DC–DC Switching Regulators
TR Series 100–300 Watts THE POWER PROFESSIONALS
TR Series Features
Common specifications and characteristics
• Non-isolated.
• Cost Effective. Operating Temperature Range: -10 to +55˚ C.
• Epoxy filled Aluminum case. Efficiency: 90%.
• Extremely rugged and well suited Switching Frequency: 30 KHz.
for marine and other demanding All units are CE Marked.
environments. Conformance to: EMC EN 55022, EN50081-1, EN50082-1,
• High tolerance for shock FCC Class B, UL 1950.
and vibration. Input Protection (fuse): TR100/12/24: 20 A; TR100/24/12: 7.5 A;
• Continuous current ratings. TR200/24/12: 5 A; TR300/24/12: 20 A.
Remote Power Switch: All models except TR100/12/24.
• Supports battery supply variations.
Output Protection:
• Remote low-power switch—can
24 V input units: constant current limit at 115% of full load.
also be wired for direct connection
TR100/12/24: 5 A output fuse.
(not available on TR100/12/24).
24- to 12-volt units: Overvoltage crowbar at 17 ±1 V.
• Fully protected. Mounting: All mounting holes 5 mm (.2") diameter.
Weight: TR100: .7 Kg / 1.5 lbs. TR200 and TR300: 1.5 Kg / 3.3 lbs.
860/355-4711 • FAX 860/354-8597
page 20
www.avellindberg.com • sales @avellindberg.com
DC–DC Switching Regulators
THE POWER PROFESSIONALS TR Series 100–300 Watts
TR1 0 0 TR200 and TR300
76 (3.0) 127 (5.0)
57 (2.3) 100 (4.0)
5 (.2)
Avel Lindberg, Inc. dia. typ.
Switching Regulator
140 TR100
(5.5)
127
INPUT FUSE
OUTPUT
(5.0) 184
(7.3)
INPUT
WHITE ON/OFF
100 152 Avel Lindberg, Inc.
Switching Regulator
(4.0)
ORANGE +
(6.0) TR200
BROWN–
BLACK–
RED +
•
5 (.2)
dia. typ.
INPUT FUSE
OUTPUT
INPUT
WHITE ON/OFF
Leads 250 (10)
ORANGE +
BROWN–
BLACK–
long typ.
RED +
•
39 (1.5) Leads 250 (10)
long typ.
39 (1.5)
140 (5.5)
Dimensions in mm (inches). • Proportions altered to illustrate detail.
Switching Regulator Specifications—TR Series
Input Output Output Output Output No-Load
Voltage, DC Voltage Current Voltage Regulation Ripple Input
AVEL P/N
Nominal Range (Nominal) Continuous Max. 0–10%(2) 0–100%(2) (mV) (mA)
12.0 10–18 24.0 ±.5 5A 12A(1) 0.4 0.2 <100 8 TR100/12/24
24.0 18–35 13.7 ±.2 8A 8A 0.4 0.1 <50 4 TR100/24/12
24.0 18–35 13.7 ±.2 16A 16A 0.4 0.1 <50 8 TR200/24/12
24.0 18–35 13.7 ±.2 25A 25A 0.4 0.1 <50 8 TR300/24/12
(1) 10 milliseconds.
(2) Percentage of load.
Switch connection: To use remote switch, connect white (remote input) to one side of switch and
+ (red) lead to other side of switch.
If switch is not required, white (remote input) must be connected to + (red).
Nominal input voltage must be applied to remote switch line to turn unit on.
860/355-4711 • FAX 860/354-8597
page 21
www.avellindberg.com • sales @avellindberg.com