The FRM220-Serial provides a fiber converter solution to extend asynchronous RS-485 or RS-232 transmission distances up to 2km over multimode fiber or 120km over single mode fiber. It has multiple interface circuits to connect to RS-232 or RS-485 in full or half duplex. In-band management allows viewing status when the card is placed in an FRM220 chassis. The converter secures data transmission at speeds up to 460kbps for RS-232 or 1024kbps for RS-485 over EMI resistant fiber.

Uploaded by

Riky Fitriadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views2 pages

FRM220 Serial

The FRM220-Serial provides a fiber converter solution to extend asynchronous RS-485 or RS-232 transmission distances up to 2km over multimode fiber or 120km over single mode fiber. It has multiple interface circuits to connect to RS-232 or RS-485 in full or half duplex. In-band management allows viewing status when the card is placed in an FRM220 chassis. The converter secures data transmission at speeds up to 460kbps for RS-232 or 1024kbps for RS-485 over EMI resistant fiber.

Uploaded by

Riky Fitriadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Multi-Service Platform - Fiber Modem / Converter

RS-485 / 232 over Fiber 1

Fiber Modem
FRM220-Serial
The FRM220-Serial provides a fiber converter solution to Specifications
extend asynchronous RS-485 or RS-232 transmission distance
Optical Interface Connector 1x9 (SC, ST, FC)
up to 2km over multimode fiber or up to 120km over single
Data rate 36.864Mbps
mode fiber. The converter is equipped with multiple interface
Line coding Scrambled NRZ
circuits for connection to RS-232 or RS485 (2 or 4 wire, full or
half duplex). The FRM220-Serial secures data transmission over Bit Error Rate Less than 10-10
EMI resistant fiber at speeds up to 460kbps for RS-232 or up to Fiber MM 62.2/125μm, 50/125μm. SM 9/125μm
1024kbps for RS485. When the FRM220-Serial/485 card is Distance MM 2km, SM 15/30/50/80/120km,
placed in the FRM220 rack with SNMP management, in-band WDM 20/40/60/80km
management allows viewing the card and remote converter's Wavelength MM 1310nm, SM 1310, 1550nm,
status, type, version, fiber link status, data link status and WDM 1310Tx/1550Rx(type A)
alarms. Both card and remote can be configured to enable 1550Tx/1310Rx(type B)
or disable the port, reset the port and set the interface type.
Electrical Interface Connector 6 pins Terminal block
Data Signal Formats
RS-485 2-wire
RS-232 RTS/CTS 5-wire
RS-232 3-wire
Baud Rate RS-422, RS-485 up to 1024kbps
RS-232 up to 256kbps
Bit Error Rate Less than 10-10
Features Standard EIA/TIA RS-485, RS-232
● Extend asynchronous serial transmission from 2km to 120km over fiber LEDs Power, FX Link, DI, DO, Test
● In-band network management via terminal, web or SNMP in Power Input Card : 12VDC
FRM220-CH20 chassis Standalone : AC, DC options
● Software selectable data interface for RS-232/ 485 Power Consumption < 5W
● Software selectable two wires (half duplex) or Dimensions 155 x 88 x 23mm (D x W x H)
four wires (full duplex) RS-485 Weight 0.12kg
● Software selectable three or five wires RS-232 Temperature 0 ~ 60°C (Operating), -10 ~ 70°C (Storage)
● Speeds up to 256kbps for RS-232 (Async. mode) Humidity 10 ~ 90% non-condensing
● Speeds up to 1Mbps for RS-485 Certification CE, FCC, LVD, RoHS
● Standalone RS232 console management via CH01M MTBF 65,000 hrs

RS-485/232 RS-485/232

EMS FRM220-Serial
HOST
FRM220-Serial inserted SCADA
In FRM220 Chassis

RS-485 network on one twisted pair /


RS-485 2-wire half duplex
Twisted pair

FRM220-Serial FRM220-Serial
HOST

Slot machine 1………………….32

Ordering Info rmation


Orde Connector Connectivity
Type Distance

Model Name Description FRM220 – Serial –


FRM220-Serial RS-485/ 232 fiber converter Example: FRM220 – Serial – SC002
Note: The card is suitable for using in CH01M standalone chassis.

Connector Type Connectivity Distance


SC, S T , FC 002: 2km 015: 15km 030: 30km 050: 50km 080: 80km 120:120km
20A: WDM 20km A type 20B: WDM 20km B type 40A: WDM 40km A type 40B: WDM 40km B type
60A: WDM 60km A type 60B: WDM 60km B type 80A: WDM 80km A type 80B: WDM 80km B type

www.ctcu.com CTC UNION TECHNOLOGIES CO., LTD. FRM220-Serial 1-36


Multi-Service Platform - Fiber Modem / Converter

RS-485 4 wires (Full duplex)


* For RS-485 4 wires operation, TX+. TX- , RX+ and RX- are connected

Pin 1 Pin 1 Pin Signal Connection


1 NC
2 RS-485 Out +
Pin 2 TX+ Pin 2 TX+ 3 RS-485 Out -
RS-485 Termination is used to match impedance of a node Pin 3 TX-
Pin 4 RX+
Pin 3 TX-
Pin 4 RX+
4 RS-485 In+
to the impedance of the transmission line being used. When Pin 5 RX- Pin 5 RX- 5 RS-485 In-
impedances are mismatched, the transmitted signal is not 6 NC
completely absorbed by the load and a portion is reflected * For RS-485 4 wires Dip Switch Setting
back into the transmission line. This reflection may cause errors
Pin Function description Dip Switch Setting
in the data. Termination resistors should be placed only at the
1 Interface Setting Off
extreme ends of the data line, and no more than two
2 Interface Setting Off
terminations should be placed in any system.
3 RS-485 TX Termination On
4 RS-485 RX Termination On
5 1K Ohm Pull-up Off
6 1K Ohm Pull-Down Off

*On enable RX(-) pull down **On enables RX(+) pull down

RS-485 2 wires (Half duplex) RS-422 4 wires


* For RS-485 2 wires operation, RS-485(+) and RS-485 (-) are connected * For RS-422 4 wires operation, TD+(A), TD-(B), RD+(A) and RD-(B) are connected

Pin 1 Pin 1 Pin Signal Connection


Pin 1 Pin 1 Pin Signal Connection
1 NC
1 NC
2 NC
2 RS-422 Out+ (A)
Pin 4 RS-485+ Pin 4 RS-485+ 3 NC
Pin 2 Data output+(A) Pin 2 Data output+(A) 3 RS-422 Out– (B)
Pin 5 RS-485- Pin 5 RS-485-
4 RS-485 (+) Pin 3 Data output-(B) Pin 3 Data output-(B) 4 RS-422 In+ (A)
Pin 4 Data input +(A) Pin 4 Data input +(A)
5 RS-485 (-)
Pin 5 Data input –(B) Pin 5 Data input –(B) 5 RS-422 In- (B)
6 NC
6 Signal Ground
* For RS-485 2 wires Dip Switch Setting * For RS-422 4 wires Dip Switch Setting
Pin Function description Dip Switch Setting
Pin Function description Dip Switch Setting
1 Interface Setting On
1 Interface Setting Off
2 Interface Setting Off
2 Interface Setting Off
3 RS-485 TX Termination Off
3 RS-485 TX Termination Off
4 RS-485 RX Termination On
4 RS-485 RX Termination Off
5 1K Ohm Pull-up Off
5 1K Ohm Pull-up Off
6 1K Ohm Pull-Down Off
6 1K Ohm Pull-Down Off

RS-232 5 wires RS-232 3 wires


* For RS-232 5 wires operation, TD, RD, and SG are connected, plus 1 handshaking pair * For RS-232 3 wires operation, only TD, RD, and SG are connected

Pin 1 Pin 1 Pin Signal Connection Pin 1 Pin 1 Pin Signal Connection
1 NC 1 NC
2 RS-232 RTS/CTS In 2 NC
Pin 2 Flow control Input Pin 2 Flow control Input 3 RS-232, Data out Pin 3 Data output Pin 3 Data output 3 RS-232, Data out
Pin 3 Data output Pin 3 Data output 4 RS-232 RTS/CTS Out Pin 5 Data input Pin 5 Data input 4 NC
Pin 4 Flow control output Pin 4 Flow control output Pin 6 Signal ground Pin 6 Signal ground
Pin 5 Data input Pin 5 Data input 5 RS-232 Data in 5 RS-232 Data in
Pin 6 Signal ground Pin 6 Signal ground
6 Signal Ground 6 Signal Ground
* For RS-232 5 wires Dip Switch Setting * For RS-232 3 wires Dip Switch Setting
Pin Function description Dip Switch Setting Pin Function description Dip Switch Setting
1 Interface Setting Off 1 Interface Setting On
2 Interface Setting On 2 Interface Setting On
3 RS-485 TX Termination Off 3 RS-485 TX Termination Off
4 RS-485 RX Termination Off 4 RS-485 RX Termination Off
5 1K Ohm Pull-up Off 5 1K Ohm Pull-up Off
6 1K Ohm Pull-Down Off 6 1K Ohm Pull-Down Off

1-37 FRM220-Serial CTC UNION TECHNOLOGIES CO., LTD. www.ctcu.com