Instruction Manual: Standalone Access Control
Instruction Manual: Standalone Access Control
Packing list
INSTRUCTION Name
Digital Keypad K4-2
Quantity
1
Remark
Please ensure that all the above contents are correct. If any are
missing please notify the supplier of the K4-2.
2. Description
The K4-2 is single door multifunction standalone access controller or
a Wiegand output keypad or card reader. The K4-2 supports up to
2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The
inbuilt card reader supports EM, 125KHZ frequency cards. The K4-2
has many extra features including an anti-magnetic MOS output, lock
output current short circuit protection, a Wiegand input and output
interface. These features make the K4-2 an ideal choice for door
access not only for small shops and domestic households but also for
commercial and industrial applications such as factories, warehouses,
laboratories, banks and prisons.
3. Features
• Mini Access Controller
• Full programming from the keypad
• 2000 users, supports Card, PIN, Card + PIN
• Can be used as a stand alone keypad
• Wiegand 26 input for the connection of an external reader
• External readers can be any make of card reader with a 26 bit
output, i.e. HID, Mifare, EM and so on
• Wiegand 26 output for connection to a controller
• Dual K4-2 units can interconnected and interlocked
• One programmable MOS output
• Adjustable Door Output time, Alarm time, Door Open time
• Anti-magnetic MOS output
K4-2 •
•
Lock output current short circuit protection
Easy to install and program
Standalone Access Control • Built in Tamper Switch for anti-demolition
1
• Built in buzzer 6. Wiring
• LED display the working status
• Two year warranty Colour Function Description
• Programmable Fail Safe or Fail Secure Operation Wiegand Output D0 (or input from an
Green D0 external reader)
4. Specifications
Wiegand Output D1 (or input from an
White D1 external reader)
Operating Voltage 12V DC
User Capacity Grey Alarm - Alarm Negative
2000
Yellow OPEN Request to Exit Button
Keypad 12 keys
Brown D-In Door Contact
Card Type EM 125 HZ card
Red 12V + 12V + DC Regulated Power Input
Card Reading Distance 3-6 cm
Black GND 0V DC Regulated Power Input
Active Current <60mA
Common 0V rail for the REX and
Blue VSS
Idle Current 15±5 mA the door contact
Lock Output Load 3A Purple L- Lock Ground/Negative
Alarm Output Load 3A Orange L+/Alarm+ Lock and Alarm Positive
Operating Temperature -40~60℃
Operating Humidity 5%- 95% RH Connection Diagram
Adjustable Door Relay time 0 -99 seconds
Common Power Supply
Adjustable Alarm Time 0- 3 minutes
K4-2
Wiegand Interface Wiegand 26 bit
J1
Electric Lock, Exit Button, DOTL, D0 Green Exit Button
Wiring Connections Alarm
External Alarm DC12V/3A
-
D1 White + -
+
Dimensions 50X120X27mm
ALARM- Grey
N. W / G.W 100g / 250g
OPEN Yellow
D_IN Brown
5. Installation Door Detecting Switch
+12V Red
• Remove the back cover from the
GND Black
keypad using the supplied security J1
screwdriver
Wiring Cable Hamess
VSS Blue
ALARM+
ALARM-
D_IN
OPEN
+12V
L+
GND
VSS
L-
D1
D0
Orange
Purple
Blue
Black
Red
Brown
Yellow
Grey
White
Green
• Fix the back cover firmly on the wall Door power setting: You can choose between
TAMPER SWITCH
2 3
Special Power Supply 9. Anti Tamper Alarm
J1 The K4-2 is built-in tamper switch. If the keypad is removed from the
Exit Button Alarm cover then the tamper alarm will operate.
D0 Green
DC12V/3A
D1 White + - PUSH NC COM NO
10. Sound and Light indication
ALARM- Grey
OPEN Yellow Operation Status Red Light Green Light Buzzer
Door Detecting Switch
Fail-securelock Power on - Bright Short Ring
D_IN Brown
Stand by Slow Flash - -
+12V Red
- -
Fail-safe lock
The above diagrams show the output interface circuits. Unlike most Note that to undertake the following programming the master user
lock and alarm outputs which use a relay that can be shocked or must be logged in
magnetized, the K4-2 uses MOS outputs for both the Lock Output To change the master code 0 New code # New code #
on the left and the Alarm Output on the right. The master code can be 6 to 8 digits
long
8. To Reset to Factory Default Setting the working mode: 3 0 # Entry is by card only
Set valid card only users 3 1 # Entry is by card and PIN
To reset to factory default, power off, press the RESET key(K2 ) on Set valid card and PIN users together
Set valid card or PIN users 3 2 # Entry is by either card or
the PCB, hold it and power on, release it until hear three beeps
PIN (default)
means reset to factory default successfully.
Remarks: Reset to factory default, the user’s information is still To set a user in either card or PIN mode. (Default setting 3 2 # ).
retained.
4 5
1 User ID number # PIN # To Add a Card and Pin user Add the card as for a card user
The ID number is any number (The PIN is any four digits Press * to exit from the
between 1 & 2000. The PIN is any between 0000 & 9999 with programming mode
four digits between 0000 & 9999 with the exception of 1234 which Then allocate the card a PIN as
the exception of 1234 which is is reserved.) follows: * Read card 1234 #
To add a Pin user
reserved. Users can be added PIN # PIN #
continuously without exiting
To change a PIN in card
programming mode as follows:
and PIN mode (Method 1)
1 User ID no 1 # PIN #
Note that this is done * Read Card Old PIN # New PIN #
User ID no 2 # PIN #
outside programming mode New PIN #
2 User ID number # so the user can undertake
To Delete a Pin user Users can be deleted continuously this themselves
without exiting programming mode
To change a PIN in card
To change the PIN of a PIN and PIN mode (Method 2)
user (This step must be done * ID number # Old PIN # Note that this is done * ID number # Old PIN #
New PIN # New PIN #
out of programming mode) outside programming New PIN # New PIN #
To add a Card user (Method mode so the user can
1) This is the fastest way to undertake this themselves
1 Read Card #
enter cards using ID number To delete a Card and PIN
Cards can be added continuously 2 Read Card # or 2 User ID #
auto generation. The ID user just delete the card
without exiting programming mode
number will start from1, if no
To set a Card user in card mode ( 3 0 # )
user has been programmed.
The operating is the same as
To add a Card user (Method To Add and Delete a Card
adding and deleting a card user in
2) This is the alternative way user
3 2 #
to enter cards using User ID
To delete ALL users.
Allocation. In this method a 1 ID number # Card #
User ID is allocated to a The ID number is any digit between To delete ALL users. Note
card number. Only one user 1-2000. that this is a dangerous 2 0000 #
ID can be allocated to a option so use with care
single card.
To unlock the door
To delete a Card user by For a PIN user Enter the PIN then press #
card number. Note users
can be deleted continuously 2 Read Card # For a Card User Read card
without exiting programming For a Card and PIN user Read card then enter PIN #
mode
To delete a Card user by 11.2 Door Settings
user ID. This option can be Lock Power Setting & Door relay time setting
2 User ID #
used when a user has lost
their card Fail Secure (unlocked * Master code # 4 0~99 # *
when power is on) 0-99 is to set the door relay time
To set a Card and PIN user in card and PIN mode ( 3 1 # )
0-99 seconds. 0 for 50mS
6 7
Fail safe (unlocked when * Master code # 5 1~99 # * Door Interlock.
power is off) This is the 1-99 is to set the door relay time
factory default, 5 seconds: 1-99 seconds Door interlock disabled 8 0 # (Factory default setting)
Door interlock enabled 8 1 #
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an
optional magnetic contact or built-in magnetic contact of the lock,
if the door is opened normally, but not closed after 1 minute, the 12. Advanced Applications
inside buzzer will beep automatically to remind people to close the
12.1 Operating as a Wiegand Output Reader
door and continue for 1 minute before switching off automatically.
In this mode the K4-2 supports a Wiegand 26 bit output so the
Door Forced Open warning. When used with an optional magnetic Wiegand data lines can be connected to any controller which
contact or built-in magnetic contact of the lock, if the door is forced supports a Wiegand 26 bit input. See figure 1.
open, or if the door is opened after 20 seconds of the
electro-mechanical lock not closed properly, the inside buzzer and
alarm output will both operate. The Alarm Output time is adjustable J1
between 0-3 minutes with the default being 1 minute. D0 Green D0
D1 White D1
To disable door open
6 0 # Grey ALARM-
detection. (Factory default)
+12V
Yellow OPEN
To enable door open GND
6 1 # Brown D_IN
detection
Red +12V
Alarm output time Controller
Black GND
To set the alarm output time Powerful
supply Blue VSS
(0-3 minutes) Factory default is 9 0~3 #
+ Purple L-
1 minute
Orange L+
- ALARM+
Keypad Lockout & Alarm Output options. If there are 10 invalid
cards or 10 incorrect PIN numbers in a 10 minute period either the
Controller with wiegand 26 input K4-2
keypad will lockout for 10 minutes or the alarm will operate for 10
minutes, depending on the option selected below.
Figure 1
Normal status: No keypad
lockout or alarm (factory 7 0 # (Factory default setting)
default) 12.2 Operating as a Controller
Keypad Lockout 7 1 # In this mode the K4-2 supports a Wiegand 26 bit input so an external
Wiegand device with a 26 bit output can be connected to the Wiegand
Alarm Output 7 2 # input terminals on the K4-2. Either an ID card reader (125 KHZ) or an
To remove the alarm IC card reader (13.56MHZ) can be connected to the K4-2. Cards are
To remove the Door Forced required to be added at the external reader, except where an external
Open warning Read valid card or Master Code # EM reader is used, in this case cards can be added at either reader.
See figure 2.
To remove the Door Open Close the door or Read valid card or
Too Long warning Master Code #
8 9
12.3 Two K4-2 units interconnected for a single door 12.4 Two K4-2 units interconnected & interlocked for 2 doors
In this mode two K4-2 units are used for a single door, one for entry In this mode two K4-2 units are used for a two doors which are then
and the other for exit. Either device acts as the controller and reader interconnected and interlocked. In this mode the doors can be
at the same time. Users can be enrolled on either of the devices. In interlocked so that when door 1 is open, door 2 cannot be opened,
this mode the user capacity for one door can be up to 4000. The and vise versa. The interlocked function is mainly used in banks,
setting of the two K4-2 units must be the same including the master prisons, and other places where a higher level of security is required.
code. See figure 3. See figure 4
Power
ALARM-
OPEN
wiegand reader
ALARM+
DC12V/3A
+12V
D_IN
GND
K4-2 controller
VSS
K4-2 Controller 2
L+
Type of lock setting: do door relay setting according to the type of lock connected (fail safe or fail secure lock).
+ -
D0
D1
Em card
GND
L-
IC card
J1 +12V HID card
D0
D0 Green D1
White Reader Plug
Red
Green
Brown
White
Blue
Purple
Orange
D1
Grey
Yellow
Black
J1
Grey -
ALARM-
+
OPEN Yellow
Alarm
Door 2
Brown
Exit Button 2
L- Purple -
Lock
+
L+ Orange
ALARM+ +
Lock 2
Type of lock setting: do door relay setting according to the type of
Alarm 2
+
-
Lock 1
+
Power outdoor
indoor
DC12V/3A
Alarm 1
J1
+
+ -
-
J1
Green D0
D0 Green
+
-
White D1
D1 White
Exit Button 1
- Grey ALARM-
ALARM- Grey
+
OPEN Yellow Yellow OPEN
Door Detecting Switch 1
Alarm
Door 1
Purple
White
Yellow
Black
Reference 11.2
Grey
Blue
Purple Purple
J1
L- L-
Red
-
L+ Orange Lock Orange L+
ALARM+ +
ALARM+
D_IN
OPEN
GND
VSS
D0
L-
ALARM-
+12V
ALARM+
L+
Type of lock setting: do door relay setting according to the type of lock
connected (fail safe or fail secure lock). Reference 11.2
Figure 3 Figure 4
10 11