Variable Displacements Axial Piston Pumps: Edition: 06/06.2020 Replaces: MVP 05 T A

Download as pdf or txt
Download as pdf or txt
You are on page 1of 72

MVP 06 T A Edition: 06/06.

2020 Replaces: MVP 05 T A

VARIABLE
DISPLACEMENTS
Headquarters:
AXIAL PISTON
CASAPPA S.p.A.
Via Balestrieri, 1 PUMPS
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: [email protected]
www.casappa.com
MVP

INDEX

Section Page

INTRODUCTION.................................................................................................................................................................. 3

GENERAL INFORMATION / INSTRUCTIONS....................................................................................................................... 4

MOUNTING POSITIONS...................................................................................................................................................... 5

DISPLACEMENTS AND WORKING PRESSURES RANGE..................................................................................................... 6

FEATURES.......................................................................................................................................................................... 7

DISPLACEMENT SETTING................................................................................................................................................. 12

CENTER OF GRAVITY........................................................................................................................................................ 12

OPERATING CURVES......................................................................................................................................................... 13

SINGLE PUMPS AND COMMON INLET MULTIPLE PUMPS


DIMENSIONS.................................................................................................................................................................... 20

DRIVE SHAFTS.................................................................................................................................................................. 32

MOUNTING FLANGES........................................................................................................................................................ 36

PORTS TYPE..................................................................................................................................................................... 38

REGULATORS.................................................................................................................................................................... 41

MULTIPLE PUMPS WITH THROUGH DRIVE....................................................................................................................... 53

HOW TO ORDER................................................................................................................................................................ 64
O 06/06.2020

O Modification from former edition.

2 DCAT048-ID02
MVP

INTRODUCTION

Variable displacement axial piston pumps swash plate design ideally suited for medium and high pressure open
circuit applications. The compact design allows to be mounted directly on engine motors.
Replaces: 05/10.2014

DISPLACEMENTS TYPICAL APPLICATIONS


From 14 cm3/rev (0.85 in3/rev) z
Skid Steer Loaders
To 84,7 cm3/rev (5.17 in3/rev) z
Wheel Loaders - Backhoe Loaders

PRESSURE O z
Mini and Midi-Excavators
Max. constant operating pressure 280 bar (4060 psi) z
Telehandlers
Max. system pressure (relief valve setting) 315 bar (4568 psi) z
Forklifts
Max. peak of pressure 350 bar (5075 psi) z
Windmills - Green Energy
z
Tractors & Attachements
SPEED
Max. 3500 min-1

APPLICATION
Medium, high pressure

SECTOR
Mobile
O
1 2 3 4 5 6

1 Pump body
2 Swash plate
3 Cylinders block
4 Counterbalancing spring
5 Plug
6 Max. displacement limiter
7 Cover
8 Valve plate
9 Min. displacement limiter
10 Piston
11 Piston guide plate
O 06/06.2020

11 10 9 8 7

z
Compact design z
Drive shaft bearing suitable for
z
Longer service life radial and axial loads
z
Low noise emission z
Hydraulic and Electro-hydraulic
displacement controls
z
Max. and min. displacement limiter

GENERAL NOTES
For some configuration the double shaft seals is available.
For more information please consult our pre-sales department.

DCAT048-ID02 3
MVP

GENERAL INFORMATION / INSTRUCTIONS

DIRECTION OF ROTATION LINES


Clockwise or anti-clockwise defined looking at the drive shaft. The lines must have a major diameter which is at least as large
as the diameter of pump ports, and must be perfectly sealed.
HYDRAULIC FLUID To reduce loss of power, the lines should be as short as possi-
Mineral oil based hydraulic fluid conforming to DIN 51524, ble, reducing the sources of hydraulic resistance (elbow, throt-
fire resistant fluids and biodegradable fluids according to the tling, gate valves, etc.) to a minimum. A length of flexible tub-
technical data shown in the tables on pages 5 ÷ 7. The system ing is recommended to reduce the transmission of vibrations.
should be designed to prevent aeration of the hydraulic fluid. Before connecting the lines, remove any plug and make sure
that the lines are perfectly clean. Check that the drain line is
FLUID VISCOSITY dimensioned in a way to guarantee a case pressure lower than
The fluid viscosity range for optimal use of MVP pump is 1,5 bar (22 psi) absolute. The drain line must be connected
between 15 and 35 cSt (77 and 163 SSU). directly (no filter, no valves, no oil cooler) to the tank and must
Functional limit conditions are: terminate below the oil level. Check that the dimensions of the
max.: 1500 cSt (6818 SSU) at start up at minimum tempera suction line guarantee a pressure equal or superior to 0,8 bar
ture of -25 °C (-13 °F) with straight and short inlet line. (12 psi). Inlet pressure less than 0,8 bar (12 psi) could cause an
min.: 10 cSt (58 SSU) at maximum temperature of 110 °C increase of noise emission, the decrease of the pump perfor-
(230 °F) mances and a reduction of its life expectancy.

FILTRATION STARTING UP
To ensure the optimal performance and the maximum life to Check that all connections are secure and that the entire sys-
the pump, the hydraulic fluid must have and maintain a fluid tem is completely clean. Add oil to the tank always using a
contamination within the values shown in the table below. filter. Bleed the air from the circuit to help the filling. Turn on
the system for a few moments at minimum speed, then bleed
the circuit again and check the level of oil in the tank. Gradually
Working pressure Δp < 140 140 < Δp < 210 Δp > 210 increase the pressure and speed of rotation up to the pre-set
bar (psi) (2030) (2030) (3045) (3045) operating levels, which must stay within the stated limits as
Contamination
specified in the catalogue.
9 8 7
class NAS 1638
Contamination FOR VERY LOW TEMPERATURE
class ISO 20/18/15 19/17/14 18/16/13
4406:1999 STARTING UP
Achieved with We strongly recommend to warm up the oil before running the
filter ßx(c) ≥75 machine. If this is not possible, the warm up of the oil and of
10 μm 10 μm 10 μm
according to ISO the pump should be carried out following these instructions:
16889 • Start the pump in stand-by condition at minimum speed.
Keep this working condition until the pump case reaches
-20 °C (-4 °F)
• Increase slowly the displacement.Max pressure permitted:
Casappa recommends to use its own 50 bar (725 psi). The maximum permitted speed is strictly
production filters: connected to the layout of the inlet circuit; check that there
is no cavitation before increasing the speed.
• Keep this working condition until the oil temperature in the
whole system is -10 °C (14 °F).
STORAGE • Maximum pressure can be achieved from now on.
The storage must be in a dry environment. • Always check the outlet flow to prevent cavitation damage.
05/10.2014

Max storage time in ideal conditions is 24 months.


The ideal storage temperature is between 5 °C (41 °F) and All the temperature are referred to oil with viscosity ISO VG 32
20 °C (68 °F). No problem in case of temperature between according to DIN 51 519.
-40 °C (-40 °F) and 50 °C (122 °F). Below -40 °C (-40 °F)
please consult our pre-sales department. SUGGESTIONS
To prevent cavitation at low temperature we suggest:
INSTALLATION • To warm up the tank
Check that the maximum coupling eccentricity stays within • To pressurize the tank
0,25 mm (0.0098 in) to reduce shaft loads due to misalign- • To oversize the inlet hose
ment. It is advised to use a flexible coupling suitable to absorb
eventual rotational shocks. For applications with axial and ra-
dial loads exceeding published standards, consult our sales
department. The direction of rotation of the pump must agree
with the prime mover rotation. Before installation, the case of
the pump must be filled with fluid.

4 DCAT048-ID02
MVP

MOUNTING POSITIONS

O
Standard pump is supplied with D1 drain hole open and D2,
D3, D4 plugged (u if available).
Before installation fill the pump with hydraulic oil for at least
3/4 of the volume keeping it in horizontal position.
Replaces: 03/06.2011

The pump can be mounted in a horizontal or vertical position.


The highest of the case drain ports must be used to keep the
required filling oil.
If D1 is not the highest drain port it must be closed by moving
the plug from the hole chosen for the drain line.
The pump can be located above the oil level if the absolute
pressure at the inlet port stays within the stated limits.
With exception of pump mounted below the oil level, we rec-
ommend to interpose a baffle plate between inlet and drain
line.
To reduce further noise emission, we recommend to mount
the pump below the oil level and avoid suction lines with sharp
restrictions.
u u

HORIZONTAL MOUNTING VERTICAL MOUNTING

Arrangement inside the tank. Arrangement inside the tank.

Minimum oil level equal or above Minimum oil level equal or above
the pump mounting face. the pump mounting face.

A ≥ 200 mm (7.874 in) A ≥ 200 mm (7.874 in)

Arrangement inside the tank. Arrangement inside the tank.

Minimum oil level below the Minimum oil level below the
pump mounting face. pump mounting face.

Min. inlet pressure= 0,8 bar abs Min. inlet pressure= 0,8 bar abs
(24 in Hg) (24 in Hg)
B ≤ 800 mm (31.4961 in) B ≤ 800 mm (31.4961 in)
C = 200 mm (7.874 in) C = 200 mm (7.874 in)

Arrangement outside the tank above Arrangement outside the tank above
oil level. oil level.

Min. inlet pressure= 0,8 bar abs Min. inlet pressure= 0,8 bar abs
O 06/06.2020

(24 in Hg) (24 in Hg)


B ≤ 800 mm (31.4961 in) B ≤ 800 mm (31.4961 in)
C = 200 mm (7.874 in) C = 200 mm (7.874 in)

Arrangement outside the tank


below oil level.

C = 200 mm (7.874 in)

IN= inlet line - D1= drain line - A= min. distance between the line - B+C= permissible suction height - C= line immersion depth

DCAT048-ID02 5
MVP

DISPLACEMENTS AND WORKING PRESSURES RANGE

MVP-MVPD Comparison

28 34
Max. displacement (1.71) (2.07) 45 53 65 72 84
14

Replaces: 05/10.2014
cm3/rev (in3/rev)
(0.85) (2.75) (3.23) (3.97) (4.39) (5.12)

 MVPD 30

MVP 30
Pump series

 MVPD 48

MVP 48

MVP 60

p1 - p3 p1 - p3 p1 - p3
Working pressure
bar (psi) 230 290 280 350 250 315
- - -
(3335) (4205) (4060) (5075) (3625) (4568)

: MVPD Series. For more information please consult the respective technical catalogue.

PRESSURE DEFINITION

O
p1 Constant operating pressure
p (bar) - (psi)

p3 p2 System pressure (relief valve setting)


p2 p3 Peak of pressure
O 06/06.2020

p1
The peak of pressure is the max pressure allowed and
it corresponds to the overshoot of the relief valve.

Please note that both relief valve setting and overshoot


must be lower than their limits.
T (s) If the relief setting is compliant but the overshoot is
Max. 20 s Max. 50 ms higher than the limit, the relief setting must be de-
creased until the overshoot is compliant to Casappa
limit.

For high frequency applications please consult our pre-


sales department.

6 DCAT048-ID02
MVP

FEATURES

Technical data with mineral oil

HL or HLP mineral oil based hydraulic fluid to DIN 51524


Replaces: 05/10.2014

Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Max. displacment cm /rev
3
28 34,8 45 53,7 60 72 84,7
(theor.) Vmax (in3/rev) (1.71) (2.12) (2.75) (3.28) (3.66) (4.39) (5.17)
bar abs. 0.8
min.
(in Hg) (24)
Inlet pressure
bar abs. 25
max.
(psi) (363)
280 250 280 250 280 280 250
p1
(4060) (3625) (4060) (3625) (4060) (4060) (3625)
Max. outlet bar 315 280 315 280 315 315 280
p2
pressure pmax (psi) (4568) (4060) (4568) (4060) (4568) (4568) (4060)
350 315 350 315 350 350 315
p3
(5075) (4568) (5075) (4568) (5075) (5075) (4568)
Max. drain line bar abs. 1,5
O
pressure (psi) (22)
Max. speed nmax min-1 @ Vmax (1) 3500 2900 3000 2500 3000 2700 2300 O
98 101 135 134 180 194 212
@ nmax
(25.9) (26.7) (35.7) (35.4) (47.6) (51.3) (56.0)
Max. delivery l/min 56 70 90 107 120 144 169
@ 2000 min-1
(theor.) (US gpm) (14.8) (18.5) (23.8) (28.3) (31.7) (38.0) (44.7)
42 52 68 81 90 108 127
@ 1500 min-1
(11.1) (13.7) (18.0) (21.4) (23.8) (28.5) (33.6)
45,7 42,1 63 55,9 84 90,7 88,2
@ nmax
(61.2) (56.4) (84.4) (74.9) (112.6) (121.5) (118.2)
Max. power
kW 26,1 29 42 44,8 56 67,2 70,6
(theor.) (HP)
@ 2000 min-1
(35.0) (38.9) (56.3) (60.0) (75.0) (90.0) (94.6)
(Δp = pmax cont.)
19,6 21,8 31,5 33,6 42 50,4 52,9
@ 1500 min-1
(26.3) (29.2) (42.2) (45.0) (56.3) (67.5) (70.9)
124,8 138,5 200,5 213,7 267,4 320,9 337
@ pmax cont.
Max. torque Nm (1105) (1226) (1775) (1891) (2367) (2840) (2983)
(theor.) (lbf in) @ 100 bar 44,6 55,4 71,6 85,5 95,5 114,6 134,8
(1450 psi) (395) (490) (634) (757) (845) (1014) (1193)
Moment of inertia kgm2 0,002 0,002 0,003 0,003 0,008 0,008 0,008
rotary group (ft2 lbs) (0.05) (0.05) (0.07) (0.07) (0.19) (0.19) (0.19)
l 0,85 0,85 1 1 1,3 1,3 1,3
Fill volume (US gallons) (0.22) (0.22) (0.26) (0.26) (0.34) (0.34) (0.34)
O 06/06.2020

kg 15 15 19 19 22 22 22
Mass (approx.) (lbs) (33.1) (33.1) (41.9) (41.9) (48.5) (48.5) (48.5)
Seals N= Buna V= Viton
-25 -15
min.
(-13) (5)
Operating °C 80 110
max. cont.
temperature (°F) (176) (230)
100 125
max. peak
(212) (257)

(1) = with an inlet pressure of 1 bar abs (14.5 psi) and viscosity between 15 and 35 cSt (77 and 163 SSU).
Reducing the displacement or increasing the inlet pressure the max. speed changes. See table at page 10.
Max. speed limit are: MVP 30: 3500 m-1 – MVP 48: 3000 m-1 - MVP 60: 3000 m-1
For different working conditions, please consult our pre-sales department.

DCAT048-ID02 7
MVP

FEATURES

(1) = with an inlet pressure of 1 bar abs (14.5 psi) and


Technical data restrictions with fire resistant fluid viscosity between 15 and 35 cSt (77 and 163 SSU).

HFA - Oil emulsion in water (5 ÷ 15 % of oil)

Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 140 (2030)
Max. outlet
bar (psi) p2 150 (2175)
pressure pmax
p3 160 (2320)
Max. speed nmax min-1 @ Vmax (1) 2200 1800 2000 1700 2000 1700 1500
Seals N= Buna
Operating min. 2 (36)
°C (°F)
temperature max. 55 (131)
Bearing life
% 20 %
(ref. mineral oil)

HFB - Water emulsion in oil (40 % of water)

Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 160 (2320)
Max. outlet
bar (psi) p2 170 (2465)
pressure pmax
p3 180 (2610)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. 2 (36)
°C (°F)
temperature max. 60 (140)
Bearing life
% 40 %
(ref. mineral oil)

HFC - Water-glycol (35 ÷ 55 % of water)


05/10.2014

Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 180 (2610)
Max. outlet
bar (psi) p2 195 (2828)
pressure pmax
p3 210 (3045)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. -10 (14)
°C (°F)
temperature max. 60 (140)
Bearing life
% 40 %
(ref. mineral oil)

8 DCAT048-ID02
MVP

FEATURES

(1) = with an inlet pressure of 1 bar abs (14.5 psi) and


Technical data restrictions with fire resistant fluid viscosity between 15 and 35 cSt (77 and 163 SSU).

HFD - Phosphate ester

Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 200 (2900)
Max. outlet
bar (psi) p2 220 (3190)
pressure pmax
p3 240 (3480)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals V= Viton
Operating min. -10 (14)
°C (°F)
temperature max. 80 (176)
Bearing life
% 90 %
(ref. mineral oil)

Technical data restrictions with biodegradable fluids

HETG - Natural based fluid (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 180 (2610)
Max. outlet
bar (psi) p2 195 (2828)
pressure pmax
p3 210 (3045)
Max. speed nmax min-1 @ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. -10 (14)
°C (°F)
temperature max. 60 (140)
Bearing life
% 50 %
(ref. mineral oil)

HEPG - Polyglycol based synthetic fluid (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
p1 180 (2610)
Max. outlet
bar (psi) p2 195 (2828)
pressure pmax
p3 210 (3045)
Max. speed nmax min-1 @ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals V= Viton
05/10.2014

Operating min. -15 (5)


°C (°F)
temperature max. 90 (194)
Bearing life
% 75 %
(ref. mineral oil)

HEES - Synthetic esters (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Seals V= Viton
Operating min. -15 (5)
°C (°F)
temperature max. 80 (176)
Bearing life
% 100 %0
(ref. mineral oil)

DCAT048-ID02 9
MVP

FEATURES

Design calculations for pump

Q l/min (US gpm) Flow Q = Q theor. • ηv

M Nm (lbf in) Torque [l/min]


V (cm3/rev) • n (min-1)
Qtheor. =
P kW (HP) Power 1000
V cm3/rev (in3/rev) Displacement
M theor.
M =
n min-1 Speed ηhm
Δp bar (psi) Pressure [Nm]
Δp (bar) • V (cm3/rev)
ηv= ηv (V, Δp, n) Volumetric efficiency Mtheor.=
62,83
ηhm= ηhm (V, Δp, n) Hydro-mechanical efficiency
P OUT
ηt = ηv • ηhm Overall efficiency PIN =
ηt
[kW]
Δp (bar) • Q (l/min)
POUT =
600

Max. permissible load on drive shaft

MVP MVP MVP MVP MVP MVP MVP


Pump type
30•28 30•34 48•45 48•53 60•60 60•72 60•84

N 1000 1000 1500 1500 2000 2000 2000


Fax Axial force
(lbf) (225) (225) (337) (337) (450) (450) (450)

N 1500 1500 1500 1500 3000 3000 3000


Frad Radial force @ L/2
(lbf) (337) (337) (337) (337) (675) (675) (675)

% Variation of the max. speed in relation of the inlet pressure and/or displacement reduction

Inlet
Displacement %
pressure
psi (bar abs) 65 70 80 90 100
12 (0,8) 120 115 105 97 90
03/06.2011

13 (0,9) 120 120 110 103 95


of the max. speed
% Variation

14.5 (1,0) 120 120 115 107 100


17 (1,2) 120 120 120 113 106
20 (1,4) 120 120 120 120 112
23 (1,6) 120 120 120 120 117
29 (2,0) 120 120 120 120 120

Max. speed must not exceed the limits specified at page 7.

Example 1 Example 2
Displacement: 100 % Displacement: 80 %
Speed: 100 % Inlet pressure: 1,0 bar abs. (14.5 psi)
Inlet pressure: 1,0 bar abs. (14.5 psi) Speed: 115 %

10 DCAT048-ID02
MVP

FEATURES

Definition of rotation direction looking at the drive shaft

Anti-clockwise rotation

Side ports Rear ports

Clockwise rotation

Side ports Rear ports


03/06.2011

DCAT048-ID02 11
MVP

DISPLACEMENT SETTING

Max.displacement Max. displacement


limiter limiter

Replaces: 05/10.2014

Min. displacement
limiter
 Special body without Min. displacement
E: Max. displacement limiter (Min displace- limiter is available only on request, please
ment limiter is plugged) consult our pre-sales department
G: Min. and Max. displacement limiter

Tightening torque 15±1 Nm (124 ÷ 142 lbf in)

MVP30 MVP48 MVP60

cm /rev
3 from 17,4 (1.06) 34,9 (2.13) 55 (3.36)
Max. displacement setting range (in3/rev) to 34,8 (2.12) 53,7 (3.28) 84,7 (5.17)
cm3/rev from 0 0 0
Min. displacement setting range (in3/rev) to 17,4 (1.06) 10,7 (0.65) 38,1 (2.32)
One turn of screw changes pump cm /rev
3 E 2,8 (0.17) 3,2 (0.20) 5,0 (0.31)
displacement by approximately (in3/rev) F 2,3 (0.14) 3,0 (0.18) 4,2 (0.26)

For different setting range, please consult our pre-sales department.

CENTER OF GRAVITY

Center of gravity

L CG1 • m1 + (L INT + L CG2) • m2


M MF = [Nm]
102
O 06/06.2020

MMF: Load moment on mounting flange


L CG : Distance from center of gravity to
L CG1 mounting flange [mm]
m: Weight (kg)
L INT L CG2

MVP30 MVP48 MVP60

L CG1 mm (in) 100 (3.94) 116 (4.57) 120 (4.72)

L CG2 mm (in) 90 (3.54) 99 (3.90) 107 (4.21)

L INT mm (in) 208 (8.19) 233 (9.17) 253 (9.96)

For single pumps refer to L CG2 values


Avarage data, for specific values please consult our pre-sales department.

12 DCAT048-ID02
MVP

MVP30•28 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1

(3) 3500 min-1
Replaces: 03/06.2011

Delivery / power Noise level Distance from microphone to


@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
120 60 78
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(31.7) (80.4)

75
100 50
(26.4) (3) (67.0)
72
80 40
(21.1) (53.6) 69
(2)
60 30 66
(15.9) (2) (40.2)
(1)
(1) 63
40 20
(10.6) (26.8)
60
(3) (2)
20 10 (2)
(5.3) (1) (13.4) 57

(1)
0 0 54
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

280 280
p [bar] - [(psi)]

p [bar] - [(psi)]

(4060) (4060)

250 250
(3625) (3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2500 3000 3500 1000 1500 2000 2500 3000 3500

n [min-1] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

DCAT048-ID02 13
MVP

MVP30•34 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1

(3) 2900 min-1

Replaces: 03/06.2011
Delivery / power Noise level Distance from microphone to
@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
120 60 78
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(31.7) (80.4)

75
100 (3) 50
(26.4) (67.0)
72
80 40
(21.1) (53.6) 69 (2)
(2)
60 30 66
(15.9)
(1) (40.2) (1)

63
40 20
(10.6) (2) (26.8)
(3)
60
(1)
20 10 (2)
(5.3) (13.4) 57

(1)
0 0 54
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

250 250
p [bar] - [(psi)]

p [bar] - [(psi)]

(3625) (3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2500 2900 1000 1500 2000 2500 2900

n [min-1] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

14 DCAT048-ID02
MVP

MVP48•45 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1

(2) 2000 min-1

(3) 3000 min-1
Replaces: 03/06.2011

Delivery / power Noise level Distance from microphone to


@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
160 80 78
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(42.3) (107.2)

140 70
(37.0) (3) (93.8) 75

120 60
(31.7) (80.4) 72
(2)
100 50
(26.4) (67.0)
(2) 69
(1)
80 40
(21.1) (53.6)
(1) 66
60 30
(15.9) (40.2)
(2)
(3)

63
40 20
(10.6) (26.8)
(2)
20 (1) 10 60
(5.3) (13.4)
(1)
0 0 57
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

280 280
p [bar] - [(psi)]

p [bar] - [(psi)]

(4060) (4060)

250 250
(3625) (3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2500 3000 1000 1500 2000 2500 3000

n [min-1] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

DCAT048-ID02 15
MVP

MVP48•53 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1

(3) 2500 min-1

Replaces: 03/06.2011
Delivery / power Noise level Distance from microphone to
@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
160 80 78
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(42.3) (107.2)

140 70
(37.0) (3) (93.8) 75

120 60 (2)
(31.7) (80.4) 72
(2)
100 50
(26.4) (67.0)
69 (1)
80 (1) 40
(21.1) (53.6)
66
60 30
(2)

(15.9) (40.2)

40 (3) 20
63
(10.6) (26.8)
(1) (2)
20 10 60
(5.3) (13.4)
(1)
0 0 57
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

250 250
p [bar] - [(psi)]

p [bar] - [(psi)]

(3625) (3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2500 1000 1500 2000 2500

n [min-1] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

16 DCAT048-ID02
MVP

MVP60•60 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1

(2) 2000 min-1

(3) 3000 min-1
Replaces: 03/06.2011

Delivery / power Noise level Distance from microphone to


@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
200 100 81
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(52.8) (134.0)
(3)
78
160 80
(42.3) (107.2)
75
(2)
120 (2) 60
(31.7) (80.4) 72
(1)
(1)
80 40 69
(21.1) (53.6)
(2)
(3)

66
40 20
(10.6)
(1) (26.8) (2)
63

(1)
0 0 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

280 280
p [bar] - [(psi)]

p [bar] - [(psi)]

(4060) (4060)

250 250
(3625) (3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2500 3000 1000 1500 2000 2500 3000

n [min-1] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

DCAT048-ID02 17
MVP

MVP60•72 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1

(3) 2700 min-1

Replaces: 03/06.2011
Delivery / power Noise level Distance from microphone to
@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
175 105 81
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(46.2) (140.7)
(3)
150 90 78
(39.6) (2) (120.6)

125 75 75
(33.0) (100.5) (2)
(1)
100 60 72
(26.4) (80.4) (1)

75 45
(2)

69
(19.8) (60.3)
(3)

50 30 66
(13.2) (40.2)

(1) (2)
25 15 63
(6.6) (20.1)

(1)
0 0 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

280 280
p [bar] - [(psi)]

p [bar] - [(psi)]

(4060) (4060)

250 250
(3625) (3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2500 2700 1000 1500 2000 2500 2700

n [min-1] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

18 DCAT048-ID02
MVP

MVP60•84 OPERATING CURVES

Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1

(2) 2000 min-1

(3) 2300 min-1 O
Replaces: 05/10.2014

Delivery / power Noise level Distance from microphone to


@ max. displacement pump = 1 m (39.37 in)
@ max. displacement @ min. displacement
200 100 81
O

[dB(A)]
Q [l/min] - [(US gpm)]

P [kW] - [(HP)]
(52.8) (134.0)
(3)
78
160 80
(42.3) (2) (107.2)
(2)
75
(1)
120 60 (1)
(31.7) (80.4) 72
(2)

80 40 69
(21.1) (53.6)
(3)

66
40 (1) 20
(10.6) (26.8) (2)
63

(1)
0 0 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
(725) (1450) (2175) (2900) (3625) (4350) (725) (1450) (2175) (2900) (3625) (4350)
p [bar] - [(psi)] p [bar] - [(psi)]

Volumetric efficiency Overall efficiency


@ max. displacement @ max. displacement

250 250
p [bar] - [(psi)]

(3625)
p [bar] - [(psi)]

(3625)

200 200
(2900) (2900)
O 06/06.2020

150 150
(2175) (2175)

100 100
(1450) (1450)

50 50
(725) (725)
1000 1500 2000 2300 1000 1500 2000 2300
-1
n [min ] n [min-1]

Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.

DCAT048-ID02 19
MVP

MVP30 SIDE PORTS - DIMENSIONS L


Drive shafts: see page 32
Mounting flanges: see page 36
Ports: see page 38 ÷ 40

Replaces: 03/60.2011
IN OUT

D1

O 06/06.2020

20 DCAT048-ID02
MVP

MVP30 REAR PORTS - DIMENSIONS P


Drive shafts: see page 32
Mounting flanges: see page 36
Ports: see page 38 ÷ 40

O
Replaces: 03/06.2011

IN OUT

D1
Anti-clockwise rotation

OUT IN
O 06/06.2020

DCAT048-ID02 21
MVP

MVP30/KP20 MULTIPLE PUMPS - DIMENSIONS L


Common inlet intermediate flange: Drive shafts: see page 32
MVP code P7 Mounting flanges: see page 36
KP20 code N5 Ports: see page 38 ÷ 40

Replaces: 03/60.2011
IN

D1

110 Nm
974 lbf in

O 06/06.2020

OUT

O Gear pump KAPPA 20 (for more information please consult our pre-sales department)
Pump
type
4 6,3 8 11,2 14 16 20 Dimensions

247,5 250 252,5 256 260 265,5 272 mm


A
(9.74) (9.84) (9.94) (10.08) (10.24) (10.45) (10.71) (in)
MVP30
218,5 221 223,5 227 225,5 231 237,5 mm
B
(8.60) (8.70) (8.80) (8.94) (8.86) (9.09) (9.35) (in)

22 DCAT048-ID02
MVP

MVP30/PHP20 MULTIPLE PUMPS - DIMENSIONS L


Common inlet intermediate flange: Drive shafts: see page 32 Also available in
MVP code I7 Mounting flanges: see page 36 combination with PLP20
PHP20 code S7 Ports: see page 38 ÷ 40

O
Replaces: 03/60.2011

IN

D1

110 Nm
974 lbf in
O 06/06.2020

OUT

O Gear pump POLARIS PH20 (for more information please consult our pre-sales department)
Pump Dimen-
type
8 10,5 11,2 14 16 18 19 20 23 24,5 25 27,8 31,5 sions
274,6 278,6 279,1 284,1 287,6 289,8 291 294,1 297,6 299,9 301,6 304,4 311,6 mm
(10.81) (10.97) (10.99) (11.41) (11.32) (11.41) (11.46) (11.58) (11.72) (11.81) (11.87) (11.98) (12.27) (in)
A
MVP30
228 231 231,5 236,5 239,5 230,4 231 232,5 234,2 235,3 236,5 237,9 241,5 mm
(8.98) (9.09) (9.11) (9.31) (9.43) (9.07) (9.09) (9.15) (9.22) (9.26) (9.31) (9.36) (9.51) (in)
B

DCAT048-ID02 23
MVP

MVP48 SIDE PORTS - DIMENSIONS L


Drive shafts: see page 33
Mounting flanges: see page 36
Ports: see page 38 ÷ 40

Replaces: 03/06.2011
IN OUT

D1

O 06/06.2020

24 DCAT048-ID02
MVP

MVP48 REAR PORTS - DIMENSIONS P


Drive shafts: see page 33
Mounting flanges: see page 36
Ports: see page 38 ÷ 40

O
Replaces: 03/06.2011

IN OUT

Anti-clockwise rotation
D1

OUT IN
O 06/06.2020

DCAT048-ID02 25
MVP

MVP48/KP20 MULTIPLE PUMPS - DIMENSIONS L


Common inlet intermediate flange: Drive shafts: see page 33
MVP code P7 Mounting flanges: see page 36
KP20 code N5 Ports: see page 38 ÷ 40

Replaces: 03/06.2011
IN

D1

110 Nm
974 lbf in

O 06/06.2020

OUT

Gear pump KAPPA 20 (for more information please consult our pre-sales department)
Pump
type
4 6,3 8 11,2 14 16 20 Dimensions

263 265,5 268 271,5 275,5 281 287,5 mm


A
(10.35) (10.45) (10.55) (10.69) (10.85) (11.06) (11.32) (in)
MVP48
234 236,5 239 242,5 241 246,5 253 mm
B
(9.21) (9.31) (9.41) (9.55) (9.49) (9.70) (9.96) (in)

26 DCAT048-ID02
MVP

MVP48/PHP20 MULTIPLE PUMPS - DIMENSIONS L


Common inlet intermediate flange: Drive shafts: see page 33 Also available in
MVP code I7 Mounting flanges: see page 36 combination with PLP20
PHP20 code S7 Ports: see page 38 ÷ 40

O
Replaces: 03/06.2011

IN

D1

110 Nm
974 lbf in
O 06/06.2020

OUT

Gear pump POLARIS PH20 (for more information please consult our pre-sales department)
Pump Dimen-
type
8 10,5 11,2 14 16 18 19 20 23 24,5 25 27,8 31,5 sions
290,1 294,1 294,6 299,6 303,1 305,3 306,5 309,6 313,1 315,4 317,1 319,9 327,1 mm
(11.42) (11.58) (11.60) (11.80) (11.93) (12.02) (12.07) (12.19) (12.33) (12.42) (12.48) (12.59) (12.88) (in)
A
MVP48
243,5 246,5 247 252 255 245,9 246,5 248 249,7 250,8 252 253,4 257 mm
(9.59) (9.70) (9.72) (9.92) (10.04) (9.68) (9.70) (9.76) (9.83) (9.87) (9.92) (9.97) (10.12) (in)
B

DCAT048-ID02 27
MVP

MVP60 SIDE PORTS - DIMENSIONS L


Drive shafts: see page 34 ÷ 35
Mounting flanges: see page 36 ÷ 37
Ports: see page 38 ÷ 40

Replaces: 03/06.2011
IN OUT

D1

O 06/06.2020

28 DCAT048-ID02
MVP

MVP60 REAR PORTS - DIMENSIONS P


Drive shafts: see page 34 ÷ 35
Mounting flanges: see page 36 ÷ 37
Ports: see page 38 ÷ 40

O
Replaces: 03/06.2011

IN OUT

D1
Anti-clockwise rotation

OUT IN
O 06/06.2020

DCAT048-ID02 29
MVP

MVP60/KP20 MULTIPLE PUMPS - DIMENSIONS L


Common inlet intermediate flange: Drive shafts: see page 34 ÷ 35
MVP code P7 Mounting flanges: see page 36 ÷ 37
KP20 code N5 Ports: see page 38 ÷ 40

Replaces: 03/06.2011
IN

D1

110 Nm
974 lbf in

O 06/06.2020

OUT

Gear pump KAPPA 20 (for more information please consult our pre-sales department)
Pump
type
4 6,3 8 11,2 14 16 20 Dimensions

301,3 303,8 306,3 309,8 313,8 319,3 325,8 mm


A
(11.86) (11.96) (12.06) (12.20) (12.35) (12.57) (12.83) (in)
MVP60
272,3 274,8 277,3 280,8 279,3 284,8 291,3 mm
B
(10.72) (10.82) (10.92) (11.06) (11.00) (11.21) (11.47) (in)

30 DCAT048-ID02
MVP

MVP60/PHP20 MULTIPLE PUMPS - DIMENSIONS L


Common inlet intermediate flange: Drive shafts: see page 34 ÷ 35 Also available in
MVP code I7 Mounting flanges: see page 36 ÷ 37 combination with PLP20
PHP20 code S7 Ports: see page 38 ÷ 40

O
Replaces: 03/06.2011

IN

D1

110 Nm
974 lbf in
O 06/06.2020

OUT

O Gear pump POLARIS PH20 (for more information please consult our pre-sales department)
Pump Dimen-
type
8 10,5 11,2 14 16 18 19 20 23 24,5 25 27,8 31,5 sions
328,4 332,4 332,9 337,9 341,4 343,6 344,8 347,9 351,4 353,7 355,4 358,2 365,4 mm
(12.93) (13.09) (13.11) (13.30) (13.44) (13,53) (13.57) (13.70) (13.83) (13.93) (13.99) (14.10) (14.39) (in)
A
MVP60
281,8 284,8 285,3 290,3 293,3 284,2 284,8 286,3 288 289,1 290,3 291,7 295,3 mm
(11.09) (11.21) (11.23) (11.43) (11.55) (11.19) (11.21) (11.27) (11.34) (11.38) (11.43) (11.48) (11.63) (in)
B

DCAT048-ID02 31
MVP

MVP30 DRIVE SHAFTS

SAE “A” SPLINE 03 SAE SPLINE 07


Mounting face refers to flange code S1 Mounting face refers to flange code S1
O O

Replaces: 05/10.2014
110 Nm Ext. Involute Spline SAE J498B 170 Nm Ext. Involute Spline ANSI B92.1
973 lbf in with major diameter modified 1505 lbf in with major diameter modified
9 teeth - 16/32 Pitch - 30 deg 11 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 1 Flat root - Side fit - Class 5

SAE “B” SPLINE 04 SAE “B” SPLINE 4R


Mounting face refers to flange code S5
Mounting face refers to flange code S5

270 Nm 290 Nm
2389 lbf in 2566 lbf in
Ext. Involute Spline ANSI B92.1 Ext. Involute Spline ANSI B92.1
with major diameter modified with major diameter modified
13 teeth - 16/32 Pitch - 30 deg 13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5 Flat root - Side fit - Class 5

SAE “B” STRAIGHT 32


Mounting face refers to flange code S5
O 06/06.2020

210 Nm
1858 lbf in

For different drive shafts, please consult our pre-sales department.

32 DCAT048-ID02
MVP

MVP48 DRIVE SHAFTS

SAE “B” SPLINE 04 SAE “B” SPLINE 4R


Mounting face refers to flange code S5 Mounting face refers to flange code S5

270 Nm Ext. Involute Spline ANSI B92.1 290 Nm


2389 lbf in with major diameter modified 2566 lbf in
13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5
Ext. Involute Spline ANSI B92.1
with major diameter modified
13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5

SAE “BB” SPLINE 05 SAE “BB” SPLINE 5R


Mounting face refers to flange code S5 Mounting face refers to flange code S5

440 Nm 460 Nm
3894 lbf in 4071 lbf in
Ext. Involute Spline ANSI B92.1
with major diameter modified Ext. Involute Spline ANSI B92.1
15 teeth - 16/32 Pitch - 30 deg with major diameter modified
Flat root - Side fit - Class 5 15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5

SAE “B” STRAIGHT 32


05/10.2014

Mounting face refers to flange code S5

210 Nm
1858 lbf in
For different drive shafts, please consult our pre-sales
department.

DCAT048-ID02 33
MVP

MVP60 DRIVE SHAFTS

SAE “B” SPLINE 04


Mounting face refers to flange code S5
O

Replaces: 05/10.2014
270 Nm Ext. Involute Spline ANSI B92.1
2389 lbf in with major diameter modified
15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5

SAE “BB” SPLINE 05 SAE “BB” SPLINE 5R


Mounting face refers to flange code S5 Mounting face refers to flange code S5

440 Nm 440 Nm
3894 lbf in 3894 lbf in
Ext. Involute Spline ANSI B92.1 Ext. Involute Spline ANSI B92.1
with major diameter modified with major diameter modified
15 teeth - 16/32 Pitch - 30 deg O 15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5 Flat root - Side fit - Class 5

SAE “C” SPLINE 06 SAE “C” SPLINE 6R


Mounting face refers to flange code S7 and S8 Mounting face refers to flange code S7 and S8
O 06/06.2020

810 Nm 880 Nm
7169 lbf in 7788 lbf in

For different drive shafts, please consult our pre-sales department.

34 DCAT048-ID02
MVP

MVP60 DRIVE SHAFTS

SAE “C” STRAIGHT 34


Mounting face refers to flange code S8
Replaces: 05/10.2014

810 Nm
7169 lbf in

O
O 06/06.2020

For different drive shafts, please consult our pre-sales department.

DCAT048-ID02 35
MVP

MOUNTING FLANGES AND TABLE OF COMPATIBILITY

SAE “A” 2 HOLES S1 SAE “B” 2 HOLES S5


Conforms to SAE J744 Conforms to SAE J744
O

Replaces: 05/10.2014
DRIVE SHAFTS DRIVE SHAFTS
See page 32 O See page 32 ÷ 35
Pump Pump
type
03 07 04 type
04 4R 32 05 5R 06 6R 34

MVP30 x x x MVP30 x x x
O 06/06.2020

X Available combination MVP48 x x x x x


MVP60 x x x x x x
X Available combination

36 DCAT048-ID02
MVP

MOUNTING FLANGES AND TABLE OF COMPATIBILITY

SAE “C” 2 HOLES S7 SAE “C” 4 HOLES S8


Conforms to SAE J744 Conforms to SAE J744
Replaces: 05/10.2014

DRIVE SHAFTS DRIVE SHAFTS


O See page 34 ÷ 35 O See page 34 ÷ 35
Pump Pump
type
04 05 5R 06 6R 34 type
04 05 5R 06 6R 34

MVP60 x x x x x x MVP60 x x x x x x
O 06/06.2020

X Available combination X Available combination

DCAT048-ID02 37
MVP

PORTS TYPE

LOAD SENSING KP20 / PHP20


O INLET / OUTLET PORTS DRAIN PORTS
PORTS (X) GEAR PUMPS

Replaces: 03/06.2011
Split Split SAE Gas SAE Gas SAE Gas SAE
Ports type SSM SSS ODT BSPP ODT (l) BSPP (l) ODT BSPP ODT
IN OUT IN OUT IN OUT D1 - D2 - D3 - D4 X X OUT OUT
MVP30 MD MB SD SB OG (n) OD (n) — OB GA 03 GD OC
MVP48 ME MC SE SC OH (n) OF (n) GD OC GA 03 GD OC
MVP60 MF MC SF SC MF OF GD OC GA 03 GD OC

(X) Load sensing port. For more information please consult our pre-sales department.
(l) Standard.
(n) Only for rear ports.

DRAIN PORTS POSITION

D1
D2

D4 D3
O 06/06.2020

Pump A B C D
type mm (in) mm (in) mm (in) mm (in)
MVP30 28,5 (1.12) 87,5 (3.44) 87,5 (3.44) 87,5 (3.44)
MVP48 36 (1.42) 97 (3.82) — 97 (3.82)
MVP60 37 (1.46) 113 (4.45) 99 (3.90) 99 (3.90)

38 DCAT048-ID02
MVP

PORTS SIZES

Tightening torque for low pressure side port

Tightening torque for high pressure side port

SAE FLANGED PORTS J518 - Standard pressure series 3000 psi - Code 61 SSM
Metric thread ISO 60° conforms to ISO/R 262

Nominal
A B C D
CODE
size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
20 47,6 22,2 M 10 45 +2,5
MB 3/4”
(0.79) (1.87) (0.87) 17 (0.67)

(398 ÷ 420)
25,4 52,4 26,2 M 10 30 +2,5
MC 1”
(1.00) (2.06) (1.03) 17 (0.67)

(266 ÷ 288)
32 58,7 30,2 M 10 20 +1
MD 1” 1/4
(1.26) (2.31) (1.19) 17 (0.67) (177 ÷ 186)

38,1 69,8 35,7 M 12 30 +2,5


ME 1” 1/2
(1.50) (2.75) (1.41) 20 (0.79) (266 ÷ 288)

51 77,8 42,9 M 12 30 +2,5


MF 2”
(2.01) (3.06) (1.69) 20 (0.79) (266 ÷ 288)

SAE FLANGED PORTS J518 - Standard pressure series 3000 psi - Code 61 SSS
American straight thread UNC-UNF 60° conforms to ANSI B 1.1

Nominal
A B C D
CODE
size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
20 47,6 22,2 3/8 - 16 UNC-2B 30 +2,5
SB 3/4”
(0.79) (1.87) (0.87) 17 (0.67)

(266 ÷ 288)
03/06.2011

25,4 52,4 26,2 3/8 - 16 UNC-2B 35 +2,5


SC 1”
(1.00) (2.06) (1.03) 17 (0.67)

(310 ÷ 332)
32 58,7 30,2 7/16 - 14 UNC-2B 25 +1
SD 1” 1/4
(1.26) (2.31) (1.19) 17 (0.67) (221 ÷ 230)

38,1 69,8 35,7 1/2 - 13 UNC-2B 30 +2,5


SE 1” 1/2
(1.50) (2.75) (1.41) 20 (0.79) (266 ÷ 288)

51 77,8 42,9 1/2 - 13 UNC-2B 30 +2,5


SF 2”
(2.01) (3.06) (1.69) 20 (0.79) (266 ÷ 288)

DCAT048-ID02 39
MVP

PORTS SIZES

Tightening torque for low pressure side port

Tightening torque for high pressure side port

Replaces: 03/06.2011
SAE STRAIGHT THREAD PORTS J514 ODT
American straight thread UNC-UNF 60° conforms to ANSI B 1.1

Nominal
A ØB ØC D E
CODE
size mm mm mm mm mm Nm Nm
(in) (in) (in) (in) (in) (lbf in) (lbf in)
9,5 12 +1
03 (X) 1/4” 7/16” - 20 UNF - 2B —
(0.37)
— — —
(106 ÷ 115)
33 17 1 20 +1
OB (l) 1/2” 3/4” - 16 UNF - 2B
(1.30) (0.67)

(0.04) (177 ÷ 186)

35 20,5 2 30 +2,5
OC (l) (1.38) (0.81)

(0.08) (266 ÷ 288)

5/8” 7/8” - 14 UNF - 2B
34 20,5 17 0,5 70 +5
OC (u) (1.34) (0.81) (0.67) (0.02)

(620 ÷ 664)
20 120 +10
OD 3/4” 1 1/16” - 12 UNF - 2B — —
(0.79)
— —
(1062 ÷ 1151) O
30,5 20 170 +10
OF 1” 1 5/16” - 12 UNF - 2B —
(1.20) (0.79)
— —
(1505 ÷ 1593)
20 70 +5
OG 1” 1/4 1 5/8” - 12 UNF - 2B — —
(0.79)

(620 ÷ 664)
— O
45 20 100 +5
OH 1” 1/2 1 7/8” - 12 UNF - 2B —
(1.77) (0.79)

(885 ÷ 929)

(X) = Load sensing port - (l) = Drain port - (u) = KP20 / PHP20 outlet port

GAS STRAIGHT THREAD PORTS BSPP


British standard pipe parallel (55°) conforms to UNI - ISO 228

O 06/06.2020

Nominal
A ØB ØC D E
CODE
size mm mm mm mm mm Nm Nm
(in) (in) (in) (in) (in) (lbf in) (lbf in)
8,75 12 5 +0,25
GA (X) 1/8” G 1/8 —
(0.34) (0.47)
— —
(44 ÷ 46)
30 19 17 2 20 +1
GD (l) (1.18) (0.75) (0.67) (0.08) (177 ÷ 186)

1/2” G 1/2
19 17 50 +2,5
GD (u) —
(0.75) (0.67)
— —
(443 ÷ 465)

(X) = Load sensing port - (l) = Drain port - (u) = KP20 / PHP20 outlet port

40 DCAT048-ID02
MVP

PRESSURE COMPENSATOR RP0

Regulates the pump displacement automatically to mantain


the pressure below the fixed pre-adjusted limit.

Pressure setting Standard


Compensator Pump range setting
type type
bar (psi) bar (psi)
80 ÷ 280 280
MVP30·28 (1160 ÷ 4060) (4060)
80 ÷ 250 250
MVP30·34 (1160 ÷ 3625) (3625)
80 ÷ 280 280
MVP48·45 (1160 ÷ 4060) (4060)
80 ÷ 250 250
RP0 MVP48·53 (1160 ÷ 3625) (3625)
80 ÷ 280 280 Z Option
MVP60·60 (1160 ÷ 4060) (4060)
80 ÷ 280 280
MVP60·72 (1160 ÷ 4060) (4060)

MVP60·84
80 ÷ 250 250 Z OPTION
(1160 ÷ 3625) (3625) Damping restrictor for critical applications.
In case of system instability or pressure oscillations, the
NOTES additional damping restrictor slows down the pump control
For more information, please consult our pre-sales depart- system, damping the regulation transients.
ment. The pump recovery time increases.
The use of the damping restrictor must be evaluated and
OPERATING CURVES approved by Casappa technical sales department for the
Curves have been obtained at the speed of 1500 min-1 and oil specific application.
temperature 50 °C (122 °F).

Max. 4 bar
(58 psi)
Q [l/min] - [(US gpm)]

REMOTE CONTROL
For remote pressure compensator LS3 see page 46.

0
0 280
(4060)
p [bar] - [(psi)]
05/10.2014

RESPONSE AND RECOVERY TIME


According to SAE J745 (using outlet pressure).

t1 t2
Pressure

Pump Response time [ms] Recovery time [ms]


type (off stroke) (on stroke)
MVP30 46 150
MVP48 48 150
MVP60 50 150
t1 t2

t [m s ]

DCAT048-ID02 41
MVP

PRESSURE COMPENSATOR RP1

Regulates the pump displacement automatically to mantain


RP1
the pressure below the fixed pre-adjusted limit.
Designed to work at high frequency ≥ 2 cycle/min and/or at
pressure > 280 bar (4060 psi). X

NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information, please consult our pre-sales depart-
ment.

OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil Z Option
temperature 50 °C (122 °F). (See page 41 for more information)

Max. 4 bar
(58 psi) RP1 - LS2 (with flow control)
Q [l/min] - [(US gpm)]

Not included
in supply

0
0 280
(4060)
p [bar] - [(psi)]

05/10.2014

Z Option
(See page 41 for more information)

42 DCAT048-ID02
MVP

DUAL SETTING PRESSURE COMPENSATOR RP2

Regulates the pump displacement automatically to mantain


RP2
the pressure below two fixed pre-adjusted limits.
The electrically piloted valve allows to switch between the
two different limits.
Replaces: 05/10.2014

NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Connector: Standard type DIN 43650.
For other connectors and more information please consult
our pre-sales department.

OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil
temperature 50 °C (122 °F).
Z Option
(See page 41 for more information)
Max. 4 bar
(58 psi) RP2 - LS2 (with flow control)
Q [l/min] - [(US gpm)]

Not included
in supply

0
0 280
(4060)
p [bar] - [(psi)]

VALVE FEATURES O

Valve
Arrangement Voltage
code
1
O 06/06.2020

Normally closed 12 V DC
2 Normally closed 24 V DC
Z Option
6 Normally open 12 V DC
(See page 41 for more information)
7 Normally open 24 V DC

DCAT048-ID02 43
MVP

ELECTRO-PROPORTIONAL PRESSURE COMPENSATOR PEC

Regulates the pump displacement automatically to mantain PEC


the pressure below the variable limit set through a command
current signal. X

Replaces: 05/10.2014
NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information please consult our pre-sales department.

OPERATING CURVES
Z Option
(See page 41 for more information)
Pressure

pA

Normally Normally
PEC - LS2 (with flow control)
closed open

Not included
in supply
pB

I / Imax
X

VALVE FEATURES

Valve code Arrangement Voltage


1 Normally closed 12 V DC
2 Normally closed 24 V DC
6 Normally open 12 V DC
7 Normally open 24 V DC
O 06/06.2020

O
Connector type DIN 43650/ DEUTSCH DT04-2P
Z Option
Voltage 12 V DC 24 V DC 12 V DC 24 V DC
(See page 41 for more information)
Power 18 W 19 W 18 W 19 W
Resistance
8Ω 30 Ω 8Ω 30 Ω
@ 20 °C (68 °F)
Limit current 1500 mA 800 mA 1500 mA 800 mA
Dither frequency 200 Hz
Operating -40 ÷ 100 °C
temperature (-40 ÷ 212 °F)

44 DCAT048-ID02
MVP

ELECTRO-PROPORTIONAL PRESSURE COMPENSATOR PLUS ANGULAR SENSOR PECA

Regulates the pump displacement automatically to mantain PECA


the pressure below the variable limit set through a com-
mand current signal. The swivel angular sensor converts the X
actual position of the swashplate into a voltage output signal
Replaces: 05/10.2014

that can be used for different purposes. This signal and the
proportional relief valve allow to realise the following different
control logics by means of an external control unit:

• Variable maximum pressure limiter


• Electronic flow compensator with
variable setting (variable Load-Sensing)
• Electronic torque limiter with variable torque setting
• Power limiter
• Flow control
• Working e-modes
NOTES
Not available with MVP30.
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information please consult our pre-sales department. Z Option
(See page 41 for more information)

OPERATING CURVES
PECA - LS2 (with flow control)
Pressure

pA Not included
in supply

Normally Normally X
closed open

pB

I / Imax

VALVE FEATURES

Valve code Arrangement Voltatge


1 Normally closed 12 V DC
2 Normally closed 24 V DC
6 Normally open 12 V DC
7 Normally open 24 V DC
Z Option
(See page 41 for more information)
O 06/06.2020

O ANGULAR SENSOR
Connector type DIN 43650 DEUTSCH DT04-2P 5
Sensor ouput signal [V]

Voltage 12 V DC 24 V DC 12 V DC 24 V DC
4
Power W 18 W 19 W 18 W 19 W
Resistance
8Ω 30 Ω 8Ω 30 Ω 3
@ 20 °C (68 °F)
Limit current 1500 mA 800 mA 1500 mA 800 mA
2
Dither frequency 200 Hz
DIAG056-001

Operating -40 ÷ 100 °C 1


temperature (-40 ÷ 212 °F)
Angular sensor 0
DEUTSCH DTM04-4P 0 25 50 75 100
connector type
Pump displacement [%]

DCAT048-ID02 45
MVP

FLOW COMPENSATOR (Load-sensing) LS

Regulates the pump displacement to maintain a constant LS0 (Bleed open) - LS2 (Bleed closed)
(load independent) pressure drop across a flow metering
device. In the standard version the flow compensator is com- Not included
bined with pressure compensator. in supply
X

Differential
Flow Standard
Pressure pressure
compensator setting
compensator setting range
type
bar (psi) bar (psi)
LS0 (n) RPO
12 ÷ 40 14
LS2 (u) RPO (174 ÷ 580) (203)
LS3 (l) RPO
(n): Suggested when the directional control valve does not have
the bleed function
(u): Y is plugged. Suggested when the directional control valve
has the bleed function Y
(l): For remote pressure control.

Z Option
Pilot flow ≈ 1,3 ÷ 1,5 l/min (0.34 ÷ 0.40 US gpm)
(See page 41 for more information)
In standard setting conditions 14 bar (203 psi) the stand-by
LS3 - Remote pressure compensator
pressure is 15±2 bar (218±29 psi).

NOTES X
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Available without pressure compensator RP.
For more information please consult our pre-sales depart-
ment.

OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil Not included
temperature 50 °C (122 °F). in supply

Curve at variable speed


Q [l/min] - [(US gpm)]

ΔQ

Z Option
(See page 41 for more information)

ΔQ max
05/10.2014

0
-1
0 n [min ] Pump type l/min (US gpm)

RESPONSE TIME MVP 30 0,9 (0.24)


According to SAE J745 (using outlet pressure). MVP 48 1,7 (0.45)
MVP 60 2,5 (0.66)
Pressure

t1
Pump Response time [ms]
type (off stroke)
MVP 30 120

t1 MVP 48 120
MVP 60 120

t [ms] According to SAE J745 (using outlet pressure)

46 DCAT048-ID02
MVP

TORQUE LIMITER RN

Regulates the pump displacement according to the system


RN0 - Standard
pressure, to maintain the pre-adjusted torque value and pro-
tect the prime mover from overload. To have the best torque Torque limitation for closed center valve.
limiter regulation, the pre-adjusted absorbed torque has to be
higher than the value shown in the following table. Not included
in supply

Pump Min. torque Min. power (l)


type Nm (lbf in) kW (HP)
MVP30 45 (398) 7.1 (9,5)
MVP48 61 (540) 9.6 (12,9)
MVP60 97 (859) 15.2 (20,4)

(l) @ 1500 min -1

For lower torque setting values, the regulator limits the maxi-
mum working pressure to a value lower than the standard
setting for the pressure regulator 280 bar (4060 psi).
When ordering the torque limiter please specify the requested
value of torque [eg. 70 Nm (620 lbf in)] or the requested Z Option
(See page 41 for more information)
power and speed [eg. 10 kW (13.4 HP) at 1500 min-1].

RN1 - Internal pilot


NOTES Torque limitation for open center valve.
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Available without pressure compensator RP.
X
For more information please consult our pre-sales depart-
ment.

OPERATING CURVES

100
% Q [l/min] - [(US gpm)]

75
Theoretical
05/10.2014

power

Z Option
50
(See page 41 for more information)

25

0
0
p [bar] - [(psi)]

DCAT048-ID02 47
MVP

DUAL SETTING TORQUE LIMITER RN2

Regulates the pump displacement automatically to mantain


RN2-LS0 / RN2-LS2
the torque below two fixed pre-adjusted limits.
The electrically piloted valve allows to switch between the For LS2 configuration Y is plugged.
two different limits.
Not included
in supply

Pump Min. torque Min. power (l)


type Nm (lbf in) kW (HP)
MVP30 45 (398) 7.1 (9,5)
MVP48 61 (540) 9.6 (12,9)
MVP60 97 (859) 15.2 (20,4)

(l) @ 1500 min -1

For lower torque setting values, the regulator limits the maxi-
mum working pressure to a value lower than the standard Y
setting for the pressure regulator 280 bar (4060 psi).
Z Option
When ordering the torque limiter please specify the requested (See page 41 for more information)
value of torque [eg. 70 Nm (620 lbf in)] or the requested
power and speed [eg. 10 kW (13.4 HP) at 1500 min-1].

NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
For more information please consult our pre-sales depart-
ment.
VALVE FEATURES

Valve
Arrangement Voltage
OPERATING CURVES code
1 Normally closed 12 V DC

100 2 Normally closed 24 V DC


% Q [l/min] - [(US gpm)]

6 Normally open 12 V DC
7 Normally open 24 V DC
75 Theoretical
power
05/10.2014

DIN 43650
Connector type
DEUTSCH DT04-2P
50

25

0
0
p [bar] - [(psi)]

48 DCAT048-ID02
MVP

HIGH PERFORMANCE TORQUE LIMITER RN3

Regulates the pump displacement according to the system


RN3 - Special version
pressure, to maintain the pre-adjusted torque value and pro-
tect the prime mover from overload.
This version is optimized for LS systems. With the standard
torque limiter RN0, in case of a high flow through the LS main Not included
valve the torque absorbed by the pump can be slightly lower in supply
than the pre-adjusted torque value, resulting in a lower flow. X
The RN3 version grants the pre-adjusted torque value even at
high flow through the LS main valve.
To have the best torque limiter regulation, the pre-adjusted
absorbed torque has to be higher than the value shown in the
following table.

Pump Min. torque Min. power (l)


type Nm (lbf in) kW (HP)
MVP30 45 (398) 7.1 (9,5)
MVP48 61 (540) 9.6 (12,9)
MVP60 97 (859) 15.2 (20,4)

(l) @ 1500 min -1

Z Option
For lower torque setting values, the regulator limits the maxi- (See page 41 for more information)
mum working pressure to a value lower than the standard
setting for the pressure regulator 280 bar (4060 psi).
When ordering the torque limiter please specify the requested
value of torque [eg. 70 Nm (620 lbf in)] or the requested
power and speed [eg. 10 kW (13.4 HP) at 1500 min-1].

NOTES
X: Load-sensing port. Dimensions at page 38 ÷ 40.
Available with or without pressure compensator RP.
For more information please consult our pre-sales depart-
ment.

OPERATING CURVES

100
% Q [l/min] - [(US gpm)]
O 06/06.2020

75
Theoretical
power

50

25

0
0
p [bar] - [(psi)]

DCAT048-ID02 49
MVP

UNLOADING VALVE U ..

NC (normally closed) NA (normally open)

Replaces: 05/10.2014
Z Option Z Option
(See page 41 for more information) (See page 41 for more information)

With the valve NC type (normally closed), energizing the With the valve NA type (normally open), energizing the sole-
olenoid valve the displacement is reset and the pump is noid valve the pump works at the maximum displacement.
unloaded.

NOTES
Available without pressure compensator RP.
Connector type: DIN 43650.
For other connectors and more information please consult
our pre-sales department.

VALVE FEATURES O

Valve
Arrangement Voltage
code
U1 Normally closed 12 V DC
U2 Normally closed 24 V DC
O 06/06.2020

U6 Normally open 12 V DC
U7 Normally open 24 V DC

50 DCAT048-ID02
MVP

ELECTRO-PROPORTIONAL DISPLACEMENT COMPENSATOR DEC

Regulates the pump displacement automatically to maintain


DEC
it below the variable limit set through a command current
signal.

OPERATING CURVES
Displacement

DMAX

Inverse Direct

DMIN

I / Imax

VALVE FEATURES

Valve
Arrangement Voltage
code
1 Inverse 12 V DC
2 Inverse 24 V DC
6 Direct 12 V DC
7 Direct 24 V DC

Connector type DIN 43 650 DEUTSCH DT04-2P


Voltage 12 V DC 24 V DC 12 V DC 24 V DC
Power 33 W 33 W
Resistance @ 20 °C (68 °F) 4,4 Ω 17,4 Ω 4,3 Ω 17,5 Ω
Limit current 1700 mA 850 mA 1700 mA 850 mA
Dither frequency 150 Hz 150 Hz
Operating temperature -40 ÷ 100 °C (-40 ÷ 212 °F) -40 ÷ 100 °C (-40 ÷ 212 °F)
O 06/06.2020

DCAT048-ID02 51
MVP

NOTES

06/06.2020

52 DCAT048-ID02
MVP

MULTIPLE PUMPS WITH THROUGH DRIVE

THROUGH DRIVE
MVP through drive axial piston pumps offer the flexibility to obtain different groups able to supply several hydraulic systems.
The operating characteristics of each assembled pumps are the same as the corresponding single pumps according to the
following conditions:
Replaces: 05/10.2014

1) Do not exceed the maximum transmissible torque.


2) The maximum rotational speed is that of the lowest rated speed of the single unit incorporated.

M Nm (lbf in) Torque


V cm3/rev (in3/rev) Displacement Δp (bar) • V (cm3/rev)
Δp bar (psi) Pressure M= [Nm]
62,83 • ηhm
ηhm= ηhm (V, Δp, n) Hydro-mechanical efficiency

Notes: The torque absorbed from the shaft of the first pump results from the sum of the torques due to all the single stages.
The achieved value must not exceed the maximum torque limit given for the shaft of the first pump.

A: Front section (through drive)


B: MVP Rear pump (the same of single pump with side or rear ports)
Gear rear pump are also available, please see the respective technical catalogues.
O 06/06.2020

A
Pump
Flanged for Code
type
SAE A AS1
MVP30
SAE B AS5
MVP48 SAE B AS5
MVP60 SAE B AS5

DCAT048-ID02 53
MVP

MVP30 FRONT SECTION - DIMENSIONS AS1


Through drive SAE A Drive shafts: see page 32 The drawing shows a front section with
Mounting flanges: see page 36 clockwise rotation
Ports: see page 38 ÷ 40

Replaces: 05/10.2014
IN

D1

Washer 10

Screw TCEI M10x25


UNI 5931

OUT
O 06/06.2020

Screws tightening torque Nm (lbf in)

V
70 ±7
(558 ÷ 682)

54 DCAT048-ID02
MVP

MVP30 COUPLINGS - DIMENSIONS

SAE “A” SPLINE 03


Available with flange code AS1

ANSI B92.1a-1976
Class 6 - 9 teeth
16/32 Pitch - 30 deg
Flat root - Side fit
Second pump side

MAX 100 Nm (885 lbf in)

SAE “A” STRAIGHT 31


Available with flange code AS1

SAE “A” Straight


Second pump side

MAX 70 Nm (620 lbf in)


05/10.2014

DCAT048-ID02 55
MVP

MVP30 FRONT SECTION - DIMENSIONS AS5


Through drive SAE B Drive shafts: see page 32 The drawing shows a front section with
Mounting flanges: see page 36 clockwise rotation
Ports: see page 38 ÷ 40

Replaces: 05/10.2014
IN

D1

Washer 12
UNI 5714

Nut M12
UNI 5588-A-8G

Stud M12x30
UNI 5911-8.8 O 06/06.2020

OUT

Nuts tightening torque Nm (lbf in)

V
100 ±10
(797 ÷ 974)

56 DCAT048-ID02
MVP

MVP30 COUPLINGS - DIMENSIONS AS5

SAE “B” SPLINE 04


Available with flange code AS5

ANSI B92.1a-1976
Class 6 - 13 teeth
16/32 Pitch - 30 deg
Flat root - Side fit
Second pump side

MAX 100 Nm (885 lbf in)

SAE “B” STRAIGHT 32


Available with flange code AS5

SAE “B” Straight


Second pump side

MAX 100 Nm (885 lbf in)


05/10.2014

DCAT048-ID02 57
MVP

MVP48 FRONT SECTION - DIMENSIONS AS5


Through drive SAE B Drive shafts: see page 33 The drawing shows a front section with
Mounting flanges: see page 36 clockwise rotation
Ports: see page 38 ÷ 40

Replaces: 05/10.2014
IN

D1

Washer 12
UNI 5714

Nut M12
UNI 5588-A-8G

Stud M12x30
UNI 5911-8.8
O 06/06.2020

OUT

Nuts tightening torque Nm (lbf in)

V
100 ±10
(797 ÷ 974)

58 DCAT048-ID02
MVP

MVP48 COUPLINGS - DIMENSIONS

SAE “B” SPLINE 04 SAE “BB” SPLINE 05


Available with flange code AS5 Available with flange code AS5

ANSI B92.1a-1976 ANSI B92.1a-1976


Class 6 - 13 teeth Class 6 - 15 teeth
16/32 Pitch - 30 deg 16/32 Pitch - 30 deg
Flat root - Side fit Flat root - Side fit
Second pump side Second pump side

MAX 200 Nm (1770 lbf in) MAX 250 Nm (2213 lbf in)

SAE “B” STRAIGHT 32 SAE “BB” STRAIGHT 33


Available with flange code AS5 Available with flange code AS5

SAE “B” Straight SAE “BB” Straight


Second pump side Second pump side
MAX 250 Nm (2213 lbf in) MAX 250 Nm (2213 lbf in)
05/10.2014

DCAT048-ID02 59
MVP

MVP60 FRONT SECTION - DIMENSIONS AS5


Through drive SAE B Drive shafts: see page 34 ÷ 35 The drawing shows a front section with
Mounting flanges: see page 36 ÷ 37 clockwise rotation
Ports: see page 38 ÷ 40

Replaces: 05/10.2014
IN

D1

Washer 12
UNI 5714

Nut M12
UNI 5588-A-8G

Stud M12x30
O 06/06.2020

UNI 5931-8.8

OUT

Screws tightening torque Nm (lbf in)

V
100 ±10
(797 ÷ 974)

60 DCAT048-ID02
MVP

MVP60 COUPLINGS - DIMENSIONS

SAE “B” SPLINE 04 SAE “BB” SPLINE 05


Available with flange code AS5 Available with flange code AS5

Int. involute spline Int. involute spline


similar to ANSI B92.1 similar to ANSI B92.1
13 teeth - 16/32 Pitch 15 teeth - 16/32 Pitch
30 deg - Flat root 30 deg - Flat root
Side fit - Class 7 Side fit - Class 7

Second pump side Second pump side

MAX 200 Nm (1770 lbf in) MAX 250 Nm (2213 lbf in)

SAE “C” SPLINE 06


Available with flange code AS5

Int. involute spline


similar to ANSI B92.1
14 teeth - 12/24 Pitch
30 deg - Flat root
Side fit - Class 7
Second pump side

MAX 430 Nm (3806 lbf in)


05/10.2014

DCAT048-ID02 61
MVP

FRONT SECTION KIT COVER

Kit cover is available to obtain single pumps starting from the front sections of multiple pumps.
Before closing the intermediate flange check that the coupling has been removed.

1 2 3 4

Kit part brake down


1 - Seal
2 - Flange
3 - Washers
4 - Screws

05/10.2014

Front section Kit cover


Pump Flanged A B
type for
Code Code
mm (in) mm (in)
209 14
MVP30 SAE A AS1 62100006
(8.2283) (0.5512)
Screws tightening torque Nm (lbf in)
209
MVP30 V
(8.2283
233 16 20 ±1
MVP48 SAE B AS5 62100007 (159 ÷ 195)
(9.1732) (0.6299)
253
MVP60
(9.9606)

62 DCAT048-ID02
MVP

NOTES
06/06.2020

DCAT048-ID02 63
MVP

HOW TO ORDER SINGLE PUMPS

1 2 3 4 5 6 7 8 ...
MVP30·28 S - 04 S5 - L MD/MB - N - ...

Replaces: 05/10.2014
1 Pump type (max. displacement) Code Code Inlet/outlet ports 6
28 cm /rev (1.74 in /rev)
3 3
MVP 30·28 Nominal size
34,8 cm3/rev (2.12 in3/rev) MVP 30·34 Inlet IN Outlet OUT Pump type
SAE 3000 SAE 3000
45 cm3/rev (2.75 in3/rev) MVP 48·45
SAE FLANGED PORTS METRIC THREAD (SSM)
53,7 cm /rev (3.28 in /rev)
3 3
MVP 48·53
MD/MB 1” 1/4 3/4” MVP 30
60 cm3/rev (3.66 in3/rev) MVP 60·60
ME/MC 1” 1/2 1” MVP 48
72 cm3/rev (4.39 in3/rev) MVP 60·72
MF/MC 2” 1” MVP 60
84,7 cm3/rev (5.17 in3/rev) MVP 60·84
SAE FLANGED PORTS UNC THREAD (SSS)
SD/SB 1” 1/4 3/4” MVP 30
2 Rotation Code SE/SC 1” 1/2 1” MVP 48
Anti-clockwise S SF/SC 2” 1” MVP 60
Clockwise D SAE STRAIGHT THREAD PORTS (ODT)
OG/OD (b) 1” 1/4 3/4” MVP 30 O
3 Drive shaft (a) Code OH/OF (b) 1” 1/2 1” MVP 48
MF/OF 2” 1” MVP 60
SAE “B” spline (13 teeth) 04
SAE “B” spline (13 teeth) 4R
SAE “B” straight 32 Code Seals 7
SAE “BB” spline (15 teeth) 05 N Buna (standard)
SAE “BB” spline (15 teeth) 5R V Viton
SAE “C” spline (14 teeth) 06
SAE “C” spline (14 teeth) 6R
Code Regulators 8
SAE “C” straight 34
... See how to order on page 65 ÷ 67

4 Mounting flange (a) Code

SAE “B” 2 holes S5


SAE “C” 2 holes S7
SAE “C” 4 holes S8

5 Ports position Code


(a) Drive shafts availability at pages 32 ÷ 35 and
O 06/06.2020

Side L mounting flanges availability at pages 36 ÷ 37


Rear P (b) Only for rear ports

64 DCAT048-ID02
MVP

HOW TO ORDER REGULATORS

PRESSURE COMPENSATORS - FLOW COMPENSATORS (Load-sensing)

8 9 10 11 12 13
Pressure compensator
Replaces: 05/10.2014

RP0 - Z - G

Pressure compensator RP1 - Z - G

Pressure compensator with flow


control RP1 - LS2 - Z - G

Dual setting pressure compensa-


tor
RP2 - 1 - Z - S - G

Dual setting pressure compensa-


tor with flow control RP2 - 1 - LS2 - Z - S - G

Flow compensator
LS0 - Z - G

Flow compensator for remote


control LS2 - Z - G

Pressure compensator for remote


control
LS3 - Z - G

8 Regulators type Code Code Flow control option 10


Pressure compensator RP0 LS2 Flow compensator
Pressure compensator RP1
Dual setting pressure compensator RP2 Code Restrictor option 11
Flow compensator LS0
Without restrictor (standard - no code)
Flow compensator for remote control LS2
Z Damping restrictor (only for critical applications)
Pressure compensator for remote control LS3

Code Connector type 12


9 Valve type O Code
S DIN 43650 (standard)
Normally closed 12 V DC 1
D Deutsch DT04-2P
O 06/06.2020

Normally closed 24 V DC 2
Normally open 12 V DC 6
Normally open 24 V DC 7
Code O Displacement limiter 13
E Max. displacement limiter
G Min. and Max. displacement limiter

ORDER EXAMPLE
MVP60 pump with dual setting pressure compensator:
MVP60.60S-05S5-LMF/MC-N-RP2-1-S-G

DCAT048-ID02 65
MVP

HOW TO ORDER REGULATORS

ELECTRO-PROPORTIONAL PRESSURE AND DISPLACEMENT COMPENSATORS - UNLOADING VALVES

8 9 10 11 12 13 14 15 16
Electro-proportional pressure

Replaces: 05/10.2014
PEC - 1 - A - ... / ... - D - G
compensator

Electro-proportional pressure
PEC - 1 - A - LS2 - ... / ... - D - G
compensator with flow control

Electro-proportional pressure
compensator plus angular sensor PECA - 1 - A - ... ... D G

Electro-proportional pressure
compensator plus angular sensor PECA - 1 - A - LS2 - ... ... - D - G
with flow control
Unloading valve
O U.. - Z - G

Electro-proportional displace-
O DEC - 1 - LS2 - D - G
ment compensator

8 Regulators type (a) Code Code Flow control option 11


Electro-proportional pressure compensator PEC LS2 Flow compensator for remote control
Electro-proportional pressure compensator and
PECA
swashplate angular sensor (a)
Code Restrictor option 12
Unloading valve - Normally closed 12 V DC U1
Without restrictor (standard - no code)
Unloading valve - Normally closed 24 V DC U2
Z Damping restrictor (only for critical applications)
Unloading valve - Normally open 12 V DC U6
Unloading valve - Normally open 24 V DC U7
Electro-proportional displacement compensator DEC Code Min. pressure setting 13
... Please specify the requested value in bar

9 Valve type Code

Normally closed 12 V DC 1
Code Max. pressure setting 14
Normally closed 24 V DC 2 ... Please specify the requested value in bar

Normally open 12 V DC 6
Normally open 24 V DC 7 Code Connector type 15
S DIN 43650
10 Position Code D Deutsch DT04-2P
O 06/06.2020

Position 0° A
Position 90° B Code O Displacement limiter 16
E Max. displacement limiter
G Min. and Max. displacement limiter

(a) PECA: not available with MVP 30

ORDER EXAMPLE
MVP60 pump with electro-proportional pressure compensa-
tor with flow control:

MVP60.60S-05S5-LMF/MC-N-PEC-1-A-LS2-100/300-D-G

66 DCAT048-ID02
MVP

HOW TO ORDER REGULATORS

TORQUE LIMITERS

8 9 10 11 12 13 14 15 16
Torque limiter - standard
Replaces: 05/10.2014

RN0 - Z - G - ... / ...

Torque limiter - internal pilot


RN1 - Z - G - ... / ...

Dual setting torque limiter with


RN2 - 1 - S - LS0 - Z - G - ... / ... / ...
flow control

Dual setting torque limiter with RN2 - 1 - S - LS2 - Z - G - ... / ... / ...
remote flow control

High performance torque limiter


O RN3 - Z - G - ... / ...

8 Regulators type Code Code Flow control option 11


Torque limiter - standard RN0 LS0 Flow compensator
Torque limiter - internal pilot RN1 LS2 Flow compensator for remote control
Dual setting torque limiter with flow control RN2
High performance torque limiter RN3 Code Restrictor option 12
Without restrictor (standard - no code)
9 Valve type Code Z Damping restrictor (only for critical applications)

Normally closed 12 V DC 1
Normally closed 24 V DC 2 Code O Displacement limiter 13
Normally open 12 V DC 6 E Max. displacement limiter
Normally open 24 V DC 7 G Min. and Max. displacement limiter

10 Connector type Code Code Torque limiter setting (a) 14


DIN 43650 (standard) S ... Please specify the requested torque value in Nm
Deutsch DT04-2P D
Code Second torque limiter setting (a) 15
... Please specify the requested torque value in Nm
O 06/06.2020

Code Torque limiter setting speed (b) 16


... Please specify the requested speed value

(a) Refer to page 47 ÷ 49 for more information


(b) Do not exceed the maximum speed shown on page 7 ÷ 9

ORDER EXAMPLE
MVP60 pump with dual setting torque limiter with flow control:
MVP60.60S-05S5-LMF/MC-N-RN2-1-S-LS0-Z-G-150/200/2100

DCAT048-ID02 67
MVP

HOW TO ORDER MULTIPLE PUMPS - PISTON PUMP/GEAR PUMP

Common inlet

1 2 3 4 5 6 7 8 ... 9 10 7 11 12 13 14
MVP30·28 S - 04 S5 - L MD/MB - N - ... - G - P7 - A (# / # / #) /
Front section

Replaces: 05/10.2014
KP20·6,3 S - - L **/GD - N5 - N - P
Rear section

1 Pump type (max. displacement) Code Code Inlet/outlet ports 6


Front section - The same of single pumps MVP ... Nominal size
Rear section - KAPPA 20 gear pumps (a) KP 20 ... Inlet IN Outlet OUT Pump type
SAE 3000 SAE 3000
Rear section - POLARIS PH gear pumps (b) PHP 20 ...
SAE FLANGED PORTS UNC THREAD (SSS)
SD/SB 1” 1/4 3/4” MVP 30
2 Rotation Code
SE/SC 1” 1/2 1” MVP 48
Anti-clockwise S
SF/SC 2” 1” MVP 60
Clockwise D
SAE STRAIGHT THREAD PORTS (ODT)
— — MVP 30
3 Drive shaft (c) Code
O
— — MVP 48
SAE “B” spline (13 teeth) 04
MF/OF 2” 1” MVP 60
SAE “B” spline (13 teeth) 4R
SAE “B” straight 32
SAE “BB” spline (15 teeth) 05 Code Seals 7
SAE “BB” spline (15 teeth) 5R N Buna (standard)
SAE “C” spline (14 teeth) 06 V Viton
SAE “C” spline (14 teeth) 6R
SAE “C” straight 34 Code Regulators 8
... See how to order on page 65 ÷ 67
4 Mounting flange (c) Code

SAE “B” 2 holes S5


Code O Displacement limiter 9
SAE “C” 2 holes S7
E Max. displacement limiter
SAE “C” 4 holes S8
G Min. and Max. displacement limiter

5 Ports position Code

Side L Code Intermediate flange 10


FRONT SECTION
6 Inlet/outlet ports (a) - (b) Code P7 Flanged for KP20
O 06/06.2020

Nominal size I7 Flanged for PHP20


Pump type Inlet IN Outlet OUT
REAR SECTION
SAE 3000 SAE 6000
N5 Kappa 20 (common inlet)
SAE FLANGED PORTS METRIC THREAD (SSM)
S7 Polaris PHP 20 (common inlet)
MVP 30 1” 1/4 3/4” MD/MB
MVP 48 1” 1/2 1” ME/MC
MVP 60 2” 1” 1/4 MF/MC Code Sections 11
A Front
P Rear

68 DCAT048-ID02
MVP

HOW TO ORDER MULTIPLE PUMPS - PISTON PUMP/GEAR PUMP

Code Torque limiter setting (#) 12 Omit code only if ordering assembled multiple pumps
(#) Only for torque limiter. Refer to page 67 for more information.
... Please specify the requested torque value in Nm
Write these codes at the end only if ordering assembled
multiple pumps
Code Second torque limiter setting (#) 13 (a) KAPPA 20 gear pumps:
... Please specify the requested torque value in Nm displacements on page 22, 26 and 30. For more information,
please see the respective technical catalogue

Code Torque limiter setting speed (#) 14 (b) POLARIS PH gear pumps
displacements on page 23, 27 and 31. For more information,
... Please specify the requested speed value please see the respective technical catalogue
(c) Drive shafts availability at pages 32 ÷ 35 and mounting
flanges availability at pages 36 ÷ 37

ORDER EXAMPLE

Common inlet double pump MVP 60 with RN1 torque limiter-internal pilot + PHP20 gear pump.

INDIVIDUAL SECTIONS

Front section
MVP 60.60S-06S8-LMF/MC-N-RN1-G-I7-A (100/2500)

Rear section PHP 20.23S-L **/GD-S7-N-P

ASSEMBLED DOUBLE PUMP

MVP 60.60S-06S8-LMF/MC-N-RN1-G/PHP 20.23-L**/GD (100/2500)


05/10.2014

DCAT048-ID02 69
MVP

HOW TO ORDER MULTIPLE PUMPS - PISTON PUMP/PISTON PUMP

Through drive O

1 2 3 4 5 6 7 8 ... 9 10 11 12 13 14
MVP 60·60 S - 05 S5 - L MF/MC - N - ... - G - AS5 - 04 - (# / # / #) /
Front section (through drive)

Replaces: 05/10.2014
MVP 30·28 S - 04 S5 - L MD/MB - N - ... - G - - - ... / ... / ...
Rear section (single pump)

1 Pump type (max. displacement) Code Code Inlet/outlet ports 6


Front section MVP (the same of single pumps) (a) MVP ... Nominal size
Rear section MVP (the same of single pumps) (a) MVP ... Inlet IN Outlet OUT Pump type
SAE 3000 SAE 3000
SAE STRAIGHT THREAD PORTS (ODT)
2 Rotation Code
— — MVP 30
Anti-clockwise S O
— — MVP 48
Clockwise D
MF/OF 2” 1” MVP 60

3 Drive shaft (b) Code

SAE “B” spline (13 teeth) 04 Code Seals 7


SAE “B” spline (13 teeth) 4R N Buna (standard)
SAE “B” straight 32 V Viton
SAE “BB” spline (15 teeth) 05
SAE “BB” spline (15 teeth) 5R Code Regulators 8
SAE “C” spline (14 teeth) 06 ... See how to order on page 65 ÷ 67
SAE “C” spline (14 teeth) 6R
SAE “C” straight 34
Code O Displacement limiter 9
4 Mounting flange (b) Code E Max. displacement limiter
G Min. and Max. displacement limiter
SAE “B” 2 holes S5
SAE “C” 2 holes S7
SAE “C” 4 holes S8 Code Intermediate flange (c) 10
AS1 SAE “A” 2 holes
5 Ports position Code AS5 SAE “B” 2 holes
Side L

Code Coupling (d) 11


6 Inlet/outlet ports Code
03 SAE “A” spline (9 teeth)
Nominal size
31 SAE “A” straight
O 06/06.2020

Pump type Inlet IN Outlet OUT


SAE 3000 SAE 6000 04 SAE “B” spline (13 teeth)
SAE FLANGED PORTS METRIC THREAD (SSM) 32 SAE “B” straight
MVP 30 1” 1/4 3/4” MD/MB 05 SAE “BB” spline (15 teeth)
MVP 48 1” 1/2 1” ME/MC 33 SAE “BB” straight
MVP 60 2” 1” 1/4 MF/MC 06 SAE “C” spline (14 teeth)
SAE FLANGED PORTS UNC THREAD (SSS)
MVP 30 1” 1/4 3/4” SD/SB Code Torque limiter setting (#) 12
MVP 48 1” 1/2 1” SE/SC ... Please specify the requested torque value in Nm
MVP 60 2” 1” SF/SC

70 DCAT048-ID02
MVP

HOW TO ORDER MULTIPLE PUMPS - PISTON PUMP/PISTON PUMP

Code Second torque limiter setting (#) 13 (a) Displacements on page 64

... Please specify the requested torque value in Nm (b) Drive shafts availability at pages 32 ÷ 35 and
mounting flanges availability at pages 36 ÷ 37
(c) Intermediate flanges on page 53
Code Torque limiter setting speed (#) 14
(d) Couplings availability:
... Please specify the requested speed value MVP30 on page 55 and 57
MVP48 on page 59
MVP60 on page 61

Omit code only if ordering assembled multiple pumps


(#) Only for torque limiter. Refer to page 67 for more information.

ORDER EXAMPLE

Through drive double pump MVP 60 with RN2 (dual setting torque limiter with remote flow control) + MVP 30 with LS0 flow
compensator.

INDIVIDUAL SECTIONS

Front section
MVP 60.60S-06S8-LMF/MC-N-RN2-1-S-LS2-G-AS5/04 (70/85/2600)

Rear section
MVP 30.34S-04S5-LMD/MB-N-LS0-Z-G

ASSEMBLED DOUBLE PUMP

MVP 60.60S-06S8-LMF/MC-N-RN2-1-S-LS2-G (70/85/2600)/ MVP 30.34S-04S5-LMD/MB-N-LS0-Z-G

Through drive double pump MVP 48 with RN0 (standard torque limiter) + KP 30 gear pump.

INDIVIDUAL SECTIONS

Front section
05/10.2014

MVP 48.45S-04S5-LME/MC-N-RN0-G-AS5/04 (80/2300)

Rear section KP30.51S0-04S5-LED/EB-N-P

ASSEMBLED DOUBLE PUMP

POMPA MVP 48.45S-04S5-LME/MC-N-RN0-G/KP30.51-04S5-LED/EB (80/2300)

Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed without notice.

DCAT048-ID02 71
MVP 06 T A Edition: 06/06.2020 Replaces: MVP 05 T A

VARIABLE
DISPLACEMENTS
Headquarters:
AXIAL PISTON
CASAPPA S.p.A.
Via Balestrieri, 1 PUMPS
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: [email protected]
www.casappa.com

You might also like