Penetron PDS H06

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

®

T O T A L C O N C R E T E P R O T E C T I O N

PENETRON®
CRYSTALLINE WATERPROOFING COATING

DESCRIPTION DIRECTIONS FOR USE


PENETRON® is a surface-applied, integral crys- Surface preparation:
talline waterproofing material, which waterproofs
All concrete to be treated with PENETRON® must be clean and have an
and protects concrete in-depth. It consists of
“open” capillary surface. Remove laitance, dirt, grease, etc. by means of high
Portland cement, specially treated quartz sand
pressure water jetting, wet sandblasting or wire brushing. Faulty concrete in
and a compound of active chemicals.
the form of cracks, honeycombing, etc. must be chased out, treated with
PENETRON® needs only to be mixed with water
prior to application. PENETRON® and filled flush with PENECRETE MORTAR™. Surfaces must
be carefully pre-watered prior to the PENETRON® application. The concrete
When PENETRON® is applied to a concrete surface must be damp but with no wet sheen on the surface.
surface, the active chemicals react with moisture
and the by-products of cement hydration to cause Mixing:
a catalytic reaction that generates an insoluble, PENETRON® is mechanically mixed with clean water to a creamy consisten-
crystalline structure. These crystals fill the pores cy or resembling thick oil. Mix only as much material as can be used within
and minor shrinkage cracks in the concrete to 20 minutes and stir mixture frequently. If the mixture starts to set, do not add
prevent any further water ingress (even under more water; simply re-stir to restore workability.
pressure). However, PENETRON® will still allow
the passage of vapor through the structure (i.e. the Mixing ratios:
concrete will be able to “breathe”). Even after the Application method Vertical surfaces Horizontal surfaces
concrete has cured, PENETRON® remains Brush 5 parts PENETRON® 3 parts PENETRON®
dormant in the concrete and will reactivate in the to 2 parts water to 1 part water
presence of moisture to seal capillary tracts and
hairline cracks. Spray 5 parts PENETRON®
to 2.75-3.25 parts water
In addition to waterproofing the structure,
PENETRON® protects concrete against sea- Application:
water, wastewater, aggressive groundwater and Slurry consistency: Apply PENETRON® in one or two coats according to
many other aggressive chemical solutions. specification by masonry brush or appropriate power spray equipment. When
PENETRON® is approved for use in contact with two coats are specified, apply the second coat while the first coat is still
potable water and is therefore suitable for use in “green.”
water storage tanks, reservoirs, water treatment
plants, etc. Dry powder consistency (for horizontal surface only): The specified amount
of PENETRON® is distributed in powder form through a sieve or a semi-me-
APPLICATIONS chanical barrow spreader and troweled into the freshly placed concrete once
this has reached initial set.
Basement retaining walls
Parking structures Application rates:
Concrete slabs (floor/roof/balcony, etc.) Vertical surfaces: Two coats of PENETRON® at 1.25-1.5 lb/yd² (0.7-0.8
kg/m²) applied by brush or spray. Please contact your Penetron Representa-
Tunnels and subway systems
tive for alternative application methods that may be applicable to your project
Construction joints and help to increase production.
Foundations
Horizontal flatwork: PENETRON® at 2 lb/yd² (1.1 kg/m²) applied in one
Water retaining structures slurry coat to hardened concrete. Alternatively, PENETRON® can be dry
Underground vaults sprinkled at 1.8 lb/yd² (1 kg/m²) and trowel-applied to fresh concrete when it
Swimming pools has reached initial set.
Sewage and water treatment plants Construction joints: PENETRON® at 3 lb/yd² (1.6 kg/m²) applied in slurry or
Channels dry powder consistency immediately prior to placing the next lift/bay of
concrete.
Reservoirs
Blinding concrete: PENETRON® at 2.5 lb/yd² (1.4 kg/m²) applied in slurry or
Bridges, dams and roads
dry powder consistency immediately prior to placing the overlying concrete
slab.
TOTA L CO N C R E T E P R OT E CT I O N ® Page 1
PENETRON®

Post-treatment: ADVANTAGES
The treated areas should be kept damp for a period of five days and must be Becomes an integral part of the concrete.
protected against direct sun, wind and frost, by covering with polyethylene Can be applied to all structurally sound
sheeting, damp burlap or similar. concrete – new or old.
CLEAN UP Penetrates deeply and seals concrete’s capillary
tracts and shrinkage cracks.
Use water to clean all tools immediately after use. Can be applied from either the positive or negative
side.
SPECIAL CONSIDERATIONS
Waterproofing and chemical-resistance properties
w Do not apply PENETRON® at temperatures at or below freezing or to remain intact even if the surface is damaged.
frozen or freezing surfaces. Completely effective against high hydrostatic
w PENETRON® cannot be used as an additive to concrete or plasters. pressure.
PENETRON ADMIX® should be considered for these applications. More effective overall and less costly than hydrolytic
w PENETRON® should not be confused with a coating or membrane. membrane or clay panel systems.
Easy to apply, labor-cost effective.
w PENETRON® is not a decorative material.
Increases concrete’s compressive strength.
PACKAGING Will not come apart at the seams, tear or be punc-
tured.
PENETRON® is available in 50-lb (22.7-kg) bags or 55-lb (25-kg) pails.
Does not require protection during backfilling,
STORAGE / SHELF LIFE placement of steel or wire mesh, and other common
procedures.
PENETRON products must be stored dry at a minimum temperature of 45ºF
Seals hairline and shrinkage cracks up to 1/64” (0.4
(7ºC). Shelf life is one year when stored under proper conditions.
mm).
TECHNICAL SERVICES Resists chemical attack (pH 3-11 constant contact,
pH 2-12 intermittent contact) and provides a range
For more detailed instructions, alternative application methods, or information of protection from freeze/thaw cycles, aggressive
concerning the compatibility of the PENETRON treatment with other products subsoil waters, seawater, carbonates, chlorides,
or technologies, contact the Penetron Technical Department or your local sulfates and nitrates.
Penetron representative.
Can be applied to moist or “green” concrete.
SAFE HANDLING INFORMATION Protects embedded steel (reinforcing steel and wire
mesh).
PENETRON® contains cement, which is alkaline. Will irritate eyes and skin
Non-toxic (NSF 61 certified for potable water appli-
and may cause skin sensitization. Wear appropriate eye, skin and breathing
cations).
protection when using this product. Avoid contact with skin and eyes. In case of
contact with eyes, rinse immediately with plenty of water and seek medical Zero VOC - PENETRON powdered products contain
advice. For further information please refer to Safety Data Sheet. KEEP OUT zero volatile organic compounds and are safe for
use both outdoors and in confined indoor spaces.
OF REACH OF CHILDREN.

001aCPR2013-07-10
EN 1504-3
Penetron International, Ltd.
601 South Tenth Street, Unit 300
Allentown, PA 18103
08
PENETRON WARRANTY: PENETRON INTERNATIONAL, LTD. warrants that the products manufac-
tured by it shall be free from material defects and will conform to formulation standards
for structural and non-structural repair CC mortar and contain all components in their proper proportion. Should any of the products be
proven defective, the liability to PENETRON INTERNATIONAL, LTD. shall be limited to
Compressive strength: Class R3 (≥ 25 MPa) replacement of the material proven to be defective and shall in no case be liable
Chloride content: < 0,05 % by mass otherwise or for incidental or consequential damages. PENETRON INTERNATIONAL, LTD.
Adhesive bond: NPD MAKES NO WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND THIS
WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. User shall determine
Restrained shrinkage, expanding: NPD the suitability of the product for its intended use and assume all risks and liability in
Elastic modulus: NPD connection therewith.
Thermal compatibility (Part 1): NPD
Corrosion behaviour: deemed to have no corrosive effect PENETRON INTERNATIONAL, LTD.
Reaction to fire: NPD
45 Research Way, Suite 203, East Setauket, NY 11733
Dangerous substances: NPD
(631) 941-9700 • [email protected] • penetron.com

TOTA L CO N C R E T E P R OT E CT I O N ® v. H06 Page 2