1 Synapsis Configuration Hints (Boxpc Checklist)
1 Synapsis Configuration Hints (Boxpc Checklist)
Engineering
1 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
29 2 Detailed Description
30 2.1.1 Link Speed of LAN adapter
31 All LAN Adapter of the NavNet (Local Area Connection) MUST be set to 1Gbps Full Duplex
32 1. Open the properties of the “Local Area Connection” adapter and press the “Configure” button
33 next to the network controller.
34 2. Select the “Advanced” tab and the property “Speed & Duplex”. Set it to “1.0 Gbps Full Duplex”:
35
48
2 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
49 d. Double-click on the “Internet Protocol (TCP/IP)” and select the WINS tab.
50 e. Ensure, that “Enable LMHOSTS lookup” is unchecked and “Disable NetBIOS over
51 TCP/IP” is selected.
52
53 f. Repeat these steps for the Loopback adapter.
54 g. If NetBIOS is not required by a third-party software using the second LAN adapter,
55 repeat steps a to e for the second LAN adapter.
56
57 2. Open the file C:\WINDOWS\system32\drivers\etc\hosts with a text editor. This file contains the
58 IP addresses for all computer names which cannot be resolved by DNS or NetBIOS. Because
59 NetBIOS was deactivated in the last step, we have to enter a IP address for every PC in the
60 system. For each PC, add a line containing a IP address of the PC and the name of the PC,
61 separated by a tab or spaces, e.g.:
62
63 192.168.10.11 MFC1
64
65 For example, the file shall contain the following lines for a system containing 4 MFCs:
66
67 192.168.10.11 MFC1
68 192.168.10.21 MFC2
69 192.168.10.31 MFC3
70 192.168.10.41 MFC4
71 Copy the file C:\WINDOWS\system32\drivers\etc\hosts to all PCs in the system.
72
73
3 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
74
75
76 Required content of the hosts file for a system with 4 MFCs
77 After performing these steps on all PCs, test the connectivity of the PCs in the system:
78 Open a command shell (Start Run cmd) and ping the other PCs in the system using the
79 computer name, e.g.:
80
81 “ping MFC2”
82
83 The IP address for the PC shall be correctly resolved and the remote PC shall reply to the ping
84 request (assuming the remote PC is running).
85 Repeat this step on each PC in the system.
86 Check access to the shared folders of the remote PCs: Open a explorer and enter
87 a shared folder in the address bar, e.g. \\mfc2\d$. The content of the folder shall be shown
88 (assuming the remote PC is running).
4 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
92
IP Unit Port
93
5 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
99
100 Select the newly added console on the left and expand it. Select the node BIP and expand the node
101 Services.
102 The following services (Tasks) should be visible after expansion.
103 - SyncDataPersist (Task)
104 - DisplayService (Task)
105 - TimeSync (Task)
106
107
6 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
121
122
123
124 Select switch by switch by the „Web Browser Access“, the standard password is „password“
125
126 Based at the standard configuration you have to do the following settings at the RSTP:
127
128 1. Define System Location
7 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
129 at „System“
130 „Management“
131 „System Information“
132 Define System Location, it is helpfull to allocate the switch to the consoles.
133 f.ex. Switch at MFC1 „Switch MFC1“
134
135
136 2. IP-configuration
137 „System“
138 „Management“
139 „IP Configuration“
140 Select „Static IP Adress“,
141 for switches at the IBS is generelly the adressrange 192.168.10.200 to
142 192.168.10.229 reserved.
143 Here it makes also sense to allocate the switch to the console.
144 „Switch MFC1“ 192.168.10.201
145 „Switch MFC2“ 192.168.10.202
146 Subnet Mask is always 255.255.255.0
147 Default Gateway is 192.168.10.254
148
149
150 3. RSTP Konfiguration
151 at „Switching“
152 „STP“
8 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
153 „Advanced“
154 „STP Configuration“
155 Select „Spanning Tree State“
156 Select „STP Operation Mode“ RSTP
157
158
159
160
161 4. Configuration of the RSTP Ports
162 „Switching“
163 „STP“
164 „Advanced“
165 „CST Configuration“
166 with Ports/ STP Status set all redundant network ports to “Enable”
167
168
9 / 10
Seite
SYNAPSIS CONFIGURATION HINTS
Engineering
169 C h a ng e Hi s t or y
Version Datum Autor Beschreibung der Änderung
0 11-Apr-2017 xyz Mlk
170
10 / 10
Seite