MR - SLIM With Heat Pump Lineup Catalogue: Inverter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Inverter

Mr.SLIM with Heat pump


Lineup Catalogue
Wrap Yourself in Comfort and Quiet
Eco-conscious Technologies from Japan
LINE-UP
S SERIES
1HP 1.3HP 2HP 2.5HP 3HP 4HP 5HP 6HP
Model Name Page
1-phase 1-phase 1-phase 1-phase 1-phase 1- & 3-phase 1- & 3-phase 1- & 3-phase

SLZ Series
2x2
cassette 2

SEZ Series
Compact
ceiling- 5
concealed

P SERIES
1HP 1.3HP 2HP 2.5HP 3HP 4HP 5HP 6HP
Model Name Page
1-phase 1-phase 1-phase 1-phase 1-phase 1- & 3-phase 1- & 3-phase 1- & 3-phase

PLA Series
4-way
cassette 8

PEAD Series
Ceiling-
concealed 11

PKA Series
Wall-
mounted 13

PCA-KA Series
Ceiling-
suspended 15

PSA Series
Floor- 17
standing

1
SLZ SERIES
SLZ-KF25/35/50/60VA2

Compact, lightweight ceiling cassette units with 4-way air outlets


provide maximum comfort by evenly distributing airflow throughout
the entire room.

New design

The straight-line form introduced has resulted in a beautiful square design.


Its high affinity ensures the ability to blend in seamlessly with any interior.
The indoor unit is an ideal match for office or store use. 600mm
Of course, design matched 2×2 (600mm*600mm) ceiling construction 600mm
specifications.

The height above ceiling of 245mm

The height above ceiling of 245mm enables fitting into


narrow ceiling space. Installation is simple, even when
the ceiling spaces are narrow to make the ceilings higher.
Of course, in addition to our products, replacing competi-
tors’ product is simplified too.
245mm

Quietness
The sound level has been reduced by SLZ-KF Cooling
2-4dB thanks to the introduction of a 3D SPL [Lo]
32dB(A)
turbo fan, for quieter and more comfortable Previous model New model
air conditioning. 30dB(A)
29dB(A) 29dB(A)

27dB(A)

25dB(A) 25dB(A)

2.5kW 3.5kW 5.0kW 6.0kW

2
Easy installation

Temporary hanging hook


The structure of the panel has been revised and is now equipped
with a temporary hanging hook. This has improved work efficiency
during temporary panel installation.

■ Corner panel ■ Control box cover


No need to remove screws
Installation is possible without removing the screws for control box
simply loosen them. This eliminates the risk of losing screws.

for S & P SERIES


Detects number of people
Room occupancy energy-saving mode Room occupancy energy save mode

The 3D i-see Sensor detects the number of people in the room. It


then calculates the occupancy rate based on the maximum number
of people in the room up to that point in time in order to save air- 1C°
conditioning power. When the occupancy rate is approximately power
30%, air-conditioning power equivalent to 1°C during both cooling savings
and heating operation is saved. The temperature is controlled
according to the number of people. No occupancy energy save mode

No occupancy energy-saving mode


When 3D i-see Sensor detects that no one is in the room, the system 2C°
is switched to a pre-set power-saving mode. If the room remains un- power
occupied for more than 60min, air-conditioning power equivalent to savings
2°C during both cooling and heating operation is saved. This contrib-
utes to preventing waste in terms of heating and cooling.
No occupancy Auto-Off mode

No occupancy Auto-OFF mode


When the room remains unoccupied for a pre-set period of time, the
Auto-Off
air conditioner turns off automatically, thereby providing even great-
er power savings. The time until operation is stopped can be set in
intervals of 10min, ranging from 60 to 180 min.

Detects people’s position


*PAR-32MAA is required for each setting

Direct /Indirect settings* Seasonal airflow*


Some people do not like the feel of wind, some want <When cooling> <When heating>
to be warm from head to toe. People’s likes and dis- Saves energy while keeping a comfort- The air conditioning unit automatically
likes vary. With the 3D i-see Sensor, it is possible to able effective temperature by automati- switches between circulator and heating.
choose to block or not block to the wind for each cally switching between ventilation and Wasted heat that accumulates near the
vane. cooling. When a pre-set temperature ceiling is reused via circulation. When a
is reached, the air conditioning unit pre-set temperature is reached the air con-
switches to swing fan operation to ditioner switches from heating to circulator
maintain the effective temperature. and blows air in the horizontal direction. It
This clever function contributes to pushes down the warm air that has gath-
keeping a comfortable coolness. ered near the ceiling to people’s height,
thereby providing smart heating.

Cooling Heating

*PAR-32MAA or PAR-SL100A-E is required for each setting.

*PAR-32MAA is required for each setting.

3
SLZ-KF SERIES
Indoor Unit Outdoor Unit Remote Controller

SLZ-KF25/35/50/60VA2
SUZ-KA25/35VA6
Enclosed in
Panel SLP-2FALM/SLP-2FALME

With Signal With 3D i-see With Wireless


Panel Receiver Sensor Remote Controller
SLP-2FA
SLP-2FAL
SLP-2FAE
SLP-2FALE
SLP-2FALM *optional *optional
SLP-2FALME SUZ-KA50/60VA6

R410A Heatpump INV Std 2by2 Cassette SLZ Specification Sheet


Models SLZ-KF25VA2 SLZ-KF35VA2 SLZ-KF50VA2 SLZ-KF60VA2
Cooling Capacity (Min-Max) kW 2.6 (1.5-3.2) 3.5 (1.4-3.9) 4.6 (2.3-5.2) 5.6 (2.3-6.5)
Capacity BTU/h 8,800 11,900 15,600 19,100
Total Input kW 0.684 0.972 1.394 1.767
EER W/W 3.80 3.60 3.30 3.17
Heating Capacity (Min-Max) kW 3.2 (1.3-4.2) 4.0 (1.7-5.0) 5.0 (1.7-6.0) 6.4 (2.5-7.4)
Capacity BTU/h 10,900 13,600 17,000 21,800
Total Input kW 0.886 1.108 1.558 2.278
COP W/W 3.61 3.61 3.21 2.81
Indoor Model name SLZ-KF25VA2 SLZ-KF35VA2 SLZ-KF50VA2 SLZ-KF60VA2
Unit Power supply 1ph 230V 50Hz
External finish Munsell 1.0Y 9.2/0.2
CMM 6.5-7.5-8.5 6.5-8.0-9.5 7.0-9.0-11.5 7.5-11.5-13.0
Airflow (low-med2-med1-high)
CFM 230-265-300 230-283-335 247-318-406 265-406-459
External static pressure Pa 0 (direct blow)
Opearation control and thermostat Remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 25-28-31 25-30-34 27-34-39 32-40-43
Unit drain pipe (outer diameter) mm 32
W mm 570 (625)
Dimensions (panel) D mm 570 (625)
H mm 245 (10)
Weight (panel) kg 15 (3)
Outdoor Model name SUZ-KA25VA6 SUZ-KA35VA6 SUZ-KA50VA6 SUZ-KA60VA6
Unit Power supply 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 32.6 36.3 44.6 40.9
Cooling
CFM 1151 1281 1574 1444
Airflow
CMM 34.7 34.8 44.6 49.2
Heating
CFM 1225 1228 1574 1737
Cooling dB (A) 47 49 52 55
Noise level
Heating dB (A) 48 50 52 55
W mm 800 800 840 840
Dimensions D mm 285 285 330 330
H mm 550 550 880 880
Weight kg 30 35 54 50
Max. height difference m 12 12 30 30
Max. piping length m 20 20 30 30
Pipe size (outer diameter) mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88
Chargeless piping length m 7 7 7 7

Guaranteed Opearating Range Cooling* -10~+46 -10~+46 -15~+46 -15~+46


[Outdoor] Heating -10~+24 -10~+24 -10~+24 -10~+24

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

4
SEZ SERIES SEZ-KD25 -71VAQ/VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this A Air inlet
ceiling-concealed indoor unit. The rest of the unit is conveniently B Air outlet
C Access door
hidden in the ceiling cavity, essentially leaving the ceiling and walls D Ceiling surface
free of bulky looking devices and maintaining a high-class interior E Canvas duct
décor. The compact units require minimal space and can be installed F Air filter
G Inlet grille
in buildings with lowered ceilings, where exposed units were the
rule in the past.
Width reduced by

Dimension Comparison 110mm


1100 700 990

Height
200 reduced by
270
70mm

SEZ-KA35VA SEZ-KD35VA

Increased Selection of Fan Speeds and


Static Pressure Levels We’ve lowered the minimum static pressure level, resulting
in less room noise when the optimum static pressure is
DC fan motor settings have been increased to accommodate more selected.
application needs. Three fan speed settings (Low, Medium and
High) and four static pressure levels (5, 15, 35 and 50Pa) are now
available.

External Static Pressure SPL (Low Fan Mode)

SEZ-KC25VA 5 Pa SEZ-KA SEZ-KD

SEZ-KA35-71VA 30/50 Pa External Static Pressure 30 Pa 15 Pa

35 30dB 23dB

50 31dB 30dB

SEZ-KD25-71VA 5/15/35/50 Pa 60 32dB 30dB

71 32dB 30dB
Four Levels Available for All Models
Maximum noise
reduced by 7dB

5
SEZ-KD SERIES
Indoor Unit Outdoor Unit Remote Controller

SUZ-KA25/35VA6
Enclosed in
SEZ-KD25/35/50/60/71VAL (Wireless Remote Controller is enclosed)
SEZ-KD25/35/50/60/71VAL

*optional *optional
SUZ-KA50/60/71VA6

R410A Heatpump INV Std Compact ceiling concealed SEZ Specification Sheet
Models SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Cooling Capacity (Min-Max) kW 2.5 (1.5-3.2) 3.5 (1.4-3.9) 5.1 (2.3-5.6) 5.6 (2.3-6.3) 7.1 (2.8-8.3)
Capacity BTU/h 8,500 11,900 17,400 19,100 24,000
Total Input kW 0.730 1.010 1.578 1.740 2.210
EER W/W 3.42 3.47 3.23 3.22 3.21
Heating Capacity (Min-Max) kW 2.9 (1.3-4.5) 4.2 (1.7-5.0) 6.4 (1.7-7.2) 7.4 (2.5-8.0) 8.1 (2.6-10.4)
Capacity BTU/h 9,800 14,300 21,800 25,200 27,600
Total Input kW 0.803 1.130 1.800 2.200 2.268
COP W/W 3.61 3.72 3.56 3.36 3.57
Indoor Model name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Unit Power supply 1ph 230V 50Hz
External finish Galvanized sheets
CMM 5.5-7.0-9.0 7.0-9.0-11.0 10.0-12.5-15.0 12.0-15.0-18.0 12.0-16.0-20.0
Airflow (low-med2-med1-high)
CFM 194-247-318 247-318-388 353-441-530 424-530-636 424-565-706
External static pressure Pa 5 / 15 / 35 / 50
Opearation control and thermostat Remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 22-25-29 23-28-33 29-33-36 29-33-37 29-34-39
Unit drain pipe (outer diameter) mm 32
W mm 790 990 990 1190 1190
Dimensions (panel) D mm 700 700 700 700 700
H mm 200 200 200 200 200
Weight (panel) kg 18 21 23 27 27
Outdoor Model name SUZ-KA25VA6 SUZ-KA35VA6 SUZ-KA50VA6 SUZ-KA60VA6 SUZ-KA71VA6
Unit Power supply 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 32.6 36.3 44.6 40.9 50.1
Cooling
CFM 1151 1281 1574 1444 1769
Airflow
CMM 34.7 34.8 44.6 49.2 48.2
Heating
CFM 1225 1228 1574 1737 1701
Cooling dB (A) 47 49 52 55 55
Noise level
Heating dB (A) 48 50 52 55 55
W mm 800 800 840 840 840
Dimensions D mm 285 285 330 330 330
H mm 550 550 880 880 880
Weight kg 30 35 54 50 53
Max. height difference m 12 12 30 30 30
Max. piping length m 20 20 30 30 30
Pipe size (outer diameter) mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88
Chargeless piping length m 7 7 7 7 7

Guaranteed Opearating Range Cooling* -10~+46 -10~+46 -10~+46 -15~+46 -15~+46


[Outdoor] Heating -10~+24 -10~+24 -10~+24 -10~+24 -10~+24

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

6
7
PLA-RP50/71/100/125/140EA

PLA SERIES
A complete line-up including deluxe units that offer added energy savings. The incorpora-
tion of wide air-outlet and the “3D i-see Sensor” enhances airflow distribution control,
achieving an enhanced level of comfort throughout the room. The synergy of higher
energy efficiency and more comfortable room environment results in the utmost user sat-
isfaction.

Automatic Grille Lowering Function (PLP-6EAJ)


An automatic grille lowering function is available for easy filter maintenance. Special wired and wireless
remote controllers can be used to lower the intake grille for maintenance.

1.2m

1.6m

2.0m

2.4m

Grille Elevation Remote Controller Wired Remote Controller Wireless Remote Controller 2.8m
(comes with the automatic elevation panel)
3.2m

3.6m

4.0m

Maximum 4m
Automatic elevation

Easy Installation

Electrical box wiring Increased space for plumbing work

After reviewing the power supply terminal position in the electrical The top and bottom positions of the liquid and gas pipes have been re-
box, the structure was redesigned to improve connectivity. This has versed to allow the gas pipe work, which requires more effort, to be
made previously complex wiring work easier. completed first. Further, through structural innovations related to the
space around the pipes, the area where the spanner can be moved
■ Previous model (B Series) ■ New model (E Series)
has been increased, thus improving liquid pipe work and enabling it to
be completed smoothly.
■ Previous model (B Series) ■ New model (E Series)

50° 70°

Temporary hanging hook No need to remove screws Lightweight decorative panel

The structure of the panel has been revised Installation is possible without removing the After reviewing the structure and materials,
and is now equipped with a temporary hang- screws for the corner panel and the control weight has been reduced approximately 20%
ing hook. This has improved work efficiency box, simply loosen them. This lowers the risk compared to the previous model, reducing the
during panel installation. of losing screws. burden of installation.
■ Corner panel ■ Control box cover

8
for S & P SERIES
Detects number of people
3D i-see Sensor detects the number of people in the room and sets Detects number
the air-conditioning power accordingly. This makes automatic pow- of people
er-saving operation possible in places where the number of people
entering and exiting is large. Additionally, when the area is continu-
ously unoccupied, the system switches to a more enhanced pow-
er-saving mode. Depending on the setting, it will save additional ca- Detects people’s
pacity or stop operation altogether. position

Detects people’s position


Once the position of a person is detected, the duct angle of the vane
is automatically adjusted in that direction. Each vane can be
independently set to “block wind” or “not block wind” according to Detects position
360°
and number of people
taste. Detection
Detects floor
temperature 2.7m
7.2m
8 sensors
1.1m

12m
8 7 6 4 53 2 1 1 2 3 4 5 6 7 8

Floor surface *In case of a 2.7m ceiling

Detects number of people


Room occupancy energy-saving mode Room occupancy energy save mode

The 3D i-see Sensor detects the number of people in the room. It


then calculates the occupancy rate based on the maximum number
of people in the room up to that point in time in order to save air- 1C°
conditioning power. When the occupancy rate is approximately power
30%, air-conditioning power equivalent to 1°C during both cooling savings
and heating operation is saved. The temperature is controlled
according to the number of people. No occupancy energy save mode

No occupancy energy-saving mode


When 3D i-see Sensor detects that no one is in the room, the system 2C°
is switched to a pre-set power-saving mode. If the room remains un- power
occupied for more than 60min, air-conditioning power equivalent to savings
2°C during both cooling and heating operation is saved. This contrib-
utes to preventing waste in terms of heating and cooling.
No occupancy Auto-Off mode

No occupancy Auto-OFF mode


When the room remains unoccupied for a pre-set period of time, the
Auto-Off
air conditioner turns off automatically, thereby providing even great-
er power savings. The time until operation is stopped can be set in
intervals of 10min, ranging from 60 to 180 min.

*PAR-32MAA is required for each setting

Detects people’s position


Direct /Indirect settings* Seasonal airflow*
Some people do not like the feel of wind, some want <When cooling> <When heating>
to be warm from head to toe. People’s likes and dis- Saves energy while keeping a comfort- The air conditioning unit automatically
likes vary. With the 3D i-see Sensor, it is possible to able effective temperature by automati- switches between circulator and heating.
choose to block or not block to the wind for each cally switching between ventilation and Wasted heat that accumulates near the
vane. cooling. When a pre-set temperature ceiling is reused via circulation. When a
is reached, the air conditioning unit pre-set temperature is reached the air con-
switches to swing fan operation to ditioner switches from heating to circulator
maintain the effective temperature. and blows air in the horizontal direction. It
This clever function contributes to pushes down the warm air that has gath-
keeping a comfortable coolness. ered near the ceiling to people’s height,
thereby providing smart heating.

Cooling Heating

*PAR-32MAA or PAR-SL100A-E is required for each setting.

*PAR-32MAA is required for each setting.

9
PLA-RP SERIES
Indoor Unit Outdoor Unit

PLA-RP50/71/100/125/140EA
Panel
With With With With
Panel Signal 3D i-see Wireless Auto
Receiver Sensor Remote Elevation
Controller
PLP-6EA
PLP-6EAL SUZ-KA50/71 PUHZ-P100 PUHZ-P125/140
PLP-6EAE
PLP-6EALE
PLP-6EAJ
PLP-6EAJE
PLP-6EALM
PLP-6EALME

Remote Controller

Optional Optional ✽ Enclosed in PLP-6EALM/PLP-6EALME

R410A Heatpump INV Std Ceiling Cassette PLA Specification Sheet


Models PLA-RP50EA-PA PLA-RP71EA-PA PLA-RP100EA-PA PLA-RP125EA-PA PLA-RP140EA-PA
Cooling Capacity (Min-Max) kW 5.5 (2.3-5.6) 7.1 (2.8-8.1) 9.4 (3.7-10.6) 12.1 (5.6-13.0) 13.6 (5.8-14.1)
Capacity BTU/h 18,700 24,000 32,000 41,200 46,400
Total Input kW 1.61 2.10 3.18 4.10 5.41
EER W/W 3.41 3.38 2.95 2.95 2.51
Heating Capacity (Min-Max) kW 5.8 (1.7-7.2) 8.0 (2.6-10.2) 11.2 (2.8-12.5) 13.5 (4.8-15.0) 15.0 (4.9-15.8)
Capacity BTU/h 19,700 27,200 38,200 46,000 51,100
Total Input kW 1.69 2.24 3.26 3.84 4.67
COP W/W 3.43 3.57 3.43 3.51 3.21
Indoor Model name PLA-RP50EA-PA PLA-RP71EA-PA PLA-RP100EA-PA PLA-RP125EA-PA PLA-RP140EA-PA
Unit Power supply 1ph 220-240V 50Hz / 1ph 220-230V 60Hz
External finish Munsell 1.0Y 9.2/0.2
CMM 14-16-17-18 16-17-19-21 19-23-26-29 21-25-28-31 24-26-29-32
Airflow (low-med2-med1-high)
CFM 495-565-600-635 565-600-670-740 670-810-920-1025 740-885-990-1095 850-920-1025-1130
External static pressure Pa 0 (direct blow)
Opearation control and thermostat Remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 27-29-31-32 28-30-32-34 31-34-37-40 32-37-41-44 36-39-42-44
Unit drain pipe (outer diameter) mm 32
W mm 840 (950)
Dimensions (panel) D mm 840 (950)
H mm 258 (40) 298 (40)
Weight (panel) kg 19 (5) 21 (5) 24 (5) 27 (5)
Outdoor Model name SUZ-KA50VA6 SUZ-KA71VA6 PUHZ-P100VKA PUHZ-P100YKA PUHZ-P125VKA PUHZ-P125YKA PUHZ-P140VKA PUHZ-P140YKA
Unit Power supply 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 44.6 50.1 79 79 86 86 86 86
Cooling
CFM 1574 1769 2789 2789 3036 3036 3036 3036
Airflow
CMM 44.6 48.2 79 79 92 92 92 92
Heating
CFM 1574 1701 2789 2789 3248 3248 3248 3248
Cooling dB (A) 52 55 51 51 54 54 56 56
Noise level
Heating dB (A) 52 55 54 54 56 56 57 57
W mm 840 840 1050 1050 1050 1050 1050 1050
Dimensions D mm 330 330 330 330 330 330 330 330
H mm 880 880 981 981 981 981 981 981
Weight kg 54 53 76 78 84 85 84 85
Max. height difference m 30 30 30 30 30 30 30 30
Max. piping length m 30 30 50 50 50 50 50 50
Pipe size (outer diameter) mm 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Chargeless piping length m 7 7 30 30 30 30 30 30

Guaranteed Opearating Range Cooling* -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -10~+24 -10~+24 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

10
PEAD-RP50/71/100/125/140JA(L)Q

PEAD SERIES
The thin, ceiling-concealed indoor units of this series are the perfect answer for the air
conditioning needs of buildings with minimum ceiling installation space and wide-
ranging external static pressure. Energy-saving efficiency has been improved, reduc-
ing electricity consumption and contributing to a further reduction in operating cost.

Compact Indoor Units


The height of the models from 35–140 has been unified to 250mm. Compared to the previous PEAD-RP EA model, the height has been reduced
by as much as 75mm (models 100–140), making installation in low ceilings with minimal clearance space possible.

Reduction of

250mm 75mm
(models 100 –140)
compared to PEAD-EA

PEAD-RP JAQ

External Static Pressure


External static pressure conversion can be set up to five stages. Capable of being set to a maximum of 150Pa, units are applicable to a wide range
of building types.

■ External static pressure setting


Series 35 50 60 71 100 125 140
PEAD-RP EA 30/70Pa 70/130 (with optional motor) Pa
PEAD-RP GA – – 10/50/70Pa – –
PEAD-RP JA 35/50/70/100/150Pa

11
PEAD-RP SERIES
Indoor Unit Outdoor Unit

SUZ-KA50/71 PUHZ-P100 PUHZ-P125/140

PEAD-RP50/71/100/125/140

Remote Controller

Optional Optional Optional

R410A Heatpump INV Std Ceiling Concealed PEAD Specification Sheet


Models PEAD-RP50JALQ-PA PEAD-RP71JALQ-PA PEAD-RP100JALQ-PA PEAD-RP125JALQ-PA PEAD-RP140JALQ-PA
Cooling Capacity (Min-Max) kW 4.9 (2.3-5.6) 7.1 (2.8-8.1) 9.4 (3.7-10.6) 12.1 (5.6-13.0) 13.6 (5.8-14.1)
Capacity BTU/h 16,700 24,000 32,000 41,200 46,400
Total Input kW 1.46 2.06 2.96 4.14 5.19
EER W/W 3.36 3.45 3.18 2.92 2.62
Heating Capacity (Min-Max) kW 5.9 (1.7-7.2) 8.0 (2.6-10.2) 11.2 (2.8-12.5) 13.5 (4.8-15.0) 15.0 (4.9-15.8)
Capacity BTU/h 20,100 27,200 38,200 46,000 51,100
Total Input kW 1.62 2.04 2.94 3.73 4.27
COP W/W 3.64 3.92 3.81 3.62 3.51
Indoor Model name PEAD-RP50JALQ PEAD-RP71JALQ PEAD-RP100JALQ PEAD-RP125JALQ PEAD-RP140JALQ
Unit Power supply 1ph 220-240V 50Hz
External finish Galvanized steel plate
CMM 12.0-14.5-17.0 17.5-21.0-25.0 24.0-29.0-34.0 29.5-35.5-42.0 32.0-39.0-46.0
Airflow (low-med2-med1-high)
CFM 424-512-600 618-742-883 848-1024-1200 1042-1254-1483 1130-1377-1624
External static pressure Pa 35/50/70/100/150
Opearation control and thermostat Built in
Noise level (low-med2-med1-high) dB (A) 26-31-35 26-30-34 29-34-38 33-36-40 34-38-43
Unit drain pipe (outer diameter) mm 32
W mm 900 1100 1400 1600
Dimensions (panel) D mm 732
H mm 250
Weight (panel) kg 26 29 38 39 43
Outdoor Model name SUZ-KA50VA6 SUZ-KA71VA6 PUHZ-P100VKA PUHZ-P100YKA PUHZ-P125VKA PUHZ-P125YKA PUHZ-P140VKA PUHZ-P140YKA
Unit Power supply 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 44.6 50.1 79 79 86 86 86 86
Cooling
CFM 1574 1769 2789 2789 3036 3036 3036 3036
Airflow
CMM 44.6 48.2 79 79 92 92 92 92
Heating
CFM 1574 1701 2789 2789 3248 3248 3248 3248
Cooling dB (A) 52 55 51 51 54 54 56 56
Noise level
Heating dB (A) 52 55 54 54 56 56 57 57
W mm 840 840 1050 1050 1050 1050 1050 1050
Dimensions D mm 330 330 330 330 330 330 330 330
H mm 880 880 981 981 981 981 981 981
Weight kg 54 53 76 78 84 85 84 85
Max. height difference m 30 30 30 30 30 30 30 30
Max. piping length m 30 30 50 50 50 50 50 50
Pipe size (outer diameter) mm 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Chargeless piping length m 7 7 30 30 30 30 30 30

Guaranteed Opearating Range Cooling* -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -10~+24 -10~+24 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

12
PKA SERIES PKA-RP100KAL

The compact, wall-mounted indoor units offer the convenience of simple installation,
and a large product line-up ensures a best-match solution. Designed for highly effi-
cient energy savings, the PKA Series is the answer to your air conditioning needs.

Flat Panel & Pure White Finish


A flat panel layout has been adopted for all models. Pursuing a design that harmonizes with virtually any interior, the unit colour has been changed
from white to pure white.
Flat panel is
easy to clean!

PKA-RP KAL

Compact Indoor Units


Indoor unit width has been reduced. Units take up much less space, greatly increasing installation possibilities.

13
PKA-RP SERIES
Indoor Unit Outdoor Unit

PKA-RP100KAL
PUHZ-P100

Remote Controller

Optional (✽) Optional (✽)

(✽) PAC-SH29TC-E is required (optional)

R410A Heatpump INV Std Wall Mounted PKA Specification Sheet


Models PKA-RP100KAL
Cooling Capacity (Min-Max) kW 9.4 (3.7-10.6)
Capacity BTU/h 32,000
Total Input kW 3.12
EER W/W 3.01
Heating Capacity (Min-Max) kW 11.2 (2.8-12.5)
Capacity BTU/h 38,200
Total Input kW 3.48
COP W/W 3.21
Indoor Model name PKA-RP100KAL
Unit Power supply 1ph 230V 50Hz
External finish Munsell 1.0Y 9.2/0.2
CMM 20-23-26
Airflow (low-med2-med1-high)
CFM 706-812-918
External static pressure Pa 0 (direct blow)
Opearation control and thermostat Wireless remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 41-45-49
Unit drain pipe (outer diameter) mm 22
W mm 1170
Dimensions (panel) D mm 295
H mm 365
Weight (panel) kg 21
Outdoor Model name PUHZ-P100VKA PUHZ-P100YKA
Unit Power supply 1ph 230V 50Hz 3ph 400V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 79 79
Cooling
CFM 2789 2789
Airflow
CMM 79 79
Heating
CFM 2789 2789
Cooling dB (A) 51 51
Noise level
Heating dB (A) 54 54
W mm 1050 1050
Dimensions D mm 330 330
H mm 981 981
Weight kg 76 78
Max. height difference m 30 30
Max. piping length m 50 50
Pipe size (outer diameter) mm 9.52 / 15.88 9.52 / 15.88
Chargeless piping length m 30 30

Guaranteed Opearating Range Cooling* -15~+46 -15~+46


[Outdoor] Heating -15~+21 -15~+21

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

14
PCA SERIES PCA-RP35/50/60/71/100/125/140KAQ

A stylish new indoor unit design and airflow settings for both high- and low-ceiling
interiors expand installation possibilities. Together with exceptional energy-saving
performance, these units are the solution to diversified air conditioning needs.

Stylish Indoor Unit Design


A stylish square-like design is adopted for the indoor units of all models. As a result,
the units blend in better with the ceiling.

PCA-KAQ

Equipped with Automatic Air-speed Adjustment Equipped with High- /Low-ceiling Modes
In addition to the conventional 4-speed setting, units are now equipped Units are equipped with high- and low-ceiling operation modes that
with an automatic air-speed adjustment mode. This setting automati- make it possible to switch the airflow volume to match room height.
cally adjusts the air-speed to conditions that match the room environ- The ability to choose the optimum airflow volume makes it possible
ment. At the start of heating/cooling operation, the airflow is set to to optimize the breezy sensation felt throughout the room.
high-speed to quickly heat/cool the room. When the room tempera-
ture reaches the desired setting, the airflow speed is decreased auto- High Standard Low
Capacity
matically for stable comfortable heating/cooling operation. ceiling ceiling ceiling
35 3.5m 2.7m 2.5m
50 3.5m 2.7m 2.5m
Strong Gentle 60 3.5m 2.7m 2.5m
71 3.5m 2.7m 2.5m
100 4.2m 3.0m 2.6m
125 4.2m 3.0m 2.6m
Start of cooling/heating… After room temperature is stabilized… 140 4.2m 3.0m 2.6m

15
PCA-RP SERIES
Indoor Unit Outdoor Unit Remote Controller

SUZ-KA35 SUZ-KA50/60/71 PUHZ-P100 PUHZ-P125/140 Optional Optional Optional


PCA-RP35/50/60/71/100/125/140KAQ

R410A Heatpump INV Std Ceiling suspended PCA Specification Sheet


Models PCA-RP35KAQ PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ
Cooling Capacity (Min-Max) kW 3.6 (1.4-3.9) 5.0 (2.3-5.6) 5.7 (2.3-6.3) 7.1 (2.8-8.1) 9.4 (3.7-10.6) 12.1 (5.6-13.0) 13.6 (5.8-14.1)
Capacity BTU/h 12,200 17,000 19,400 24,000 32,000 41,200 46,400
Total Input kW 1.05 1.55 1.72 2.06 3.05 4.24 5.64
EER W/W 3.43 3.23 3.31 3.45 3.08 2.85 2.41
Heating Capacity (Min-Max) kW 4.1 (1.7-5.0) 5.5 (1.7-6.6) 6.9 (2.5-8.0) 7.9 (2.6-10.2) 11.2 (2.8-12.5) 13.5 (4.8-15.0) 15.0 (4.9-15.8)
Capacity BTU/h 13,900 18,700 23,500 26,900 38,200 46,000 51,100
Total Input kW 1.13 1.52 1.91 2.18 3.37 4.06 4.47
COP W/W 3.63 3.62 3.61 3.62 3.32 3.32 3.35
Indoor Model name PCA-RP35KAQ PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ
Unit Power supply 1ph 230V 50Hz
External finish Munsell 6.4Y 8.9/0.4
CMM 10-11-12-14 10-11-13-15 15-16-17-19 16-17-18-20 22-24-26-28 23-25-27-29 24-26-29-32
Airflow (low-med2-med1-high)
CFM 353-388-424-494 353-388-459-530 530-565-600-671 565-600-636-706 777-848-918-989 812-883-954-1024 848-918-1024-1130
External static pressure Pa 0 (direct blow)
Opearation control and thermostat Remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 31-33-36-39 32-34-37-40 33-35-37-40 35-37-39-41 37-39-41-43 39-41-43-45 41-43-45-48
Unit drain pipe (outer diameter) mm 26
W mm 960 1280 1600
Dimensions (panel) D mm 680 680 680
H mm 230 230 230
Weight (panel) kg 24 25 32 32 36 38 39
Outdoor Model name SUZ-KA35VA6 SUZ-KA50VA6 SUZ-KA60VA6 SUZ-KA71VA6 PUHZ-P100VKA PUHZ-P100YKA PUHZ-P125VKA PUHZ-P125YKA PUHZ-P140VKA PUHZ-P140YKA
Unit Power supply 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 36.3 44.6 40.9 50.1 79 79 86 86 86 86
Cooling
CFM 1281 1574 1444 1769 2789 2789 3036 3036 3036 3036
Airflow
CMM 34.8 44.6 49.2 48.2 79 79 92 92 92 92
Heating
CFM 1228 1574 1737 1701 2789 2789 3248 3248 3248 3248
Cooling dB (A) 49 52 55 55 51 51 54 54 56 56
Noise level
Heating dB (A) 50 52 55 55 54 54 56 56 57 57
W mm 800 840 840 840 1050 1050 1050 1050 1050 1050
Dimensions D mm 285 330 330 330 330 330 330 330 330 330
H mm 550 880 880 880 981 981 981 981 981 981
Weight kg 35 54 50 53 76 78 84 85 84 85
Max. height difference m 12 30 30 30 30 30 30 30 30 30
Max. piping length m 20 30 30 30 50 50 50 50 50 50
Pipe size (outer diameter) mm 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Chargeless piping length m 7 7 7 7 30 30 30 30 30 30

Guaranteed Opearating Range Cooling* -10~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -10~+24 -10~+24 -10~+24 -10~+24 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

16
PSA SERIES
Installation of this floor-standing series is easy and quick.
An excellent choice when there is a sudden need for an air conditioner to be installed.

Quick and Easy Installation, Space-saving and


Design That Compliments Any Interior
The floor-standing indoor unit is mounted on the floor, enabling quick installation. Its compact body requires only minimal space.

4-way pipe work connections enable greater freedom


in installation
Remarkable freedom in choosing installation sites is allowed
by providing piping connection to the indoor unit in four
places: left side, back, from underneath and on the right side
of the unit. Even installation in the corner of a room is easy.
1,900mm

Back
Left side

Right side

Underneath

600mm 360mm

Built-in Remote Controller


Easy Operation with Built-in PAR-21MAA Remote Controller
Icon, letter and number visibility are improved with the adoption of Main Functions
a dot liquid-crystal display (LCD), and operation management func-
tions have been increased. • Multi-language Display
• Limited Temperature Range Setting
• Auto-off Timer
• Operation Lock
• Weekly Timer

17
PSA-RP SERIES
Indoor Unit Outdoor Unit Remote Controller

PUHZ-P100 PUHZ-P125/140 Built-in

PSA-RP100/125/140KA

R410A Heatpump INV Std Floor Standing PSA Specification Sheet


Models PSA-RP100KA PSA-RP125KA PSA-RP140KA
Cooling Capacity (Min-Max) kW 9.4 (3.7-10.6) 12.1 (5.6-13.0) 13.6 (5.8-13.7)
Capacity BTU/h 32,000 41,200 46,400
Total Input kW 3.12 5.02 6.38
EER W/W 3.01 2.41 2.13
Heating Capacity (Min-Max) kW 11.2 (2.8-12.5) 13.5 (4.8-15.0) 15.0 (4.9-15.8)
Capacity BTU/h 38,200 46,000 51,100
Total Input kW 3.28 4.80 4.82
COP W/W 3.41 2.81 3.11
Indoor Model name PSA-RP100KA PSA-RP125KA PSA-RP140KA
Unit Power supply 1ph 230V 50Hz
External finish Munsell 0.7Y 8.59/0.97
CMM 25-28-30 25-28-31 25-28-31
Airflow (low-med2-med1-high)
CFM 883-989-1059 883-989-1095 883-989-1095
External static pressure Pa 0 (direct blow)
Opearation control and thermostat Remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 45-49-51 45-49-51 45-49-51
Unit drain pipe (outer diameter) mm 20
W mm 600
Dimensions (panel) D mm 360
H mm 1900
Weight (panel) kg 46 46 48
Outdoor Model name PUHZ-P100VKA PUHZ-P100YKA PUHZ-P125VKA PUHZ-P125YKA PUHZ-P140VKA PUHZ-P140YKA
Unit Power supply 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz 1ph 230V 50Hz 3ph 400V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 79 79 86 86 86 86
Cooling
CFM 2789 2789 3036 3036 3036 3036
Airflow
CMM 79 79 92 92 92 92
Heating
CFM 2789 2789 3248 3248 3248 3248
Cooling dB (A) 51 51 54 54 56 56
Noise level
Heating dB (A) 54 54 56 56 57 57
W mm 1050 1050 1050 1050 1050 1050
Dimensions D mm 330 330 330 330 330 330
H mm 981 981 981 981 981 981
Weight kg 76 78 84 85 84 85
Max. height difference m 30 30 30 30 30 30
Max. piping length m 50 50 50 50 50 50
Pipe size (outer diameter) mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Chargeless piping length m 30 30 30 30 30 30

Guaranteed Opearating Range Cooling* -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21

・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.

18
NOTICE
■ Do not install indoor units in areas (e.g. mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ Our air-conditioning equipments and heat pumps contain a fluorinated greenhouse gas, R410A (GWP: 2088) or
R32 (GWP: 675). *These GWP values are based on Regulation (EU) No.517/2014 from IPCC 4th edition. In case of
Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP: 1975), R32 (GWP: 550)
■ When installing or relocating or servicing our air-conditioning equipment, use only the specified refrigerant (R410A or R32)
to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Eco Changes is the Mitsubishi Electric Group’s environmental statement,


and expresses the Group’s stance on environmental management.
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.

New publication, effective Mar. 2019.


1805415-1-29<IP> Specifications are subject to change without notice.