Mitsubishi: Notification of The MELSEC-Q Series PLC CPU Upgrade (Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU)
Mitsubishi: Notification of The MELSEC-Q Series PLC CPU Upgrade (Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU)
2000 No.135E
MITSUBISHI NEW PRODUCT RELEASE
GENERAL-PURPOSE
PROGRAMMABLE LOGIC CONTROLLERS
Notification of the MELSEC-Q Series PLC CPU Upgrade
(Q02CPU,Q02HCPU,Q06HCPU,Q12HCPU,Q25HCPU)
New!
The following functions have been added to the QCPU to make it even easier to use.
The additional functions are shown as follows.
!Overwriting on the standard ROM made possible with the memory card
(Automatic write to standard ROM)
When ROM operations are being performed with the standard ROM, it is possible to write over the parameters
and programs in the standard ROM directly from a memory card at the field without PC (GX Developer).
!Debug on Line
(Forced ON/OFF of external inputs/outputs)
System debug with forcibly switch the I/O (X, Y) to ON/OFF by GX Developer is possible on Line.
PULL
Slot 2:PLC No.4
PULL PULL
USB USB
1 1 1 1 2 2 2 Setting of
USER USER USER USER
BAT BAT BAT BAT
BOOT BOOT BOOT BOOT
in QCPU1
*1: Motion CPUs are CPU modules that are connected to Mitsubishi servo amplifiers with SSCNET (which
reduces wiring and afford highly reliable connections) in order to perform motion control.
This enables synchronous operations with the servo motors and the simple structuring of absolute
position systems.
The motion CPUs will be released soon.
*2: The CPU slot (slot on the right of the power supply module) accepts only the QCPU.
(2) Features
(a) Possible to incorporate sequence control and motion control in one PLC system
It is possible to select the most suitable CPU module from the PLC CPUs (five types) and motion CPUs
(two types) in accordance with the size and use of the system when structuring systems.
PULL
Motion control
Enables sequence control and
motion control in one system
(b) High-speed control by dispersing the load brought about by control tact
By separating and isolating CPU modules for each control item, such as machine control and data
processing, it is possible to enable high-speed control without affecting data processing or other
processes.
Data processing (slow) (Less than 1ms control) (Several to several 10ms control)
Machine control (fast) Machine controlling CPU Data processing CPU
Q25HCPU QJ71BR11 QX10 QX10 QX41 Q25HCPU Q25HCPU QX10 QX10 QX41 QJ71BR11
Q61P-A1 POWER RUN MNG Q61P-A1 POWER RUN MNG
MODE T.PASS D.LINK MODE MODE T.PASS D.LINK
RUN SD RD RUN RUN SD RD
ERR ERR ERR ERR
ERR ERR ERR
USER USER USER
BAT BAT BAT
BOOT BOOT BOOT
PULL PULL
(c) CPU modules additions make it possible to expand the program memory and the number of devices
As it is not necessary to change I/O numbers when adding CPU modules, it is possible to expand
program memory and the number of devices without having to amend existing programs.
PU LL PU LL
PU LL PU LL PU LL
in use
(d) Possible to continue operations with other CPU modules even when one CPU module goes down
As the operations (continue/stop) for other CPU modules can be set with parameters when one CPU
module goes down, it is possible to keep the damage to the entire system at a minimum when an error
occurs with one CPU module.
However, operations for PLC No.2 to 4 will be suspended if PLC No.1, which controls the multiple PLC
system, goes down.
Q25HCPU QX10 QX10 QX10 QX10 QX10 QX10 QX10 QX10 QX10 Q25HCPU Q25HCPU Q25HCPU QX10 QX10 QX10 QX10 QX10 QX10 QX10 QX10 QX10
Q6 1P-A1 POWER Q6 1P-A1 POWER
MOD E MOD E MOD E MOD E
R UN R UN R UN R UN
ER R ER R ER R ER R
U SER U SER U SER U SER
BA T BA T BA T BA T
BOOT BOOT BOOT BOOT
PU LL PU LL
PU LL PU LL PU LL PU LL
U SB U SB U SB U SB
If one CPU module goes down, Possible to continue operations with other CPU
the entire system goes down modules even when one CPU module goes down
2. Standard RAM capacity increased by four times
The capacity of the standard RAM in the Q12HCPU and Q25HCPU has been increased from 32k words to 128k
words.
This enables the standard RAM to use more file registers and local devices.
The following effects are now possible simply by amending the local device settings in the standard RAM for
those users who up until now have had to set the file registers and local devices in memory cards owing to
insufficient memory capacity in the standard RAM.
" Reduction of QCPU scan time *
" Cost reductions (memory cards no longer needed)
Q12HCPU/Q25HCPU up until now Q12HCPU/Q25HCPU after upgrading
Standard RAM
u ƒ ƒ
ƒ b ƒ
N 1 Standard
u ƒ ƒ
ƒ b ƒ
N 1 RAM
R0 Increased by ZR0
t @
ƒ ƒ ƒ
C ƒ
‹ ƒ
Œ ƒ
W X
ƒ ^ƒ t @
ƒ ƒ ƒ
C ƒ
‹ ƒ
Œ ƒ
W X
ƒ ^ƒ
four times
i 32k“_ j i 32k“_ j
to File register
(32k points)
R32767
File register
to (128k points)
ZR131071
*: The remove/restore time for 4k point local devices with eight files has been reduced from 31.5ms to 6ms.
3. Overwriting on the standard ROM made possible with the memory card
(Automatic write to standard ROM)
The automatic write to standard ROM function automatically writes the Program
CPU
file
parameters and sequence programs already stored in the memory card across Parameter
file
to the QCPU's standard ROM. Program
memory
programs.
It is no longer necessary to take a personal computer when installing
programs amended by the design office into the QCPU at a local sites. Local site
Accessing
Accessing machine
Public (Host station)
machine
telephone line
Modem
Modem
Ethernet
(2) Remote passwords are made possible through combinations of the following modules.
" Serial communication modules of function version B (QJ71C24 (-R2))
" Ethernet modules of function version B (QJ71E71 (-B2))
6. Compatible with MELSECNET/H remote I/O networks
(1) It is compatible with a remote I/O system with the use of Q series I/O.
(2) The MELSECNET/H module (QJ71LP21-25, QJ71BR11) of function version B is necessary to structure a
MELSECNET/H remote I/O network.
[Compatible CPU]
Function Relevant QCPU Relevant GX Developer
Multiple PLC system compatibility " QCPUs with function version B or higher Version 6
(products shipped during and after (SW6D5C-GPPW) or
November 2000) higher
Increased standard RAM capacity " QCPUs with function version B or higher.
(Q12HCPU and Q25HCPU only) " QCPUs with serial numbers of 02092 or
Automatic writing in the standard ROM higher (products shipped during and after
Forced ON/OFF of external inputs/outputs September 2000)
Remote password setting
MELSECNET/H remote I/O network compatible
SERIAL 02092 -B
Serial number Function version
(first five digits)
[List of configurable functions]
The MELSEC-Q series modules listed below can be used without modification for multiple PLC systems.
" Input modules, output modules, I/O modules, power modules
" Basic base units, additional base units, addition cables
The intelligent function modules that are restricted for use with multiple PLC systems depending on the function
version are listed below.
" Function version A modules can only be controlled with PLC No.1.
" The modules used with PLC No. 2 to 4 of a multiple PLC system should be those of function version B or
later.
Product Type Description
MELSECNET/H module QJ71BR11 10Mbps communication speed-compatible coaxial bus (control station,
normal station, remote master station)
QJ71LP21-25 10Mbps/25Mbps communication speed-compatible duplex optical bus
(control station, normal station, remote master station)
Ethernet module QJ71E71 Ethernet interface module (10BASE-T, 10BASE5)
QJ71E71-B2 Ethernet interface module (10BASE2)
Serial communication QJ71C24 RS-232, RS-422/485, 1 channel each
module QJ71C24-R2 RS-232, 2 channels
CC-Link module QJ61BT11 Master station, local station
FL-net module QJ71FL71 FL-net (OPCN-2) interface module
Intelligent communication QD51 BASIC program, 2 channels of RS232C
module QD51-R24 BASIC program, 1 channel of RS232C, 1 channel of RS-422
Analog/digital conversion Q64AD Analog input (voltage, current), 4 channels
module Q68ADV Analog input (voltage), 8 channels
Q68ADI Analog input (current), 8 channels
Digital/analog conversion Q62DA Analog output, 2 channels (voltage, current)
module Q64DA Analog output, 4 channels (voltage, current)
Temperature control module Q64TCTT Temperature control module, thermocouple input, transistor output
Q64TCTTBW Temperature control module with disconnection detection function
Thermocouple input, transistor output
Q64TCRT Temperature control module, platinum temperature-measuring resistor
input, transistor output
Q64TCRTBW Temperature control module with disconnection detection function
Platinum temperature-measuring resistor input, transistor output
Positioning module QD75P1 Pulse train open collector output, 1 axis
QD75P2 Pulse train open collector output, 2 axes
QD75P4 Pulse train open collector output, 4 axes
QD75D1 Pulse train differential output, 1 axis
QD75D2 Pulse train differential output, 2 axes
QD75D4 Pulse train differential output, 4 axes
Refer to the data book for details on the possibility of using AnS series I/O modules and special function
modules.
[Manuals]
Manual name Manual shipment type IB/SH No. Type code
QCPU(Q mode) User’s Manual
Sold separately SH-0080038-B 13JL98
(Functions Explanation/Proguram Fundamentals)
QCPU(QMode)/QnACPU Programming Manual
Sold separately SH-0080039-C 13JF58
(Common Instructions)