60 Adhesive Kit
Epoxy siloxane electrically conductive adhesive for bonding fiberglass pipe and fittings

Description The PSX-60 epoxy adhesive kit contains an adhesive resin, hardener, mixing spatula, rubber
gloves, and assembly instructions. The adhesive resin is a red paste with sand filler. The
adhesive hardener is a white paste. The mixed adhesive color is red. PSX-60 is a two-part epoxy
siloxane adhesive formulated for permanently bonding Quick-Lock® or taper-taper joints on
fiberglass-reinforced pipe and fittings. PSX-60 can be used to connect most epoxy, vinyl ester
and phenolic piping systems.

Instructions Prior to handling, read all Toxicity, Precaution and First Aid information below. Before mixing the
adhesive, ensure that the bonding surfaces are correctly prepared and are clean and dry. Open
the resin and hardener containers. Using the mixing spatula, scrape all of the hardener into the
resin container. Mix the resin and the hardener with the spatula for at least 60 seconds . Scrape
the sides, bottom and lid of the resin container occasionally to get all of the hardener into the
mix. Never attempt to split a kit or heat the hardener. The resin and the hardener have been
packaged at the correct ratio for optimum adhesive performance.
Apply a uniform coat of the mixed adhesive to both bonding surfaces and draw the parts firmly
together. Detailed joint assembly instructions may be found in Quick-Lock Installation
Instruc- tions, and Bell x Spigot Installation Instructions.

Pot Life and For installations with service temperatures below 180°F (82°C) and pressures below 150 psi
Cure Time (1.03 MPa), PSX-60 bonds can be put into service with ambient temperature cures as indicated
in the table (See page 2 of this section.). However, it is highly recommended that an external
heat source be used to force cure the adhesive. The adhesive and bonding surfaces should be
warmed to 70°F (21°C) prior to mixing and applying the adhesive. Adhesive may be force cured
using an NOV Fiber Glass Systems approved heating blanket. The table also indicates the pot
life (working time) of the adhesive atvarious temperatures . The pot life is the time from the initial
mixing of the resin and hardener until the adhesive in the container begins to thicken and is no
longer usable.

For systems with anticipated service temperatures above ·180°F (82°C) or operating pressures
over 150 psi (1.03 MPa), or when installing any system at ambient temperatures below 40°F
(5°C), the adhesive joint must be cured with an external heat source . A heat cure using an NOV
Fiber Glass Systems approved electric heating blanket is recommended. The heat cure may be
applied at any time after the bond is made and before theline is tested or put into service. The
heat may be applied immediately after making the bond while the adhesive is still liquid or after
it has gelled to a solid.

Minimum cure times of 30 minutes for 1 through 6 inch pipe and 45 minutes for 8 through 16 inch
lines are recommended. Even after the adhesive has solidified at ambient temperatures, heat
curing will enhance ' the chemical cross-linking of the adhesive, increasing the strength ,
temperature resistance and corrosion resistance of the adhesive. When used in fire protec- tion
service all joints must be force-cured with an external heat source regardless of ambient
temperature.

40 5 70 12 11
60 16 40 7 6
70 21 30 5 4
80 27 20 4 3
100 38 8 3 2
(1) At temperatures below 4O"F (5'C) an external heat source must be used to force cure the adhesive.
The adhesive and the bonding surfaces should be warmed to 70'F (21'C) before mixing and applying the
adhesive. Adhesive may be force cured using an approved electric heating blanket when using adhesive at
ambient temperatures above 100'F (38'C), make provisions to keep adhesive cool to extend pot life.
(2) Times indicate when cure is sufficient to permit moving the bonded joint. The minimum joint cure time
must elapse prior to hydro testing.

1NVtIVII.fgspipe.colTI - fgspipe@nov.colTI

iberGlassSystems

Adhesive Kit PSX·60 adhesive kits are available in 3 fluid oz. and 6 fluid oz. sizes. The values in this table are based
Sizes and on the quantity of adhesive required by an experienced crew working at a temperature of 80°F (27°C).
Bonds Per Kit

Quick-Lock Joints

Storage Do not store kits in areas above 100°F (38°C) or below 32°F (O°C) , or in the direct sunlight in warm
weather. In cold weather warm the resin to at least 70°F (21°C) but not above 100°F (38°C) to permit
good mixing and easier application. Do not use adhesive past its expiration date.

Toxicity and
Hardener: The hardener is irritating to skin, eyes and respiratory tract. It is toxic orally and may cause
Precautions
sensitization. Avoid contact with eyes, skin or clothing. Avoid breathing vapors . Wear rubber gloves,
protective apron and NIOSH approved respirator. Wash thoroughly after handling.

Resin: The resin may be mildly irritating to skin, eyes and respiratory tract. Avoid contact with eyes, skin
or clothing. Avoid breathing vapors. Wear rubber gloves and eye protection. Wash thoroughly after
handling.

First Aid In case of contact


Call Chern Tel for chemical

Eyes: Immediately flush eyes with plenty of water


emergencies, spills:

for at least 15 minutes. Call a physician.


Skin: Wash skin with soap and water.
Hotline/MSDS Fax Access

Clothing: Remove contaminated clothing and wash


800-255-3924

before reuse.
Inhalation: Remove to fresh air. Give oxygen or artificial
Internationally:

respiration if necessary.
Call +01-813-248-0585

Ingestion: If catalyst is swallowed and person is conscious,


give plenty of water or milk to drink.
Do not induce vomiting. Call a physician. If
resin is swallowed, give 100 grams (about % Ib)
activated charcoal slurry in water.
Do not induce vomiting. Call a physician.

North America South America Europe Asia Pacific Middle East


17115 San Pedro Ave. Suite 200 Estrada de Acesso Ii Zona P.O. Box 6, 4190 CA No. 7A, Tuas Avenue 3 P.O. Box 17324
San Antonio, Texas 78232 USA Industrial Portuana deSuape, sIno. Geldermalsen, The Netherlands Jurong, Singapore 639407 Dubai, UAE
Phone: 210477 7500 Recife, PE, Brazil 55.590-000 . Phone: 31 346 587 587 Phone: 65 6861 6118 Phone: 971 4881 3566
Phone: 55 31 3501 0023

\N\NW".fgspipe.coln • fgspipe@nov.col1'l

KeY FiberGlassSystems

©2013 National Oilwell Varco. Allrights reserved.


ADH4720 February 2013

You might also like