8 - Banding Tool (Operating Instruction)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

BAND-IT® Tie-Dex II®

Banding Tools
600-058
600-061
Operating Instructions

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
1
600-058 & 600-061
Operating Instructions

Band-It ® Standard, Micro and Nano Overview


1 Calibration Access Plug
2 Tensioning Lever:
Squeeze with short gentle strokes to 4
tighten band to the proper tension.
Lever will lock to 3 Handle with final 7
full stroke.
4 Cut-Off Lever: 6
Squeeze to lock band buckle and trim
excess band material.
5 Band Insertion and Release Lever:
Depress lever to insert or release band
from tool. 3
6 Serial Number 5 1
7 Tension Release Lever
NOTES:
1. Use only genuine Glenair/Band-It bands. Other 2
manufacturer’s bands may damage tool.
2. Use only .240" wide bands with 600-058 tool
and .120" wide bands with 600-061 tool.

Shield Termination Preparation Process


Step 1 
Prepare Cable Braid for termination process.

NOTE: banding must occur on an unfixtured


cable assembly. Attaching a band to a firmly
clamped cable will affect the applied forces and
will also interfere with the cut-off operation.
The cut-off operation causes a rotation of the
band termination in order to lock the band.

Step 2 
Push braid forward over banding platform.
Milk braid as required to remove slack and
insure a snug fit around the shield termina-
tion area.

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
2
600-058 & 600-061
Operating Instructions

Shield Termination Assembly Process


Step 3
Double-coil the band prior to use:

IMPORTANT: Due to connector/adapter circumference, it may be necessary to


double-coil the band in place around the cable or retention area.

A. Insert leading edge of band through the buckle slot twice. (Bands must be
double-coiled.)

B. Tighten the coil until the indicator mark ( ) is approximately .250 inch
(6.4mm) shy of the buckle slot (see illustration below). This will ensure sufficient
band tail length for insertion into tool.

Buckle

Tail Length
.250 in. Indicator Mark ( )
(6.4 mm)

Step 4
Depress the band insertion and release lever (5), and insert the band into the
front end opening of the tool, with the loop positioned outward as shown.

Squeeze the band insertion


and release lever

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
3
600-058 & 600-061
Operating Instructions

Shield Termination Assembly Process


Step 5
The band termination area on all backshells is wider than the band. Position
the band near the rear lip of the banding platform, allowing room for buckle.
For eliptical cable entries position the buckle off center of the peak of the circle.
Failure to follow these guidelines will result in poor performance.
Position the band near
the rear lip leaving
room for buckle.
Position Not Here
the buckle
off-center as
shown

Not Here

Step 6 
Contract the band with the tensioning lever (2) using short, even strokes, as
the band is firmly secured on termination area pull a full stroke to lock handle
handle against the tool body indicating the band is compressed to the proper
tension.

NOTE: Overly rapid tightening of the band may result in uneven compression. If
alignment of the band and shield is unsatisfactory, tension can be relaxed by pulling
up tension lever (2) and pushing the release lever (7) forward on top of the tool.
Make adjustments as necessary and finish tightening with tensioning lever (2) as
described above.Instructional videos are available on the Glenair website:
www.glenair.com/banding/
Tension
release lever

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
4
600-058 & 600-061
Operating Instructions

Shield Termination Assembly Process


Step 7 
Complete the clamping process by depressing the cut-off lever (4), Allowing
band and cable to rotate slightly.

Note: Always install bands on


an unfixtured connector/cable
assembly.

Step 8 
Pull up the release lever (5) to remove excess band for disposal.

Step 9 
Trim away excess braid Groove for
from the forward groove, shrink boot
particularly if a shrink
boot is to be applied to
the assembly.

Step 10
Visually inspect shield termi-
nation for problems.

NOTE: Band can be removed


by lifting buckle with a
screwdriver or diagonal cutters.

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
5
600-058 & 600-061
Operating Instructions

Tool Calibration
Band-It®

calibration interval can be determined by tool users. Glenair also provides calibration
services. A portable kit is available for on-site calibration. Factory calibration values
are 150 ± 5 lbs for standard band tool 601-100, and 80 ± 5 lbs for the micro band tool
601-101.

601-200 Calibration Kit For


All Banding Tools
The 601-200 Calibration Kit provides fast, easy, accurate calibration of
all banding tools.
Kit includes the (1) 601-200-3 Calibration Device, (2) Fifty 601-203 Micro Test
Bands, (3) Fifty 601-202 Standard Test Bands, (4) 601-217 Fifty Nano Test Bands
(5) Calibration Adjustment Key, (6) 601-218 Adjustable Mounting Bracket for
Meter (7) Data Logging Software, (8) Tool Adapter for 600-058 (9) 601-219 Tool
Adapter for 600-067 and 601-104 (10) 601-220 Tool Adapter for 600-061,
600-068, 601-105 (11) Tool Adapter for 601-109, 601-110, 601-100, 601-106 (12)
Tool Adapter for 601-101, 601-107, 601-122, 601-123 (13) 601-226 Tool Adapter
for 601-108, 601-118.

Range of the calibration device is 60 to 170 lbs, accuracy is calibrated to ±1 lb.


at factory.
Dimensions: 6.65 in. x 2.47 in. x 2.83 in. (168.9 x 62.7 x 71.9mm).
Weight: 2.10 lbs. (1.0Kg).
1

8 9 10 11 12 13
6

7
2 3 4

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
6
600-058 & 600-061
Operating Instructions

Tool Repair and Refurbishment


Glenair provides repair and refurbishment services for Band-It® tools. Typical ser-
vices include calibration along with replacements of cutter knife and cut-off blade.
Simply send the tool to Glenair:

ATTN: Customer Service


Glenair, Inc.
1211 Air Way
Glendale CA 91201

Pneumatic Tools for High Volume Production


Pneumatic Band-It® tools speed up band installation and reduce operator fatigue.

6.88 (174.8)
Band-It® Pneumatic
2.25 (57.2)
Banding Tools
3.14 (79.8)
The Tie-Dex II® Pneumatic
Banding Tools provide fast, easy
3.00
(76.2)
Control Box
band installation.
Weight of the tool is 2.52 lbs (1.14
Kg); the control box weighs 2.74 lbs
Pneumatic Tool NOTE: Hoses
typically can extend to (1.24 Kg).
approximately 10 feet
(3.65 meters).
600-067 for use with standard bands.
5.00
(127.0)
600-068 for use with micro bands.
4.85
(123.2)

600-074 Foot Pedal Control


for Pneumatic Banding Tools
frees both hands to help assure more
accurate, reliable and faster shield
terminations.

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
7
Visit the Glenair website for additional information on
backshell assembly tools, banding tools and accessories:
www.glenair.com

Training videos on Band-It® termination procedures are available on


the Glenair website:
http://www.glenair.com/banding/
Consult factory for additional recommendations for technical
information on overall shields with distributed individual shields on
common terminations.

BANDS & REPLACEMENT PARTS FOR 600-058 TOOL


Standard Length Band, Supplied Flat 600-052
Standard Length Band, Supplied Pre-Coiled 600-052-1
Extended Length Band, Supplied Flat 600-090
Extended Length Band, Supplied Pre-Coiled 600-090-1
Cut-Off Blade Kit (A40699) 600-056
Cutter Knife 600-062

BANDS & REPLACEMENT PARTS FOR 600-061 TOOL


Standard Length Band, Supplied Flat 600-057
Standard Length Band, Supplied Pre-Coiled 600-057-1
Extended Length Band, Supplied Flat 600-083
Extended Length Band, Supplied Pre-Coiled 600-083-1
Cut-Off Blade Kit 600-060
Cutter Knife 600-082

© 2014 Glenair, Inc. 990-99172 CAGE Code 06324 Printed in U.S.A.


GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497
818-247-6000 • FAX 818-500-9912 www.glenair.com
8

You might also like