Activity No. 1: Design Criteria and Requirements Program Outcomes (Pos) Addressed by The Activity
Activity No. 1: Design Criteria and Requirements Program Outcomes (Pos) Addressed by The Activity
1.5. Procedures/Instruction
The activity comprises of the following steps:
A. Plans
1. Assume that you are a construction firm. Come up with a name to your company as agreed by
the group.
2. Given a complete building design sample, draw your own building design as specified below:
a. Architectural Plan
b. Structural Plan
3. Consider the standards and codes specified in the NBC for your assigned design project.
B. Design Specifications
1.Indicate all design specifications related to the structural and architectural plans of your
project.
2. Provide detailed summary of important specifications needed in completing the project.
FO-ACAD-SDE-00X/20MAR2020/REV.0
C. Design Requirements
1. Provide the following compliance requirements for any project:
Safety
Sanitation/Environmental
Sustainability/Technical Capacity
2. These requirements can be borrowed from actual construction firms
3. Provide company information, registration, and license to operate.
The height shall be measured from the highest adjoining sidewalk or ground surface:
Provided, that the height measured from the lowest adjoining surface shall not
exceed such maximum height by more than 3.00 meters:
Except, that towers, spires, and steeples, erected as part of a building and not
used for habitation or storage are limited as to height only by structural design
if completely of incombustible materials, or may extend not to exceed 6.00
meters above the height limits for each occupancy group if of combustible
materials.
FO-ACAD-SDE-00X/20MAR2020/REV.0
IX. SECTION 1003: Projection of Balconies and Appendages over Streets
The clearance between the established grade of the street and/or sidewalk and the
lowest under surface of any part of the balcony shall not be less than 3.00 meters.
FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 2: Architectural Plan (Floor Plan)
FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 3: Architectural Plan (Tile Layout)
FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 4: Architectural Plan (Elevation)
FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 5: Architectural Plan (Section)
FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 7: Architectural Plan (Schedule of doors and Windows)
FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 8: Structural Plan
1
0
FO-ACAD-SDE-00X/20MAR2020/REV.0
1
1
FO-ACAD-SDE-00X/20MAR2020/REV.0
1
2
FO-ACAD-SDE-00X/20MAR2020/REV.0
1.6.3. Observation
1
3
FO-ACAD-SDE-00X/20MAR2020/REV.0
IV. Light and Ventilation
The location of the townhouse shows that it is facing a street creating the optimal flow of
light and air.
V. Ceiling Heights
The total height measured from the ground floor finishing level to the tip of the concrete
roof is 8.45 m. For the first floor of the townhouse, which has approximately 3 m height,
the second floor, which has approximately 3 m height, and lastly, the roof deck has
approximately 2.45 m height. The buildings' heights were acceptable to the requirement
of NBC Section 805; to have a minimum of 2.70m for the first storey, 2.40m for the
second storey, and 2.10m for the succeeding storeys.
1
4
FO-ACAD-SDE-00X/20MAR2020/REV.0
DIMENSIONS QUANTITY FLOOR TOTAL
(m2) AREA (m2)
(m2)
First Floor:
Toilet and Bathroom 2.0 x 2.0 2 4 8
Living Area (left side) 3.1 x 5.5 1 17.05 17.05
Living Area (right side) 3.1 x 4.5 1 13.95 13.95
Dining area with 3.1 x 5.5 1 17.05 17.05
Kitchen
(left side)
Dining area with 3.1 x 4.5 1 13.95 13.95
Kitchen
(right side)
Second Floor:
Bedroom 3.1 x 3.2 2 9.92 19.84
Master’s Bedroom 5.5 x 3.1 1 17.05 17.05
(left side)
Master’s Bedroom 4.5 x 3.1 1 13.95 13.95
(right side)
Toilet and Bathroom 2.0 x 2.01 1 4.02 4.02
(left side)
Toilet and Bathroom 2.0 x 1.425 1 2.85 2.85
(right side)
Roof Deck:
Toilet and Bathroom 2.0 x 2.01 1 4.02 4.02
(left side)
Toilet and Bathroom 2.0 x 1.425 1 2.85 2.85
(right side)
1
5
FO-ACAD-SDE-00X/20MAR2020/REV.0
1
6
FO-ACAD-SDE-00X/20MAR2020/REV.0
VII. SECTION 808: Window Openings
In accordance with the National Building Code of the Philippines, windows of the room
are provided with a total floor area of 10 m and approximately 3 m for the window
openings. All windows are disclosed in public compliance.
1
7
FO-ACAD-SDE-00X/20MAR2020/REV.0
The proposed plan of the house has complied with all the requirements as stated on the
National Building Code of the Philippines and shall not exceed to the maximum allowable
space provided. Considering the parking space to ensure that no part of the house shall
project beyond the property line.
1
8
FO-ACAD-SDE-00X/20MAR2020/REV.0
X. SECTION 1007: Doors, Windows and the Like
In line with standards of the National Building Code of the Philippines, the doors,
windows, and the like comply in less than 2.40 meters above the pavement or ground line.
Correspondingly the main entrance of a two-story townhouse has a measure of 1.2 m in
height above the ground line.
1
9
FO-ACAD-SDE-00X/20MAR2020/REV.0
The construction quality and material used for the excavation foundation, and walls
conforming to the NBC 1202. Therefore, those were assumed to be accepted relying on
their soil bearing potential.
1.6.4. Conclusion
The Design Criteria and the Building Codes or standards acted as the guidelines when
planning and creating a safe, sustainable and desirable living space or buildings. It served as
like the backbone in the designing process where we take into consideration the standards to
achieve an ideal and safe plan. In this activity we were able to familiarize ourselves with the
building codes of different sections and learned how to work through and incorporate these
criteria and standards in designing the building. We can further improve the plan by studying
more these criteria and understanding more each plan/layout and learning how these work
well with each other. By considering the standard specifications and incorporating it to the
preference, we were able to come up with an ideal and desirable living space that takes into
consideration the safety, sustainability and long-term