General Notes: Fourth Floor Plan

This document provides measurements and specifications for classroom construction. It includes dimensions for windows, shutters, louvers and ventilation caps. It lists measurements for 5 classrooms, including the length and width. Blackboard bases are also noted. The overall design and measurements allow for construction of 5 standard classrooms.

Uploaded by

Juan Istil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
208 views1 page

General Notes: Fourth Floor Plan

This document provides measurements and specifications for classroom construction. It includes dimensions for windows, shutters, louvers and ventilation caps. It lists measurements for 5 classrooms, including the length and width. Blackboard bases are also noted. The overall design and measurements allow for construction of 5 standard classrooms.

Uploaded by

Juan Istil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8 9 10 11 12 13

55000
300 X 300mm
300 X 300mm
AUTOMATIC SHUTTER
AUTOMATIC SHUTTER 3800 1200 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 1825 3425 LOUVERS / VENT CAP
LOUVERS / VENT CAP
1575 3175
1550

C
STO. EF1
EF1 EF1 EF1
HE

3150

3150
CF CF CF CF CF CF CF CF CF CF

SHE
CLASS ROOM CLASS ROOM CLASS ROOM CLASS ROOM CLASS ROOM
7000

1000
1 2 3 4 5
9500

9500
BLACKBOARD BASE

BLACKBOARD BASE

BLACKBOARD BASE

BLACKBOARD BASE

BLACKBOARD BASE
3850

3850
CF CF CF CF CF CF CF CF CF CF

DN UP
B
DN DN
2500

2500
C O R R I D O R C O R R I D O R C O R R I D O R

VENTILATION & CEILING FAN LAYOUT

GENERAL NOTES 1 FOURTH FLOOR PLAN


SCALE 1:100M
M-6
INTERIOR SIDE
OF BUILDING WALL
ORIFICE
1. CONTRACTOR IS ADVISED TO VISIT AND SURVEY THE PLACE OF WIRE
GUARD
INSTALLATION. FAN
MOTOR
FRAME
2. ALL AIR CONDITIONING UNITS AND VENTILATING UNITS TO BE SUPPLIED
SHALL BE NEW AND APPROVED PRODUCTS OF REPUTABLE
AIR FLOW
MANUFACTURERS.
DESIGNATION A B C D E F G H I J K L M

D
FAN
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BLADE

E
COORDINATE CLOSELY HIS WORK WITH THE OTHER TRADES EF1 354 126 140 200 135 230 268 13 300 108 13 108 13
CONCERNED.

H
POWER
CORD
4. REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH 25 mm THICK
PREMOULDED ELASTOMERIC RUBBER INSULATION AS MANUFACTURED FRONT VIEW CORD OUTLET INSTALLATION
EXHAUST K HOLE
BY "ARMAFLEX",AEROFLEX OR APPROVED EQUAL.
F sq. J GRILL CONNECTION TO
3 EXHAUST FAN (WALL MOUNTED) DETAIL
5. INDIVIDUAL WEATHER PROOF TYPE CIRCUIT BREAKER SHALL BE EXHAUST PIPE SCALE NTS
PROVIDED PROVIDED FOR ALL CONDENSING UNITS. M-6

M
G sq.
6. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH EXHAUST

L
D

INSULATION TYPICAL TO REFRIGERANT PIPING. (REFER TO PIPE EF-1


FAN CASING
E

INSULATION DETAIL.) ENCLOSED CIRCUIT BREAKER


IN NEMA 3R ENCLOSURE
H

7. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH (SIZE AS REQUIRED)
INSULATION TYPICAL TO REFRIGERANT PIPING.(REFER TO PIPE I sq. B
INSULATION DETAIL.) EXHAUST
SIDE VIEW FAN BLADE BOTTOM VIEW CONCRETE SLAB VERIFY MINIMUM SPACE
8. ALL NECESSARY GOVERNMENT PERMITS SHALL BE SECURED AND FOR WITH EQUIPMENT SUPPLIER ITEM A B C D E
ACCOUNT OF THE CONTRACTOR. CEILING MOUNTED (CASSETTE TYPE)
VENT CAP 190 106 23 147 53
9. AS-BUILT PLANS SHALL BE PROVIDED BY THIS CONTRACTOR AFTER
COMPLETION OF WORKS.
2 EXHAUST FAN DETAIL 4PCS-12mm Ø
NOT TO SCALE ACCU STORMPROOF
M-6 DYNA BOLT EQUIPMENT BASE STAINLESS STEEL
10. ALL INSTALLATION WORKS SHALL BE DONE IN A NEAT AND WORK- NUT
VENTILATION CAP
MANLIKE MANNER. 12mmØ ROUND NEOPRENE VIB.
BAR HANGER ISOLATOR
11. ALL REFRIGERANT SUCTION LINES EXPOSED INDOORS AND/OR
EXPOSED TO WEATHER SHOULD BE PROVIDED WITH GAUGE #24
ALUMINUM CLADDING. (SUBMIT SHOP DRAWING PRIOR TO 50 x 50 x 6mm
INSTALLATION) CONDUIT
VIBRATION ISOLATOR ANGLE BAR PIPE
A
12. ALL ACCU's AND FCU's SHALL BE PROVIDED WITH ANGULAR BAR LINE OF CEILING
FLR. SLAB WALL
SUPPORTS. (SUBMIT SHOP DRAWING PRIOR TO INSTALLATION) MAX. LOAD DIMENSIONS IN MM. EXHAUST
FCU 1400 X 195 mm

300
H

(LBS) L W H A B C D E AIR DUCT


SUPPLY AIR
E

SECTION - A 35 TO 120 WEATHER TIGHT


LEGENDS: 1400 X 195 mm
REMOVABLE SERVICE PANEL METAL FLEXIBLE Ø4.5 FIXING
"B" NC TAP DIMENSION SAME SIZE OF FCU HOLES SPRING
RETURN AIR CONDUIT
PLATE
ANGLE CONNECTOR
FAN COIL UNITS 135 TO 380 TOP
680

ØD
2400

ØA
W

EXHAUST FANS A
250 TO 1100 800
PROVIDE VIBRATOR ISOLATOR
CONDUIT PIPE TO

0.30 M
AIR COOLED CONDENSING UNITS C ACCU PEDESTAL WITH CIRCUIT HOMERUN C
1500 TO 4000 50 x 50 x6mm ANGLE BAR (SIZE AS REQUIRED) DRAIN B E
L
HOLE
16mm Ø
CEILING FANS PLAN FINISHED FLOOR LINE
FLR. SLAB
EXPANSION BOLT

AUTOMATIC SHUTTER LOUVERS


4 VIBRATION ISOLATOR DETAIL (CONE-TYPE) 5 DET. OF CEILING SUSPENDED FCU 6 ACCU MOUNTING DETAIL 7 VENT CAP DETAIL
M-6 NOT TO SCALE M-6 NOT TO SCALE M-6 NOT TO SCALE M-6 NOT TO SCALE

DESIGNED: SIGNED
REPUBLIC OF THE PHILIPPINES PROJECT AND LOCATION: SHEET CONTENTS: SUBMITTED: RECOMMENDING APPROVAL: APPROVED: CONCURRED: SET NO. SHEET NO.
BENJAMIN R. GALMAK
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GENERAL NOTES
ENGINEER II
SEE COVER SHEET FOR SIGNATURE SEE COVER SHEET FOR SIGNATURE SEE COVER SHEET FOR SIGNATURE
MODIFIED STANDARD DPWH - DEPED LEGENDS
CADD: SIGNED SIGNED
BUREAU OF DESIGN FOURTH FLOOR VENTILATION AND CEILING FAN
EB FUMAR
ENGINEERING ASSISTANT
BR GALMAK
ENGINEER II
APPROVED WITH SIGNATURE BOD
M-6
BUILDINGS DIVISION FOUR (4) STOREY, TWENTY (20) LAYOUT JOSEPHINE P. ISTURIS LEA N. DELFINADO GILBERTO S. REYES LEONOR M. BRIONES
CLASSROOM SCHOOL BUILDING MISCELLANEOUS DETAILS
CHECKED: SIGNED B 8 90
CORNELIO T. EVANGELISTA JR.4 OIC, UNDERSECRETARY FOR
BONIFACIO DRIVE PORT AREA, MANILA CHIEF, BUILDINGS DIVISION OFFICER-IN-CHARGE SECRETARY, DEP ED
ENGINEER III TECHNICAL SERVICES, DPWH