Polytherm Ac: Highly Efficient, Energy-Saving Flexible Coating

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

polytherm ac

Highly efficient, energy-saving flexible coating


Water-based pure acrylic resin proving efficient thermal protection for the entire structure.

DUBAI GREEN BUILDING REGULATIONS


Certificate No. CL17020460

characteristics
► Durable & provides high degree heat insulation
properties
► Very high emittance & reflectance properties
► Excellent dirt pick-up resistance over longer period of
time
► Reduced thermal conductance and heat gain thereby by
increasing energy efficiency

TDS_Polytherm AC_RTL_1116
► Outstanding adhesion over a variety of substrates
► Waterproofing & resistance to blistering
► Low VOC & non-toxic
► UV protection
► Washable

waterproofing heat resistant 1


DESCRIPTION Surface preparation
Polytherm AC is water-based pure acrylic resin proving All the surfaces must be cleaned and made free of dust,
efficient thermal protection for the entire structure. dirt, moss, oil, grease and other loose particles. This can
Polytherm AC is non-toxic, washable & environment friendly be achieved by grit/sand/shot blasting. As a minimum,
forming a seamless membrane that resist many harsh vigorous wire brushing should be employed. All pot holes
chemicals & bridges hairline cracks. Polytherm AC has high and surface defects shall be repaired with a suitable
emittance & reflectance as well as a very low conductivity concrete repair mortar from the Polycrete* range.
value which reduce thermal shock & heat penetration Priming
thereby keeping roofs much cooler in hot summer weather. Polytherm AC does not require priming and can directly be
They offer UV protection & display excellent dirt pick-up applied onto the surface. In case of highly porous surface,
resistance and retain their flexibility long after aging.­­ a priming coat is recommended to seal the pores and
stabilize the surface. The primer coat can be produced on
FIELDS OF APPLICATION site by diluting Polytherm AC 1 to 1 with water. Apply the
– roofs, terraces, balconies, domes, etc. primer coat @ 5m2/L and allow to dry.
– sandwich panels, corrugated sheets Mixing
– overcoating on minerals surfaced waterproofing Polytherm AC is a single component product but mix
membranes the contents of the pail thoroughly prior to application
– concrete facades to remove any sediment. A slow speed drill and suitable
paddle mixer shall be used to avoid the formation of
APPLICATION INSTRUCTIONS bubbles.
The application temperature should be between 5°C to 45°C.
Application procedures may vary slightly depending upon
Application
Once mixed, Polytherm AC should be immediately
site conditions. The general recommended guidelines for the
applied either by brush, roller or industrial sprayer. It is
application of the coating system is as follows:
recommended that coating be applied in a minimum of
two coats, coating shall be applied 3m2/liter/coat & should TECHNICAL PROPERTIES
not be applied if relative humidity exceeds 95%. Each
subsequent coat shall be applied only after the previous PROPERTIES VALUES TEST
coat dries off completely. After application the coating STANDARDS
must be back rolled to reduce surface irregularities and Drying time
improve bonding. Prior to the application of each coat the (at 25°C & 50% humidity)
surface should be examined for signs of pin-holing, etc. To to set 45 min
overcoat, it is imperative that the second coat be applied to recoat
within the specified overcoating time. Note: Do not dilute Solids content, [%] 63±2 ASTMD1644,
COVERAGE D2396
Polytherm AC: Tensile strength, initial,
RT (22°C) [Mpa] 1.8 ASTMD2370
concrete roof 0.83L/m2 for 500µ DFT
Elongation, initial,
metal roof 0.67L/m2 for 400µ DFT RT (22°C), [%] > 200% ASTMD2370
minimum reommended thickness is 500µ DFT and for Tensile strength,
metal roof reommended thickness is 400µ DFT this can be G156 1000hrs, RT (22°C),
achieved in two coats. [Mpa] 2.7 ASTMD2370
CLEANING & DISPOSAL Elongation, G156 1000hrs,
Clean all equipment & tools using fresh water & flush RT (22°C), [%] > 170% ASTMD2370
mineral spirits through spray equipment to prevent rusting. G156, WOM 1,000 hours Pass ASTMD4798
All disposal practices must be in compliance with all local Water swelling
laws and regulations. resistance, [%] < 8% ASTMD471
TDS_Polytherm AC_RTL_1116

STORAGE & SHELF LIFE Adhesion (Dry) – concrete,


Store in a cool, dry place and keep away from all sources steel & polyurethane
of heat and sunlight. In tropical climates, store in air form, [PLI] > 3 PLI* ASTMC794,
condition rooms. The shelf life is up to 12 months in un- D903
opened condition and if stored as per recommendations. Adhesion (wet)- concrete, ASTMC794,
Excessive exposure to sunlight, humidity and UV will result steel & polyurethane D903
in the deterioration of the quality of the product and reduce form, [PLI] > 2 PLI
its shelf life. Tear resistance, [lbf/in] > 95 ASTMD624
SUPPLY Water vapor transmission,
2 [perms] 11.6 perms
Polytherm AC 20L pail Water vapor transmission
*Refer to website for TDS rate, [g/(h*m2)] 3.51
HEALTH & SAFETY Water vapor transmission
[sd (m) Vapordiff equ air
As with all construction chemical products, caution should
thickness] 0.296
always be exercised. Protective clothing such as gloves
and goggles should be worn. Treat a ny splashes to the Dirt pick up resistance, [%] 97% (with UV)DOW
skin or eyes with fresh water immediately. Should any of 71% (without UV)
the products be accidentally swallowed, do not induce Solar reflectivity, [%] 86% C1549
vomiting, but call for medical assistance immediately. For Emissivity, [%] 90% C1471
safe handling information on this product, please refer to
VOC, [g/L] ≤50 ASTMD 3960/
the Material Safety Data Sheet (MSDS).
D2369
Apart from the information given here it is also important to observe the relevant All values given are subject to 5-10% tolerance
guidelines and regulations of various organisations and trade associations as
well as the respective standards. The aforementioned characteristics are based *Applied on concrete and steel with primer
on practical experience and applied testing. Warranted properties and possible
uses which go beyond those warranted in this information sheet require our
written confirmation. All data given was obtained at an ambient and material
temperature of +23°C and 50 % relative air humidity at laboratory conditions
unless specified otherwise. Please note that under other climatic conditions
hardening can be accelerated or delayed.
The information contained herein, particularly recommendations for the
handling and use of our products, is based on our professional experience.
As materials and conditions may vary with each intended application, and
thus are beyond our sphere of influence, we strongly recommend that in each
case sufficient tests are conducted to check the suitability of our products
for their intended use. Legal liability cannot be accepted on the basis of the
contents of this data sheet or any verbal advice given, unless there is a case
of wilful misconduct or gross negligence on our part. This technical data sheet
supersedes all previous editions relevant to this product.

Henkel Polybit Industries Ltd.


PO Box: 293, Umm Al Quwain, UAE
Phone: +971 (6) 76 70 777; Fax: +971 (6) 76 70 197
[email protected]; www.henkelpolybit.com

You might also like