0% found this document useful (0 votes)
229 views2 pages

Microsense II - 5810: Non-Contact Capacitance Gauging Module For High Dynamic Applications

The Microsense II-5810 is a non-contact capacitance gauging module designed for high dynamic applications like analyzing high RPM mechanisms. It provides nanometer resolution displacement measurements at bandwidths up to 100 kHz. Key features include selectable filters, analog output, and individual unit calibration using laser interferometry traceable to NIST standards. The module is designed for easy integration and customization for applications requiring high-precision, high-speed gauging and sensing.

Uploaded by

asim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
229 views2 pages

Microsense II - 5810: Non-Contact Capacitance Gauging Module For High Dynamic Applications

The Microsense II-5810 is a non-contact capacitance gauging module designed for high dynamic applications like analyzing high RPM mechanisms. It provides nanometer resolution displacement measurements at bandwidths up to 100 kHz. Key features include selectable filters, analog output, and individual unit calibration using laser interferometry traceable to NIST standards. The module is designed for easy integration and customization for applications requiring high-precision, high-speed gauging and sensing.

Uploaded by

asim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Microsense II - 5810

Non-Contact Capacitance Gauging Module


for High Dynamic Applications
Features
Applications
Non-contact capacitive displacement
measurements and sensing Ultra-high RPM mechanism analysis

Nanometer resolution at high bandwidths Hard Disk Drive motors


Rotary spindle applications
100 kHz bandwidth Machine tool performance analysis
100K+ RPM applications
Selectable filters for maximum resolution High speed air bearings

External low noise power supply High volume OEM gauging applications

Industry standard analog output Precision dimensional gauging

Designed for High Dynamic Displacement High-frequency, high-resolution slide and


Gauging and Sensing Applications spindle runout analysis

Non-contact capacitive Non-contact displacement measurements High-resolution vibration analysis


displacement measurements
Easy to integrate into OEM test and Fast Tool Servo-loop positioning system
Nanometer resolution at measurement systems feedback
100 kHz bandwidth
High performance Predictive maintenance transducers

Industry Standard output


Designed for adaptability to many Operating Ranges

Selectable filters for maximum applications


Operating range is preset at factory for
resolution selected probe. Range may be additionally
Single analog output
amplified by means of internal jumpers.
Analog meter for easy set up
Downloadable calibrations
Custom Configurations
Uses Standard 5000 Series Custom sensors readily available
Probes Available for multiple unit orders. Contact
High / Low limit outputs factory.

Laser Calibration

High precision individual unit calibration at


factory using Microsense developed laser
interferometry system. Calibration traceable
to NIST. Performance graph included.

www.microsense.net
5810 - Specifications

Performance Adjustments / Indicators

Measurement Range Front Panel Adjustments

± 25 µm to ± 1000 µm full scale, depending Calibration adjustment for scale factor


on probe selection Offset adjustment for zero setting
Limit settings
Measurement Resolution
Front Panes LED Indicators
Typical resolution is better than 2 nm (r.m.s.) @ 1 kHz.
+ Limit, - Limit
Typical Resolutions (nm, r.m.s)

Sensor ø Range Bandwidth Resolution Physical Dimensions


(mm) (± um) (kHz) (nm)
0.5 25 1 0.5 18 cm- L x 11 cm-W x 4 cm-H
0.5 50 20 2.2 (7.0" x 4.25" x 1.5")
2.0 125 1 1.7
2.0 250 100 22.3
5.0 250 5 2.9 Weight
5.0 500 1 5.7
1 kg (2.2 lbs)
Linearity

Typically 0.25% over full scale range, Operating Environment


depending on probe model and operating range.
Temperature
Stability
5O C to 50O C (41O F to 122O F)
O
Typically better than 200 ppm per C over
temperature range of 15O C to 35O C. Humidity

Bandwidth 0 to 95% RH, non-condensing

Jumper selectable from:


1 kHz, 5 kHz, 20 kHz, 100 kHz Power Requirements

Inputs / Outputs 90-240 VAC

Standard Microsense Universal Low Noise Power Supply


Probe Input
with IEC Connector included with Module
Single, accepts Series 5000 probe family

Analog Output

Single & differential, preset ± 10 volts for full scale


range. Jumpers set output scaling and
bipolar/unipolar output.

Limits

User adjustable digital outputs for detecting overrange


and measurement limits
Microsense LLC
70 Industrial Ave E.
Lowell, MA 01852
Main Tel (978)843-7670
Fax (978)856-3375
Microsense LLC (specifications subject to change without notice)
REV 092904

www.microsense.net