CRJ200.MTCM Lump 2 - 54 - .MTCM060 79 310 001
CRJ200.MTCM Lump 2 - 54 - .MTCM060 79 310 001
CRJ200.MTCM Lump 2 - 54 - .MTCM060 79 310 001
VC 0.02 MECHANIC
REFERENCE DESIGNATION
TASK 72−00−00−200−801 Special Inspection of the Engine
3. Job Set−Up
**ON A/C 7003−7067, 7069−7159
A. Open the access door that follows:
ACCESS DESIGNATION
311AL Ground air supply connection
**ON A/C 7160−7990, 8000−8400
B. Open the access door that follows:
ACCESS DESIGNATION
311BB Aft equipment−compartment door
**ON A/C ALL
4. Procedure
Refer to Figure 1 or 2, as applicable.
A. On aircraft with engine oil detection panels that have magnetic
latch indicators, do the visual check of the engine oil−bypass
indicator as follows:
(1) Make sure that the magnetic latch indicators that follow
are black:
− OIL FILTER LH and RH
(2) If the LH OIL FILTER is black, do the steps that follow:
(a) Push the TEST LH button and make sure that the OIL
FILTER LH indicators change from all black to black
and white.
VC 0.02 MECHANIC
(b) Push the RESET button and make sure that the OIL
FILTER LH indicators change from black and white to
all black.
(3) If the RH OIL FILTER is black, do the steps that follow:
(a) Push the TEST RH button and make sure that the OIL
FILTER RH indicators change from all black to black
and white.
(b) Push the RESET button and make sure that the OIL
FILTER RH indicators change from black and white to
all black.
(4) If any indicator is black and white, do as follow to the
applicable engine:
(a) Do the inspection of engines for metal contamination
of the oil system, as shown by debris on the master
magnetic chip−detector or on the oil filter, refer to
Subtask 72−00−00−210−008 as found in the special
inspection of the engine (Ref. TASK
72−00−00−200−801).
B. On aircraft with engine oil detection panels that has light
emitting diode (LED) indicators, do the visual check of the
engine oil−bypass indicator as follows:
(1) Make sure that the light emitting diode (LED) indicators
that follow are off:
− OIL FILTER LH and RH
− TEST OK
(2) If the LH or RH OIL FILTER (LED) indicator is off, do the
steps that follow:
(a) Push the TEST switch for two seconds, then release.
(b) Make sure that the LED indicators that follow come
on:
− OIL FILTER LH and RH
− TEST OK
(c) Push the RESET switch for two seconds, then
release.
VC 0.02 MECHANIC
ACCESS DESIGNATION
311AL Ground air supply connection
ACCESS DESIGNATION
311BB Aft equipment−compartment door
VC 0.02 MECHANIC
AIRCRAFT EFFECTIVITY:
ENGINE OIL
DETECTION
PANEL
B
GROUND AIR SUPPLY
CONNECTION
(REF)
A
RESET TEST LH TEST RH
OIL FILTER
LH CHIP DETECT RH
LH RH
CHIP DETECT
LH RH
TEST OK
Normal
PANEL WITH
LED INDICATORS Shows unserviceable
condition
rtc79310001_002.dg, cc, 11/08/04
PANEL WITH
MAGNETIC LATCH
INDICATORS
B
ENGINE OIL DETECTION
PANEL
VC 0.02 MECHANIC
AIRCRAFT EFFECTIVITY:
OIL FILTER
LH CHIP DETECT RH
LH RH
CHIP DETECT
A LH RH
TEST OK
Normal
PANEL WITH
LED INDICATORS Shows unserviceable
condition
PANEL WITH
MAGNETIC LATCH
INDICATORS
B
ENGINE OIL DETECTION
PANEL
B
A
AFT EQUIPMENT COMPARTMENT