SFGLD 480 1800: Gas Ic-G-B-48-033 Ic
SFGLD 480 1800: Gas Ic-G-B-48-033 Ic
SFGLD 480 1800: Gas Ic-G-B-48-033 Ic
GAS
IC IC-G-B-48-033
DATE
MASS FLOWS
INTAKE AIR FLOW (1) kg/h 4750 3830 2940 2080
EXHAUST GAS FLOW (WET) (1) kg/h 4940 3990 3060 2160
NOTES:
1. 100% LOAD TOLERANCES:
FUEL CONSUMPTION ±5%,
COOLING CIRCUIT AND EXHAUST GASES ± 15%, RADIATION ±25
EXHAUST TEMPERATURE ±20ºC, MASS FLOWS ± 10%.
2. THE ENGINE PERFORMANCE DATA, TIMING ADVANCE AND CARBURETION SETTINGS ARE VALID FOR A GAS THAT FULFILS THE REQUIREMENTS DEFINED
IN IC-G-D-30-001, IC-G-D-30-002 AND IC-G-D-30-003
3. NET POWER, MECHANICAL PUMPS NOT INCLUDED.
4.POWERS ARE VALID FOR AMBIENT TEMP.< 25ºC AND AN ALTITUDE OF < 500m. OTHER CONDITIONS IN IC-G-B-00-001
5. OVERLOAD NOT ALLOWED
6. THE SPECIFICATIONS AND MATERIALS ARE SUBJECT TO CHANGE WITHOUT NOTIFICATION
7. A ENGINE WITH INLET OR OUTPUT RESTRICTION OVER PUBLISHED LIMITS, OR WITH INADEQUATE MAINTENANCE OR INSTALLATION
CAN MODIFY POWER RATING DATA.
8. EMISSIONS ARE CORRECTED TO 5% OF O2