Model: EN1811

32A, 400V 3ph Wye

Input Metered PDU Data Sheet – EN2.0 Series


The EN1811 Input Metered PDU includes energy metering with advanced power and environmental
monitoring options. Metering at the phase input and internal circuit breaker levels allow
comprehensive overload monitoring and advanced alerts, while billing-grade watt-hour metering
provides accurate power consumption data for energy use optimization and change management.
Advanced network management features allow for a variety of remote access methods and integration
with accessories including environmental monitoring and security access solutions.

PDU Function

Metering Attributes Voltage(V), Current(A), Apparent Power(kVA), Real


Power(kW), Power Factor, Energy (kWh)
Metering Accuracy ± 1% to ISO/IEC 62052-21
Metering Locations Input phase, circuit breaker, and outlet-level measurements
Remote Outlet Switching No
Electrical Input
Acceptable input voltage 400V 3ph Wye
Input current (phase) 32A
Input frequency 50/60 Hz
Max Input power 23.0 kVA @ 240 VAC
Electrical Output
Output voltage 230 V
Maximum output current (phase) 32A
Overload protection (internal) (6) 1-pole, 16A hydraulic-magnetic circuit breakers
Outlet configuration (30)C13, (12)C19
Physical
Chassis Dimensions (L x W x D) in 68.9 x 2.17 x 2.09
Depth at circuit breaker, in 2.953
Input cord length 10'
Environmental
Operating Temperature -5 to 60°C (23 to 140°F)
Storage Temperature -20 to 60°C (-4 to 140°F)
Humidity (operating/storage) 5-90% RH / 5-95% RH; non-condensing
Max operating elevation, above MSL 3,000 m (9,840 ft)
Compliance
Safety & Environmental CE, Demko Certified to IEC/EN60950-1, RoHS, REACH
Model: EN1811
32A, 400V 3ph Wye

Advanced Network Management Module – EN2.0 Series


Network Connectivity

Network Connectivity Dual ports: 1x Gigabit Ethernet (10/100/1000 Mbps) and 1x (10/100 Mbps)
connection/IP address
Ethernet Cascading Up to 64 units share a single “daisy-chain” Ethernet connection/IP address
DC Power Sharing Each PDU can provide DC power sufficient to power network management electronics
Dual Ethernet Support and
Dualsensors in ports
Ethernet a neighboring PDU in
for redundant the event
network of AC power source loss
communications
Dual Network Access Dual network connectivity allows redundancy and/or multiple stakeholder connectivity
Remote Connectivity for up to iPV4
HTTP(s), 64 units
and in Ethernet
iPV6, Telnet,cascading mode
SSH, Virtual Serial, SNMP (v1, v2c, v3), JSON-RPC,
WebUI Interface LDAP(S), FTP/SFTP,
Data efficient REACTRADIUS, Redfish
framework withDMTF
nativeRESTful
mobileAPI
device support
Management Module Attributes
Microprocessor/Memory Cortex A-5
Field Replacement Hot swap replaceable module; fast plug-and-play connectivity
Module Orientation Tool-less removal and 180⁰ install capable for top or bottom power cord orientation

User Display Dual Displays: large high visibility LED display for key metering information and alarms.
Low-power graphical oLED with user controls for local information.
Display Language English, Spanish, German, French, Italian, Korean, Japanese, Chinese (simplified)
Lighted Color Code User programmable color border allows power source identification by PDU
Sensor & Supports up to 8 digital sensors for environmental sensors and/or electronic locks

High Visibility Data Display Critical Alarm Alerts


PDU Alarm
Cascade Error
Environmental
Alarm
Security Alarm
Circuit Breaker
Phase Level CB Level Alarm
Source Color Coding
(User Selected Option)
USB-C
(upgrades, connectivity, and User Interactive Display
future-proof expansion) (for setup and detailed information)

10/100/Gigabit Ethernet Port


(primary network port) 10/100 Ethernet Port
(for redundancy and Ethernet
Digital Sensor Port 1 cascading)
(supports up to 8 physical Digital Sensor Port 2
sensors)
Model: EN1811
32A, 400V 3ph Wye

Overcurrent Protection

Circuit Breaker Configuration


Circuit Breaker Type (6) 1-pole, 16A hydraulic-magnetic circuit breakers (temperature stable)
Circuit Interrupt Rating 5,000 Amps (UL489)
Circuit Breaker Trip Curve Sensata Trip Curve 62/Carling Trip Curve 24
Inrush Pulse Tolerance 10 times rated current (approx.)
Dielectric Strength 3,750 VAC, 60Hz, 60 seconds between all electrically isolated terminals
Vibration Shall not trip when vibrated to MIL-STD-202, Method 204, Condition A, 100% load
Temperature Rating -40 to 85°C (-40 to 185°F) Ambient
Handle Off Guard Yes, protects against accidental user actuation to OFF position
Model: EN1811
32A, 400V 3ph Wye

Environmental Sensors
EA9102 Single Temperature Probe
EA9103 Temperature and Humidity Combo Sensor
EA9105 3x Temperature and Humidity Combo Sensor
EA9106 Sensor Input Hub (3 sensors input to PDU)
EA9109 Magnetic Door Switch (open/close)
EA9110 Dry Contact Cable (for third party sensors)
EA9111 Spot Fluid Leak Sensor
EA9112 Rope Fluid Leak Sensor
EA9116 Smoke Alarm Sensor

Warranty and Terms


Warranty

CIS Global warranties Enlogic brand equipment provided shall be free from manufacturing defects for a period of five (5)
years from the invoice date to the original purchaser. For full warranty details, please visit www.enlogic.com/warranty.
Disclaimer
Copyright © 2019, CIS Global LLC and/or its affiliates. All rights reserved. This document is provided for
information purposes only and current at the time of publishing; the contents hereof are subject to change
without notice. This document is not warranted to be error-free, nor subject to any other warranties or
conditions, whether expressed orally or implied in law, including implied warranties and conditions of merchantability or
fitness for a particular purpose. We specifically disclaim any liability with respect to this document, and no contractual
obligations are formed either directly or indirectly by this document. This document may not be reproduced or transmitted
in any form or by any means, electronic or mechanical, for any purpose, without our prior written permission. Enlogic is
registered trademark of CIS Global LLC and/or its affiliates.
or implied in law, including implied warranties and conditions of merchantability or fitness for a particular purpose. We
About CIS
CIS Global has delivered superior product development, manufacturing, and logistics management since 1955 to small
and large customers across the globe. We specialize in data center products including mechanical motion and power
management solutions. As world market share leader in precision server rails and OEM market share leader in PDUs, CIS
designed and built products are found in nearly every data center worldwide.
CIS has more than 20 years’ experience manufacturing more than 2-million best-in-class PDUs. CIS acquired Enlogic in
2015 and remains dedicated to providing the industry’s most innovative power management solutions build with the
highest manufacturing quality.