DTS 2500 1209 Eng
DTS 2500 1209 Eng
DTS 2500 1209 Eng
Main characteristics
• Double configurable input for
strain gauge / potentiometer /
linear signal / TC / RTD
• Two auxiliary analog inputs
• Differential measurement
• High precision: 0.1 % f.s. ± 1 digit
• Automatic calibration for 6-wire
strain gauge
• Transmitter power supply and
strain gauge probe power supply
• PID controls with 8 sets of selectable
parameters
• 4 configurable alarms, failsafe function
• up to 3 isolated analog outputs for control
Main applications and retransmission
• Pressure controls on extrusion • 4 digital inputs
and injection press lines for • 4 relay outputs with configurable function
plastics • expansion with 4 configurable digital
• Differential pressure control inputs and/or outputs
• Strength control on textile, • Serial communication interface:
paper, plastic film production - RS485/RS 232 MODBUS RTU protocol
lines (optional)
• Tension control on winding - Profibus DP Slave (optional)
stations • Front panel with three 5-digit displays and
• Control process two bar graphs
DESCRIPTION FACEPLATE
Blue
2-wires 4-wires
c (control output 1, 2)
+ control output 2
+ control output 1
2-wire 3-wire
connection connection
(*) PT100 for possible
external cold junction
compensation
Potentiometer
Potentiometer
R ≥ 100Ω
IN1 IN2
Model with double main input
Strain-gauge Strain-gauge
Model: 2500 - 1 - X - X - X - X - X
Green Green
White White
Black or Yellow
power supply
90-260Vac / 10-30Vac/dc Red
max. 15VA; 50/60Hz
Black or Yellow
Red
probe supply
Input in current / voltage Input in current / voltage
Thermocouple Thermocouple
2-wires 4-wires
c (control output 1, 2)
+ control output 2 (*) PT100 for possible (*) PT100 for possible
external cold junction external cold junction
+ control output 1 compensation compensation
Potentiometer
Potentiometer Potentiometer
R ≥ 100Ω R ≥ 100Ω
96 115
108 96
115
92
170
92
10
ORDER CODE
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
The instrument conforms to the European Directives 2004/108/CE and 2006/95/CE with reference to the generic standards:
EN 61000-6-2 (immunity in industrial environment) - EN 61000-6-3 (emission in residential environment) - EN 61010-1 (safety)