Technical Data Sheet "Halley E": 40 60 80KVA 3F - 3F

This technical data sheet provides specifications for the Halley E uninterruptible power supply (UPS) system in three power ratings: 40kVA, 60kVA, and 80kVA. The UPS uses a double conversion online topology with efficiencies over 90% and ambient operating temperatures from 0-40°C. Additional details are provided on the rectifier, inverter, bypass, and battery components as well as connectivity, protections, and certifications.

Uploaded by

Florin M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views6 pages

Technical Data Sheet "Halley E": 40 60 80KVA 3F - 3F

This technical data sheet provides specifications for the Halley E uninterruptible power supply (UPS) system in three power ratings: 40kVA, 60kVA, and 80kVA. The UPS uses a double conversion online topology with efficiencies over 90% and ambient operating temperatures from 0-40°C. Additional details are provided on the rectifier, inverter, bypass, and battery components as well as connectivity, protections, and certifications.

Uploaded by

Florin M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

TECHNICAL DATA SHEET “HALLEY E”

40 60 80KVA 3F(in) - 3F(out)


GENERAL INFORMATION
POWER (KVA) 40 60 80
UPS typology ON LINE – Double Conversion
Nominal output power @ P.F. 0,8 (KVA) 40 60 80
Nominal output power @ P.F. 1 (KW) 32 48 64
Efficiency AC ÷ AC (%) >90 >90 >90
Heat dissipation at nominal load and voltage
-KW 3,55 5,33 7,11
-Kcal 3053 4584 6115
UPS ambient temperature (°C) 0 ÷ 40
BATTERY ambient temperature (°C) 0 ÷ +25
UPS storage temperature (°C) -10 ÷ +70
BATTERY storage temperature (°C) -10 ÷ +60
Relative humidity non condensing (%) <95
Altitude (mt) <1000 (Above See Level)
Power derating for altitude > 1000mt According “EN50091-3”
Ventilation FORCED
Requested cooling air volume (mt3/h) 1200 1500 2100
Audible noise level (according EN 50091) <62 db
Protection degree IP 20
Standard battery type lead acid (N° cells) 192 192
Storage time of battery without recharge (@ 25°C) 3 months
EMC Compatibility According to “EN 50091-2”
Paint RAL 5026 Met.
RAL 9006 Met.
Accessibility Front and top access for service
Static load without battery 730 844 958
(Kg/m2)
Input/output cable connection Bottom Side
Transport Base provided for forklift handling
Transport mechanical stress According to “EN50091-1”
Design standard According to “EN50091-1”
Free contact interface On request
Serial communication interface RS232-RS485 (SNMP-Option)
Parallel configuration To increase output power up to
6 UPS or 5+1 redundant

Rev. Descrizione / Description Data / Date Comp. / Comp. Contr. / Check. Appr. / Approv. Lingua / Pag. / di Pag. /
Lang. Pag. of Pag.
A First Issue 16/02/05 F. Beoni E. Simoni E. Simoni E 1 6
B Reviewed some points 15/11/05 P. Conti M. Mancini E. Simoni Cod. / Code
OM461001
RECTIFIER
POWER (KVA) 40 60 80
Nominal Input Voltage (Vac) 380 ÷ 415 +/- 10% (Selectable)
Input Frequency ( Hz) 50 - 60 +/- 5%
Input Power Factor (@ 380Vac) >0,8 >0,8 >0,8
DC Output Voltage Accuracy (%) +/- 1
DC Output Voltage Ripple (With battery connected) (% rms) <1
Total harmonic distortion rejected into the mains (%) <32 <32 <32
Battery Recharging Characteristic IU (DIN 41773)
Temperature Voltage Compensation On Request
Maximum Recharging Current @ nominal load (A) 15 20 20
Rectifier Bridge Type Three Phase Full bridge rectifier
Input protection Fast fuses
Nominal Current Absorbed from Mains
(@ nominal load and Battery in floating) (A) 66 100 133
Maximum Current Absorbed from Mains
(@ nom. load and max. recharging current) (A) 79 116 149

OM461001 REVISION B 2
INVERTER
POWER (KVA) 40 60 80
Inverter Bridge IGBT (High Frequency Comm.)
Nominal Output Power @ P.F. 0,8 (KVA) 40 60 80
Nominal Output Power @ P.F. 1 (KW) 32 48 64
Nominal Output Voltage (Vca) 380 ÷ 415 (Selectable)
Output Voltage Stability (%)
- Static (Balanced Load) +/- 1
- Static (Unbalanced load 100%) +/- 2
- Dynamic (Step Load 0÷100%÷0) +/- 8
- Output Volt. Recovery Time (after step load) Within 40 msec
Phase Angle (°el)
- Balanced Load +/- 1
- 100% Unbalanced Load +/- 2
Output Frequency (Hz) 50 – 60 (Selectable)
Output Frequency Stability (Hz)
- Free Running Quartz Oscillator +/- 0,001
- Inverter Sync. with Mains +/- 2 (Adjustable)
Nominal Output Current (A)
- @ P.F. 0,8 37 87 116
- @ P.F. 1 46 55 93
Overload Capability (%) 125% for 10’,
150% for 1’
200% for 100 msec
Short Circuit Current (A) 92 110 186
Short Circuit Characteristic Elect. short circuit protection, current
limited at 2 times nominal current
Selectivity Within ½ cicle (Fuse gl 20% In)
Output Waveform Sinusoidal
Output Harmonic Distortion (%)
- Linear Load <2
- Non Linear Load <10
Crest Factor 3:1
Max. DC current absorbed from inverter during battery discharge (A) 106,7 160 213,4
(@ 320Vdc and NP)

OM461001 REVISION B 3
BY PASS
Automatic Static By-Pass Electronic Thyristor Switch
Nominal Voltage (Vac) 380 ÷ 415 (Selectable) +/-10%
Nominal Frequency (Hz) 50 – 60 (Selectable) +/-5
Transfer Inverter ÷ Static By-Pass In case of :
-Test inverter
-Inverter failure
-Input inv. Volt. out of limit
-Output inv. volt. out of limit
Retransfer Static By-Pass ÷ Inverter Automatic or Manual (Selectable)
Block on mains after 6 commut. in
2min
Overload Capability -150% Continously
-200% For 1 minute
-2000% For 1 Cicle
Manual By-Pass With electric security and
without interruption

OM461001 REVISION B 4
ALARMS,CONTROLS and SIGNALS

ON THE “SYSTEM CONTROL PANEL” :


- Synoptic diagram showing : power flow,circuit breaker status and alarms
- Battery test indicator
- LCD display
- Keyboard

OPTIONS

1. Free contact remote alarms (PB031 ARC)

2. Remote System control Panel (type AS224)

3. Parallel configuration

4. Battery Temperature Voltage Compensation

OM461001 REVISION B 5
Dimensions:

Weight:
40KVA = 389kg 60KVA = 450kg 80KVA = 511kg

OM461001 REVISION B 6