprise the following: Tem a. Core loss, including the stray losses du to the excitation current. b. Dielectric oss. ¢. PR loss due to the excitation current. The no-load losses shall be measured at rated frequency with the rated voltage applied to one winding, the other windings being open-circusited. The no-load current shall be recorded. For all normal transformers (except 3-phase transformers without ainy delta~ connected winding) the voltage shall be set by reference to an instrument actuated by the mean value of the voltage wave between fines, but scaled to read the rms. value of that sinusoidal wave having the same mean value. 4Rs. uy For three-phase transformers without any delta-connected winding, the no-load losses shall be measured at the r.m.s. voltage indicated by an instrurnent actuated by the rm.s. value of the voltage wave. In this ease a supply sha I! be used in which the wave-form of the supply voltage is stich that the sum off the Sth and 7th harmonic voltages of the supply is not greater than 5 per cent of the rm.s, value of the voltage supplied. MEASUREMENT OF INSULATION RESISTANCE 1809. The insulation resistance of each winding in turn to all the other windings, core and frame or tank connected together and to earth shall he measured and recorded, The oil and winding temperature shall be measured immediately before the test and recorded YINDUCFD OVERVOLTAGE WITHSTAND TEST 1810. To test between turns, coils and terminals of windings aii alterna ting voltage shall be applied corresponding to twice the voltage appearing, between these parts when rated voltage is applied to the terminals. ‘The duration of the test shall be 60 seconds for any test frequency up to and including twice the rated frequency. When the test frequency exceeds twice the Tated frequency, the durstion of the test in seconds shall be 60 times twice the Tated frequency divided by the test frequency, or 15 seconds, whichever is the greater, SFPARATE-SOURCE VOLTAGE WITHSTAND TEST 2813. Tho eeparate-source voltage test shall be made with single-phase alte ena ing vollage as nearly as possible of sine-wave form and of any conven ient frequency noc iess than 25 c's, The rm.s. or peak value of the applied voltage shall be measured. The ems value, or the peak value divided by 4/2, shall be in accordance with Table 5. The appropriate voltage obtained from a separate source shall be applic«l for ‘61 seconds fo each winding in turn, between the winding under test and. the remaining windings, core, frame and tank or casing of the transformer, connected together and to earth. The test shall be commenced at a voltage of not greater than one-third of the test value end shall be increased to the specified value as rapidly as is consistent with its magnitude being indicated by the measuring instrument. At the enel of the test the voltage shall be reduced rapiclly to less than one-third of its full value before switching of, TEST OF TEMPERATURE Rist BES. The tests may be made at any air temperature not exceeding 45°C or water tempereture not exceeding 30°C as appropriate x 1961BS. 3399: 1961 For oilsimmersed transformers, the temperature of the oil shall be measured by a thermometer placed in the thermometer pocket. ‘The winding temperature shall be ascertained by means of the resistance ‘method when the windings have a resistance of 0-005 ohm or greater. Practical difficulties due to the short time available for the measurement of hot resistances may prejudice the accuracy of such measurement with.in about 1 per cent. For measurements having a value less than 0-005 ohm, the resistance methods may be inaccurate. In such cases, the temperature rise at the end of a temaperature test shall be determined as follows: 1. Dry-type transformers. The surface temperature shall be mea sured by placing a thermometer at the hottest accessible point® and the temmperature rise, so measured, multiplied by a factor of 0°75 shall not exceed the limiting value of Table 6. 2. Oi-immersed type transformers. The temperature of the oil shall be measured by a thermometer placed in the thermometer pocket. The tempera~ ture rise so determined shall not exceed the limiting value for oil given in Table 7. a, Thermometer method of measurement. Thermometers containing mercury shall not be used in places where there is a magnetic field that is varying in intensity or moving in space. . Resistance method of measurement. The temperature of a windin g (7;) at the end of a test period shall be calculated from its measured resistance (Ry) at that temperature and its measured resistance (R,) at some other temperature (7,) using the formula: Ry Teo The initial resistance of (R,) shall be measured as laid down in Clavase 1804 NOTE, For the temperature correction after shut-down, ste Sub-
You might also like
Is 16227 Part-1 PDF
PDF
100% (4)
Is 16227 Part-1 PDF
62 pages
Is 16227 Part-2 PDF
PDF
100% (5)
Is 16227 Part-2 PDF
66 pages
Indian Standard: Safety of Household and Similar Electrical Appliances
PDF
100% (4)
Indian Standard: Safety of Household and Similar Electrical Appliances
141 pages
SQAP For Pumps 2017
PDF
No ratings yet
SQAP For Pumps 2017
79 pages
JSS 51034-1992
PDF
No ratings yet
JSS 51034-1992
80 pages
DefStd 61-12 (Part18)
PDF
100% (1)
DefStd 61-12 (Part18)
40 pages
Naval Headquarters Directorate of Electrical Engineering
PDF
No ratings yet
Naval Headquarters Directorate of Electrical Engineering
50 pages
Specifications of Motors and Starters For Naval Ships
PDF
No ratings yet
Specifications of Motors and Starters For Naval Ships
71 pages
Development & Significance of JSS & JSG in Global Standardization-Col Shiwesh Kumar
PDF
No ratings yet
Development & Significance of JSS & JSG in Global Standardization-Col Shiwesh Kumar
35 pages
Is 4691
PDF
75% (4)
Is 4691
30 pages
DefStan 02-512 pt2
PDF
No ratings yet
DefStan 02-512 pt2
50 pages
Is 16227 Part-4 PDF
PDF
No ratings yet
Is 16227 Part-4 PDF
18 pages
Def Stan 61-12 Part 18
PDF
No ratings yet
Def Stan 61-12 Part 18
43 pages
Din 40050 9 1993
PDF
No ratings yet
Din 40050 9 1993
28 pages
Is 16227 Part-3 PDF
PDF
100% (4)
Is 16227 Part-3 PDF
26 pages
Nes 511
PDF
100% (1)
Nes 511
20 pages
Is 16227 Part-4 PDF
PDF
No ratings yet
Is 16227 Part-4 PDF
18 pages
DEF STAN 02-526 Issue 2
PDF
No ratings yet
DEF STAN 02-526 Issue 2
44 pages
JSS-55555-2012 - High Temperature Test - Base
PDF
100% (1)
JSS-55555-2012 - High Temperature Test - Base
7 pages
BV Rules - Transformers
PDF
No ratings yet
BV Rules - Transformers
3 pages
Nes 511
PDF
0% (1)
Nes 511
20 pages
Burn in Testing of Naval Electrical Electronic Equipment
PDF
No ratings yet
Burn in Testing of Naval Electrical Electronic Equipment
4 pages
NES 512 Part 11
PDF
100% (1)
NES 512 Part 11
84 pages
SQAP For Starter or Control Panel
PDF
No ratings yet
SQAP For Starter or Control Panel
29 pages
JSS 52300-1992 PDF
PDF
100% (2)
JSS 52300-1992 PDF
68 pages
JSS 5999-10
PDF
100% (1)
JSS 5999-10
28 pages
Compendium Environment Test
PDF
No ratings yet
Compendium Environment Test
221 pages
JSS 50401-1994
PDF
No ratings yet
JSS 50401-1994
343 pages
Nes 535
PDF
100% (1)
Nes 535
32 pages
ASTM E84-2021a
PDF
No ratings yet
ASTM E84-2021a
26 pages
BV Rules - Transformers
PDF
No ratings yet
BV Rules - Transformers
2 pages
JSS 55555 Dust Chamber
PDF
No ratings yet
JSS 55555 Dust Chamber
5 pages
Jss & JSG Guide
PDF
No ratings yet
Jss & JSG Guide
186 pages
JSS 50860
PDF
100% (4)
JSS 50860
118 pages
Section 5 T: Ransformers
PDF
No ratings yet
Section 5 T: Ransformers
2 pages
QM 333
PDF
60% (5)
QM 333
50 pages
JSS-55555-2012 - Low Temperature Test - Base
PDF
No ratings yet
JSS-55555-2012 - Low Temperature Test - Base
6 pages
Code
PDF
No ratings yet
Code
7 pages
Is 6380
PDF
100% (1)
Is 6380
14 pages
Aqa Directive 2 Jan 2015 QTP Atp
PDF
No ratings yet
Aqa Directive 2 Jan 2015 QTP Atp
24 pages
Indigenisation Procedure DDPMAS 2002 PDF
PDF
No ratings yet
Indigenisation Procedure DDPMAS 2002 PDF
149 pages
Jis D 1601-1995
PDF
No ratings yet
Jis D 1601-1995
16 pages
Def Stan 02-514
PDF
No ratings yet
Def Stan 02-514
76 pages
Amphennot Connectors Catalog
PDF
No ratings yet
Amphennot Connectors Catalog
68 pages
Mil STD 461e
PDF
No ratings yet
Mil STD 461e
111 pages
JSS-55555 2012 Nabl PDF
PDF
No ratings yet
JSS-55555 2012 Nabl PDF
18 pages
380V/415V/440V 50HZ/60HZ 3 PH PRIMARY and 230V 50Hz/60Hz 3Ph 4 Wire Secondary Centre Tapped Neutral Earthed Transformer
PDF
No ratings yet
380V/415V/440V 50HZ/60HZ 3 PH PRIMARY and 230V 50Hz/60Hz 3Ph 4 Wire Secondary Centre Tapped Neutral Earthed Transformer
17 pages
Specifications of Ptfe Wires (As Per Jss 51034) : The Company For Sustainable Engineering Solutions
PDF
No ratings yet
Specifications of Ptfe Wires (As Per Jss 51034) : The Company For Sustainable Engineering Solutions
1 page
JSS 4210-16
PDF
No ratings yet
JSS 4210-16
33 pages
Is.1885.11.1966 Electrotechnical Vocabulary, Part 11 Electrical Measurements PDF
PDF
No ratings yet
Is.1885.11.1966 Electrotechnical Vocabulary, Part 11 Electrical Measurements PDF
47 pages
Plugs and Socket-Outlets For Household and Similar Purposes of Rated Voltage Upto and Including 250 V and Rated Current Upto and Including 16 A
PDF
No ratings yet
Plugs and Socket-Outlets For Household and Similar Purposes of Rated Voltage Upto and Including 250 V and Rated Current Upto and Including 16 A
12 pages
23 - 220KV - CT - P - Metering - R - 5 - APR - 10 PDF
PDF
No ratings yet
23 - 220KV - CT - P - Metering - R - 5 - APR - 10 PDF
33 pages
Is.1885.71.1993 Electrotechnical Vocabulary, Part 71 Generation, Transmission and Distribution of Electricity - Substations PDF
PDF
No ratings yet
Is.1885.71.1993 Electrotechnical Vocabulary, Part 71 Generation, Transmission and Distribution of Electricity - Substations PDF
18 pages
50102
PDF
100% (2)
50102
43 pages
Disclosure To Promote The Right To Information
PDF
No ratings yet
Disclosure To Promote The Right To Information
15 pages
Mil STD 2164 - ESS
PDF
No ratings yet
Mil STD 2164 - ESS
49 pages
List of JSS Standards
PDF
0% (1)
List of JSS Standards
5 pages
JSSStandards JSS 5820-19-2006
PDF
No ratings yet
JSSStandards JSS 5820-19-2006
27 pages
Test Facilities at Dqa (N) : 0 o o o o
PDF
No ratings yet
Test Facilities at Dqa (N) : 0 o o o o
5 pages
Etd
PDF
No ratings yet
Etd
116 pages
I S 3024
PDF
100% (1)
I S 3024
9 pages
JSG 0206
PDF
No ratings yet
JSG 0206
14 pages
Is 3347 - 2 - 2
PDF
No ratings yet
Is 3347 - 2 - 2
20 pages
Nes 526 PDF
PDF
100% (1)
Nes 526 PDF
4 pages
NES 362 Type and Production Testing of Mechanical Equipment Category 3
PDF
No ratings yet
NES 362 Type and Production Testing of Mechanical Equipment Category 3
36 pages
Disclosure To Promote The Right To Information
PDF
No ratings yet
Disclosure To Promote The Right To Information
8 pages
World of Steel®
PDF
No ratings yet
World of Steel®
4 pages
IS 13465-1 (2005) - Solventless Polymerisable Resinous Compounds Used For Electrical Insulation, Part 1 - Definitions and General Requirements
PDF
No ratings yet
IS 13465-1 (2005) - Solventless Polymerisable Resinous Compounds Used For Electrical Insulation, Part 1 - Definitions and General Requirements
13 pages
Is.1885.28.1993 Electrotechnical Vocabulary, Part 28 Instrument Transformers
PDF
No ratings yet
Is.1885.28.1993 Electrotechnical Vocabulary, Part 28 Instrument Transformers
15 pages
IS 4257-2 (1986) - Dimensions For Clamping Arrangements For Porcelain Transformer Bushings, Part 2 - For 72
PDF
No ratings yet
IS 4257-2 (1986) - Dimensions For Clamping Arrangements For Porcelain Transformer Bushings, Part 2 - For 72
14 pages
Is.1885.54.1993 Electrotechnical Vocabulary, Part 54 Insulators
PDF
No ratings yet
Is.1885.54.1993 Electrotechnical Vocabulary, Part 54 Insulators
12 pages
Is.5553.4.1989 Reactors, Part 4 Damping Reactors
PDF
No ratings yet
Is.5553.4.1989 Reactors, Part 4 Damping Reactors
8 pages
Unicad Ni-Cd Baterry - Eng
PDF
100% (1)
Unicad Ni-Cd Baterry - Eng
21 pages
As 1359.30-1997 Rotating Electrical Machines - General Requirements Preferred Outputs and Frame Sizes
PDF
No ratings yet
As 1359.30-1997 Rotating Electrical Machines - General Requirements Preferred Outputs and Frame Sizes
7 pages