Poweredge M910: Technical Guide
Poweredge M910: Technical Guide
Poweredge M910: Technical Guide
Name
Technical Guide
Dell, PowerEdge, EqualLogic, PowerVault, OpenManage, and ReadyRails are trademarks of Dell, Inc.
Citrix® and XenServer™ are trademarks of Citrix Systems, Inc. and/or one or more of its subsidiaries,
and may be registered in the United States Patent and Trademark Office and in other countries.
Intel, Xeon, and Speedstep are registered trademarks and MMX and Core are trademarks of Intel
Corporation in the U.S. and other countries. HP and COMPAQ are trademarks of Hewlett-Packard
Company. Broadcom is a registered trademark and NetXtreme is a trademark of Broadcom
Corporation and/or its affiliates in the United States, certain other countries and/or the EU.
CommVault Galaxy and Simpana are registered trademarks of CommVault Systems, Inc. InfiniBand is
a registered trademark and service mark of the InfiniBand Trade Association. Matrox is a registered
trademark of Matrox Electronic Systems Ltd. Microsoft, Windows, Windows Server, SQL Server, and
BitLocker, and Hyper-V are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries. Mellanox is a registered trademark of Mellanox
Technologies, Inc. and ConnectX, InfiniBlast, InfiniBridge, InfiniHost, InfiniRISC, InfiniScale, and
InfiniPCI are trademarks of Mellanox Technologies, Inc. Novell is a registered trademarks of Novell,
Inc., in the United States and other countries. PCI Express is a registered trademark of PCI-SIG. Red
Hat is a registered trademark of Red Hat, Inc. in the United States and other countries. Linux is a
registered trademark of Linus Torvalds. Symantec and Backup Exec are trademarks owned by
Symantec Corporation or its affiliates in the U.S. and other countries. QLogic and PathScale are
registered trademarks of Qlogic Corporation. VMware is a registered trademark and vSphere is a
trademark of VMware, Inc. in the United States and/or other jurisdictions. vRanger, vFoglight,
vConverter, Vizioncore vOptimizer, and Vizioncore vEssentials are trademarks of Vizioncore Inc.
Other trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and
names of others.
©Copyright 2010 Dell Inc. All rights reserved. Reproduction or translation of any part of this work
beyond that permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful
and strictly forbidden.
Revision 1 September 2010
Table of Contents
1 Product Comparison ........................................................................................... 5
1.1 Overview .................................................................................................. 5
1.2 Product Comparison ..................................................................................... 6
2 New Technologies .............................................................................................. 8
2.1 Overview .................................................................................................. 8
2.2 Detailed Information .................................................................................... 8
2.2.1 Intel Xeon Processors .............................................................................. 8
2.2.2 Intel 7500 Chipset .................................................................................. 8
2.2.3 FlexMem Bridge .................................................................................... 8
2.2.4 IO Hub (IOH) with Intel QuickPath Architecture ............................................... 8
2.2.5 DDR3 Memory ....................................................................................... 8
2.2.6 PCI Express Generation 2 ......................................................................... 9
2.2.7 Internal Redundant SD Module ................................................................... 9
2.2.8 iDRAC6 Express ..................................................................................... 9
3 System Information .......................................................................................... 10
3.1 Overview ................................................................................................ 10
3.2 Product Features Summary ........................................................................... 10
4 Mechanical .................................................................................................... 12
4.1 Overview ................................................................................................ 12
4.2 Module Dimensions and Weight ...................................................................... 12
4.3 Internal Module......................................................................................... 12
4.4 Security .................................................................................................. 13
4.5 Cover Latch ............................................................................................. 13
4.6 TPM (Trusted Platform Module) ...................................................................... 13
4.7 Power Off Security ..................................................................................... 14
4.8 USB Key .................................................................................................. 14
4.9 Battery ................................................................................................... 14
4.10 Field Replaceable Units (FRU)........................................................................ 14
5 Operating, Thermal, and Acoustic......................................................................... 15
5.1 Overview of Operating and Storage Conditions .................................................... 15
5.2 Acoustics ................................................................................................ 16
5.3 Thermal.................................................................................................. 17
5.4 Power Efficiency ....................................................................................... 17
6 Processors ..................................................................................................... 18
6.1 Overview ................................................................................................ 18
6.2 Features ................................................................................................. 18
6.3 Supported Processors .................................................................................. 19
6.4 Processor Configurations .............................................................................. 19
6.5 FlexMem Bridge ........................................................................................ 19
7 Memory ........................................................................................................ 21
7.1 Overview ................................................................................................ 21
7.2 DIMMs Supported ....................................................................................... 22
7.3 Slots /Risers............................................................................................. 22
7.4 Intel 7500 Scalable Memory Buffer (SMB)........................................................... 22
7.5 Memory RAS Support ................................................................................... 22
7.5.1 Sparing ............................................................................................. 22
7.5.2 Mirroring ........................................................................................... 23
7.5.3 Supported Memory Configurations ............................................................. 24
Tables
Table 1. Product Comparisons ................................................................................. 6
Table 2. Product Features .................................................................................... 10
Table 3. Operating and Storage Conditions ................................................................ 15
Table 4. Typical Configuration Used in Testing ........................................................... 16
Dell PowerEdge M910 Technical Guide 3
Dell
Table 5. Processor Cache Sizes (Package LGA1567) ...................................................... 18
Table 6. Supported Processors ............................................................................... 19
Table 7. PowerEdge M910 Sparing and Mirroring .......................................................... 22
Table 8. Supported Memory Configurations ................................................................ 24
Table 9. RAID Configurations ................................................................................. 31
Table 10. Storage Controllers Supported on the M910 ..................................................... 31
Table 11. Supported Video Modes ............................................................................ 33
Table 12. Virtualization Software ............................................................................. 36
Table 13. Unified Server Configurator Features and Description......................................... 39
Table 14. Features List for BMC, iDrac, and vFlash ........................................................ 40
Table 15. Industry Standards and URLs ...................................................................... 43
Figures
Figure 1. M1000e................................................................................................ 12
Figure 2. Internal Module View ............................................................................... 13
Figure 3. Diagram of FlexMem Bridge Routing.............................................................. 20
Figure 4. Memory Diagram .................................................................................... 21
Figure 5. PowerEdge M910 2P Mirroring ..................................................................... 23
Figure 6. M910 4P Mirroring ................................................................................... 23
Figure 7. 2.5‖ HDD Carrier .................................................................................... 30
Front Side Bus Four Intel® QuickPath Two Intel® QuickPath Four Intel® QuickPath Up to 6.4 GT/s Intel®
Interconnect (QPI) links Interconnect (QPI) Interconnect (QPI) QuickPath Interconnect
links links (QPI) links
# Proc Sockets 2/4 2 2/4 2/4/6
Max # Cores per 2S w/ up to16 cores Up to 4 2S w/ up to16 cores 2S w/ up to16 cores
Socket 4S w/ up to 32 cores 4S w/ up to 32 cores 4S w/ up to 32 cores
L2/L3 Cache L2 cache:1.5MB or 2MB 4MB and 8MB L2 cache:1.5MB or 2MB L3 cache: 12MB, 18MB
L3 cache: 12MB, 18MB or L3 cache: 12MB, 18MB or 24MB
24MB (shared) or 24MB (shared)
Chipset Intel® 7500 Intel® 5520 Intel® 7500 Intel® 7500
DIMMs 32 x DDR3 18 DDR3 32 x DDR3 64 x DDR3
Min/Max RAM 4GB–512GB 1GB–192GB 4GB–512GB 4GB – 1TB
Form Factor Full Height Blade, Dual Full Height Blade, Dual 2U Chassis, Rack 4U chassis, Rack
Slot Slot
HD Bays (2.5” 2 4 6 16
only)
HD Types SAS/SSD SAS/SSD SAS/SSD SAS/SSD
Integrated H200/H700 (factory H200/H700 H200/H700 H200/H700
Standard HD installed) and PERC6 as PERC6
Controller custom kit
Optional HD H200/H700 Integrated SAS6/iR PERC6i with PERC H800 or 6Gbps PERC H800 or 6Gbps
Controller controller RAID battery SAS SAS
(Battery backup for the
H700 and PERC6 options
only)
Availability Hot-swap hard drives Hot-swap hard drives Hot-swap hard drives Hot-swap hard drives
Hot-swap redundant Hot-swap redundant Hot-swap redundant Hot-swap redundant
power and cooling power and cooling power and cooling power and cooling
ECC memory ECC memory ECC memory ECC memory
Single Device Data Single Device Data Single Device Data Single Device Data
Correction (SDDC) Correction (SDDC) Correction (SDDC) Correction (SDDC)
Supports memory Supports memory Supports memory supports memory
demand and patrol demand and patrol demand and patrol demand and patrol
scrubbing scrubbing scrubbing scrubbing
High-availability failover High-availability High-availability High availability
cluster support failover cluster failover cluster
support support
2 New Technologies
2.1 Overview
The PowerEdge M910 server includes the following new features:
Intel Xeon Processor 7500 Series (4s) and Intel Xeon Processor 6500 Series (2s) 4-, 6-, and 8-
core processors
Intel 7500 Chipset
FlexMem Bridge
IO Hub (IOH) with Intel® QuickPath Architecture
DDR3 memory
PCI Express® Generation 2
Optional Redundant SD media for embedded hypervisor
iDRAC6 Express
3 System Information
3.1 Overview
The PowerEdge M910 is an innovative blade design that allows scaling from 2 to 4 sockets (no single
or 3 socket support) based on a new generation of Intel four-socket enhanced processors, RAM, and
management while still taking advantage of the M1000e chassis architecture. Along with the M1000e
chassis, the PowerEdge M910 server leads the industry in high speed, redundant IO throughput and
power efficiency with more RAM slots in the 2-socket space.
Up to Four Intel® Xeon® processor 7500 series Quad-, Six-, or Eight-Core; or,
Processors
Up to Two Intel® Xeon® processor 6500 series Quad-, Six-, or Eight-Core
Internal:
2.5‖ 6Gbs SAS (15K): 73GB, 146GB
2.5‖ 6Gbs SAS (10K): 146GB, 300GB
2.5‖ 6Gbs SAS (7.2K): 500GB
Storage1 2.5‖ SSD: 50GB, 100GB
External:
Dell™ EqualLogic™ PS Series
Dell™ PowerVault™ MD Series & NX Series
Dell/EMC CX Series, AX Series & NS Series
Fully populated mezzanine card slots and switch modules will yield 3 highly
available, redundant I/O fabrics per blade.
I/O Mezzanine Card 1Gb & 10Gb Ethernet:
Options Broadcom® Dual-Port Gb Ethernet w/ TOE (BCM-5709S)
Intel® Quad-Port Gb Ethernet
Broadcom® Quad-Port Gb Ethernet (BCM-5709S)
1
GB means 1 billion bytes and TB equals 1 trillion bytes; actual capacity varies with preloaded material and
operating environment and will be less.
Dell PowerEdge M910 Technical Guide 10
Dell
QLogic® Dual-Port FC8 Fibre Channel Host Bus Adapter (HBA) (QME2572)
Emulex® Dual-Port FC8 Fibre Channel Host Bus Adapter (HBA) (LPe1205-M)
Citrix® XenServer™
Microsoft® Hyper-V™ via Microsoft® Windows Server® 2008
VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1)
For more information on the specific versions and additions, visit the Operating
System Support Matrix for Dell PowerEdge Systems on Dell.com.
4 Mechanical
4.1 Overview
The M910 is a full height blade server that requires an M1000e chassis (shown in Figure 1) to operate.
Figure 1. M1000e
It occupies 2 slots in the M1000e rack chassis for a maximum of 8 blades in one M1000e chassis. It
can be mixed with other existing Dell blades and is designed to mix with possible future half-height-
double-wide and full-height-double-wide blades. Some highlights are:
• Support for RAID
• Support for persistent storage (internal USB connector and two external SD card slots)
Refer to the PowerEdge M1000e Technical Guide for information on fans, power and power supply,
racks, security, and other chassis information.
4.4 Security
Configurable client IP address range for clients connecting to iDRAC6.
4.9 Battery
A replaceable coin cell CR2032 3V battery is mounted on the planar to provide backup power for the
Real-Time Clock and CMOS RAM on the ICH9 chip.
5.2 Acoustics
Adherence to Dell’s high sound quality standards. Sound quality is different from sound power level
and sound pressure level in that it describes how humans respond to annoyances in sound, like
whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence ratio of
a tone, and this is listed in the table below.
Acoustical Performance of Typical Configuration: When installed in the M1000e blade chassis,
typical configuration2 (shown in Table 4of M910 blade results in the following idle acoustical
performance in 23±2° C ambient:
LwA-UL3 = 8.1 bels and no prominent tones4
2
Typical configuration means projected average quantity, type, capacity, speed, etc., of components. Configuration for
which data reported is listed in Table 4.
3
LwA – UL is the upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and measured in
accordance to ISO 7779 (1999).
4
Prominent tone: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete tones are
prominent. The system is placed in a rack with its bottom at 75 cm from the floor. The acoustical transducer is at front
bystander position, ref ISO7779 (1999) Section 8.6.2.
Dell PowerEdge M910 Technical Guide 16
Dell
5.3 Thermal
The M910 thermal solution includes:
Optimized airflow impedance for individual blade and chassis level airflow balancing
Custom air baffling directs airflow through the components to maintain proper cooling
Custom-designed heat sinks maintain CPU, IOH, and Intel 7500 chip temperatures within
thermal design targets
Highly Optimized Fan Control Algorithm such as the following:
o Base fan speeds are a function of hardware configuration and ambient temperature
to minimize airflow for a given environment
o PID control algorithms are used for both CPU and DIMMs to maintain appropriate
thermal margin
o Double refresh switching allows for DIMM temperature excursions up to 95°C while
maintaining performance and thermal design targets as follows:
The M910 thermal algorithm monitors the thermal sensor on each DIMM to
maintain DIMM temperatures below the typical 85°C specification in normal
operating conditions.
Under extreme operating conditions, the thermal algorithm can switch the
DIMMs into Double Refresh mode allowing an additional 10°C of thermal
headroom. In Double Refresh mode, DIMMs are allowed to operate as high
as 95°C.
6 Processors
6.1 Overview
The Intel Xeon processor 6500 and 7500 series 4S (Expandable Processor) is the microprocessor
designed specifically for servers and workstation applications. The processor features quad-core
processing to maximize performance and performance/watt for data center infrastructures and
highly dense deployments. The Intel Xeon processor 6500 and 7500 series also features Intel® Core™
micro-architecture and Intel® 64 architecture for flexibility in 64-bit and 32-bit applications and
operating systems. The Intel Xeon processor 6500 and 7500 series supports all Streaming SIMD
Extensions (including SSE2, SSE3, and SSE4) and Intel 64 instruction.
The Intel Xeon processor 6500 and 7500 series 4S (Expandable Processor) uses a 1567-pins Land Grid
Array (LGA1567) package that plugs into a surface-mount socket. The M910 provides support for two
or four processors.
6.2 Features
Key features of the Intel Xeon processor 6500 and 7500 series include:
• Up to eight cores per socket
• Up to 24MB shared L3 cache
• 45nm process technology
• Four full‐width, bidirectional point‐to‐point Intel® QuickPath Interconnect (Intel® QPI)
links at 6.4 GT/s
• Support for 95W, 105W, and 130W processors
• Four Intel® Scalable Memory Interconnects (Intel® SMI) at 6.4 GT/s
• Socket—LS, LGA 1567 package
• No termination required for non‐populated CPUs (must populate CPU socket 1 first)
• Integrated Intel® QuickPath DDR3 memory controller
• 64‐byte cache line size
• RISC/CISC hybrid architecture
• Compatible with existing x86 code base
• Optimized for 32‐bit code
• MMX support
• Execute Disable Bit
• Intel® Wide Dynamic Execution
• Executes up to four instructions per clock cycle
• Simultaneous Multi‐Threading (SMT) capability (2 threads/core)
• Support for CPU Turbo Mode (on certain SKUs)
• Increases CPU frequency if operating below thermal, power, and current limits
• Streaming SIMD (Single Instruction, Multiple Data) Extension 4
Dell PowerEdge M910 Technical Guide 18
Dell
• Intel® 64 Technology
• Intel® VT‐x and VT‐d Technology for virtualization support
• Enhanced Intel® SpeedStep Technology
• Demand‐based switching for active CPU power management as well as support for ACPI P‐
States, C‐States, and T-States
IOH
Modern processors are capable of tremendous workloads, and many types of utilization patterns such
as virtualization often run into memory capacity issues well before the processors reach a saturation
point. FlexMem Bridge technology was designed to assist those customers that have workloads that
are memory intensive.
Customers who scale their workloads in the future to a point where they would need additional
processing power can simply replace the FlexMem Bridge with additional processors to meet those
needs.
Due to power limitations, the PowerEdge M910 will only support two X7560 (130W) processors. In an
upgrade for a server with two 130W CPUs, the CPUs and the heatsink must be changed to the 95W or
105W CPUs. If the server has only the 95W or 105W CPUs, CPUs can simply be swapped out.
7 Memory
7.1 Overview
The PowerEdge M910 uses DDR3 memory providing a high-performance, high-speed memory interface
capable of low latency response and high throughput. The PowerEdge M910 supports Registered ECC
DDR3 DIMMs (RDIMM) only. Each DDR3 DIMM is driven by the Intel® 7500 Scalable Memory Buffer
(Intel® 7500 SMB). A memory buffer has two DDR3 channels off it. Each of these channels can
support up to 2 DIMMs running at 1067MHz (or slower) speeds. Intel® 7500 SMB will support single-,
dual-, and quad-rank DIMMs. Up to four 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs are supported per
channel, for a total of up to 512 GB. Single-rank, dual rank, and quad-rank RDIMMs are supported.
Across CPUs, DIMM populations can be different on the memory for each CPU as long as the
population rules for each CPU socket are followed. Additionally, all CPU sockets operate in the same
RAS mode and are set up with the same memory timing parameters.
4-socket platform capability (64 DIMMs):
Up to 16 DDR3 DIMMs per socket through use of up to four
Scalable Memory Buffers
Support for up to 16GB DDR3 DIMMs
1TB with 16GB DIMMS
Memory types supported:
1066MHz DDR3 (800 & 1333MHz availability
depends on OEM validation)
Registered (RDIMM)
Single-rank (SR), dual-rank (DR), quad-rank (QR)
Actual system memory speed depends on specific processor capabilities:
6.4GT/s SMI link speed capable of running memory speeds up to 1066Mhz
5.86GT/s SMI link speed capable of running memory speeds up to 978Mhz
4.8GT/s SMI link speed capable of running memory speeds up to 800Mhz
The M910’s DIMM sockets are placed 0.40‖ apart, center‐to‐center, to provide enough space for
sufficient airflow to cool stacked DIMMs. DIMMs must be installed in each channel starting with the
DIMM farthest from the processor (DIMM 1). Population order is identified by silkscreen and a label.
The order is dependent on the memory configuration used. See Table 8 for DIMM naming and
population ordering.
Sparing Mirroring
Type Rules enforced 1P 2P 4P Rules Enforced
Rank No support Inter-socket Inter- 32 DIMM only,
The capacity of the spare (hemisphere socket Mirrored must match
rank must be greater mode
than that of any other enabled)
rank on the channel
7.5.1 Sparing
For information, see System Memory in the Dell PowerEdge Modular Systems Hardware Owner’s
Manual.
DIMM4
DIMM6
DIMM8
DIMM1
DIMM2
DIMM3
DIMM5
DIMM7
DIMM8
DIMM7
DIMM6
DIMM5
DIMM4
DIMM3
DIMM2
DIMM1
A MBOX0 MBOX0
D
CPU1 CPU2
MBOX1 MBOX1
DIMM4
DIMM6
DIMM8
DIMM1
DIMM2
DIMM3
DIMM5
DIMM7
DIMM8
DIMM7
DIMM6
DIMM5
DIMM4
DIMM3
DIMM2
DIMM1
C B
For 4-processor configurations, the PowerEdge M910 will also support mirroring in the inter-socket
mode (note that intra-socket is not possible in 4P because each CPU has only one MBox connected to
memory buffers). In this 4P case, the memory on CPU1 will be mirrored with memory on CPU3, while
memory on CPU2 is mirrored with memory on CPU4. Figure 6 depicts the mirroring logic for 2P
configurations. A,B,C and D represent the DIMM socket groups.
DIMM8
DIMM7
DIMM6
DIMM5
DIMM4
DIMM3
DIMM2
DIMM1
A MBOX0 MBOX0
CPU1 CPU2
MBOX1 MBOX1
DIMM2
DIMM4
DIMM7
DIMM1
DIMM3
DIMM5
DIMM6
DIMM8
B
DIMM2
DIMM4
DIMM7
DIMM1
DIMM3
DIMM5
DIMM6
DIMM8
MBOX0 MBOX0
D
CPU3 CPU4
MBOX1 MBOX1
DIMM8
DIMM7
DIMM6
DIMM5
DIMM4
DIMM3
DIMM2
DIMM1
8 Chipset
The PowerEdge M910 system board incorporates the Intel® 7500 chipset for I/O and processor
interfacing. The 7500 chipset is designed to support Intel® Xeon® processor 6500 and 7500 series 4S
family, Intel® QPI Interconnect, DDR3 memory technology, and PCI Express Generation 2 (PCIe 2).
The 7500 chipset consists of the IOH QuickPath Interconnect (QPI), Intel® 7500 Scalable Memory
Buffer, and the ICH10 South Bridge.
• Six x1 PCIe Gen1 ports, with the capability of combining ports 1‐4 as a x4 link
• PCI Bus 32‐bit Interface Rev 2.3 running at 33 MHz
• Six UHCI and two EHCI (High‐Speed 2.0) USB host controllers, with up to twelve USB ports
9 BIOS
9.1 Overview
The PowerEdge M910 BIOS is based on the Dell BIOS core, and supports the following features:
• IA‐32 Intel Xeon 7500 chipset 4S
• Simultaneous Multi‐Threading (SMT)
• CPU Turbo Mode
• PCI 2.3
• Plug n’ Play 1.0a
• MP (Multiprocessor) 1.4
• Boot from hard drive, optical drive, iSCSI drive, USB key, and SD card
• ACPI
• Direct Media Interface (DMI)
• PXE and WOL support for on‐board NICs
• Memory mirroring and sparing
• SETUP access through <F2> key at end of POST
• USB 2.0 (USB boot code is 1.1 compliant)
• F1/F2 error logging in CMOS
• Virtual KVM, CD
• UEFI (Unified Extensible Firmware Interface) 2.1 support
11.2 Options
Available options for all 4 slots include:
• Mellanox® QDR ConnectX™ Dual-Port Quad Data Rate (QDR) InfiniBand
• Broadcom® BCM57711 Dual Port KX4 MC (10G)
• Broadcom® BCM5709S Dual Port SERDES
• Broadcom® BCM5709S Quad Prot SERDES
• Intel® Dual Port 10G KX4 MC
• Intel® Quad Port 1G SERDES MC
• Dual Port FC8 Qlogic® QME2572
• Dual Port FC8 Emulex® LPe1205-M
• Qlogic® CNA QME8142 (10Gb Enhanced Ethernet + FCoE)
• Emulex® CNA OCM20102FM (10Gb Enhanced Ethernet)
• Intel® 52599 (10Gb Enhanced Ethernet)
12 Storage
12.1 Drives
The PowerEdge M910 supports up to two 2.5‖ SAS hard disk drives.
• 2.5" SAS (10K rpm): 146GB, or 300GB
• 2.5" SAS (15K rpm): 73GB or 146GB
• 2.5‖ SAS (7.2k rpm): 500GB
• 2.5‖ SSD: 50GB or 100GB
Internal
PERC H200 Storage x4 integrated mini
Backplane Yes – Max 1 X4 No 0, 1, 10 No
Integrated slot SAS wide
Storage
14 Rack Information
For information on rack and cable accessories for the M910, see the PowerEdge M1000e Technical
Guide and the M1000e Rack and Cable Advisor Tool.
15 Operating Systems
The PowerEdge M910 is designed to meet the MSFT WinLogo 3.0 design specifications. For the most
up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on
Dell.com.
16 Virtualization
16.1 Overview
Table 12. Virtualization Software
Hypervisor Factory Install Certification
VMware®
DIB/FI/NFI Yes
ESX/ESXi™ 3.5U5
VMware®
DIB/FI/NFI Yes
ESX/ESXi™ 4.0U1
Windows Server® 2008 Yes, included in Windows Server
FI
R2 with Hyper-V™ 2008 R2 WHQL process
Citrix®
FI Yes
XenServer™ 5.6
16.3 Vizioncore
Vizioncore's easy-to-use virtualization software products support business continuity and disaster
recovery, high availability, monitoring, automation, P2V and optimization. The software is agent-less
and can co-exist with other leading backup software vendors, or be used as a standalone solution.
vRanger™ Pro is a backup and restore solution for virtualized environments.
vFoglight™ Standard and Professional editions help organizations monitor, understand and
analyze their virtual infrastructure by managing the relationships and interaction between
all the components in the virtual environment.
vConverter™ helps convert servers to the VMware, Microsoft, XenServer or Virtual Iron
platforms.
vReplicator is a host-level software-based replication solution for VMware infrastructure
which enables companies to leverage virtualization to support High Availability (HA) and
Disaster Recovery (DR) strategies.
Vizioncore™ vOptimizer Pro helps administrators understand storage utilization so they
can make real-time adjustments in allocations. It presents the financial impact of
reclaimed storage per virtual machine (VM), per host, and cumulative cost savings across
the enterprise through historical detailed reports.
vControl is a VM management solution that provides self-service provisioning, multi-VM
control and task-based automation. vControl lets VM consumers build and deploy VMs for
themselves, while providing administrators a single interface for task-based
administration of VMs.
Vizioncore vEssentials™ is a software bundle of vFoglight Pro, vRanger Pro and
vReplicator.
More information can be found at http://vizioncore.com/asg/.
17 Systems Management
17.1 Overview
Dell aims on delivering open, flexible, and integrated solutions that help you reduce the complexity
of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell
PowerEdge Servers with a wide selection of Dell-developed management solutions gives you choice
and flexibility, so you can simplify and save in environments of any size. To help you meet your
server performance demands, Dell offers Dell™ OpenManage™ systems management solutions for:
• Deployment of one or many servers from a single console
• Monitoring of server and storage health and maintenance
• Update of system, operating system, and application software
Dell offers IT management solutions for organizations of all sizes—priced, sized, and supported right.
18 Peripherals
18.1 USB peripherals
The PowerEdge M910 provides an internal USB connector for a USB flash memory key. The USB
memory key can be used as a boot device, security key, or mass storage device.