Variable Displacements Axial Piston Pumps: Edition: 06/06.2020 Replaces: MVP 05 T A
Variable Displacements Axial Piston Pumps: Edition: 06/06.2020 Replaces: MVP 05 T A
Variable Displacements Axial Piston Pumps: Edition: 06/06.2020 Replaces: MVP 05 T A
VARIABLE
DISPLACEMENTS
Headquarters:
AXIAL PISTON
CASAPPA S.p.A.
Via Balestrieri, 1 PUMPS
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: [email protected]
www.casappa.com
MVP
INDEX
Section Page
INTRODUCTION.................................................................................................................................................................. 3
MOUNTING POSITIONS...................................................................................................................................................... 5
FEATURES.......................................................................................................................................................................... 7
DISPLACEMENT SETTING................................................................................................................................................. 12
CENTER OF GRAVITY........................................................................................................................................................ 12
OPERATING CURVES......................................................................................................................................................... 13
DRIVE SHAFTS.................................................................................................................................................................. 32
MOUNTING FLANGES........................................................................................................................................................ 36
PORTS TYPE..................................................................................................................................................................... 38
REGULATORS.................................................................................................................................................................... 41
HOW TO ORDER................................................................................................................................................................ 64
O 06/06.2020
2 DCAT048-ID02
MVP
INTRODUCTION
Variable displacement axial piston pumps swash plate design ideally suited for medium and high pressure open
circuit applications. The compact design allows to be mounted directly on engine motors.
Replaces: 05/10.2014
PRESSURE O z
Mini and Midi-Excavators
Max. constant operating pressure 280 bar (4060 psi) z
Telehandlers
Max. system pressure (relief valve setting) 315 bar (4568 psi) z
Forklifts
Max. peak of pressure 350 bar (5075 psi) z
Windmills - Green Energy
z
Tractors & Attachements
SPEED
Max. 3500 min-1
APPLICATION
Medium, high pressure
SECTOR
Mobile
O
1 2 3 4 5 6
1 Pump body
2 Swash plate
3 Cylinders block
4 Counterbalancing spring
5 Plug
6 Max. displacement limiter
7 Cover
8 Valve plate
9 Min. displacement limiter
10 Piston
11 Piston guide plate
O 06/06.2020
11 10 9 8 7
z
Compact design z
Drive shaft bearing suitable for
z
Longer service life radial and axial loads
z
Low noise emission z
Hydraulic and Electro-hydraulic
displacement controls
z
Max. and min. displacement limiter
GENERAL NOTES
For some configuration the double shaft seals is available.
For more information please consult our pre-sales department.
DCAT048-ID02 3
MVP
FILTRATION STARTING UP
To ensure the optimal performance and the maximum life to Check that all connections are secure and that the entire sys-
the pump, the hydraulic fluid must have and maintain a fluid tem is completely clean. Add oil to the tank always using a
contamination within the values shown in the table below. filter. Bleed the air from the circuit to help the filling. Turn on
the system for a few moments at minimum speed, then bleed
the circuit again and check the level of oil in the tank. Gradually
Working pressure Δp < 140 140 < Δp < 210 Δp > 210 increase the pressure and speed of rotation up to the pre-set
bar (psi) (2030) (2030) (3045) (3045) operating levels, which must stay within the stated limits as
Contamination
specified in the catalogue.
9 8 7
class NAS 1638
Contamination FOR VERY LOW TEMPERATURE
class ISO 20/18/15 19/17/14 18/16/13
4406:1999 STARTING UP
Achieved with We strongly recommend to warm up the oil before running the
filter ßx(c) ≥75 machine. If this is not possible, the warm up of the oil and of
10 μm 10 μm 10 μm
according to ISO the pump should be carried out following these instructions:
16889 • Start the pump in stand-by condition at minimum speed.
Keep this working condition until the pump case reaches
-20 °C (-4 °F)
• Increase slowly the displacement.Max pressure permitted:
Casappa recommends to use its own 50 bar (725 psi). The maximum permitted speed is strictly
production filters: connected to the layout of the inlet circuit; check that there
is no cavitation before increasing the speed.
• Keep this working condition until the oil temperature in the
whole system is -10 °C (14 °F).
STORAGE • Maximum pressure can be achieved from now on.
The storage must be in a dry environment. • Always check the outlet flow to prevent cavitation damage.
05/10.2014
4 DCAT048-ID02
MVP
MOUNTING POSITIONS
O
Standard pump is supplied with D1 drain hole open and D2,
D3, D4 plugged (u if available).
Before installation fill the pump with hydraulic oil for at least
3/4 of the volume keeping it in horizontal position.
Replaces: 03/06.2011
Minimum oil level equal or above Minimum oil level equal or above
the pump mounting face. the pump mounting face.
Minimum oil level below the Minimum oil level below the
pump mounting face. pump mounting face.
Min. inlet pressure= 0,8 bar abs Min. inlet pressure= 0,8 bar abs
(24 in Hg) (24 in Hg)
B ≤ 800 mm (31.4961 in) B ≤ 800 mm (31.4961 in)
C = 200 mm (7.874 in) C = 200 mm (7.874 in)
Arrangement outside the tank above Arrangement outside the tank above
oil level. oil level.
Min. inlet pressure= 0,8 bar abs Min. inlet pressure= 0,8 bar abs
O 06/06.2020
IN= inlet line - D1= drain line - A= min. distance between the line - B+C= permissible suction height - C= line immersion depth
DCAT048-ID02 5
MVP
MVP-MVPD Comparison
28 34
Max. displacement (1.71) (2.07) 45 53 65 72 84
14
Replaces: 05/10.2014
cm3/rev (in3/rev)
(0.85) (2.75) (3.23) (3.97) (4.39) (5.12)
MVPD 30
MVP 30
Pump series
MVPD 48
MVP 48
MVP 60
p1 - p3 p1 - p3 p1 - p3
Working pressure
bar (psi) 230 290 280 350 250 315
- - -
(3335) (4205) (4060) (5075) (3625) (4568)
: MVPD Series. For more information please consult the respective technical catalogue.
PRESSURE DEFINITION
O
p1 Constant operating pressure
p (bar) - (psi)
p1
The peak of pressure is the max pressure allowed and
it corresponds to the overshoot of the relief valve.
6 DCAT048-ID02
MVP
FEATURES
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Max. displacment cm /rev
3
28 34,8 45 53,7 60 72 84,7
(theor.) Vmax (in3/rev) (1.71) (2.12) (2.75) (3.28) (3.66) (4.39) (5.17)
bar abs. 0.8
min.
(in Hg) (24)
Inlet pressure
bar abs. 25
max.
(psi) (363)
280 250 280 250 280 280 250
p1
(4060) (3625) (4060) (3625) (4060) (4060) (3625)
Max. outlet bar 315 280 315 280 315 315 280
p2
pressure pmax (psi) (4568) (4060) (4568) (4060) (4568) (4568) (4060)
350 315 350 315 350 350 315
p3
(5075) (4568) (5075) (4568) (5075) (5075) (4568)
Max. drain line bar abs. 1,5
O
pressure (psi) (22)
Max. speed nmax min-1 @ Vmax (1) 3500 2900 3000 2500 3000 2700 2300 O
98 101 135 134 180 194 212
@ nmax
(25.9) (26.7) (35.7) (35.4) (47.6) (51.3) (56.0)
Max. delivery l/min 56 70 90 107 120 144 169
@ 2000 min-1
(theor.) (US gpm) (14.8) (18.5) (23.8) (28.3) (31.7) (38.0) (44.7)
42 52 68 81 90 108 127
@ 1500 min-1
(11.1) (13.7) (18.0) (21.4) (23.8) (28.5) (33.6)
45,7 42,1 63 55,9 84 90,7 88,2
@ nmax
(61.2) (56.4) (84.4) (74.9) (112.6) (121.5) (118.2)
Max. power
kW 26,1 29 42 44,8 56 67,2 70,6
(theor.) (HP)
@ 2000 min-1
(35.0) (38.9) (56.3) (60.0) (75.0) (90.0) (94.6)
(Δp = pmax cont.)
19,6 21,8 31,5 33,6 42 50,4 52,9
@ 1500 min-1
(26.3) (29.2) (42.2) (45.0) (56.3) (67.5) (70.9)
124,8 138,5 200,5 213,7 267,4 320,9 337
@ pmax cont.
Max. torque Nm (1105) (1226) (1775) (1891) (2367) (2840) (2983)
(theor.) (lbf in) @ 100 bar 44,6 55,4 71,6 85,5 95,5 114,6 134,8
(1450 psi) (395) (490) (634) (757) (845) (1014) (1193)
Moment of inertia kgm2 0,002 0,002 0,003 0,003 0,008 0,008 0,008
rotary group (ft2 lbs) (0.05) (0.05) (0.07) (0.07) (0.19) (0.19) (0.19)
l 0,85 0,85 1 1 1,3 1,3 1,3
Fill volume (US gallons) (0.22) (0.22) (0.26) (0.26) (0.34) (0.34) (0.34)
O 06/06.2020
kg 15 15 19 19 22 22 22
Mass (approx.) (lbs) (33.1) (33.1) (41.9) (41.9) (48.5) (48.5) (48.5)
Seals N= Buna V= Viton
-25 -15
min.
(-13) (5)
Operating °C 80 110
max. cont.
temperature (°F) (176) (230)
100 125
max. peak
(212) (257)
(1) = with an inlet pressure of 1 bar abs (14.5 psi) and viscosity between 15 and 35 cSt (77 and 163 SSU).
Reducing the displacement or increasing the inlet pressure the max. speed changes. See table at page 10.
Max. speed limit are: MVP 30: 3500 m-1 – MVP 48: 3000 m-1 - MVP 60: 3000 m-1
For different working conditions, please consult our pre-sales department.
DCAT048-ID02 7
MVP
FEATURES
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 140 (2030)
Max. outlet
bar (psi) p2 150 (2175)
pressure pmax
p3 160 (2320)
Max. speed nmax min-1 @ Vmax (1) 2200 1800 2000 1700 2000 1700 1500
Seals N= Buna
Operating min. 2 (36)
°C (°F)
temperature max. 55 (131)
Bearing life
% 20 %
(ref. mineral oil)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 160 (2320)
Max. outlet
bar (psi) p2 170 (2465)
pressure pmax
p3 180 (2610)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. 2 (36)
°C (°F)
temperature max. 60 (140)
Bearing life
% 40 %
(ref. mineral oil)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 180 (2610)
Max. outlet
bar (psi) p2 195 (2828)
pressure pmax
p3 210 (3045)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. -10 (14)
°C (°F)
temperature max. 60 (140)
Bearing life
% 40 %
(ref. mineral oil)
8 DCAT048-ID02
MVP
FEATURES
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 200 (2900)
Max. outlet
bar (psi) p2 220 (3190)
pressure pmax
p3 240 (3480)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals V= Viton
Operating min. -10 (14)
°C (°F)
temperature max. 80 (176)
Bearing life
% 90 %
(ref. mineral oil)
HETG - Natural based fluid (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 180 (2610)
Max. outlet
bar (psi) p2 195 (2828)
pressure pmax
p3 210 (3045)
Max. speed nmax min-1 @ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. -10 (14)
°C (°F)
temperature max. 60 (140)
Bearing life
% 50 %
(ref. mineral oil)
HEPG - Polyglycol based synthetic fluid (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 180 (2610)
Max. outlet
bar (psi) p2 195 (2828)
pressure pmax
p3 210 (3045)
Max. speed nmax min-1 @ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals V= Viton
05/10.2014
HEES - Synthetic esters (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Seals V= Viton
Operating min. -15 (5)
°C (°F)
temperature max. 80 (176)
Bearing life
% 100 %0
(ref. mineral oil)
DCAT048-ID02 9
MVP
FEATURES
% Variation of the max. speed in relation of the inlet pressure and/or displacement reduction
Inlet
Displacement %
pressure
psi (bar abs) 65 70 80 90 100
12 (0,8) 120 115 105 97 90
03/06.2011
Example 1 Example 2
Displacement: 100 % Displacement: 80 %
Speed: 100 % Inlet pressure: 1,0 bar abs. (14.5 psi)
Inlet pressure: 1,0 bar abs. (14.5 psi) Speed: 115 %
10 DCAT048-ID02
MVP
FEATURES
Anti-clockwise rotation
Clockwise rotation
DCAT048-ID02 11
MVP
DISPLACEMENT SETTING
Replaces: 05/10.2014
Min. displacement
limiter
Special body without Min. displacement
E: Max. displacement limiter (Min displace- limiter is available only on request, please
ment limiter is plugged) consult our pre-sales department
G: Min. and Max. displacement limiter
cm /rev
3 from 17,4 (1.06) 34,9 (2.13) 55 (3.36)
Max. displacement setting range (in3/rev) to 34,8 (2.12) 53,7 (3.28) 84,7 (5.17)
cm3/rev from 0 0 0
Min. displacement setting range (in3/rev) to 17,4 (1.06) 10,7 (0.65) 38,1 (2.32)
One turn of screw changes pump cm /rev
3 E 2,8 (0.17) 3,2 (0.20) 5,0 (0.31)
displacement by approximately (in3/rev) F 2,3 (0.14) 3,0 (0.18) 4,2 (0.26)
CENTER OF GRAVITY
Center of gravity
12 DCAT048-ID02
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 3500 min-1
Replaces: 03/06.2011
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(31.7) (80.4)
75
100 50
(26.4) (3) (67.0)
72
80 40
(21.1) (53.6) 69
(2)
60 30 66
(15.9) (2) (40.2)
(1)
(1) 63
40 20
(10.6) (26.8)
60
(3) (2)
20 10 (2)
(5.3) (1) (13.4) 57
(1)
0 0 54
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
280 280
p [bar] - [(psi)]
p [bar] - [(psi)]
(4060) (4060)
250 250
(3625) (3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2500 3000 3500 1000 1500 2000 2500 3000 3500
n [min-1] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-ID02 13
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2900 min-1
Replaces: 03/06.2011
Delivery / power Noise level Distance from microphone to
@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
120 60 78
O
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(31.7) (80.4)
75
100 (3) 50
(26.4) (67.0)
72
80 40
(21.1) (53.6) 69 (2)
(2)
60 30 66
(15.9)
(1) (40.2) (1)
63
40 20
(10.6) (2) (26.8)
(3)
60
(1)
20 10 (2)
(5.3) (13.4) 57
(1)
0 0 54
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
250 250
p [bar] - [(psi)]
p [bar] - [(psi)]
(3625) (3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2500 2900 1000 1500 2000 2500 2900
n [min-1] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
14 DCAT048-ID02
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 3000 min-1
Replaces: 03/06.2011
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(42.3) (107.2)
140 70
(37.0) (3) (93.8) 75
120 60
(31.7) (80.4) 72
(2)
100 50
(26.4) (67.0)
(2) 69
(1)
80 40
(21.1) (53.6)
(1) 66
60 30
(15.9) (40.2)
(2)
(3)
63
40 20
(10.6) (26.8)
(2)
20 (1) 10 60
(5.3) (13.4)
(1)
0 0 57
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
280 280
p [bar] - [(psi)]
p [bar] - [(psi)]
(4060) (4060)
250 250
(3625) (3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2500 3000 1000 1500 2000 2500 3000
n [min-1] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-ID02 15
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2500 min-1
Replaces: 03/06.2011
Delivery / power Noise level Distance from microphone to
@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
160 80 78
O
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(42.3) (107.2)
140 70
(37.0) (3) (93.8) 75
120 60 (2)
(31.7) (80.4) 72
(2)
100 50
(26.4) (67.0)
69 (1)
80 (1) 40
(21.1) (53.6)
66
60 30
(2)
(15.9) (40.2)
40 (3) 20
63
(10.6) (26.8)
(1) (2)
20 10 60
(5.3) (13.4)
(1)
0 0 57
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
250 250
p [bar] - [(psi)]
p [bar] - [(psi)]
(3625) (3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2500 1000 1500 2000 2500
n [min-1] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
16 DCAT048-ID02
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 3000 min-1
Replaces: 03/06.2011
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(52.8) (134.0)
(3)
78
160 80
(42.3) (107.2)
75
(2)
120 (2) 60
(31.7) (80.4) 72
(1)
(1)
80 40 69
(21.1) (53.6)
(2)
(3)
66
40 20
(10.6)
(1) (26.8) (2)
63
(1)
0 0 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
280 280
p [bar] - [(psi)]
p [bar] - [(psi)]
(4060) (4060)
250 250
(3625) (3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2500 3000 1000 1500 2000 2500 3000
n [min-1] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-ID02 17
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2700 min-1
Replaces: 03/06.2011
Delivery / power Noise level Distance from microphone to
@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
175 105 81
O
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(46.2) (140.7)
(3)
150 90 78
(39.6) (2) (120.6)
125 75 75
(33.0) (100.5) (2)
(1)
100 60 72
(26.4) (80.4) (1)
75 45
(2)
69
(19.8) (60.3)
(3)
50 30 66
(13.2) (40.2)
(1) (2)
25 15 63
(6.6) (20.1)
(1)
0 0 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
280 280
p [bar] - [(psi)]
p [bar] - [(psi)]
(4060) (4060)
250 250
(3625) (3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2500 2700 1000 1500 2000 2500 2700
n [min-1] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
18 DCAT048-ID02
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2300 min-1 O
Replaces: 05/10.2014
[dB(A)]
Q [l/min] - [(US gpm)]
P [kW] - [(HP)]
(52.8) (134.0)
(3)
78
160 80
(42.3) (2) (107.2)
(2)
75
(1)
120 60 (1)
(31.7) (80.4) 72
(2)
80 40 69
(21.1) (53.6)
(3)
66
40 (1) 20
(10.6) (26.8) (2)
63
(1)
0 0 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]
250 250
p [bar] - [(psi)]
(3625)
p [bar] - [(psi)]
(3625)
200 200
(2900) (2900)
O 06/06.2020
150 150
(2175) (2175)
100 100
(1450) (1450)
50 50
(725) (725)
1000 1500 2000 2300 1000 1500 2000 2300
-1
n [min ] n [min-1]
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-ID02 19
MVP
Replaces: 03/60.2011
IN OUT
D1
O 06/06.2020
20 DCAT048-ID02
MVP
O
Replaces: 03/06.2011
IN OUT
D1
Anti-clockwise rotation
OUT IN
O 06/06.2020
DCAT048-ID02 21
MVP
Replaces: 03/60.2011
IN
D1
110 Nm
974 lbf in
O 06/06.2020
OUT
O Gear pump KAPPA 20 (for more information please consult our pre-sales department)
Pump
type
4 6,3 8 11,2 14 16 20 Dimensions
22 DCAT048-ID02
MVP
O
Replaces: 03/60.2011
IN
D1
110 Nm
974 lbf in
O 06/06.2020
OUT
O Gear pump POLARIS PH20 (for more information please consult our pre-sales department)
Pump Dimen-
type
8 10,5 11,2 14 16 18 19 20 23 24,5 25 27,8 31,5 sions
274,6 278,6 279,1 284,1 287,6 289,8 291 294,1 297,6 299,9 301,6 304,4 311,6 mm
(10.81) (10.97) (10.99) (11.41) (11.32) (11.41) (11.46) (11.58) (11.72) (11.81) (11.87) (11.98) (12.27) (in)
A
MVP30
228 231 231,5 236,5 239,5 230,4 231 232,5 234,2 235,3 236,5 237,9 241,5 mm
(8.98) (9.09) (9.11) (9.31) (9.43) (9.07) (9.09) (9.15) (9.22) (9.26) (9.31) (9.36) (9.51) (in)
B
DCAT048-ID02 23
MVP
Replaces: 03/06.2011
IN OUT
D1
O 06/06.2020
24 DCAT048-ID02
MVP
O
Replaces: 03/06.2011
IN OUT
Anti-clockwise rotation
D1
OUT IN
O 06/06.2020
DCAT048-ID02 25
MVP
Replaces: 03/06.2011
IN
D1
110 Nm
974 lbf in
O 06/06.2020
OUT
Gear pump KAPPA 20 (for more information please consult our pre-sales department)
Pump
type
4 6,3 8 11,2 14 16 20 Dimensions
26 DCAT048-ID02
MVP
O
Replaces: 03/06.2011
IN
D1
110 Nm
974 lbf in
O 06/06.2020
OUT
Gear pump POLARIS PH20 (for more information please consult our pre-sales department)
Pump Dimen-
type
8 10,5 11,2 14 16 18 19 20 23 24,5 25 27,8 31,5 sions
290,1 294,1 294,6 299,6 303,1 305,3 306,5 309,6 313,1 315,4 317,1 319,9 327,1 mm
(11.42) (11.58) (11.60) (11.80) (11.93) (12.02) (12.07) (12.19) (12.33) (12.42) (12.48) (12.59) (12.88) (in)
A
MVP48
243,5 246,5 247 252 255 245,9 246,5 248 249,7 250,8 252 253,4 257 mm
(9.59) (9.70) (9.72) (9.92) (10.04) (9.68) (9.70) (9.76) (9.83) (9.87) (9.92) (9.97) (10.12) (in)
B
DCAT048-ID02 27
MVP
Replaces: 03/06.2011
IN OUT
D1
O 06/06.2020
28 DCAT048-ID02
MVP
O
Replaces: 03/06.2011
IN OUT
D1
Anti-clockwise rotation
OUT IN
O 06/06.2020
DCAT048-ID02 29
MVP
Replaces: 03/06.2011
IN
D1
110 Nm
974 lbf in
O 06/06.2020
OUT
Gear pump KAPPA 20 (for more information please consult our pre-sales department)
Pump
type
4 6,3 8 11,2 14 16 20 Dimensions
30 DCAT048-ID02
MVP
O
Replaces: 03/06.2011
IN
D1
110 Nm
974 lbf in
O 06/06.2020
OUT
O Gear pump POLARIS PH20 (for more information please consult our pre-sales department)
Pump Dimen-
type
8 10,5 11,2 14 16 18 19 20 23 24,5 25 27,8 31,5 sions
328,4 332,4 332,9 337,9 341,4 343,6 344,8 347,9 351,4 353,7 355,4 358,2 365,4 mm
(12.93) (13.09) (13.11) (13.30) (13.44) (13,53) (13.57) (13.70) (13.83) (13.93) (13.99) (14.10) (14.39) (in)
A
MVP60
281,8 284,8 285,3 290,3 293,3 284,2 284,8 286,3 288 289,1 290,3 291,7 295,3 mm
(11.09) (11.21) (11.23) (11.43) (11.55) (11.19) (11.21) (11.27) (11.34) (11.38) (11.43) (11.48) (11.63) (in)
B
DCAT048-ID02 31
MVP
Replaces: 05/10.2014
110 Nm Ext. Involute Spline SAE J498B 170 Nm Ext. Involute Spline ANSI B92.1
973 lbf in with major diameter modified 1505 lbf in with major diameter modified
9 teeth - 16/32 Pitch - 30 deg 11 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 1 Flat root - Side fit - Class 5
270 Nm 290 Nm
2389 lbf in 2566 lbf in
Ext. Involute Spline ANSI B92.1 Ext. Involute Spline ANSI B92.1
with major diameter modified with major diameter modified
13 teeth - 16/32 Pitch - 30 deg 13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5 Flat root - Side fit - Class 5
210 Nm
1858 lbf in
32 DCAT048-ID02
MVP
440 Nm 460 Nm
3894 lbf in 4071 lbf in
Ext. Involute Spline ANSI B92.1
with major diameter modified Ext. Involute Spline ANSI B92.1
15 teeth - 16/32 Pitch - 30 deg with major diameter modified
Flat root - Side fit - Class 5 15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5
210 Nm
1858 lbf in
For different drive shafts, please consult our pre-sales
department.
DCAT048-ID02 33
MVP
Replaces: 05/10.2014
270 Nm Ext. Involute Spline ANSI B92.1
2389 lbf in with major diameter modified
15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5
440 Nm 440 Nm
3894 lbf in 3894 lbf in
Ext. Involute Spline ANSI B92.1 Ext. Involute Spline ANSI B92.1
with major diameter modified with major diameter modified
15 teeth - 16/32 Pitch - 30 deg O 15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5 Flat root - Side fit - Class 5
810 Nm 880 Nm
7169 lbf in 7788 lbf in
34 DCAT048-ID02
MVP
810 Nm
7169 lbf in
O
O 06/06.2020
DCAT048-ID02 35
MVP
Replaces: 05/10.2014
DRIVE SHAFTS DRIVE SHAFTS
See page 32 O See page 32 ÷ 35
Pump Pump
type
03 07 04 type
04 4R 32 05 5R 06 6R 34
MVP30 x x x MVP30 x x x
O 06/06.2020
36 DCAT048-ID02
MVP
MVP60 x x x x x x MVP60 x x x x x x
O 06/06.2020
DCAT048-ID02 37
MVP
PORTS TYPE
Replaces: 03/06.2011
Split Split SAE Gas SAE Gas SAE Gas SAE
Ports type SSM SSS ODT BSPP ODT (l) BSPP (l) ODT BSPP ODT
IN OUT IN OUT IN OUT D1 - D2 - D3 - D4 X X OUT OUT
MVP30 MD MB SD SB OG (n) OD (n) — OB GA 03 GD OC
MVP48 ME MC SE SC OH (n) OF (n) GD OC GA 03 GD OC
MVP60 MF MC SF SC MF OF GD OC GA 03 GD OC
(X) Load sensing port. For more information please consult our pre-sales department.
(l) Standard.
(n) Only for rear ports.
D1
D2
D4 D3
O 06/06.2020
Pump A B C D
type mm (in) mm (in) mm (in) mm (in)
MVP30 28,5 (1.12) 87,5 (3.44) 87,5 (3.44) 87,5 (3.44)
MVP48 36 (1.42) 97 (3.82) — 97 (3.82)
MVP60 37 (1.46) 113 (4.45) 99 (3.90) 99 (3.90)
38 DCAT048-ID02
MVP
PORTS SIZES
SAE FLANGED PORTS J518 - Standard pressure series 3000 psi - Code 61 SSM
Metric thread ISO 60° conforms to ISO/R 262
Nominal
A B C D
CODE
size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
20 47,6 22,2 M 10 45 +2,5
MB 3/4”
(0.79) (1.87) (0.87) 17 (0.67)
—
(398 ÷ 420)
25,4 52,4 26,2 M 10 30 +2,5
MC 1”
(1.00) (2.06) (1.03) 17 (0.67)
—
(266 ÷ 288)
32 58,7 30,2 M 10 20 +1
MD 1” 1/4
(1.26) (2.31) (1.19) 17 (0.67) (177 ÷ 186)
—
SAE FLANGED PORTS J518 - Standard pressure series 3000 psi - Code 61 SSS
American straight thread UNC-UNF 60° conforms to ANSI B 1.1
Nominal
A B C D
CODE
size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
20 47,6 22,2 3/8 - 16 UNC-2B 30 +2,5
SB 3/4”
(0.79) (1.87) (0.87) 17 (0.67)
—
(266 ÷ 288)
03/06.2011
DCAT048-ID02 39
MVP
PORTS SIZES
Replaces: 03/06.2011
SAE STRAIGHT THREAD PORTS J514 ODT
American straight thread UNC-UNF 60° conforms to ANSI B 1.1
Nominal
A ØB ØC D E
CODE
size mm mm mm mm mm Nm Nm
(in) (in) (in) (in) (in) (lbf in) (lbf in)
9,5 12 +1
03 (X) 1/4” 7/16” - 20 UNF - 2B —
(0.37)
— — —
(106 ÷ 115)
33 17 1 20 +1
OB (l) 1/2” 3/4” - 16 UNF - 2B
(1.30) (0.67)
—
(0.04) (177 ÷ 186)
—
35 20,5 2 30 +2,5
OC (l) (1.38) (0.81)
—
(0.08) (266 ÷ 288)
—
5/8” 7/8” - 14 UNF - 2B
34 20,5 17 0,5 70 +5
OC (u) (1.34) (0.81) (0.67) (0.02)
—
(620 ÷ 664)
20 120 +10
OD 3/4” 1 1/16” - 12 UNF - 2B — —
(0.79)
— —
(1062 ÷ 1151) O
30,5 20 170 +10
OF 1” 1 5/16” - 12 UNF - 2B —
(1.20) (0.79)
— —
(1505 ÷ 1593)
20 70 +5
OG 1” 1/4 1 5/8” - 12 UNF - 2B — —
(0.79)
—
(620 ÷ 664)
— O
45 20 100 +5
OH 1” 1/2 1 7/8” - 12 UNF - 2B —
(1.77) (0.79)
—
(885 ÷ 929)
—
(X) = Load sensing port - (l) = Drain port - (u) = KP20 / PHP20 outlet port
O 06/06.2020
Nominal
A ØB ØC D E
CODE
size mm mm mm mm mm Nm Nm
(in) (in) (in) (in) (in) (lbf in) (lbf in)
8,75 12 5 +0,25
GA (X) 1/8” G 1/8 —
(0.34) (0.47)
— —
(44 ÷ 46)
30 19 17 2 20 +1
GD (l) (1.18) (0.75) (0.67) (0.08) (177 ÷ 186)
—
1/2” G 1/2
19 17 50 +2,5
GD (u) —
(0.75) (0.67)
— —
(443 ÷ 465)
(X) = Load sensing port - (l) = Drain port - (u) = KP20 / PHP20 outlet port
40 DCAT048-ID02
MVP
MVP60·84
80 ÷ 250 250 Z OPTION
(1160 ÷ 3625) (3625) Damping restrictor for critical applications.
In case of system instability or pressure oscillations, the
NOTES additional damping restrictor slows down the pump control
For more information, please consult our pre-sales depart- system, damping the regulation transients.
ment. The pump recovery time increases.
The use of the damping restrictor must be evaluated and
OPERATING CURVES approved by Casappa technical sales department for the
Curves have been obtained at the speed of 1500 min-1 and oil specific application.
temperature 50 °C (122 °F).
Max. 4 bar
(58 psi)
Q [l/min] - [(US gpm)]
REMOTE CONTROL
For remote pressure compensator LS3 see page 46.
0
0 280
(4060)
p [bar] - [(psi)]
05/10.2014
t1 t2
Pressure
t [m s ]
DCAT048-ID02 41
MVP
NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information, please consult our pre-sales depart-
ment.
OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil Z Option
temperature 50 °C (122 °F). (See page 41 for more information)
Max. 4 bar
(58 psi) RP1 - LS2 (with flow control)
Q [l/min] - [(US gpm)]
Not included
in supply
0
0 280
(4060)
p [bar] - [(psi)]
05/10.2014
Z Option
(See page 41 for more information)
42 DCAT048-ID02
MVP
NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Connector: Standard type DIN 43650.
For other connectors and more information please consult
our pre-sales department.
OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil
temperature 50 °C (122 °F).
Z Option
(See page 41 for more information)
Max. 4 bar
(58 psi) RP2 - LS2 (with flow control)
Q [l/min] - [(US gpm)]
Not included
in supply
0
0 280
(4060)
p [bar] - [(psi)]
VALVE FEATURES O
Valve
Arrangement Voltage
code
1
O 06/06.2020
Normally closed 12 V DC
2 Normally closed 24 V DC
Z Option
6 Normally open 12 V DC
(See page 41 for more information)
7 Normally open 24 V DC
DCAT048-ID02 43
MVP
Replaces: 05/10.2014
NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information please consult our pre-sales department.
OPERATING CURVES
Z Option
(See page 41 for more information)
Pressure
pA
Normally Normally
PEC - LS2 (with flow control)
closed open
Not included
in supply
pB
I / Imax
X
VALVE FEATURES
O
Connector type DIN 43650/ DEUTSCH DT04-2P
Z Option
Voltage 12 V DC 24 V DC 12 V DC 24 V DC
(See page 41 for more information)
Power 18 W 19 W 18 W 19 W
Resistance
8Ω 30 Ω 8Ω 30 Ω
@ 20 °C (68 °F)
Limit current 1500 mA 800 mA 1500 mA 800 mA
Dither frequency 200 Hz
Operating -40 ÷ 100 °C
temperature (-40 ÷ 212 °F)
44 DCAT048-ID02
MVP
that can be used for different purposes. This signal and the
proportional relief valve allow to realise the following different
control logics by means of an external control unit:
OPERATING CURVES
PECA - LS2 (with flow control)
Pressure
pA Not included
in supply
Normally Normally X
closed open
pB
I / Imax
VALVE FEATURES
O ANGULAR SENSOR
Connector type DIN 43650 DEUTSCH DT04-2P 5
Sensor ouput signal [V]
Voltage 12 V DC 24 V DC 12 V DC 24 V DC
4
Power W 18 W 19 W 18 W 19 W
Resistance
8Ω 30 Ω 8Ω 30 Ω 3
@ 20 °C (68 °F)
Limit current 1500 mA 800 mA 1500 mA 800 mA
2
Dither frequency 200 Hz
DIAG056-001
DCAT048-ID02 45
MVP
Regulates the pump displacement to maintain a constant LS0 (Bleed open) - LS2 (Bleed closed)
(load independent) pressure drop across a flow metering
device. In the standard version the flow compensator is com- Not included
bined with pressure compensator. in supply
X
Differential
Flow Standard
Pressure pressure
compensator setting
compensator setting range
type
bar (psi) bar (psi)
LS0 (n) RPO
12 ÷ 40 14
LS2 (u) RPO (174 ÷ 580) (203)
LS3 (l) RPO
(n): Suggested when the directional control valve does not have
the bleed function
(u): Y is plugged. Suggested when the directional control valve
has the bleed function Y
(l): For remote pressure control.
Z Option
Pilot flow ≈ 1,3 ÷ 1,5 l/min (0.34 ÷ 0.40 US gpm)
(See page 41 for more information)
In standard setting conditions 14 bar (203 psi) the stand-by
LS3 - Remote pressure compensator
pressure is 15±2 bar (218±29 psi).
NOTES X
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Available without pressure compensator RP.
For more information please consult our pre-sales depart-
ment.
OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil Not included
temperature 50 °C (122 °F). in supply
ΔQ
Z Option
(See page 41 for more information)
ΔQ max
05/10.2014
0
-1
0 n [min ] Pump type l/min (US gpm)
t1
Pump Response time [ms]
type (off stroke)
MVP 30 120
t1 MVP 48 120
MVP 60 120
46 DCAT048-ID02
MVP
TORQUE LIMITER RN
For lower torque setting values, the regulator limits the maxi-
mum working pressure to a value lower than the standard
setting for the pressure regulator 280 bar (4060 psi).
When ordering the torque limiter please specify the requested
value of torque [eg. 70 Nm (620 lbf in)] or the requested Z Option
(See page 41 for more information)
power and speed [eg. 10 kW (13.4 HP) at 1500 min-1].
OPERATING CURVES
100
% Q [l/min] - [(US gpm)]
75
Theoretical
05/10.2014
power
Z Option
50
(See page 41 for more information)
25
0
0
p [bar] - [(psi)]
DCAT048-ID02 47
MVP
For lower torque setting values, the regulator limits the maxi-
mum working pressure to a value lower than the standard Y
setting for the pressure regulator 280 bar (4060 psi).
Z Option
When ordering the torque limiter please specify the requested (See page 41 for more information)
value of torque [eg. 70 Nm (620 lbf in)] or the requested
power and speed [eg. 10 kW (13.4 HP) at 1500 min-1].
NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information please consult our pre-sales depart-
ment.
VALVE FEATURES
Valve
Arrangement Voltage
OPERATING CURVES code
1 Normally closed 12 V DC
6 Normally open 12 V DC
7 Normally open 24 V DC
75 Theoretical
power
05/10.2014
DIN 43650
Connector type
DEUTSCH DT04-2P
50
25
0
0
p [bar] - [(psi)]
48 DCAT048-ID02
MVP
Z Option
For lower torque setting values, the regulator limits the maxi- (See page 41 for more information)
mum working pressure to a value lower than the standard
setting for the pressure regulator 280 bar (4060 psi).
When ordering the torque limiter please specify the requested
value of torque [eg. 70 Nm (620 lbf in)] or the requested
power and speed [eg. 10 kW (13.4 HP) at 1500 min-1].
NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Available with or without pressure compensator RP.
For more information please consult our pre-sales depart-
ment.
OPERATING CURVES
100
% Q [l/min] - [(US gpm)]
O 06/06.2020
75
Theoretical
power
50
25
0
0
p [bar] - [(psi)]
DCAT048-ID02 49
MVP
UNLOADING VALVE U ..
Replaces: 05/10.2014
Z Option Z Option
(See page 41 for more information) (See page 41 for more information)
With the valve NC type (normally closed), energizing the With the valve NA type (normally open), energizing the sole-
olenoid valve the displacement is reset and the pump is noid valve the pump works at the maximum displacement.
unloaded.
NOTES
Available without pressure compensator RP.
Connector type: DIN 43650.
For other connectors and more information please consult
our pre-sales department.
VALVE FEATURES O
Valve
Arrangement Voltage
code
U1 Normally closed 12 V DC
U2 Normally closed 24 V DC
O 06/06.2020
U6 Normally open 12 V DC
U7 Normally open 24 V DC
50 DCAT048-ID02
MVP
OPERATING CURVES
Displacement
DMAX
Inverse Direct
DMIN
I / Imax
VALVE FEATURES
Valve
Arrangement Voltage
code
1 Inverse 12 V DC
2 Inverse 24 V DC
6 Direct 12 V DC
7 Direct 24 V DC
DCAT048-ID02 51
MVP
NOTES
06/06.2020
52 DCAT048-ID02
MVP
THROUGH DRIVE
MVP through drive axial piston pumps offer the flexibility to obtain different groups able to supply several hydraulic systems.
The operating characteristics of each assembled pumps are the same as the corresponding single pumps according to the
following conditions:
Replaces: 05/10.2014
Notes: The torque absorbed from the shaft of the first pump results from the sum of the torques due to all the single stages.
The achieved value must not exceed the maximum torque limit given for the shaft of the first pump.
A
Pump
Flanged for Code
type
SAE A AS1
MVP30
SAE B AS5
MVP48 SAE B AS5
MVP60 SAE B AS5
DCAT048-ID02 53
MVP
Replaces: 05/10.2014
IN
D1
Washer 10
OUT
O 06/06.2020
V
70 ±7
(558 ÷ 682)
54 DCAT048-ID02
MVP
ANSI B92.1a-1976
Class 6 - 9 teeth
16/32 Pitch - 30 deg
Flat root - Side fit
Second pump side
DCAT048-ID02 55
MVP
Replaces: 05/10.2014
IN
D1
Washer 12
UNI 5714
Nut M12
UNI 5588-A-8G
Stud M12x30
UNI 5911-8.8 O 06/06.2020
OUT
V
100 ±10
(797 ÷ 974)
56 DCAT048-ID02
MVP
ANSI B92.1a-1976
Class 6 - 13 teeth
16/32 Pitch - 30 deg
Flat root - Side fit
Second pump side
DCAT048-ID02 57
MVP
Replaces: 05/10.2014
IN
D1
Washer 12
UNI 5714
Nut M12
UNI 5588-A-8G
Stud M12x30
UNI 5911-8.8
O 06/06.2020
OUT
V
100 ±10
(797 ÷ 974)
58 DCAT048-ID02
MVP
MAX 200 Nm (1770 lbf in) MAX 250 Nm (2213 lbf in)
DCAT048-ID02 59
MVP
Replaces: 05/10.2014
IN
D1
Washer 12
UNI 5714
Nut M12
UNI 5588-A-8G
Stud M12x30
O 06/06.2020
UNI 5931-8.8
OUT
V
100 ±10
(797 ÷ 974)
60 DCAT048-ID02
MVP
MAX 200 Nm (1770 lbf in) MAX 250 Nm (2213 lbf in)
DCAT048-ID02 61
MVP
Kit cover is available to obtain single pumps starting from the front sections of multiple pumps.
Before closing the intermediate flange check that the coupling has been removed.
1 2 3 4
05/10.2014
62 DCAT048-ID02
MVP
NOTES
06/06.2020
DCAT048-ID02 63
MVP
1 2 3 4 5 6 7 8 ...
MVP30·28 S - 04 S5 - L MD/MB - N - ...
Replaces: 05/10.2014
1 Pump type (max. displacement) Code Code Inlet/outlet ports 6
28 cm /rev (1.74 in /rev)
3 3
MVP 30·28 Nominal size
34,8 cm3/rev (2.12 in3/rev) MVP 30·34 Inlet IN Outlet OUT Pump type
SAE 3000 SAE 3000
45 cm3/rev (2.75 in3/rev) MVP 48·45
SAE FLANGED PORTS METRIC THREAD (SSM)
53,7 cm /rev (3.28 in /rev)
3 3
MVP 48·53
MD/MB 1” 1/4 3/4” MVP 30
60 cm3/rev (3.66 in3/rev) MVP 60·60
ME/MC 1” 1/2 1” MVP 48
72 cm3/rev (4.39 in3/rev) MVP 60·72
MF/MC 2” 1” MVP 60
84,7 cm3/rev (5.17 in3/rev) MVP 60·84
SAE FLANGED PORTS UNC THREAD (SSS)
SD/SB 1” 1/4 3/4” MVP 30
2 Rotation Code SE/SC 1” 1/2 1” MVP 48
Anti-clockwise S SF/SC 2” 1” MVP 60
Clockwise D SAE STRAIGHT THREAD PORTS (ODT)
OG/OD (b) 1” 1/4 3/4” MVP 30 O
3 Drive shaft (a) Code OH/OF (b) 1” 1/2 1” MVP 48
MF/OF 2” 1” MVP 60
SAE “B” spline (13 teeth) 04
SAE “B” spline (13 teeth) 4R
SAE “B” straight 32 Code Seals 7
SAE “BB” spline (15 teeth) 05 N Buna (standard)
SAE “BB” spline (15 teeth) 5R V Viton
SAE “C” spline (14 teeth) 06
SAE “C” spline (14 teeth) 6R
Code Regulators 8
SAE “C” straight 34
... See how to order on page 65 ÷ 67
64 DCAT048-ID02
MVP
8 9 10 11 12 13
Pressure compensator
Replaces: 05/10.2014
RP0 - Z - G
Flow compensator
LS0 - Z - G
Normally closed 24 V DC 2
Normally open 12 V DC 6
Normally open 24 V DC 7
Code O Displacement limiter 13
E Max. displacement limiter
G Min. and Max. displacement limiter
ORDER EXAMPLE
MVP60 pump with dual setting pressure compensator:
MVP60.60S-05S5-LMF/MC-N-RP2-1-S-G
DCAT048-ID02 65
MVP
8 9 10 11 12 13 14 15 16
Electro-proportional pressure
Replaces: 05/10.2014
PEC - 1 - A - ... / ... - D - G
compensator
Electro-proportional pressure
PEC - 1 - A - LS2 - ... / ... - D - G
compensator with flow control
Electro-proportional pressure
compensator plus angular sensor PECA - 1 - A - ... ... D G
Electro-proportional pressure
compensator plus angular sensor PECA - 1 - A - LS2 - ... ... - D - G
with flow control
Unloading valve
O U.. - Z - G
Electro-proportional displace-
O DEC - 1 - LS2 - D - G
ment compensator
Normally closed 12 V DC 1
Code Max. pressure setting 14
Normally closed 24 V DC 2 ... Please specify the requested value in bar
Normally open 12 V DC 6
Normally open 24 V DC 7 Code Connector type 15
S DIN 43650
10 Position Code D Deutsch DT04-2P
O 06/06.2020
Position 0° A
Position 90° B Code O Displacement limiter 16
E Max. displacement limiter
G Min. and Max. displacement limiter
ORDER EXAMPLE
MVP60 pump with electro-proportional pressure compensa-
tor with flow control:
MVP60.60S-05S5-LMF/MC-N-PEC-1-A-LS2-100/300-D-G
66 DCAT048-ID02
MVP
TORQUE LIMITERS
8 9 10 11 12 13 14 15 16
Torque limiter - standard
Replaces: 05/10.2014
Dual setting torque limiter with RN2 - 1 - S - LS2 - Z - G - ... / ... / ...
remote flow control
Normally closed 12 V DC 1
Normally closed 24 V DC 2 Code O Displacement limiter 13
Normally open 12 V DC 6 E Max. displacement limiter
Normally open 24 V DC 7 G Min. and Max. displacement limiter
ORDER EXAMPLE
MVP60 pump with dual setting torque limiter with flow control:
MVP60.60S-05S5-LMF/MC-N-RN2-1-S-LS0-Z-G-150/200/2100
DCAT048-ID02 67
MVP
Common inlet
1 2 3 4 5 6 7 8 ... 9 10 7 11 12 13 14
MVP30·28 S - 04 S5 - L MD/MB - N - ... - G - P7 - A (# / # / #) /
Front section
Replaces: 05/10.2014
KP20·6,3 S - - L **/GD - N5 - N - P
Rear section
68 DCAT048-ID02
MVP
Code Torque limiter setting (#) 12 Omit code only if ordering assembled multiple pumps
(#) Only for torque limiter. Refer to page 67 for more information.
... Please specify the requested torque value in Nm
Write these codes at the end only if ordering assembled
multiple pumps
Code Second torque limiter setting (#) 13 (a) KAPPA 20 gear pumps:
... Please specify the requested torque value in Nm displacements on page 22, 26 and 30. For more information,
please see the respective technical catalogue
Code Torque limiter setting speed (#) 14 (b) POLARIS PH gear pumps
displacements on page 23, 27 and 31. For more information,
... Please specify the requested speed value please see the respective technical catalogue
(c) Drive shafts availability at pages 32 ÷ 35 and mounting
flanges availability at pages 36 ÷ 37
ORDER EXAMPLE
Common inlet double pump MVP 60 with RN1 torque limiter-internal pilot + PHP20 gear pump.
INDIVIDUAL SECTIONS
Front section
MVP 60.60S-06S8-LMF/MC-N-RN1-G-I7-A (100/2500)
DCAT048-ID02 69
MVP
Through drive O
1 2 3 4 5 6 7 8 ... 9 10 11 12 13 14
MVP 60·60 S - 05 S5 - L MF/MC - N - ... - G - AS5 - 04 - (# / # / #) /
Front section (through drive)
Replaces: 05/10.2014
MVP 30·28 S - 04 S5 - L MD/MB - N - ... - G - - - ... / ... / ...
Rear section (single pump)
70 DCAT048-ID02
MVP
... Please specify the requested torque value in Nm (b) Drive shafts availability at pages 32 ÷ 35 and
mounting flanges availability at pages 36 ÷ 37
(c) Intermediate flanges on page 53
Code Torque limiter setting speed (#) 14
(d) Couplings availability:
... Please specify the requested speed value MVP30 on page 55 and 57
MVP48 on page 59
MVP60 on page 61
ORDER EXAMPLE
Through drive double pump MVP 60 with RN2 (dual setting torque limiter with remote flow control) + MVP 30 with LS0 flow
compensator.
INDIVIDUAL SECTIONS
Front section
MVP 60.60S-06S8-LMF/MC-N-RN2-1-S-LS2-G-AS5/04 (70/85/2600)
Rear section
MVP 30.34S-04S5-LMD/MB-N-LS0-Z-G
Through drive double pump MVP 48 with RN0 (standard torque limiter) + KP 30 gear pump.
INDIVIDUAL SECTIONS
Front section
05/10.2014
Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed without notice.
DCAT048-ID02 71
MVP 06 T A Edition: 06/06.2020 Replaces: MVP 05 T A
VARIABLE
DISPLACEMENTS
Headquarters:
AXIAL PISTON
CASAPPA S.p.A.
Via Balestrieri, 1 PUMPS
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: [email protected]
www.casappa.com