Second Basement Plan AR OT: or Any Portion Thereof Is Reserved by The Architects
Second Basement Plan AR OT: or Any Portion Thereof Is Reserved by The Architects
Second Basement Plan AR OT: or Any Portion Thereof Is Reserved by The Architects
A B C D D1 E F F1 G H R5A I J J1 K L L1 M N O P Q
J E C A F K
A. GENERAL NOTES :
ALL LEVELS INICATED ARE REFERENCED TO THE SURVEYOR'S DATUM POINT
1. ALL STRUCTURAL, ELECTRICAL, CIVIL, INTERIORS AND LANDSCAPING QUERIES ARE TO BE
REFERENCED TO THE RELEVANT CONSULTANTS DRAWINGS, SPECIFICATIONS AND DETAILS.
2. ALL PLUMBING QUERIES ARE TO BE REFERRED TO THE RELEVANT SPECIALIST CONSULTANT
DRAWINGS, SPECIFICATIONS & DETAILS.
3. ALL CONCRETE COLUMNS AND STRUCTURE TO STRUCTURAL ENGINEERS DETAILS &
SPECIFICATIONS.
4. ALL SPECIFICATIONS WITH REGARD TO FIRE REGULATIONS, TO BE REFERRED TO CONSULTANTS
DETAILS AND SPECIFICATIONS.
5. ANY DISCREPANCY IN THE DRAWINGS, DIMENSIONS & SPECIFICATIONS TO BE BROUGHT TO THE THE
ATTENTION OF THE CONSULTANT AND THE ARCHITECT PRIOR TO ANY WORK BEING PUT IN HAND.
6. DIMENSIONS - ONLY FIGURED DIMENSIONS TO BE FOLLOWED, NO SCALING OF DRAWINGS WILL BE
17 17
PERMITTED.
BLOCKWORK WALLS
PAINT 7. IN CAVITY WALLS BUILD FULL HEIGHT 200mm. WIDE BLOCKWORK PIERS.
STORE 8. IN CAVITIES EXCEEDING 115mm., ALLOW FOR 15mm. JOINT BETWEEN DIAPHRAGM PIER AND
ADJOINING FACE.
CHIEF ASSISTANT ENG HOTEL ENGINEER'S 9. TIES TO BE SUPPLIED TO DIAPHRAGM PIERS, AS PER STRUCTURAL ENGINEERS SPECIFICATIONS.
ENGINEER'S AND SECRETARY'S STORE ROOM MACHINE 10. PROVIDE MOVEMENT JOINTS WHERE INDICATED ON DRAWINGS MARKED UP BY SITE ENGINEER.
11. ALL BLOCKWORK BUILT BUTTING UP TO CONCRETE COLUMNS TO BE FIXED TO FACE OF COLUMN
OFFICE OFFICE ROOM WITH STAINLESS "HOOP IRON" STRAPS TO STRUCTURAL ENGINEER'S DETAILS.
MACHINE 12. SUPPLY STAINLESS STEEL WALL TIES IN ALL CAVITY WALLS TO STRUCTURAL ENGINEERS
SPECIFICATION.
008 009 010 011 012 013 014 015 016 017
ROOM 13. ALL EXTERNAL WALLS TO BE SUPPLIED WITH DPM TO INTERNAL SKIN, PLUS 50mm. INSULATION IN
CAVITY.
B. STRUCTURAL NOTES :
1. DRAWINGS ISSUED BY DSA FOR CONSTRUCTION TO SITE ARE WITHOUT STRUCTURAL ENGINEERS
NOTES FOR LINTOLS AND BEAMS OVER OPENINGS AND RECESSES.
2. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE DRAWING ISSUED BY THE STRUCTURAL
16 16 ENGINEER WITH NOTES FOR LINTOLS, BEAMS, MOVEMENT JOINTS ETC.
C. CONTRACTOR NOTES :
CONTRACTOR TO RECONFIRM ALL SALIENT LEVELS WITH MUNICIPALITY PRIOR TO COMMENCEMENT
R5A OF WORK
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CO-ORDINATION OF ALL SERVICES BEFORE
ANY WORK COMMENCES.
SCALE 1:50 2. THE CONTRACTOR SHALL COMPLY WITH ALL CIVIL DEFENCE REGULATIONS
H H 3. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING
SERVICES AND SPECIALISED ITEMS AND INCORPORATE THE DUCTS TO CONCEAL NECESSARY PIPES,
R5
CAR PARKING R6
CABLES AND CONDUITS ETC. FOR THE CONSULTANTS APPROVAL PRIOR TO COMMENCEMENT OF
WORK.
FHR 4. THE CONTRACTOR SHALL INSPECT THE SITE PRIOR TO ANY WORK BEING PUT IN HAND AND TAKE
INTO CONSIDERATION ALL ASPECTS OF THE WORKS, TO BE CARRIED OUT INCLUDING ANY
DEWATERING, IF REQUIRED. ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED ON SITE PRIOR TO
ANY WORK BEING PUT IN HAND. ALL SETTING OUT IS THE CONTRACTOR'S RESPONSIBILITY.
5. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES IN THE DRAWINGS, DIMENSIONS AND
MAINTENANCE SPECIFICATIONS TO THE CONSULTANT AND THE ARCHITECT PRIOR TO ANY WORK BEING PUT IN
007 R4A R6A
17 PARKING BAYS 005 WORKSHOPS 6.
HAND.
ALL EQUIPMENT SHALL BE TO THE APPROVAL OF THE LOCAL CIVIL DEFENCE DEPARTMENT.
15A 15A
7. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH FINISHES AND SPECIFICATION DOCUMENTS.
14
KNOWLEDGE & 14
CONCRETE WALL
T
AF
GAS TANKS
MALE WASH & CHANGE ROOM WARE/GLASS
SH
WASH 3HR FULL HEIGHT FIRE RATED AUTOCLAVED AERATED
E
004
C
CONCRETE (AAC) WALL
I
RV
SE
2HR FULL HEIGHT FIRE RATED AUTOCLAVED AERATED
CONCRETE (AAC) WALL
1HR FULL HEIGHT FIRE RATED AUTOCLAVED AERATED
13A 13A CONCRETE (AAC) WALL
STANDARD FULL HEIGHT AUTOCLAVED AERATED CONCRETE
(AAC) WALL(30 MIN. FIRE RATING)
003 STANDARD FULL HEIGHT AUTOCLAVED AERATED CONCRETE
RB
STAFF
R3 R8 (AAC) WALL (NO FIRE RATING)
DINING ROOM
FULL HEIGHT ACOUSTIC AND MOISTURE RESISTANT (BATHRM
72 SEATS
GENERAL SIDE) GYPSUM PARTITION WALL . TO HAVE 30 MINUTE FIRE
JANITORS RESISTANCE WHEN USED AS A BARRIER BETWEEN GUEST
STOREROOM ROOMS AND BETWEEN GUEST ROOMS AND CORRIDORS.
13 OFFICE 13
FULL HEIGHT ACOUSTIC (SOUND INSULATED) GYPSUM
002 PARTITION WALL . TO HAVE 30 MINUTE FIRE RESISTANCE WHEN
DRIVEWAY USED AS A BARRIER BETWEEN GUEST ROOMS AND BETWEEN
GUEST ROOMS AND CORRIDORS.
FULL HEIGHT MOISTURE RESISTANT ( BATHROOM SIDE)
004 X GYPSUM PARTITION WALL
CORRIDOR
FULL HEIGHT GYPSUM PARTITION WALL
001
PRAYER ROOM STONE WALL CLADDING
PRESSURIZATION
SHAFT FHR CUPBOARD
MEP F.E. STAIR 01
R1 04 SHAFT R10
LAUNDRY
09 09
FHR CUPBOARD
OFFICE 09 09
ASS.H/K 05
OFFICE B.O.H LIFT 05
08 SERVICE SERVICE (FIREMAN) 08
LIFT 011 LIFT 012
LIFT 15
LIFT LOBBY
07 LIFT PIT 13 LOBBY B.O.H LIFT 07
F.E. STAIR 02
SERVICE 06
LIFT LOBBY PRESSURIZATION MEP MEP MEP ELECT.
SHAFT SHAFT SHAFT SHAFT SHAFT HOUSEKEEPING
06 06 06 STORE 06
CORRIDOR
03
02 02
C E H R5A I J L N