MR - SLIM With Heat Pump Lineup Catalogue: Inverter
MR - SLIM With Heat Pump Lineup Catalogue: Inverter
MR - SLIM With Heat Pump Lineup Catalogue: Inverter
SLZ Series
2x2
cassette 2
SEZ Series
Compact
ceiling- 5
concealed
P SERIES
1HP 1.3HP 2HP 2.5HP 3HP 4HP 5HP 6HP
Model Name Page
1-phase 1-phase 1-phase 1-phase 1-phase 1- & 3-phase 1- & 3-phase 1- & 3-phase
PLA Series
4-way
cassette 8
PEAD Series
Ceiling-
concealed 11
PKA Series
Wall-
mounted 13
PCA-KA Series
Ceiling-
suspended 15
PSA Series
Floor- 17
standing
1
SLZ SERIES
SLZ-KF25/35/50/60VA2
New design
Quietness
The sound level has been reduced by SLZ-KF Cooling
2-4dB thanks to the introduction of a 3D SPL [Lo]
32dB(A)
turbo fan, for quieter and more comfortable Previous model New model
air conditioning. 30dB(A)
29dB(A) 29dB(A)
27dB(A)
25dB(A) 25dB(A)
2
Easy installation
Cooling Heating
3
SLZ-KF SERIES
Indoor Unit Outdoor Unit Remote Controller
SLZ-KF25/35/50/60VA2
SUZ-KA25/35VA6
Enclosed in
Panel SLP-2FALM/SLP-2FALME
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
4
SEZ SERIES SEZ-KD25 -71VAQ/VAL
This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.
Height
200 reduced by
270
70mm
SEZ-KA35VA SEZ-KD35VA
35 30dB 23dB
50 31dB 30dB
71 32dB 30dB
Four Levels Available for All Models
Maximum noise
reduced by 7dB
5
SEZ-KD SERIES
Indoor Unit Outdoor Unit Remote Controller
SUZ-KA25/35VA6
Enclosed in
SEZ-KD25/35/50/60/71VAL (Wireless Remote Controller is enclosed)
SEZ-KD25/35/50/60/71VAL
*optional *optional
SUZ-KA50/60/71VA6
R410A Heatpump INV Std Compact ceiling concealed SEZ Specification Sheet
Models SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Cooling Capacity (Min-Max) kW 2.5 (1.5-3.2) 3.5 (1.4-3.9) 5.1 (2.3-5.6) 5.6 (2.3-6.3) 7.1 (2.8-8.3)
Capacity BTU/h 8,500 11,900 17,400 19,100 24,000
Total Input kW 0.730 1.010 1.578 1.740 2.210
EER W/W 3.42 3.47 3.23 3.22 3.21
Heating Capacity (Min-Max) kW 2.9 (1.3-4.5) 4.2 (1.7-5.0) 6.4 (1.7-7.2) 7.4 (2.5-8.0) 8.1 (2.6-10.4)
Capacity BTU/h 9,800 14,300 21,800 25,200 27,600
Total Input kW 0.803 1.130 1.800 2.200 2.268
COP W/W 3.61 3.72 3.56 3.36 3.57
Indoor Model name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Unit Power supply 1ph 230V 50Hz
External finish Galvanized sheets
CMM 5.5-7.0-9.0 7.0-9.0-11.0 10.0-12.5-15.0 12.0-15.0-18.0 12.0-16.0-20.0
Airflow (low-med2-med1-high)
CFM 194-247-318 247-318-388 353-441-530 424-530-636 424-565-706
External static pressure Pa 5 / 15 / 35 / 50
Opearation control and thermostat Remote control and Built-in
Noise level (low-med2-med1-high) dB (A) 22-25-29 23-28-33 29-33-36 29-33-37 29-34-39
Unit drain pipe (outer diameter) mm 32
W mm 790 990 990 1190 1190
Dimensions (panel) D mm 700 700 700 700 700
H mm 200 200 200 200 200
Weight (panel) kg 18 21 23 27 27
Outdoor Model name SUZ-KA25VA6 SUZ-KA35VA6 SUZ-KA50VA6 SUZ-KA60VA6 SUZ-KA71VA6
Unit Power supply 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz 1ph 230V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear expansion valve
CMM 32.6 36.3 44.6 40.9 50.1
Cooling
CFM 1151 1281 1574 1444 1769
Airflow
CMM 34.7 34.8 44.6 49.2 48.2
Heating
CFM 1225 1228 1574 1737 1701
Cooling dB (A) 47 49 52 55 55
Noise level
Heating dB (A) 48 50 52 55 55
W mm 800 800 840 840 840
Dimensions D mm 285 285 330 330 330
H mm 550 550 880 880 880
Weight kg 30 35 54 50 53
Max. height difference m 12 12 30 30 30
Max. piping length m 20 20 30 30 30
Pipe size (outer diameter) mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88
Chargeless piping length m 7 7 7 7 7
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
6
7
PLA-RP50/71/100/125/140EA
PLA SERIES
A complete line-up including deluxe units that offer added energy savings. The incorpora-
tion of wide air-outlet and the “3D i-see Sensor” enhances airflow distribution control,
achieving an enhanced level of comfort throughout the room. The synergy of higher
energy efficiency and more comfortable room environment results in the utmost user sat-
isfaction.
1.2m
1.6m
2.0m
2.4m
Grille Elevation Remote Controller Wired Remote Controller Wireless Remote Controller 2.8m
(comes with the automatic elevation panel)
3.2m
3.6m
4.0m
Maximum 4m
Automatic elevation
Easy Installation
After reviewing the power supply terminal position in the electrical The top and bottom positions of the liquid and gas pipes have been re-
box, the structure was redesigned to improve connectivity. This has versed to allow the gas pipe work, which requires more effort, to be
made previously complex wiring work easier. completed first. Further, through structural innovations related to the
space around the pipes, the area where the spanner can be moved
■ Previous model (B Series) ■ New model (E Series)
has been increased, thus improving liquid pipe work and enabling it to
be completed smoothly.
■ Previous model (B Series) ■ New model (E Series)
50° 70°
The structure of the panel has been revised Installation is possible without removing the After reviewing the structure and materials,
and is now equipped with a temporary hang- screws for the corner panel and the control weight has been reduced approximately 20%
ing hook. This has improved work efficiency box, simply loosen them. This lowers the risk compared to the previous model, reducing the
during panel installation. of losing screws. burden of installation.
■ Corner panel ■ Control box cover
8
for S & P SERIES
Detects number of people
3D i-see Sensor detects the number of people in the room and sets Detects number
the air-conditioning power accordingly. This makes automatic pow- of people
er-saving operation possible in places where the number of people
entering and exiting is large. Additionally, when the area is continu-
ously unoccupied, the system switches to a more enhanced pow-
er-saving mode. Depending on the setting, it will save additional ca- Detects people’s
pacity or stop operation altogether. position
12m
8 7 6 4 53 2 1 1 2 3 4 5 6 7 8
Cooling Heating
9
PLA-RP SERIES
Indoor Unit Outdoor Unit
PLA-RP50/71/100/125/140EA
Panel
With With With With
Panel Signal 3D i-see Wireless Auto
Receiver Sensor Remote Elevation
Controller
PLP-6EA
PLP-6EAL SUZ-KA50/71 PUHZ-P100 PUHZ-P125/140
PLP-6EAE
PLP-6EALE
PLP-6EAJ
PLP-6EAJE
PLP-6EALM
PLP-6EALME
Remote Controller
✽
Guaranteed Opearating Range Cooling* -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -10~+24 -10~+24 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
10
PEAD-RP50/71/100/125/140JA(L)Q
PEAD SERIES
The thin, ceiling-concealed indoor units of this series are the perfect answer for the air
conditioning needs of buildings with minimum ceiling installation space and wide-
ranging external static pressure. Energy-saving efficiency has been improved, reduc-
ing electricity consumption and contributing to a further reduction in operating cost.
Reduction of
250mm 75mm
(models 100 –140)
compared to PEAD-EA
PEAD-RP JAQ
11
PEAD-RP SERIES
Indoor Unit Outdoor Unit
PEAD-RP50/71/100/125/140
Remote Controller
Guaranteed Opearating Range Cooling* -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -10~+24 -10~+24 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
12
PKA SERIES PKA-RP100KAL
The compact, wall-mounted indoor units offer the convenience of simple installation,
and a large product line-up ensures a best-match solution. Designed for highly effi-
cient energy savings, the PKA Series is the answer to your air conditioning needs.
PKA-RP KAL
13
PKA-RP SERIES
Indoor Unit Outdoor Unit
PKA-RP100KAL
PUHZ-P100
Remote Controller
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
14
PCA SERIES PCA-RP35/50/60/71/100/125/140KAQ
A stylish new indoor unit design and airflow settings for both high- and low-ceiling
interiors expand installation possibilities. Together with exceptional energy-saving
performance, these units are the solution to diversified air conditioning needs.
PCA-KAQ
Equipped with Automatic Air-speed Adjustment Equipped with High- /Low-ceiling Modes
In addition to the conventional 4-speed setting, units are now equipped Units are equipped with high- and low-ceiling operation modes that
with an automatic air-speed adjustment mode. This setting automati- make it possible to switch the airflow volume to match room height.
cally adjusts the air-speed to conditions that match the room environ- The ability to choose the optimum airflow volume makes it possible
ment. At the start of heating/cooling operation, the airflow is set to to optimize the breezy sensation felt throughout the room.
high-speed to quickly heat/cool the room. When the room tempera-
ture reaches the desired setting, the airflow speed is decreased auto- High Standard Low
Capacity
matically for stable comfortable heating/cooling operation. ceiling ceiling ceiling
35 3.5m 2.7m 2.5m
50 3.5m 2.7m 2.5m
Strong Gentle 60 3.5m 2.7m 2.5m
71 3.5m 2.7m 2.5m
100 4.2m 3.0m 2.6m
125 4.2m 3.0m 2.6m
Start of cooling/heating… After room temperature is stabilized… 140 4.2m 3.0m 2.6m
15
PCA-RP SERIES
Indoor Unit Outdoor Unit Remote Controller
Guaranteed Opearating Range Cooling* -10~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -10~+24 -10~+24 -10~+24 -10~+24 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
16
PSA SERIES
Installation of this floor-standing series is easy and quick.
An excellent choice when there is a sudden need for an air conditioner to be installed.
Back
Left side
Right side
Underneath
600mm 360mm
17
PSA-RP SERIES
Indoor Unit Outdoor Unit Remote Controller
PSA-RP100/125/140KA
Guaranteed Opearating Range Cooling* -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
[Outdoor] Heating -15~+21 -15~+21 -15~+21 -15~+21 -15~+21 -15~+21
・Rating conditions Cooling - Indoor: 27℃(80℉)DB, 19℃(66℉)WB, Outdoor: 35℃(95℉)DB, Heating - Indoor: 20℃(68℉)DB, Outdoor: 7℃(45℉)DB, 6℃(43℉)WB
・Refrigerant piping length (one-way): 7.5m(25ft)
・Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
*Operation air protection guide is required where ambient temperature is lower than -5℃.
18
NOTICE
■ Do not install indoor units in areas (e.g. mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ Our air-conditioning equipments and heat pumps contain a fluorinated greenhouse gas, R410A (GWP: 2088) or
R32 (GWP: 675). *These GWP values are based on Regulation (EU) No.517/2014 from IPCC 4th edition. In case of
Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP: 1975), R32 (GWP: 550)
■ When installing or relocating or servicing our air-conditioning equipment, use only the specified refrigerant (R410A or R32)
to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.