Universal Converter Covers All The Bases-RS-232 To 4-Wire RS-422, 2-Wire or 4-Wire RS-485
Universal Converter Covers All The Bases-RS-232 To 4-Wire RS-422, 2-Wire or 4-Wire RS-485
Universal Converter Covers All The Bases-RS-232 To 4-Wire RS-422, 2-Wire or 4-Wire RS-485
Model 4WSD9R
Universal Converter
Covers All the Bases-
RS-232 to 4-wire RS-422,
2-wire or 4-wire RS-485
The 4WSD9R Universal Converter is a port-powered or externally powered two-channel RS-232 to RS-422/RS-485
converter. It converts TD and RD RS-232 lines to balanced RS-422 or RS-485 signals. RS-485 is an enhanced version
of the RS-422 standard, allowing multiple drivers and receivers on a two-wire system. The unit is powered from the RS-
232 data and handshake lines whether the lines are high or low. Or, if there is not enough power on the port, it can be
powered by an external +12VDC 100mA supply. The 4WSD9R has DB-9 female connectors on both the RS-232 side
and the RS-485 side. The RS-232 connector is configured as DCE (like a modem).
RS-232 Side:
Connector: DB-9 female (DCE)
Signals: Passes through pins 3 (TD) and 2 (RD)
Pins 7 (RTS) and 8 (CTS) are tied together
Pins 4 (DTR), 6 (DSR), and 1 (CD) are tied together
RS-422/RS-485 Side:
Connector: DB-9 female
Signals: RS-485 2-wire half-duplex, or RS-485 4-wire full-duplex,
or RS-422 4-wire full-duplex depending on switch configurations
Automatic control circuit enables driver only when transmitting
Receiver can be disabled when transmitting to prevent echo back to RS-232 device when in 2-wire mode
Data Rates: Up to 115.2 kbps
Distance: Externally powered transmits up to 4000 ft (1200 m) at 115.2 kbps (may be less with port powering)
Dimensions: 3.0 x 1.6 x 0.8 in (7.8 x 4.3 x 2.0 cm)
Table 1:
Power RS-232 Pinout
No external power is required if two RS-232 output handshake lines are available and the cable Pin # Signal
run is short. If the handshake lines are raised and no termination is used, the power efficiency is 1 DCD
greatly increased. Less than 3mA is required to operate the 4WSD9R plus the load current. For 2 RD
applications that do not have handshake lines or require a large load current, power may be
3 TD
externally supplied with a +12VDC power supply with a 2.5mm plug (tip positive).
4 DTR
RS-232 Operations 5 GND
6 DSR
The RS-232 port has a female DB9 connector with pins 2 (RD), 3 (TD), and 5 (Signal Ground)
supported. Pins 7 (RTS) and 8 (CTS) are tied together, and pins 6 (DSR), 1 (DCD), and 4 7 RTS
Integrate – Expand – Simplify
(DTR) are also tied together. Any incoming data lines in either the high or low state are used to 8 CTS
port power the 4WSD9R. The more handshake lines available, the more likely the unit can be port powered. Table 1
shows the RS-232 pinout.
Table 2:
RS-422/485 Operations RS-422/485 Pinout
Although the 4WSD9R can use handshake lines to power the converter, no handshaking is
required to control the RS-422/RS-485 driver. With switch 1 set to RS-422, the driver is Pin # Signal
always enabled. When switch 1 is in the RS-485 position, the RS-485 driver is automatically 2 RD(A)-
enabled during each spacing state on the RS-232 side. During the marking or idle state, the 3 TD(B)+
RS-485 driver is disabled and the data lines are held in the marking state by the 4.7K Ohm pull- 4 GND
up and pull-down resistors. The value of these resistors may need to be changed to a different 6 GND
value when termination is used in order to maintain the proper DC bias during the idle state. 7 RD(B)+
See B&B Electronics’ free RS-422/RS-485 Application Note for more information on termination 8 TD(A)-
and DC biasing of an RS-485 network.
International Headquarters:
707 Dayton Road P.O. Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com [email protected] [email protected]
3 4-wire
when termination is used in order to maintain the proper DC bias during the idle state. 4 4-wire
See B&B Electronics’ free RS-422/RS-485 Application Note for more information on
termination and DC biasing of an RS-485 network.
The receiver is enabled at all times, allowing devices to receive information even while they are responding
to a request. To set up for this mode on the 4WSD9R, place switch 1 in the RS-485 position, switch 2 in the
echo on position, and switches 3 and 4 in the 4-wire position. The wiring between the slave and the master
is identical to the RS-422 4-wire full-duplex diagram shown in Figure 3, and in many cases the master in a
master/slave RS-485 network is set up as an RS-422 device. When multiple slaves are on the same
network, the connection between the master and each slave must be the same as shown in Figure 2. This
will cause all slaves to have their transmitters connected and their receivers connected, and not allow
communications between the slaves themselves.
International Headquarters:
707 Dayton Road P.O. Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com [email protected] [email protected]
_________________________
i
If you are concerned about creating ground loops by connecting grounds of units together, please check into
B&B Electronics’ line of optically isolated RS-232 to RS-422/485 units such as the 485OT9L.
This product is Designed and Manufactured in the USA of domestic and imported components.
International Headquarters:
707 Dayton Road P.O. Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com [email protected] [email protected]
DECLARATION OF CONFORMITY
Manufacturer’s Name: B&B Electronics Manufacturing Company
Manufacturer’s Address: P.O. Box 1040
707 Dayton Road
Ottawa, IL 61350 USA
Model Number: 4WSD9R
Description: RS-422/485 Converter
Type: Light industrial ITE equipment
Application of Council Directive: 89/336/EEC
Standards: EN 55022
EN 61000-6-1
EN 61000 (-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11)
International Headquarters:
707 Dayton Road P.O. Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com [email protected] [email protected]