Power (kVA) 3 Phase,50 Hz, PF 0.8


STANDBY RATING (ESP) PRIME RATING (PRP)
Standby Amper
VOLTAGE
kW kVA kW kVA

400/231 44,00 55,00 40,00 50,00 79,39

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility
source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 %
overload capability is available for a period of 1 hour within 12-hour perod of operation.

General Characteristics
Model Name APD 55 A
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model AKSA A4CRX47
Alternator Made and Model AK 340
Control Panel Model DSE 6120
Canopy ACP 5

ENGINE SPECIFICATIONS
Engine AKSA
Engine Model A4CRX47
Number of Cylinder (L) 4 cylinders - in line
Bore (mm.) 108
Stroke (mm.) 135
Displacement (lt.) 4,95
Aspiration Naturally Aspirated
Compression Ratio 17:1
RPM (d/dk) 1500

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (29.04.2020)
Oil Capacity (Total With Filter) (lt) 14
Standby Power (kW/HP) 55/74.78
Prime Power 50/67.98
Block Heater QTY 1
Block Heater Power (Watt) 500
Fuel Type Diesel
Injection Type and System Direct
Type of Fuel Pump 4BB pump
Governor System Mechanic
Operating Voltage (Vdc) 12 Vdc
Battery and Capacity (Qty/Ah) 1x54
Cooling Method Water Cooled
Cooling Fan Air Flow (m3/min) 180
Coolant Capacity (engine only / with radiator) (lt) 6/20
Air Filter Dry Type
Fuel Cons. Prime With %100 Load (lt/hr) 12.7

ALTERNATOR CHARACTERISTICS
Manufacturer Aksa
Alternator Made and Model AK 340
Frequency (Hz) 50
Power (kVA) 50
VOLTAGE (V) 400
Phase 3
A.V.R. SX460
Voltage Regulation (+/-)1.5%%
Insulation System H
Protection IP22
Rated Power Factor 0.8
WEIGHT COMP. GENERATOR (Kg) 285
COOLING AIR (m³/min) 12,96

Gen.Set Canopy Dimensions (mm)


LENGTH 2282
WIDTH 1008
HEIGHT 1532
DRY WEIGHT (kg.) 1170
TANK CAPACITY (lt.) 180

INTRODUCTION

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (29.04.2020)
Sound–attenuated and Weather-protective Enclosures Sound-attenuated and weather protective enclosures for generating
sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and
development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access
for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed
to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.

Control Panel
Control Module DSE
Control Module Model DSE 6120
Communication Ports CANBUS

1. Menu navigation buttons


2. Close mains button
3. Main Status and instrumentation display
4. Alarm LED's
5. Close generator button
6. Status LED's
7. Operation selecting buttons

Devices
-DSE, model 6120 Auto Mains Failure control module.
-Battery charger input 198-264 volt, output 27,6 V 5 A (24 V) or 13,8 Volt 5A (12V)
-Emergency stop push button and fuses for control circuits.
CONSTRUCTION and FINISH
-Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant
surface. Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable and hinged panel
door provides easy access to components.
INSTALLATION
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at
the Gen.Set. from Alternator)
GENERATING SET CONTROL UNIT
The DSE 6120 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant
temperature running hours and battery volts.
Module monitors the mains supply and switch over to the generator when the mains power fails.
The DSE6120 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving
true first up fault condition of Gen. Set failure.The LCD display indicates the fault.
STANDARD SPECIFICATIONS
-Microprocessor controlled.
-LCD display makes information easy to read.
-Automatically transfers between mains (utilty) and generator power.
-Manual programming on front panel.
-User-friendly set-up and button layout.

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (29.04.2020)
-Remote start.
-Event logging (50) showing date and time.
-Controls: Stop/Reset, Manual, Auto, Test, Start, buttons. An additional push button next to the LCD display is used to
scroll through the modules' metering displays.
Instruments
ENGINE
-Engine speed.
-Oil pressure.
-Coolant temperature.
-Run time.
-Battery volts.
-Configurable timing.
GENERATOR
-Voltage (L-L, L-N).
-Current (L1-L2-L3).
-Frequency.
-Gen. Set ready.
-Gen. Set enabled.
MAINS
-Mains ready.
-Mains enabled.
WARNING
-Charge failure.
-Battery Low/High voltage.
-Fail to stop.
-Low /High generator voltage.
-Under /Over generator frequency.
-Over /Under speed.
-Low oil pressure.
-High coolant temperature.
SHUT DOWNS
-Fail to start.
-Emergency stop.
-Low oil pressure.
-High coolant temperature.
-Over /Under speed.
-Under/over generator frequency.
-Under/over generator voltage.

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (29.04.2020)
-Oil pressure sensor open.
-Coolant temperature sensor open.
ELECTRICAL TRIP
-Generator over current.
Options
-Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
-Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
Standards
-Elecrical Safety / EMC compatibility
-BS EN 60950 Electrical business equipment.
-BS EN 61000-6-2 EMC immunity standard.
-BS EN 61000-6-4 EMC emission standard
STATIC BATTERY CHARGER
- Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
- Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and
27,6 V for 24 V . Input 198 - 264 volt AC.
- The charger is fitted with a protection diode across the output.
- Connect charge fail relay coil between positive output and CF output.
- They are equipped with RFI filter to reduce electrical noise radiated from the device.
- Galvanically isolated input and output typically 4kV for high reliability.

STANDARD SPECIFICATIONS
- Heavy duty, water cooled diesel engine
- Radiator with mechanical fan
- Protective grille for rotating and hot parts
- Electric starter and charge alternator
- Starting battery (with lead acid) including rack and cables
- Engine coolant heater
- Steel base frame and anti-vibration isolators
- Spare external fuel tank (open set)
- Flexible fuel connection hoses
- Two bearing, class H alternator
- Industrial exhaust silencer and steel bellows supplied separately
- Static battery charger
- Manual for application and installation

OPTIONAL EQUIPMENTS
ENGINE

Remote Radiator Cooling

Fuel-Water Seperator Filter


ALTERNATOR

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (29.04.2020)
Anti-Condensation Heater

Main line circuit breaker

CONTROL SYSTEM

Charge Ammeter

TRANSFER SWITCH

Three Pole Contactor

Four Pole Contactor

Three or four pole motor operated circuit breaker

OTHER ACCESSORIES

Main Fuel Tank

Automatic or manual fuel filling system

Manual oil drain pump

Residential silencer
Enclosure: weater protective or sound attenuated

Trailer

Tool kit for maintenance

AKSA CERTIFICATES
- TS ISO 8528
- TS ISO 9001-2008
- CE
- SZUTEST
- 2000/14/EC

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (29.04.2020)