01 - MGS2500C6CP L51M68 20190307
01 - MGS2500C6CP L51M68 20190307
01 - MGS2500C6CP L51M68 20190307
MGS2500C
POWER RATING (0.8 P.F.) MODEL CODE
PRIME 1720 kW 6CP-L51M68
Conditions:
Engine ratings are based on SAE J1349 standard conditions and also apply at ISO3046/1, DIN6271 & BS5514 standard
conditions.
Fuel rates: based on ASTM D975, BS2869 and on fuel oil of 35° API (16°C or 60° F) gravity having a LHV of 42,780 kJ/kg
(18,390 Btu/lb.) when used at 29°C (85° F) and weighing 838.9 g/liter (7.001lbs./U.S. gal.).
Note: * Please consult with your nearest Mitsubishi MGS dealer for additional rating requirements.
PRIME
1720 kW
Overall dimensions L : Length mm 5775
W : Width mm 2395
H : Height mm 3460
Total Weight (Dry) kg 14400
Total Weight (Wet) kg 15090
Bore mm 170
Stroke mm 180
Displacement L 65.37
Piston speed m/sec. 10.8
Compression ratio 14.0
Lubricating oil capacity L 230
Coolant capacity without/with radiator L 170/399
Coolant pump external resistance m water 3.5
Coolant pump flow rate L/min 1850
Cooling fan airflow rate m3/min 2500
Cooling fan air flow restriction kPa 0.1
Ambient air temperature ℃ 40
Allowable exhaust back pressure kPa 6.0
Exhaust flange size (internal diameter) mm 350
PRIME
1720 kW
Gross Engine Power* kWm 1895
Brake mean effective pressure MPa 2.0
Regenerative absorption kW 192
Noise Level at 1 m dB(A) 114
(excluding: intake, exhaust & fan)
Fuel consumption load 100%* L/hr. 463
Fuel consumption load 75%* L/hr. 355
Combustion air inlet flow rate m3/min 175
Exhaust gas flow rate m3/min 464
Exhaust gas temperature ℃ 530
Heat rejection to coolant kW 716
Heat rejection to exhaust kW 1643
Heat rejection to atmosphere from engine kW 154
Heat rejection to atmosphere from generator kW 91
* WITH FAN basis.
Mounting
Fabricated cubicle mounted on individual bracket with anti-vibration isolator
■ EXHAUST
Exhaust Silencer
Exhaust Flexible Pipe
Mitsubishi Heavy Industries Engine System Asia Pte Ltd, serves for the customers with improved products continually.
Therefore specification and some materials will be changed without notice.
The International System of units (SI) is used in this publication.