0% found this document useful (0 votes)
77 views25 pages

Network Proximity Access Control Operation and Installation Manual

The document provides instructions for operating and setting up the ST-680 network proximity access control reader. It allows for adding and deleting cards, setting door opening modes, time zones, and alarm functions. The reader supports up to 9,000 card registrations and 48 time zones. It has indicator lights, number buttons, and function keys for operation. Proximity cards come in different models and thicknesses to provide access within reading ranges of 10-25 cm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views25 pages

Network Proximity Access Control Operation and Installation Manual

The document provides instructions for operating and setting up the ST-680 network proximity access control reader. It allows for adding and deleting cards, setting door opening modes, time zones, and alarm functions. The reader supports up to 9,000 card registrations and 48 time zones. It has indicator lights, number buttons, and function keys for operation. Proximity cards come in different models and thicknesses to provide access within reading ranges of 10-25 cm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 25

ST-680

NETWORK PROXIMITY ACCESS CONTROL OPERATION

AND INSTALLATION MANUAL

SOCA TECHNOLOGY CO.,LTD.


2000 JULY
CONTENTS
1. Features introductions 3
2. Reader Front panel & types of proximity card 4
3. Operation instructions. 5
Start reader 5
Mode inquiry 5
Anti-duress 5
Setup mode 5
4. Quick setting 6
5. Setup mode function selection instructions (00 ~ 28) 6
(01) Add new card (17) Auto record range
(02) Delete card (18) Main reader location
(04) Shunt time (19) Door shutting time
(05) Open door mode (20) Alarm mode
(07) Reset to release alarm (21) Anti-duress alarm mode
(08) Change system password (22) Door sensing mode
(09) Reset to release anti-duress alarm (23) Anti-theft sensing mode
(10) Reader ID number (24) Push button door open sensing mode
(11) Password error times (25) BEEP sound mode
(12) Anti-duress code (26) Print mode
(13) Total cards (27) Anti-pass mode
(14) Program version (28) Display card number mode
(15) Set time (00) Instant door open
(16) Set date
6. Installation instructions 19
Reader connector 19
Wiring connection for additional electric lock and push button door open switch 20
Wiring connection for additional magnetic door sensing 21
Wiring connection for anti-theft sensing (NO Type) 21
Wiring connection for additional alarm 21
Wiring connection for linking with computer 22
7. Hardware specifications 23
8. Attentions 23
9. Troubleshooting 23

2
ST-680 OPERATION INSTRUCTIONS

1. Features introductions
★ When connecting with computer, it can be used for data inquiry and function setting
simultaneously. (Door open/close, start alarm system, etc). It can also operate solely to
manage access control.
★ Function setting can be done by computer or reader itself. (Single registration or deletion,
door open time, etc).
★ The capacity data input/output can reach up to 6,000 by single reader operation. When
linking with computer, its data input/output capacity can be unlimited.
★ Main reader has 9,000 card registrations capability. Each card can be self-setting for
personal password and effective in/out time.
★ Main reader has 48 units of time zone. Each time zone unit also has 5 time ranges for
self-setting by user.
Example: It can be set from “G” hour “H” minute to “I” hour “J” minute on every
Mondays, Wednesdays, Saturdays in periodic of “A” year “B” month “C” day
to “D” year “E” month “F” day as effective in/out time range.
★ Directly link to series type printer for direct data printing.
★ Additional sub-reader for in/out control.
★ Equipped with hardware self-testing function
★ Internal batteries will provide power supply when power cut occurred to prevent any data
from being erased and system time can operate as normal.
★ Main reader access control’s range:
* Card number -It must be registered before use.
* Password -Personal password has to key in to open the door.
* Time zone -Setting the effective of year, month, day, time range, Monday ~
Sunday
* Special holidays -User could set any holidays as to prevent any unauthorized access.
* Error control -Alarm will activate when “N” times of consecutive error password
entering occurred.
* Anti-pass -The card could only be used for matching single entry and exit.
(Otherwise, it will be considered the card has been duplicated causing
access denial.)

★ Main reader’s sensing range:


* Anti-tamper - when the reader is tampered, alarm will be activated.
* Anti-theft - Alarm will be activated when sensing any abnormal operations.
* Illegal door open - Alarm will be activated when door is destroyed and opened by force.

3
* Anti-duress - It will operate when password and duress code are keyed in to send help
signal to the nearest police station. It must be done manually to disable
anti-duress function.
* Exceed door shut time - Alarm will be activated, when door is not closed exceeding initial
time setting control.
* Door open button sensing - Door will open immediately when the button is pushed.

2. Reader Front Panel & Types of Proximity Card


(a) Front Panel Indicator Lights
(1). POWER (red) : power indicator.
(2). OK (green) : door open indicator.
(3). DENY (yellow) : operation error or unregistered card indicator.
(4). STATUS (yellow) : system starts and setup mode indicator.

(b) 10 entry (buttons), two function keys: “#”&“*”.


# key : input data confirm key (Enter)
* key : clear or escape key (CLR/ESC)

(c) Types of proximity card

SC-10 thin card:


ISO standard card size, thickness 0.8 m/m. Card-printing machine can
be used to print user photo or picture directly. Read range, 25cm

SC-20 thick card:


ISO standard card size, thickness 1.78 m/m. Card-printing machine
can be used to print user photo or picture directly. It can also be used
12345678
as hang plate. Read range, 25 cm.

SC-30 key tag:


Key ring type designed, easy hand carrying, supersonic welding,
waterproof, shockproof. Dimensions: 51mm (L), 32mm(H), 7.8mm(W).
Read range, 10 cm.

4
3. Operation instructions
Start reader: It will begin self-testing function when power is switched on. Its operation
procedures are as follow:
LCD DISPLAY INSTRUCTIONS
SRAM TESTING Memory testing
RTC TESTING Real time clock testing
INITIAL FUNCTION Initial system setting
<<ST680>> 08:05 Model (ST680), present time (08:05), 10 registrations.
0010

Note: Card must not exceed the read range (refer to different models) to gain induction.
a). OK (green) light is on to indicate registered card to gain access.
b). DENY (yellow) light is on and consecutive beeping sound is on to indicate
unregistered card or used under unauthorized time zone. (Please refer to
troubleshooting if neither of above statuses occurred)

MD ADR YYYY/MM/DD
Mode inquiry: Press * # #, LCD will display:
2 001 1999 / 01 / 01
MD: open door mode (2 shows door open by proximity card sensing, 3 shows
door open by proximity card sensing with password.)
ADR: main reader number. YYYY/MM/DD: current date.
Re-press * to escape.

Anti-duress: When under duress, user may press * button before keying in password to
activate alarm.(Duress code presetting is *, it can be changed by user)
Example : anti-duress code is 1 , password is 1 2 3 4 , then to activate
anti-duress alarm, the user should key in 1 1 2 3 4 .

Setup Mode:
User must get into setting mode first before changing any
SYSTEM FUNCTIONS system functions. User must key in # system password
 SELECTION : _ _ # for system function selection. System password is being
set 5678 initially by manufacturer. (Example: User can
get into the set up mode by keying #5678#).

5
4. Quick setup:
SYSTEM FUNCTIONS
User will get into the setup mode as the right diagram
 SELECTION : _ _
shown for any setting to be made.
(A) Add new card , key in 0 1 then key in 0 0 0 0 0 0 0 1.
8-digit card number
(B) Delete card, key in 0 2 then key in 0 0 0 0 0 0 0 1.
8-digit card number
(C) Door open time, key in 0 4 then key in the seconds 0 0 3.
(D) Change reader number, key in 1 0 then key in the reader number 0 0 2.
(E) Door open mode, key in 0 5 then key in the mode code 2.
(F) Time setting, key in 1 5 then key in the time 1 3 0 0 1 5.
13:00:15
(G) Date setting, key in 1 6 then key in 2 0 0 0 0 1 0 1 6.
2000/01/01 (6)
Note: (1)Sunday (2)Monday (3)Tuesday (4)Wednesday (5)Thursday (6)Friday (7)Saturday
(H) Release alarm, key in 0 7 , confirmed then press #.
( I ) Release anti-duress alarm, key in 0 9 , confirmed then press #.

5. SETTING MODES & FUNCTIONS

Function (01) Add new card:


Either key in 8-digit card number or use proximity card to register, both can be accepted but
should be registered prior using.

Esc system function selection.


Key in #or *
status light on, display Queuing 8-digit card number input,
Go into system function setup.
function selection. Go into function 01. key in manually or by proximity.
Key in SYSTEM FUNCTIONS ADD ONE CARD
 SELECTION : _ _
Key in 01 ________
#system password#
Registration successful,
beep sound occurred.
ADD ONE CARD
00000001
Registration repeated, beep
sound on continuously.
ADD ONE CARD
ACCESS DENIAL

back to system function selection.


Key in the #or *

6
Function (02) Delete card:
Deletion of user’s card (such as loss of card or to prevent specific user to gain access) can
be achieved by keying 8-digit card number indicated on the proximity card.

Esc system function selection.


Key in #or *
status light on, display queuing 8-digit card number input,
Go into system function setup. function selection. Go into function 02. key in manually or by proximity.
Key in SYSTEM FUNCTIONS DELETE ONE CARD
 SELECTION : _ _
Key in 02 ________
#system password#
Deletion successful, a
beep sound occurred.
DELETE ONE CARD
00000001

NO such card, beep


sound on continuously.
DELETE ONE CARD
ACCESS DENIAL

back to system function selection.


Key in the #or *

Function (04) Shunt time:


Setting of relay’s ON/OFF time in the proximity reader can be set from 01-255 seconds.
(pre-setting time is 003)

Esc system function selection.


Key in #or *
status light on, display
Go into system function setup. function selection.
Go into function 04. Queuing for shunt time input.
Key in SYSTEM FUNCTIONS SET SHUNT TIME
 SELECTION : _ _ Key in 04
#system password# ( 1 - 255 ) : 003 _ _ _
Wrong input, beep
sound on continuously.
SET SHUNT TIME
( 1 - 255 ) : 003 000

Setting successfully,
beep sound occurred.
SET SHUNT TIME
( 1 - 255 ) : 003 005

back to system function selection.


Key in the #or *

7
Function (05) Door open mode:
Reader has 2 types of identification modes. (pre-setting figure is 002)
Mode (2). Card proximity door opening: The door will be opened, when the card is sensed.
Mode (3). Door open by proximity card and password: The door will be opened by keying
additional 4-digit password after sensing the registered card.

Esc system function selection.


Key in #or *
status light on, display Queuing the identification
Go into system function setup.
function selection. Go into function 05. mode input.
Key in SYSTEM FUNCTIONS IDENTIFICATION
 SELECTION : _ _
Key in 05 MODE ( 2 - 3 ) : 2
#system password#
Wrong input, beep
sound on continuously.
IDENTIFICATION
MODE ( 2 - 3 ) : 1

Setting successfully,
beep sound occurred.
IDENTIFICATION
MODE ( 2 - 3 ) : 3

back to system function selection.


Key in the #or *

Function (07) Reset to release alarm:


User sets to release the alarm.

Esc system function selection.


Key in #or *
status light on, display Queuing the alarm input
Go into system function setup.
function selection. Go into function 07. is reset or not.
Key in SYSTEM FUNCTIONS ALARM RELEASED
 SELECTION : _ _
Key in 07 YES => “ # “
#system password#
Setting successfully,
alarm is released.
Key in the #

back to system function selection.


Press other keys

8
Function (08) Change system password:
The reader’s password is being set at 5678 initially by manufacturer. In order to enter
into system setting mode for the first time, user must key in the initial system password –5
678. User may change the system password after entering into system setting mode.

Esc system function selection.


Key in #or *
status light on, display Queuing new system
Go into system function setup.function selection. password input.
Go into function 08.
Key in SYSTEM FUNCTIONS INPUT NEW SYSTEM
#system password#  SELECTION : _ _ Key in 08 PASSWORD : _ _ _ _

Input successfully (4 digits).


Beep sound on consecutively, INPUT NEW SYSTEM
error input. (first and last 4- Re-enter new system PASSWORD : 1234
digit password different) password for confirmation.
CONFIRM SYSTEM
CONFIRM SYSTEM Error input.
PASSWORD : 0000
PASSWORD : _ _ _ _ INPUT NEW SYSTEM
PASSWORD : 12# _
Input successfully. (same password)
CONFIRM SYSTEM
PASSWORD : 1234 Esc system function selection.
Key in the #or *

Function (09) Reset to release anti-duress alarm:


User sets to release the anti-duress alarm.

Esc system function selection.


Key in #or *
status light on, display Queuing for anti duress
Go into system function setup.function selection. Go into function 09. alarm released or not.
Key in SYSTEM FUNCTIONS DURESS RELEASED
 SELECTION : _ _
Key in 09 YES => “ # “
#system password#
Setting successfully, anti-
duress alarm is released.
Key in the #

back to system function selection.


Press other keys

9
Function (10) Reader ID number:
Each reader has a reader ID number for computer identification and the number should not
be repeated. (pre-setting figure is 001)

Esc system function selection.


Key in #or *
status light on, display Queuing for reader ID
Go into system function setup.
function selection. Go into function 10. number input.
Key in SYSTEM FUNCTIONS READER ID NUMBER
#system password#  SELECTION : _ _ Key in 10 ( 1 - 255 ) : 001 _ _ _
Wrong input, beep
sound on continuously.
READER ID NUMBER
( 1 - 255 ) : 001 256
Setting successfully,
beep sound occurred.
READER ID NUMBER
( 1 - 255 ) : 001 002

back to system function selection.


Key in the #or *

Function (11) Password error times:


Alarm will be activated when “N” times of consecutive error password entering occurred.
(pre-setting figure is 003)

Esc system function selection.


Key in #or *
status light on, display Queuing for password
Go into system function setup.
function selection. Go into function 11. error times input.
Key in SYSTEM FUNCTIONS ERROR TIMES
 SELECTION : _ _
Key in 11 ( 1 - 255 ) : 003 _ _ _
#system password#
Wrong input, beep
sound on continuously.
ERROR TIMES
( 1 - 255 ) : 003 256

Setting successfully,
beep sound occurred.
ERROR TIMES
( 1 - 255 ) : 003 002

back to system function selection.


Key in the #or *

10
Function (12) Anti-duress code :
Set up of anti-duress code (*,0〜9). (pre-setting code is *)

Esc system function selection.


Key in #or *
status light on, display Queuing for anti-duress
Go into system function setup.
function selection. Go into function 12. code input.
Key in SYSTEM FUNCTIONS SET DURESS CODE
Key in 12 0-9,* : * _
#system password#  SELECTION : _ _

Setting successfully,
beep sound occurred.
SET DURESS CODE
0-9,* : * 9

back to system function selection.


Key in the #or *

Function (13) Total cards:


Display total number of current registered cards.

Esc system function selection.


Key in #or *
status light on, display Display total number of
Go into system function setup.
function selection. Go into function 13. current registered cards.
Key in SYSTEM FUNCTIONS USER CARD COUNT
#system password#  SELECTION : _ _ Key in 13 0200

back to system function selection.


Press any key

Function (14) Program version:


Display program version.

Esc system function selection.


Key in #or *
status light on, display
Go into system function setup.
function selection. Display program version.
Go into function 14.
Key in SYSTEM FUNCTIONS VERSION : V1﹒08
 SELECTION : _ _
Key in 14
#system password#

back to system function selection.


Press any key

11
Function (15) Set time:
Example: 18 hour 00 minute 00 second => 18:00:00 (pre-setting figure is 00:00:00)

Esc system function selection.


Key in #or *
status light on, display Queuing for system
Go into system function setup.
function selection. Go into function 15. time input.
Key in SYSTEM FUNCTIONS SET TIME
#system password#  SELECTION : _ _ Key in 15 17 : 50 : 50
Wrong input, beep
sound on continuously.
SET TIME
17 : 50 : 99
Setting successfully,
beep sound occurred.
SET TIME
18 : 00 : 00

back to system function selection.


Key in the #or *

Function (16) Set date:


Example 2000/04/30 Sunday => 2000/04/30 (1) (pre-setting is 2000/01/01 (5))

Esc system function selection.


Key in #or *
status light on, display Queuing for system
Go into system function setup.
function selection. date input.
Go into function 16.
Key in SYSTEM FUNCTIONS SET DATE
 SELECTION : _ _
Key in 16 1999 / 01 / 01 ( 5 )
#system password#
Wrong input, beep
sound on continuously.
SET DATE
1999 / 03 / 29 (0 )

Setting successfully,
beep sound occurred.
SET DATE
1999 / 03 / 29 ( 1 )

back to system function selection.


Key in the #or *

12
Function (17) Auto Record range:
This is to set under what kind of status to save by stand alone operation. (pre-setting figure
is 003). There are 4 kinds of status to choose:
A. Detect point / output action. (+1) B. Computer special command. (+2)
C. Single reader operation status. (+4) D. User error status. (+8)
Example:
If A and B statuses are chosen, the setting figure for auto record range is 3 (1+2)
If A, B, and D statuses are chosen, the setting figure for auto record range is 11 (1+2+8)
Esc system function selection.
Key in #or *
status light on, display Queuing for auto
Go into system function setup.function selection. record range input.
Go into function 17.
Key in SYSTEM FUNCTIONS AUTO REC RANGE
#system password#  SELECTION : _ _ Key in 17 ( 1 - 255 ) : 012 _ _ _
Wrong input, beep
sound on continuously.
AUTO REC RANGE
( 1 - 255 ) : 012 256
Setting successfully,
beep sound occurred.
AUTO REC RANGE
( 1 - 255 ) : 012 011

back to system function selection.


Key in the #or *

Function (18) Main reader location:


To show the location of the reader: (0) Indoor, (1) outdoor. (pre-setting location is 001)

Esc system function selection.


Key in #or *
status light on, display Queuing for main reader
Go into system function setup.function selection. Go into function 18. location input.
Key in SYSTEM FUNCTIONS READER=>0 / INDOOR
#system password#  SELECTION : _ _ Key in 18 1 /OUTDOOR : 1
Wrong input, beep
sound on continuously.
READER=>0 / INDOOR
1 /OUTDOOR : 2

Setting successfully,
beep sound occurred.
READER=>0 / INDOOR
1 /OUTDOOR : 0

back to system function selection.


Key in the #or *

13
Function (19) Door shutting time:
Time setting for sensing door-shutting time as to activate the alarm when exceeding the set
value. (pre-setting value is 030)

Esc system function selection.


Key in #or *
status light on, display Queuing for door
Go into system function setup.
function selection. Go into function 19. shutting time input.
Key in SYSTEM FUNCTIONS DOOR SENSOR SEC
Key in 19 ( 1 - 255 ) : 030 _ _ _
#system password#  SELECTION : _ _

Wrong input, beep


sound on continuously.
DOOR SENSOR SEC
( 1 - 255 ) : 030 256
Setting successfully,
beep sound occurred.
DOOR SENSOR SEC
( 1 - 255 ) : 030 015

back to system function selection.


Key in the #or *

Function (20) Alarm mode:


(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000) Once set at “ OFF “ , alarm
will not function.

Esc system function selection.


Key in #or *
status light on, display Queuing for alarm
Go into system function setup.
function selection. Go into function 20. mode input.
ALARM MODE
Key in SYSTEM FUNCTIONS Key in 20
 SELECTION : _ _
( 0 / ON , 1 / OFF ) : 1
#system password#
Wrong input, beep
sound on continuously.
ALARM MODE
( 0 / ON , 1 / OFF ) : 2
Setting successfully,
beep sound occurred.
ALARM MODE
( 0 / ON , 1 / OFF ) : 0

back to system function selection.


Key in the #or *

14
Function (21) Anti-duress alarm mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “ OFF “,
anti-duress alarm will not function.

Esc system function selection.


Key in #or *
status light on, display Queuing for anti-
Go into system function setup. function selection. Go into function 21. duress mode input.
Key in SYSTEM FUNCTIONS ANTI-DURESS MODE
Key in 21 ( 0 / ON , 1 / OFF ) : 1
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
ANTI-DURESS MODE
( 0 / ON , 1 / OFF ) : 2
Setting successfully,
beep sound occurred.
ANTI-DURESS MODE
( 0 / ON , 1 / OFF ) : 0

back to system function selection.


Key in the #or *

Function (22): Door sensing mode:


(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function at any abnormal door opening.

Esc system function selection.


Key in #or *
status light on, display Queuing for door
Go into system function setup. function selection. Go into function 22. sensing mode input.
DOOR SENSOR MODE
Key in SYSTEM FUNCTIONS Key in 22 ( 0 / ON , 1 / OFF ) : 0
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
DOOR SENSOR MODE
( 0 / ON , 1 / OFF ) : 2

Setting successfully,
beep sound occurred.
DOOR SENSOR MODE
( 0 / ON , 1 / OFF ) : 1

back to system function selection.


Key in the #or *

15
Function (23) Anti-theft sensing mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function at any cases of broken in.

Esc system function selection.


Key in #or *
status light on, display Queuing for anti-
Go into system function setup. function selection. Go into function 23. theft mode input.
ANIT-THEFT MODE
Key in SYSTEM FUNCTIONS Key in 23 ( 0 / ON , 1 / OFF ) : 0
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
ANTI-THEFT MODE
( 0 / ON , 1 / OFF ) : 2
Setting successfully,
beep sound occurred.
ANTI-THEFT MODE
( 0 / ON , 1 / OFF ) : 1

back to system function selection.


Key in the #or *

Function (24) Push button door opening sensing mode:


(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function if the push button is pressed.

Esc system function selection.


Key in #or *
status light on, display Queuing for push button
Go into system function setup. function selection. Go into function 24. switch mode input.
PUSH BUTTON MODE
Key in SYSTEM FUNCTIONS Key in 24 ( 0 / ON , 1 / OFF ) : 0
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
PUSH BUTTON MODE
( 0 / ON , 1 / OFF ) : 2

Setting successfully,
beep sound occurred.
PUSH BUTTON MODE
( 0 / ON , 1 / OFF ) : 1

back to system function selection.


Key in the #or *

16
Function (25) BEEP sound mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “ OFF “, the
BEEP sound will not function.

Esc system function selection.


Key in #or *
status light on, display Queuing for BEEP
Go into system function setup. function selection. Go into function 25. sound mode input.
BEEP MODE
Key in SYSTEM FUNCTIONS Key in 25 ( 0 / ON , 1 / OFF ) : 0
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
BEEP MODE
( 0 / ON , 1 / OFF ) : 2

Setting successfully,
beep sound occurred.
BEEP MODE
( 0 / ON , 1 / OFF ) : 1

back to system function selection.


Key in the #or *

Function (26) Print mode:


(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 001) Once set at “ON”, stored data
can be printed out immediately.

Esc system function selection.


Key in #or *
status light on, display Queuing for
Go into system function setup. Go into function 26. print mode input.
function selection.
PRINT MODE
Key in SYSTEM FUNCTIONS Key in 26 ( 0 / ON , 1 / OFF ) : 1
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
PRINT MODE
0 / ON , 1 / OFF ) : 2

Setting successfully,
beep sound occurred.
PRINT MODE
( 0 / ON , 1 / OFF ) : 0

back to system function selection.


Key in the #or *

17
Function (27) Anti-pass mode:
(0) shows “ ON”, (1) shows “OFF”. (pre-setting figure is 001) Once set at “ON”, the card
could only be used for matching single entry and exit. This is to prevent double entry by
using the same card if card has been duplicated.

Esc system function selection.


Key in or
status light on, display Queuing for anti-
Go into system function setup. function selection. Go into function 27. pass mode input.
ANTI - PASS MODE
Key in SYSTEM FUNCTIONS Key in 27 ( 0 / ON , 1 / OFF ) : 1
system password SELECTION : _ _
Wrong input, beep
sound on continuously.
ANTI - PASS MODE
( 0 / ON , 1 / OFF ) : 2

Setting successfully,
beep sound occurred.
ANTI - PASS MODE
( 0 / ON , 1 / OFF ) : 0

back to system function selection.


Key in the or

Function (28) Display card number mode:


(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, LCD will
not display the card number.

Esc system function selection.


Key in #or *
status light on, display Queuing for display card
Go into system function setup. function selection. Go into function 28. number mode input.
DISPLAY USER ID
Key in SYSTEM FUNCTIONS Key in 28 ( 0 / ON , 1 / OFF ) : 0
#system password#  SELECTION : _ _
Wrong input, beep
sound on continuously.
DISPLAY USER ID
( 0 / ON , 1 / OFF ) : 2

Setting successfully,
beep sound occurred.
DISPLAY USER ID
( 0 / ON , 1 / OFF ) : 1

back to system function selection.


Key in the #or *

18
Function (00) Instant door open:
Authorized personnel could get into the setup mode to open the door when any emergency
cases happened.

Esc system function selection


Key in #or *
status light on, display Queuing for door
Go into system function setup.
function selection. Go into function 00 open input.
Key in SYSTEM FUNCTIONS OPEN DOOR
#system password#  SELECTION : _ _ Key in 00 YES => “ # “
Setting successfully,
beep sound occurred.
Key in the #

back to system function selection.


Press other key

6. Reader installation instructions


(1)Reader connector

ST680 Wiring diagram

Yellow GND
Purple Anti-duress output terminal (low active)
Blue Alarm output point terminal (low active)
6 PIN CONNECTOR Green Door sensing terminal 2
Brown Door sensing terminal 1
Red Anti theft sensing terminal (low active)

Purple Push button door open joint terminal


Blue Door open relay (Common) terminal
Green Door open relay (Normal Close) terminal
8 PIN CONNECTOR Yellow Door open relay (Normal Open) terminal
Orange Signal (data) receiver
Brown Signal (data) transmitter
Black Input power, negative GND
Red Input power,positive 12V

Note: (1) Door open relay electrical rating is 2A/24 VDC, 1A/120VAC
(2) Push button door open / door sensing / anti-theft sensing all are connection
terminal. Any other power supplying is not allowed.
(3) In order to avoid any disturbance of read range, user is advised to use two
separate adaptors.

19
(2) Wiring connection for additional electric lock and push button door
open switch.
As of different types of electric lock, the wiring methods are also different . Overall, there
are two types of wiring instructions as below:
(a) Fail secure :

8 PIN Connector
R BK BR O Y G BL P

Push button switch

Diode’s white color terminal

A K
AP-10
AP-10
DC12V A EL
Nude type DC12V
electrical lock

(b) Fail safe :

8 PIN Connector
R BK BR O Y G BL P

Push button switch

Diode’s white color terminal

A K
AP-10
DC12V
AP-10
DC12V
Electro-Magnetic lock

Note: User must ensure the polarity (Diode) of the wiring connection for additional
electric lock is arranged correctly so that it is functional.

20
(3)Wiring connection for additional magnetic door sensing.

(a) N.O. type magnetic spring : (b) N.C. type magnetic spring :

6 PIN Connector N.O. type 6 PIN Connector N.C. type


R BR G BL P Y magnetic spring R BR G BL P Y magnetic spring

(4) Wiring connection for anti-theft sensing. ( N.O. type )

6 PIN Connector N.O. type


magnetic spring
R BR G BL P Y

(5) Wiring connection for additional alarm.


(a) Alarm :

8 PIN Connector 6 PIN Connector


R BK BR O Y G BL P R BR G BL P Y

A N C COM Alarm power


supply DC12V
N O
K
Diode’s white Eternal Relay
color terminal Connection DC12V

Note: User must ensure the polarity (Diode) of the wiring connection for additional alarm
is arranged correctly so that it is functional. User must also ensure that Setting
Mode (20) Alarm Mode is set ON.

21
(b) Anti-duress alarm :

8 PIN Connector 6 PIN Connector


R BK BR O Y G BL P R BR G BL P Y

A N C COM Alarm power


supply DC12V
N O
K

Diode’s white
Eternal Relay
color terminal
Connection DC12V

Note: User must ensure the polarity (Diode) of the wiring connection for additional
anti-duress alarm is arranged correctly so that it is functional. User must also
ensure that Setting Mode (21) Anti-Duress Alarm Mode is set ON.

(6) Wiring connection for linking with computer

2 st set N st set
1 st set
8 PIN Connector 8 PIN Connector
8 PIN Connector
R BK BR O Y G BL P R BK BR O Y G BL P
R BK BR O Y G BL P

RS-485 interface
transit connector
DATA+ RS-232
DATA-
communication line
PC
AP-20
AP-10
DC12V +VS
GND

22
7.HARDWARE SPECIFICATIONS
Power supply : DC 12V / 1A, Adapter.
Working environment : Temperature 0℃– 60℃, Humidity: 15% - 85%.
LCD : 16*2 STN LCD display with 4 LED’s indicators.
Buttons : 12 stainless steel buttons.
Real Time Clock : Internal equipped with a Real Time Clock (RTC) IC.
RAM : 128 KB memory.
Power backup system : Equipped with standby battery for saving if power is cut.
Communication system : Equipped internally with RS-485 interface. It can be
expanded to 255 terminals linking with computer operation simultaneously.
Output control system :
(A) Alarm output terminal can be connected with additional external alarm unit for
sounding.
(B) Open door output terminal can be matching used with electric lock for access
control.
(C) Anti-duress output terminal can be connected with hidden alarm to send help signal
to the nearest police station.
Input sensing system :
(A) Push button door open sensing point. Door will open instantly when button is
pressed.
(B) Door status terminal can be connected with external magnetic spring for sensing if
the door is closed or not.
(C) Anti-theft sensing terminal can be connected with external magnetic spring for
sensing if any appliances are closed or not.
(D) Anti-tamper sensing terminal uses to sense if the reader is being tampered by
force.

8. ATTENTIONS
1. Confirm the power supply voltage and polarity before installation to prevent any wrong
connection that causes damage to the reader.
2. Use separate power supply to the electric lock and the proximity reader.
3. Do not install the reader nearby any metal equipments or detector area to prevent
interference of read distance.
4. Do not try to fix or modify the reader without authorized electrician. The reader is
guaranteed for one year.

9. TROUBLESHOOTING
1. Reader has no reaction or door does not open with proximity card.
Solution: (1) Please check if the POWER light (red) is on. If not, please check the power supply
to turn the reader on.
(2) Please check if the proximity card is defected. User may use another proximity card
to test.
(3) Please check if personal password is entered incorrectly or the user is still in the
setup mode.
(4) Continuous proximity. Please remove the card form the reader and try again.
(5) Check if the DENY light (yellow) is on and continuous beep sound occur. This
indicates the user’s proximity card is not registered yet.
(6) Please check if OK light (green) is on and door-opening sound can be heard at the

23
same time. If door is still not opened, please ensure that if the wiring or power
supply of electric lock is installed properly or broken.

2. System password is entered but user cannot enter into various function selection of the
setting mode.
Solution: (1) System password is entered incorrectly. Please check if the following step has
been entered correctly. # X X X X #, (X X X X represent system password), or
press * button first and then enter the correct system password #5678#.
(2) Bad wiring arrangement may affect key enter data. Please confirm that the power
supply wire and the control wire have been arranged to the space at the back of
the LCD (this is the wiring arrangement area of this unit). This is to prevent the
wires pressing on the PC board causing bad contact, short circuit and interference.

3. How to use anti-duress setting?


Solution: (1) Please change the door open mode to mode 3. Therefore, door will be opened only
by keying additional 4-digit password after sensing the registered proximity card.
(2) When the door open mode is set, press anti-duress code (user can pre-set the
anti-duress code) before entering 4-digit password, thus the anti-duress alarm will
be activated.

24
APPENDIX A

Installation Steps:
Step 1, 2 Secure power supply wire and control wire through the base panel.
Step 3 Fit the reader on the base panel (power supply wire and control wire must first be
inserted and the wires must be arranged correctly)
Step 4 Use enclosed key wrench and screws to mount the reader up.