0% found this document useful (0 votes)
177 views2 pages

Adc Solo en

The ADC Solo is a small-footprint digital X-ray cassette digitizer that provides high image quality in a compact and affordable package. It features a unique direct identification function that receives patient data simultaneously as it scans imaging plates, eliminating separate patient identification steps. The ADC Solo digitizes plates with 12-bit grayscale resolution, transferring full data sets for top imaging quality on a variety of cassette sizes. Its small size allows use in confined spaces, and its automated functions simplify the digitization process.

Uploaded by

Nikolay Penev
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
177 views2 pages

Adc Solo en

The ADC Solo is a small-footprint digital X-ray cassette digitizer that provides high image quality in a compact and affordable package. It features a unique direct identification function that receives patient data simultaneously as it scans imaging plates, eliminating separate patient identification steps. The ADC Solo digitizes plates with 12-bit grayscale resolution, transferring full data sets for top imaging quality on a variety of cassette sizes. Its small size allows use in confined spaces, and its automated functions simplify the digitization process.

Uploaded by

Nikolay Penev
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ADC SOLO

DIGITIZER

Smallest-footprint digitizer for


personal computed radiology

The ADC Solo is the smallest-footprint, fully identification and subsequently be placed into Full data for top imaging quality
functional digitizer on the market today. It the ADC Solo for digitization. Additional The ADC Solo reads the imaging plates with
features a unique direct identification function, strengths are manifested when the ID software 12 bits/pixel greyscale resolution.
which receives patient data while the imaging is linked with the HIS/RIS system by means of The complete raw data set is transmitted to
plate is being scanned, avoiding the need for a ADC Rislink Toolkit software. the image processing computer. Spatial
separate ID Tablet and additional cassette resolution can range from 6 to 9 pixels/mm.
handling. Instant image preview
ADC Solo’s versatile Preview software allows An economic way to go digital
Digital imaging in any location for checking patient positioning, collimation ADC Solo cassettes are compatible with
The economical ADC Solo has a footprint so border detection and processing quality even conventional X-ray tables. This allows
small that it can easily be placed in the most before the hardcopy is printed or the softcopy conventional X-ray departments to go digital
confined location or practice. Designed with is sent to its destination. When digitized with without extra investments in digital X-ray
ease-of-use in mind, it requires only a the ADC Solo, the images can be immediately units. The flexibility of the ADC Solo makes it a
standard wall-outlet. After a quick and simple evaluated. cost-effective building block on the way to a
installation by a service technician, you are fully digital X-ray department, right from day
immediately ready to enjoy the many Automated processing lets you get on one.
advantages of digital imaging. with your work
The ADC Solo Digitizer scans the exposed ADC
Time saving direct identification imaging plate, converts the information into
A unique function, which places the ADC Solo digital data and automatically transfers the
ahead of its competitors, is its capacity to image to the image processing computer for
receive ID data and scan the imaging plate further processing and visualization as well as
simultaneously. The cassette is inserted into to a predefined preview station. It requires no
the ADC Solo for image scan whilst patient manual interaction. Once the cassette is
data is entered on the ID station. Once the inserted, the ADC Solo automatically takes it
image scan is complete, both the scanned from the input, reads the demographic data
image and ID data are merged and sent to the from the cassette memory chip, scans the
processing station. Alternatively, the cassette imaging plate, digitizes the image and returns
can also be inserted in the ADC ID Tablet for the cassette to the output for new exposures.
ADC Solo Digitizer
Technical data

General Environmental conditions Performance


Temperature: 15 - 30 °C
Temperature change: 0.5 °C/min
Digitizer type Humidity: 15 - 75% RH Throughput
Single cassette feed Magnetic fields: max. 12.60 µT 60 plates/h (18 x 24 cm)
(in conformance with EN 61000-4-8: 50 plates/h (35 x 43 cm)
level 3), 10 A/m 35 plates/h (35 x 43 cm HR)
Dimensions
45 x 75 x 141 cm (W x D x H)
(Depth 73 cm at cassette-slot) Environmental effects Spatial resolution
Noise level: max. 65 dB (A) Reading sampling frequency:
Heat dissipation: standby 230 W 35 x 43 cm: 6 pixels/mm
Weight maximum 1610 W 35 x 35 cm: 6 pixels/mm
approx. 210 kg 35 x 43 cm HR: 9 pixels/mm (option)
35 x 35 cm HR: 9 pixels/mm (option)
Power Display 24 x 30 cm: 9 pixels/mm
Machine status and error conditions,
230 - 240 V/ 50 - 60 Hz standby 230 W, 18 x 24 cm: 9 pixels/mm
emergency keys
max. 1610 W, 16 A fuse (USA) 8 x 10”: 9 pixels/mm
120 V/ 60 Hz (USA) standby 216 W, 10 x 12”: 9 pixels/mm
max. 1440 W, 15 A fuse Safety standards
100 V/ 60 Hz (Japan) standby 220 W, EN 60950, 60825-1: 1994, 60601-1-2,
max. 1500 W, 15 A fuse UL 1950 Greyscale resolution
Data acquisition: 12 bits/pixel
CSA C22.2 No 950 Output to processor: 12 bits/pixel
DHHS/FDA 21 CFR parts 1040.10 and 1040.11
Accepted cassette sizes CFR title 21, part 820
35 x 43 cm (14 x 17”) EEC 89/336, 93/42, 73/23, 89/392
35 x 35 cm (14 x 14”)
24 x 30 cm
18 x 24 cm Approvals
15 x 30 cm TüV, GS, CE, UL, CUL
8 x 10”
10 x 12”

Pixel matrix size


35 x 43 cm: 2048 x 2494
35 x 43 cm HR: 3062 x 3730
35 x 35 cm: 2048 x 2048
35 x 35 cm HR: 3062 x 3062
21 x 43 cm (partial scan of 35 x 43 cm
cassette): 1778 x 3732
24 x 30 cm: 2040 x 2570
18 x 24 cm: 1514 x 2044
15 x 30 cm: 1248 x 2570
8 x 10”: 1714 x 2164
10 x 12”: 2164 x 2614

The data in this publication are for Agfa-Gevaert has been awarded the ISO 9001 Agfa-Gevaert has been awarded the Approval
illustration purposes only and do not Certificate by Lloyd’s Register Quality of Conformity Certificate by Lloyd’s Register
necessarily represent standards or Assurance for the design, development, Quality Assurance. It certifies that the Quality
specifications which must be met by Agfa. procurement and/or production, marketing Management System meets the requirements
Characteristics of the products described in and servicing of imaging and communication of the Medical Devices Directive 93/42/EEC.
this publication can be changed at any time systems for medical applications.
without notice. A high consistency of products is thereby
provided.
Agfa and the Agfa-Rhombus are trademarks
of Agfa-Gevaert AG, Germany.

Printed in Belgium
Published by Agfa-Gevaert N.V.,
B-2640 Mortsel-Belgium