Network Proximity Access Control Operation and Installation Manual
Network Proximity Access Control Operation and Installation Manual
2
ST-680 OPERATION INSTRUCTIONS
1. Features introductions
★ When connecting with computer, it can be used for data inquiry and function setting
simultaneously. (Door open/close, start alarm system, etc). It can also operate solely to
manage access control.
★ Function setting can be done by computer or reader itself. (Single registration or deletion,
door open time, etc).
★ The capacity data input/output can reach up to 6,000 by single reader operation. When
linking with computer, its data input/output capacity can be unlimited.
★ Main reader has 9,000 card registrations capability. Each card can be self-setting for
personal password and effective in/out time.
★ Main reader has 48 units of time zone. Each time zone unit also has 5 time ranges for
self-setting by user.
Example: It can be set from “G” hour “H” minute to “I” hour “J” minute on every
Mondays, Wednesdays, Saturdays in periodic of “A” year “B” month “C” day
to “D” year “E” month “F” day as effective in/out time range.
★ Directly link to series type printer for direct data printing.
★ Additional sub-reader for in/out control.
★ Equipped with hardware self-testing function
★ Internal batteries will provide power supply when power cut occurred to prevent any data
from being erased and system time can operate as normal.
★ Main reader access control’s range:
* Card number -It must be registered before use.
* Password -Personal password has to key in to open the door.
* Time zone -Setting the effective of year, month, day, time range, Monday ~
Sunday
* Special holidays -User could set any holidays as to prevent any unauthorized access.
* Error control -Alarm will activate when “N” times of consecutive error password
entering occurred.
* Anti-pass -The card could only be used for matching single entry and exit.
(Otherwise, it will be considered the card has been duplicated causing
access denial.)
3
* Anti-duress - It will operate when password and duress code are keyed in to send help
signal to the nearest police station. It must be done manually to disable
anti-duress function.
* Exceed door shut time - Alarm will be activated, when door is not closed exceeding initial
time setting control.
* Door open button sensing - Door will open immediately when the button is pushed.
4
3. Operation instructions
Start reader: It will begin self-testing function when power is switched on. Its operation
procedures are as follow:
LCD DISPLAY INSTRUCTIONS
SRAM TESTING Memory testing
RTC TESTING Real time clock testing
INITIAL FUNCTION Initial system setting
<<ST680>> 08:05 Model (ST680), present time (08:05), 10 registrations.
0010
Note: Card must not exceed the read range (refer to different models) to gain induction.
a). OK (green) light is on to indicate registered card to gain access.
b). DENY (yellow) light is on and consecutive beeping sound is on to indicate
unregistered card or used under unauthorized time zone. (Please refer to
troubleshooting if neither of above statuses occurred)
MD ADR YYYY/MM/DD
Mode inquiry: Press * # #, LCD will display:
2 001 1999 / 01 / 01
MD: open door mode (2 shows door open by proximity card sensing, 3 shows
door open by proximity card sensing with password.)
ADR: main reader number. YYYY/MM/DD: current date.
Re-press * to escape.
Anti-duress: When under duress, user may press * button before keying in password to
activate alarm.(Duress code presetting is *, it can be changed by user)
Example : anti-duress code is 1 , password is 1 2 3 4 , then to activate
anti-duress alarm, the user should key in 1 1 2 3 4 .
Setup Mode:
User must get into setting mode first before changing any
SYSTEM FUNCTIONS system functions. User must key in # system password
SELECTION : _ _ # for system function selection. System password is being
set 5678 initially by manufacturer. (Example: User can
get into the set up mode by keying #5678#).
5
4. Quick setup:
SYSTEM FUNCTIONS
User will get into the setup mode as the right diagram
SELECTION : _ _
shown for any setting to be made.
(A) Add new card , key in 0 1 then key in 0 0 0 0 0 0 0 1.
8-digit card number
(B) Delete card, key in 0 2 then key in 0 0 0 0 0 0 0 1.
8-digit card number
(C) Door open time, key in 0 4 then key in the seconds 0 0 3.
(D) Change reader number, key in 1 0 then key in the reader number 0 0 2.
(E) Door open mode, key in 0 5 then key in the mode code 2.
(F) Time setting, key in 1 5 then key in the time 1 3 0 0 1 5.
13:00:15
(G) Date setting, key in 1 6 then key in 2 0 0 0 0 1 0 1 6.
2000/01/01 (6)
Note: (1)Sunday (2)Monday (3)Tuesday (4)Wednesday (5)Thursday (6)Friday (7)Saturday
(H) Release alarm, key in 0 7 , confirmed then press #.
( I ) Release anti-duress alarm, key in 0 9 , confirmed then press #.
6
Function (02) Delete card:
Deletion of user’s card (such as loss of card or to prevent specific user to gain access) can
be achieved by keying 8-digit card number indicated on the proximity card.
Setting successfully,
beep sound occurred.
SET SHUNT TIME
( 1 - 255 ) : 003 005
7
Function (05) Door open mode:
Reader has 2 types of identification modes. (pre-setting figure is 002)
Mode (2). Card proximity door opening: The door will be opened, when the card is sensed.
Mode (3). Door open by proximity card and password: The door will be opened by keying
additional 4-digit password after sensing the registered card.
Setting successfully,
beep sound occurred.
IDENTIFICATION
MODE ( 2 - 3 ) : 3
8
Function (08) Change system password:
The reader’s password is being set at 5678 initially by manufacturer. In order to enter
into system setting mode for the first time, user must key in the initial system password –5
678. User may change the system password after entering into system setting mode.
9
Function (10) Reader ID number:
Each reader has a reader ID number for computer identification and the number should not
be repeated. (pre-setting figure is 001)
Setting successfully,
beep sound occurred.
ERROR TIMES
( 1 - 255 ) : 003 002
10
Function (12) Anti-duress code :
Set up of anti-duress code (*,0〜9). (pre-setting code is *)
Setting successfully,
beep sound occurred.
SET DURESS CODE
0-9,* : * 9
11
Function (15) Set time:
Example: 18 hour 00 minute 00 second => 18:00:00 (pre-setting figure is 00:00:00)
Setting successfully,
beep sound occurred.
SET DATE
1999 / 03 / 29 ( 1 )
12
Function (17) Auto Record range:
This is to set under what kind of status to save by stand alone operation. (pre-setting figure
is 003). There are 4 kinds of status to choose:
A. Detect point / output action. (+1) B. Computer special command. (+2)
C. Single reader operation status. (+4) D. User error status. (+8)
Example:
If A and B statuses are chosen, the setting figure for auto record range is 3 (1+2)
If A, B, and D statuses are chosen, the setting figure for auto record range is 11 (1+2+8)
Esc system function selection.
Key in #or *
status light on, display Queuing for auto
Go into system function setup.function selection. record range input.
Go into function 17.
Key in SYSTEM FUNCTIONS AUTO REC RANGE
#system password# SELECTION : _ _ Key in 17 ( 1 - 255 ) : 012 _ _ _
Wrong input, beep
sound on continuously.
AUTO REC RANGE
( 1 - 255 ) : 012 256
Setting successfully,
beep sound occurred.
AUTO REC RANGE
( 1 - 255 ) : 012 011
Setting successfully,
beep sound occurred.
READER=>0 / INDOOR
1 /OUTDOOR : 0
13
Function (19) Door shutting time:
Time setting for sensing door-shutting time as to activate the alarm when exceeding the set
value. (pre-setting value is 030)
14
Function (21) Anti-duress alarm mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “ OFF “,
anti-duress alarm will not function.
Setting successfully,
beep sound occurred.
DOOR SENSOR MODE
( 0 / ON , 1 / OFF ) : 1
15
Function (23) Anti-theft sensing mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function at any cases of broken in.
Setting successfully,
beep sound occurred.
PUSH BUTTON MODE
( 0 / ON , 1 / OFF ) : 1
16
Function (25) BEEP sound mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “ OFF “, the
BEEP sound will not function.
Setting successfully,
beep sound occurred.
BEEP MODE
( 0 / ON , 1 / OFF ) : 1
Setting successfully,
beep sound occurred.
PRINT MODE
( 0 / ON , 1 / OFF ) : 0
17
Function (27) Anti-pass mode:
(0) shows “ ON”, (1) shows “OFF”. (pre-setting figure is 001) Once set at “ON”, the card
could only be used for matching single entry and exit. This is to prevent double entry by
using the same card if card has been duplicated.
Setting successfully,
beep sound occurred.
ANTI - PASS MODE
( 0 / ON , 1 / OFF ) : 0
Setting successfully,
beep sound occurred.
DISPLAY USER ID
( 0 / ON , 1 / OFF ) : 1
18
Function (00) Instant door open:
Authorized personnel could get into the setup mode to open the door when any emergency
cases happened.
Yellow GND
Purple Anti-duress output terminal (low active)
Blue Alarm output point terminal (low active)
6 PIN CONNECTOR Green Door sensing terminal 2
Brown Door sensing terminal 1
Red Anti theft sensing terminal (low active)
Note: (1) Door open relay electrical rating is 2A/24 VDC, 1A/120VAC
(2) Push button door open / door sensing / anti-theft sensing all are connection
terminal. Any other power supplying is not allowed.
(3) In order to avoid any disturbance of read range, user is advised to use two
separate adaptors.
19
(2) Wiring connection for additional electric lock and push button door
open switch.
As of different types of electric lock, the wiring methods are also different . Overall, there
are two types of wiring instructions as below:
(a) Fail secure :
8 PIN Connector
R BK BR O Y G BL P
A K
AP-10
AP-10
DC12V A EL
Nude type DC12V
electrical lock
8 PIN Connector
R BK BR O Y G BL P
A K
AP-10
DC12V
AP-10
DC12V
Electro-Magnetic lock
Note: User must ensure the polarity (Diode) of the wiring connection for additional
electric lock is arranged correctly so that it is functional.
20
(3)Wiring connection for additional magnetic door sensing.
(a) N.O. type magnetic spring : (b) N.C. type magnetic spring :
Note: User must ensure the polarity (Diode) of the wiring connection for additional alarm
is arranged correctly so that it is functional. User must also ensure that Setting
Mode (20) Alarm Mode is set ON.
21
(b) Anti-duress alarm :
Diode’s white
Eternal Relay
color terminal
Connection DC12V
Note: User must ensure the polarity (Diode) of the wiring connection for additional
anti-duress alarm is arranged correctly so that it is functional. User must also
ensure that Setting Mode (21) Anti-Duress Alarm Mode is set ON.
2 st set N st set
1 st set
8 PIN Connector 8 PIN Connector
8 PIN Connector
R BK BR O Y G BL P R BK BR O Y G BL P
R BK BR O Y G BL P
RS-485 interface
transit connector
DATA+ RS-232
DATA-
communication line
PC
AP-20
AP-10
DC12V +VS
GND
22
7.HARDWARE SPECIFICATIONS
Power supply : DC 12V / 1A, Adapter.
Working environment : Temperature 0℃– 60℃, Humidity: 15% - 85%.
LCD : 16*2 STN LCD display with 4 LED’s indicators.
Buttons : 12 stainless steel buttons.
Real Time Clock : Internal equipped with a Real Time Clock (RTC) IC.
RAM : 128 KB memory.
Power backup system : Equipped with standby battery for saving if power is cut.
Communication system : Equipped internally with RS-485 interface. It can be
expanded to 255 terminals linking with computer operation simultaneously.
Output control system :
(A) Alarm output terminal can be connected with additional external alarm unit for
sounding.
(B) Open door output terminal can be matching used with electric lock for access
control.
(C) Anti-duress output terminal can be connected with hidden alarm to send help signal
to the nearest police station.
Input sensing system :
(A) Push button door open sensing point. Door will open instantly when button is
pressed.
(B) Door status terminal can be connected with external magnetic spring for sensing if
the door is closed or not.
(C) Anti-theft sensing terminal can be connected with external magnetic spring for
sensing if any appliances are closed or not.
(D) Anti-tamper sensing terminal uses to sense if the reader is being tampered by
force.
8. ATTENTIONS
1. Confirm the power supply voltage and polarity before installation to prevent any wrong
connection that causes damage to the reader.
2. Use separate power supply to the electric lock and the proximity reader.
3. Do not install the reader nearby any metal equipments or detector area to prevent
interference of read distance.
4. Do not try to fix or modify the reader without authorized electrician. The reader is
guaranteed for one year.
9. TROUBLESHOOTING
1. Reader has no reaction or door does not open with proximity card.
Solution: (1) Please check if the POWER light (red) is on. If not, please check the power supply
to turn the reader on.
(2) Please check if the proximity card is defected. User may use another proximity card
to test.
(3) Please check if personal password is entered incorrectly or the user is still in the
setup mode.
(4) Continuous proximity. Please remove the card form the reader and try again.
(5) Check if the DENY light (yellow) is on and continuous beep sound occur. This
indicates the user’s proximity card is not registered yet.
(6) Please check if OK light (green) is on and door-opening sound can be heard at the
23
same time. If door is still not opened, please ensure that if the wiring or power
supply of electric lock is installed properly or broken.
2. System password is entered but user cannot enter into various function selection of the
setting mode.
Solution: (1) System password is entered incorrectly. Please check if the following step has
been entered correctly. # X X X X #, (X X X X represent system password), or
press * button first and then enter the correct system password #5678#.
(2) Bad wiring arrangement may affect key enter data. Please confirm that the power
supply wire and the control wire have been arranged to the space at the back of
the LCD (this is the wiring arrangement area of this unit). This is to prevent the
wires pressing on the PC board causing bad contact, short circuit and interference.
24
APPENDIX A
Installation Steps:
Step 1, 2 Secure power supply wire and control wire through the base panel.
Step 3 Fit the reader on the base panel (power supply wire and control wire must first be
inserted and the wires must be arranged correctly)
Step 4 Use enclosed key wrench and screws to mount the reader up.
25