PROFIS Anchor 2.

1
OVERVIEW

SEISMIC PROVISIONS

ANCHOR REINFORCEMENT

REDUCED EDGE DISTANCE

DESIGN REPORT

CANADA

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1

KEY CHANGES IN PROFIS ANCHOR 2.1 FOR U.S.A.


 Update to ACI 318-08 provisions
• seismic provisions
• anchor reinforcement provisions
 Detailed information in Design Report
• equations
• variables
• calculations

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1

KEY CHANGES IN PROFIS ANCHOR 2.1 FOR CANADA.


 Phase out PROFIS version 1
• no longer available in Canada

 Replace PROFIS version 1 with PROFIS Anchor 2.1.


• new graphics and user interface
• more user friendly
• Hilti ASD and CSA A23.3 calculations

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1
Minor Updates per ACI 318-08
h,v : modification factor for large edge distance / thin concrete member

PA2.1 includes this value in its calculations.

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1
RD.5.4.2 – In determining nominal side-face blowout strength for multiple headed anchors, only those anchors close
to an edge ( hef > 2.5ca1 ) that are loaded in tension should be considered. Their Strength should be compared to the
proportion of the tensile load applied to those anchors.

calculation results

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1
detailed calculation summary for
stand-off applications

PA2.1 considers the shear load due to bending (stand-off) as a Design Strength.

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1

UPDATES BECOME AVAILABLE

 Message alerting you to an update will appear.

 Click “Yes” and follow instructions.

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010


PROFIS Anchor 2.1
UPDATE WHILE USING PROFIS ANCHOR

 Click on the wrench icon located in the upper left part of the
main screen.

 Click on “Resources”.

 Click “Check for Updates”.


 Follow the instructions.
www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010
PROFIS Anchor 2.1
UPDATE VIA AUTO UPDATE

 Right click on the AutoUpdate button.

Click “open”.

 Check box next to “Hilti PROFIS Anchor” for Updates.


 Download if new update is available.

 Click on Changes to view update information.

www.hilti.com R.T. Morgan | PA2.1 – Overview | October 2010

You might also like