INSTALLATION

Examples of input circuits

Note: The external relay's life may be improved by adding a


metallized-polyester capacitor (0.022µF 100V or higher)
in parallel with the relay contacts.
1. Relay interface

+24 VDC

Output from
HPR
CNC/PLC

External relay
(AC or DC)

Power
ground

2. Optocoupler interface
+24 VDC

CNC/PLC
HPR

Transistor-output
optocoupler
Power
ground

3. Amplified-output interface

CNC/PLC +24 VDC


12V-24VDC

HPR

Power
Active-high drive ground Power
ground