S5 / S7 Interfaces

IBH Link S7++


If a S7-200 ®, S7-300 ® or S7-400 ® has to
be connected with a PC via Ethernet,
the normal way is to take a CP / Com- transmisson rate and
munication processor. IBHsoftec has MPI® / DP address.
a more flexible solution: The housing of the USB-
IBH Link S7++. If you want to connect S7-Adaptor MPI®, DP,
your PC via Ethernet just take the PPI contains a type
IBH Link S7++. The IBH Link S7++ “B” USB socket. The
is a very small gateway integrated Adaptor can be con-
in a Sub D connector. nected to the PC via the
The IBH Link S7++ replaces the USB cable supplied. The USB-
well known IBH Link S7 and S7-Adaptor MPI® is powered from the PC. The USB-
IBH Link S7 CrossOver. S7-Adaptor MPI®, DP, PPI can be used at any node
in the MPI® bus. A driver for Windows® 98 / 2000 / XP
Additional features:
is supplied.
t 16 PC-connections at the same time
t 32 MPI® / DP-connections at the same time
t Automatic Baudrate-detection IBH Link S5
t RFC1006 As an alternative solution, IBHsoftec has
t RJ45-Plug with autodetect integrated recently introduced the IBH Link S5 for
t PG(PU)-Connector connecting a S5 PLC with a PC. The
t Diagnostic LEDs IBH Link S5 is compact and robust
Ethernet-converter within a 15-pin
t Power supply from the MPI® / DP interface
Sub-D-housing for a connection
t Connection also to passive nodes with power via a switch, a hub or even directly
supply via integrated 24V connector to a PC with a common network
adaptor. The used protocol is the
standard TCP / IP protocol. In this way,
IBH Link S7 Plus the user can benefit from all the advan-
If a S7-200 ®, S7-300 ® or S7-400 ® has tages of Ethernet like remote maintenance
to be connected with a PC via via a standard router or VPN-connections (Vir-
Ethernet, the normal way is to tual Private Network). Likewise, a direct connec-
take a CP / Communication pro- tion to the Internet is possible. All required drivers
cessor. IBHsoftec has a more flex- for the STEP® 5 software from Siemens and for
ible solution: IBH Link S7 Plus. If S5 for Windows® are included.
you want to connect your PC via
Ethernet just take the
IBH Link S7 Plus. The IBH USB-S5-Adaptor
IBH Link S7 Plus is a small gateway. The Interfaces the PC USB
IBH Link S7 Plus offers the same fea- Port with the 15 pin AS511
tures like the well known IBH Link S7. Interface port of the PLC.
Additional features: The 15 pin connector
t 6 PC-connections at the same time housing is made from solid
t PROFIBUS MPI®-Plug with PG(PU)-Connector metal and contains the
t RJ45-Plug integrated complete electronics. The
IBH USB-S5-Adaptor takes it’s power
t Connection also to passive nodes
supply from the USB port of the PC. It is an active
t rail mount cable, no power supply from the PLCs program-
t Diagnostic LEDs ming port is required. A Constant Current apdater
t Galvanic separation is not needed for this reason. The
IBH USB-S5-Adaptor can be used with
S5 for Windows®, the IBH OPC Server and
USB-S7-Adaptor MPI®, DP, PPI STEP®5 (Drivers for Windows® 2000, XP and Vista
The USB-S7-Adaptor MPI®, DP, PPI is an USB inter- are included).
face to the MPI® / PPI or DP-Bus converter for pro-
gramming software or HMI. The USB-S7-Adaptor
MPI®, DP, PPI has a 1.2m long MPI ® connecting
cable, which can be directly plugged into the pro-
gramming socket of the CPU or to any other node
in the MPI® network. The LCD Display shows the

15
S5 Interfaces

IBH USB-S5-Adaptor
Interfaces the PC USB Port with the 15 pin AS511 Interface port of the PLC. The 15
pin connector housing is made from solid metal and contains the complete
electronics. The IBH USB-S5-Adaptor takes it's power supply from the USB port of
the PC.
It is an active cable, no power supply from the PLCs programming port is required.
A Constant Current adaptor is not needed for this reason. The IBH USB-S5-
Adaptor can be used with S5 for Windows®, the IBH OPC Server and STEP®5
(Drivers for Windows 2000 and XP are included )

PC-S5-Current Loop Converter


The SMD electronics are located in a solid metal 15 pin SubD connector shell. The
pin assignment fits the following SIMATIC® PLCs: U90, U95, U100, U101, U115,
U135, and U155. The PLC must be active and needs to supply the the loop current
(2 x 20mA). The 9 pin SubD connector is plugged into the serial port (COM1
COM4) of the PC.
S5-Online Connections (PLCÅÆPC)

Current Loop Converter Type 1: Pin assignment for Simatic® U90, U95, U100,
The SMD electronics are located in the 15 pin U101, U115, U135, and U155. 15pin Sub.D female connector
Sub.-D connector shell. The pin assignment is with the pin assignment A...9, B...2, C...6, D...7, E...1, F...8).
compatible with the S5 PLC’s (U90, U95, U100, Type 2: Pin assignment for the CNC 800 series. 25pin Sub.-
D male connector with the pin assignment A...13, B...14,
U101, U115, U135, U155). The PLC must be ac- C...10, D...19, E...1, F...1.
tive and must supply the loop current (2 x 20mA). Type 3: Pin assignment for the PLC U150. 25pin Sub.D
The 9 pin Sub.-D connector is plugged into the female connector with the pin assignment A...21, B...20,
C...19, D...18, E/F... shell.
Type 4: The pin assignment is compatible with the 20mA
(TTY) serial connector of the programming devices (connector
PG S5): PG 670, PG 675, PG 685, PG 635 and PG 750. 25-
pin Sub.D female connector with the pin assignment A...22,
B...10, C...8, D...21, E/F...25.
serial port (COM1 - COM4) of the PC. Type X: Pin assignment on customers request.

Extension Cable PC USB Current Loop Converter


The S5 for Windows® Current Loop Converter op- Couples the PC USB Port with the 15 pole X4/X5
tically isolates the PLC from the PC. Cable length interface port of the plc 15pin plug housings are
of several hundred meters (thousand feet) are made of solid
possible (on the current loop side). The extension metal Complete
cable provides an extension between the PLC and electronics in
the Current Loop Converter. The cable provides all the plug hous-
the necessary lines and jumpers. ing Supply of
the cable com-
Constant Current Adapter plete from the
Devices that do not supply the loop current (2 x PC Is „active“ in
20mA) need the Constant Current Adapter for relation of the
connection. Two constant current (20mA) sources plc Is working
are located in the 15 pin Sub.-D connector shell to with standard
supply the loop current. The adapter is delivered S5-Software
with a AC / DC adapter. The pin assignment (Drivers for
matches the pin assignment of the S5 for Win2000 and
Windows® Current Loop Converter. XP included )
Constant Current Adapter

Type 1 (Ref 2042)


Pin assignment for Simatic® U90, U95, U100, U101, U115, U135, and U155. 15pin Sub.D female
connector with the pin assignment A...9, B...2, C...6, D...7, E...1, F...8).

Type 2 (Ref 2044)


Pin assignment for the CNC 800 series. 25pin Sub.D male connector with the pin assignment A...13,
B...14, C...10, D...19, E...1, F...1.

Type 3 (Ref 2046)


Pin assignment for the PLC U150. 25pin Sub.D female connector with the pin assignment A...21,
B...20, C...19, D...18, E/F... shell.

Type 4 (Ref 2048)


The pin assignment is compatible with the 20mA (TTY) serial connector of the programming devices
(connector PG S5): PG 670, PG 675, PG 685, PG 635 and PG 750. 25pin Sub.D female connector
with the pin assignment A...22, B...10, C...8, D...21, E/F...25.

Type X (Ref 2040)


Pin assignment on customers request.
S5 INTERFACES

USB-S5-Current Loop Converter (Ref 20212)

Interfaces the PC USB Port with the 15 pin AS511 Interface port of the PLC. The 15 pin
connector housing is made from solid metal and contains the complete electronics. The USB-
S5 Current Loop Converter takes it's power supply from the USB port of the PC.
It is an active cable, no power supply from the PLCs programming port is required. A
Constant Current apdater is not needed for this reason. The USB-S5 Current Loop
Converter can be used with S5 for Windows®, the IBH OPC Server and Step®5 (Drivers for
Windows 98(SE), 2000 and XP are included )

PC-S5-Current Loop Converter (Ref 2020)

The SMD electronics are located in a solid metal 15 pin SubD connector shell. The pin
assignment fits the following Simatic® PLC’s: U90, U95, U100, U101, U115, U135, and
U155. The PLC must be active and needs to supply the the loop current (2 x 20mA). The 9
pin SubD connector is plugged into the serial port (COM1 COM4) of the PC.
S7-Online Connection (PLCÅÆPC)

S7-PC-MPI-Adapter SSW7 The SSW7 has a 1.2m long MPI connecting cable,
A Hi-Speed Adapter to transfer data between S7 which can be directly plugged into the CPU socket
for Windows® and the Siemens S7-300® and S7- of the programmable controller or at any other
400® is available. This adapter converts the serial point in the MPInetwork.
port signals into the MPI protocol to provide all the The housing of the SSW7-USB contains a type „B“
on-line functions available with S7 for Windows®. USB socket. The SSW7-USB can be connected to
The required power normally is supplied by the the PC via the USB cable supplied. The SSW7-
USB is powered from thePC. The SSW7-USB can
therefore be used at any point in the MPI bus. A
driver for Windows NT / 98/2000/XP is supplied.

Multiplexer for MPI and PROFIBUS


The MPI/Profibus multiplexer permits connection
of up to 3 devices to one MPI or Profibus network.
The MPI/Profibus multiplexer has a 1.2 m long
connecting cable that can be plugged directly into
the CPU socket of the PLC, but also at any posi-
tion in a MPI or Profibus network. The housing of
the MPI/Profibus multiplexers are located in three

S7-300® or S7-400® PLC. If the MPI Bus does not


supply enough power, an external power supply
(15 - 30VDC) may be connected to the SSW7
Adapter. The SSW7 Adapter provides a connector
(9 pin Sub-D) to attach the adapter via a standard
Null-Modem cable (delivered with the SSW7) with
the PC Adapter.

PC USB S7 Adapter
A Hi-Speed Adapter to transfer data between S7
9-way Sub D sockets. Two sockets (“PG” and
“OP”) are located on the top of the MPI/Profibus
multiplexer for connecting devices. The 3rd socket
(“BUS”) on the front can be used to extend the
MPI/Profibus network, or also to connect a third
device. The “PG” socket is the only socket that has
the full MPI pin assignment. That makes it possible
to use “direct operation” on this socket via an MPI
adapter (“SSW 7” or “PC adapter”) with program-
ming software. This pin assignment is not relevant
for operation of Profibus devices. The “BUS
ON/OFF” switch switches on terminating resistors
in the MPI/Profibus multiplexer. It also switches off
the “BUS” socket. This permits operation of the
MPI/Profibus multiplexer at the end of the network
or segment-by-segment start-up of a network. The
MPI/Profibus multiplexer is powered via the con-
for Windows® or Step7® and the Siemens S7- nection line of the CPU. If the terminal does not
300® and S7-400® is available. The SSW7-USB provide 24 V, it is possible to draw the 24 V from
permits conversion from a USB interface to the an external source. The 24 V connector for this
MPI bus for programming software or visualization. purpose (green connector) is polarized.
S7 INTERFACES

USB-S7 Adaptor MPI, DP, PPI (Ref 20218)

The USB-S7 Adaptor MPI, DP, PPI is an USB interface to the MPI/PPI or DP-Bus converter for
programming software or HMI. The USB-S7 AdaptorMPI, DP, PPIi has a 1.2m long MPI
connecting cable, which can be directly plugged into the programming socket of the CPU or at any
other node in the MPI network. The LCD Display shows the transmissonrate and MPI/ DP address.
The housing of the USB-S7 Adaptor MPI, DP, PPI contains a type „B“ USB socket. The Adaptor
can be connected to the PC via the USB cable supplied. The USB-S7 Adaptor MPI is powered
from the PC. The USB-S7 Adaptor ) MPI, DP, PPI can be used at any node in the MPI bus. A
driver for Windows 98/2000/XP is supplied.

USB-S7 Adaptor (Siemens) MPI, DP, PPI (Ref 20216)

The USB-S7 Adaptor (Siemens) MPI, DP, PPI is an USB interface to the MPI/PPI or DP-Bus
converter for programming software or HMI. The USB-S7 Adaptor (Siemens) MPI, DP, PPIi has a
1.2m long MPI connecting cable, which can be directly plugged into the programming socket of the
CPU or at any other node in the MPI network.
The housing of the USB-S7 Adaptor (Siemens) MPI, DP, PPI contains a type „B“ USB socket. The
Adaptor can be connected to the PC via the USB cable supplied. The required power supply is
normally taken from the S7-300® or S7-400® PLCs programming port. The USB-S7 Adaptor
(Siemens) MPI, DP, PPI can be used at any node in the MPI bus. A driver for Windows
98/2000/XP is supplied.

PC-S7 Adaptor (Siemens) serial MPI, DP (Ref 2023)

This adaptor converts the serial port signals into the MPI protocol to provide all online functions
available with S7 for Windows® or Step®7. The required power supply is normally taken from the
S7-300® or S7-400® PLCs programming port. The PC-S7 Adaptor (Siemens) serial MPI, DP has a
9 pin Sub-D connector to connect it to the PC via a standard Zero-Modem cable.
S7 INTERFACES

USB-S7 Adaptor MPI (Ref 20214)

The USB-S7 Adaptor MPI is a USB interface to the MPI bus converter for programming software
or HMI. The USB-S7 Adaptor MPI has a 1.2m long MPI connecting cable, which can be directly
plugged into the programming socket of the CPU or at any other node in the MPI network.
The housing of the USB-S7 Adaptor MPI contains a type „B“ USB socket. The USB-S7 Adaptor
MPI can be connected to the PC via the USB cable supplied. USB-S7 Adaptor MPI is powered
from the PC. The USB-S7 Adaptor MPI can be used at any node in the MPI bus. A driver for
Windows 98/2000/XP is supplied.

PC-Adaptor serial MPI (2024)

This adaptor converts the serial port signals into the MPI protocol to provide all online functions
available with S7 for Windows® or Step®7. The required power supply is normally taken from the
S7-300® or S7-400® PLCs programming port. If the MPI Bus does not supply enough power, an
external power supply (15 - 30VDC) may be connected to the PC-Adaptor serial MPI. The PC-S7
Adaptor serial MPI, DP has a 9 pin Sub-D connector to connect it to the PC via a standard Zero-
Modem cable (delivered with the SSW7).
Accessories

AC/DC Adaptor 24 V for IBH Link S7 (Ref 20279)

If no 24V is supplied,, the AC/DC Adaptor delivers the 24 V.

RJ-45 Crossoveradaptor (Ref 2051)

For direct connetcion of the IBH Link S7 to the networccard of the PC.
For connetcion of the IBH Link S7 Crossover to a switch or hub.

RJ45-female to female connector (Ref 2053)

For extending the RJ45 line of the IBH Link S5, the IBH Link S7,
the IBH Link S7 Crossover or the IBH Link S7 Plus